Search NASA⌕ Search

SEARCH · Search NASA

Results for “SLOT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

NDE Technology Engineering Program for Hanford DST Non-Visual Volumetric Inspection Technology: Phase II RAVIS Radiation Tolerance Test Report

This test report provides the results of radiation tolerance robustness testing that was performed on samples of robotic components and an ultrasonic guided wave air-slot sensor that represent components/sub-systems of the Robotic Air-slot Volumetric Inspection System (RAVIS) that has been engineered for volumetric inspection of Hanford tank bottom plates via under-tank refractory pad air-slots. The specific components tested for 1) functionality during active irradiation and 2) tolerance to cumulative radiation dose (until failure or upon reaching a cumulative dose test limit) were: • four samples each of a printed circuit board (PCB) and direct current (DC) motor, which are robotic components, and • 26 ultrasonic piezoelectric elements (samples) inside an air-slot sensor. The robotic components are part of the RAVIS air-slot inspection crawler drive control system that is responsible for remote communication with and actuation of the air-slot inspection crawler. The failure of either of these components during under-tank deployment would require manual retrieval via the crawler’s tether, which risks damage to the robot/refractory/tank. Preemptive replacement of the components at appropriately conservative dose/time intervals informed by failure dose would reduce the likelihood of under-tank failure. The components were included in radiation tolerance testing to quantify their failure doses to inform replacement intervals. The air-slot sensor is responsible for collecting ultrasonic inspection data (scan images) for the tank bottom plates during under-tank deployment. Compromised signal quality due to elevated noise levels caused by gamma radiation would compromise inspection performance. The air-slot sensor was included in radiation tolerance testing to quantify the impact of active irradiation on sensor signal quality. The irradiation and in-situ functional tests of the PCBs, DC motors and air-slot sensor took place in June and July 2020 at the Pacific Northwest National Laboratory. Testing was performed at a gamma dose rate near 300 rad/hr., which, in the absence of under-tank dose rate data, has been conservatively estimated to be the upper-bound dose rate beneath the primary tanks at Hanford. Irradiation took place at elevated temperatures of 150-200°F to determine failure doses that reflect the compounding effects of gamma radiation and heat. The test results revealed: • The DC motors can tolerate being actively irradiated at the high dose rate at 200°F and can tolerate a cumulative dose of 300,000 rad, that which would be incurred after 5 years of service at the 300 rad/hr dose rate. The component therefore meets minimum and preferred radiation tolerance and lifecycle requirements for robotic components. • The air-slot sensor can tolerate being actively irradiated at the high dose rate at 150°F and can tolerate a cumulative dose of 60,000 rad, that which would be incurred after 1 year of service at the 300 rad/hr dose rate. The sensor therefore meets minimum radiation tolerance and lifecycle requirements. • The PCB can tolerate being actively irradiated at the high dose rate, but can only tolerate a cumulative dose of 19,000 rad at 150-200°F. The PCB does not meet minimum radiation tolerance and lifecycle requirements; however, because the component is considered replaceable, it can be replaced before a cumulative dose of 19,000 rad is reached, determined through either monitoring with a dosimeter or scheduled time intervals that are calculated based on conservative estimates of under-tank dose rates.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Double-Shell Tank Primary Bottom Visual Inspection Results - 20025

A pressing need for the Double-Shell Tank Integrity Program at Hanford is of the ability to inspect the bottom of the tanks. Though the DSTs' annulus spaces (the space between the internal and external tank walls) have been inspected visually since 1992 and with Ultrasonic Testing (UT) since 1996, inspections of the tank bottoms have been able to be conducted due to limitations of available technology, omitting about 40 percent of the tank surface below the maximum fill level from routine inspection. Visual inspections of the tank annulus have been conducted up to five times in some DSTs and portions of the annulus space for all of the DSTs has been inspected twice with UT. This region includes the walls of the primary tank and secondary liner along with accessible portions of the secondary liner bottom. Due to this lack of technology, the degradation of the primary tank bottom in Tank AY-102 was undetected until the tank leaked into its annulus space, confirmed in 2012. Since that time, WRPS has been working with the nondestructive examination community and the Pacific Northwest National Laboratory, to evaluate potential technologies to conduct these challenging remote inspections. Recent work has included the development, testing, and deployment of several remote visual inspection technologies to observe the condition of the primary tank bottom of the DSTs by leveraging air distribution slots in the refractory pad on which it rests. Robotic solutions to conduct this inspection were developed with a detailed understanding of the physical configuration and operational logistics. Understanding and subsequent communication of these details to vendors within the robotics and nondestructive examination community was a critical component to the successful production of these new tools. Throughout the FY16-FY18 years, vendors from nondestructive examination community were solicited for ideas to meet the tank bottom inspection challenge. Two tank bottom visual inspection solutions were then pursued to meet that challenge. Both tools were successfully deployed at Tank AP-107, and provided valuable visuals, never before obtained from the under tank environment of a double-shell tank. While there are minor opportunities for improvement identified with each system, general outcomes were overwhelmingly positive. Both systems were successfully able to navigate the refractory air slot pattern from the outer edge to the tank center and record video footage. The micro-crawler provided high quality and very stable footage through the air slot pattern, but took longer to deploy into the slots and traverse through them than the alternative system. The push-pull tethered camera was able to navigate all seven of its target air slots in a matter of a few hours, which included deployment, movement between slot entrances, and complete removal of the system from the annulus environment. Through these air slots, new information was gained about the tank bottom and refractory pad condition of tank AP-107, AP-106, AP-108, and AN-102. While some debris was noted in the air slots, including sand, chipped refractory, and construction materials, the refractory was found to be structurally stable and adequately supporting the primary tank bottom through the full diameter of the tank. Primary tank bottom steel exterior was found to be in good condition, free of ongoing or aggressive corrosion conditions. Looking toward the future, robotic access to and visual inspection of refractory air slots and the primary tank bottom steel has now proven viable. Incorporating periodic air slot inspections as a regular practice within the Double-Shell Tank Integrity Program is the next step, allowing trending of any changes in condition. As ultrasonic testing infrastructure was leveraged to complete the initial system deployments described in this report, it makes sense to adopt that same strategy for ongoing periodic examinations and deploy these primary tank bottom inspection tools alongside ultrasonic testing operations. Development of visual inspection tools to evaluate the primary tank bottom region of the double-shell tanks was planned as the first stage of inspection. Continued development of volumetric sensors and incorporation of these inspection tools into Hanford's ongoing Double-Shell Tank Integrity Program are the next steps, seeking to continuously expand understanding of asset integrity and remaining useful life. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Experiment-modeling studies comparing energy dissipation in the DIII-D SAS and SAS-VW divertors

Recent DIII-D experiments on Small Angle Slot (SAS) divertors have confirmed that a combination of divertor closure and target shaping can enhance cooling across the divertor target and increase energy dissipation, but with significant dependence on B T (toroidal magnetic field) direction. In these novel divertors, the roles of closure, target shaping, drifts, and scale lengths are all interconnected in optimizing dissipation, with the separatrix electron density n eSEP being the key parameter associated with the level of dissipation/detachment. After modifying the original flat-targeted graphite SAS to include a V shape with a tungsten coating on the outer side of the divertor (SAS-VW), matched series of discharges were run to compare to detailed SOLPS-ITER modeling. Experimentally, when run as designed with the outer strike point at the slot vertex, SAS-VW requires nearly identical n eSEP for detachment as the original SAS, with little difference in dissipation for the new geometry. This is in contrast to (1) earlier modeling predictions that a small change of the SAS geometry to a V shape should enhance dissipation at the same n eSEP for magnetic configurations having better H-mode access (ion B × ∇B drift directed into the divertor), and (2) despite the achievement of significantly higher (2-7x) neutral pressures and compression in the SAS-VW slot. Comparisons of experimental density scans to the most recent SOLPS-ITER modeling with ExB drifts show reasonable agreement for dissipation/detachment onset when using separatrix density as the independent parameter. In order to help understand the discrepancy in modeled vs actual performance for the new configuration, additional measurements varying gas injection location and impurity injection were undertaken. In-slot D 2 gas fueling is more effective (5–22 %) in promoting detachment, in accord with modeling. In-slot impurity injection (N 2 or Ne) can yield 30 % lower core Z eff and 15 % less confinement degradation after detachment compared to main chamber puffing, as well as relatively lower tungsten leakage from the divertor. Modeling can also reproduce the improved detachment seen as the strike point moves inboard of the slot vertex. While we can explain the effects of the most important parameters causing energy dissipation in these slot divertors, it remains that many aspects of their behavior cannot be accurately modeled using state-of-art codes such as SOLPS-ITER. This is of concern for future model-driven designs utilizing similar V-shaped geometries.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Boards having solderless interconnects

This disclosure provides systems, methods, and apparatus related to printed circuit boards. In one aspect, a device includes a first board and a second board. The first board includes at least two pins defined at an end of the first board. The first pin and the second pin are positioned along a first line and parallel to the first line. The second board includes at least two slots defined at an end of the second board. The first slot and the second slot are positioned along a second line and are angled from the second line by about ±10° to 15°. Each of the pins in the first board is engaged with each of the slots in the second board and forms an electrical connection between the first pin and the first slot and the second pin and the second slot.

Wielandt, Stijn↗

Stabilizers for a vehicle cooling module

A stabilizing arrangement of a cooling system module of a vehicle includes stabilizer pins attached to the vehicle cooling system module. Stabilizer slots are incorporated into a component of the chassis of the vehicle, such as a frame extender. The stabilizer slots may be formed as an upwards opening U-shape. Bushings are attached to the stabilizer pins. The stabilizer pins and bushings extend laterally into and engage with the stabilizer slots. Upon installation, the stabilizer pins and bushings are aligned with the stabilizer slots as the cooling system module is lowered onto the ISO mounts. The stabilizer pins and bushings slide vertically downwards into the stabilizer slots as the cooling system module is lowered into place. The simpler stabilizer pins, bushings, and stabilizer slots thereby take the place of expensive, time consuming, complex, labor intensive, and space consuming stay rod arrangements.

Wu, Shouhao↗

Tamper-resistant fastener

A tamper-resistant threaded fastener including a circular head having a slot formed in the head transverse to the longitudinal axis, the slot having an enlarged region intermediate an apex and a base of the slot. A cap member includes a head having a drive feature formed therein, the head extending to a first shank portion, extending to an enlarged second shank portion, extending to a foot. The cap member is insertable in the slot only from a direction transverse to the longitudinal axis. During rotational installation of the fastener and cap member in a threaded counterbored opening for securing a barrier for protecting an asset, the foot shears inside the slot at a predetermined rotational drive force, the cap member being rotatable in the opening and protectively covering the fastener head.

Neidigk, Stephen↗

Electric motor cooling with oscillating heat pipes

A stator and a motor including a stator. The stator includes a stator hub, a plurality of stator teeth extending from the stator hub that define a stator slot having a stator slot base, at least one winding disposed in the stator slot, and one or more oscillating heat pipes disposed at least partially in the at least one winding. The at least one winding is held apart from the stator slot base so that a cooling channel is defined between an inner winding portion of the at least one winding and a portion of the one or more oscillating heat pipes is disposed in the channel so cooling fluid can be passed between the stator slot base and the inner winding portion to cool the inner winding portion via at least operation of the one or more oscillating heat pipes.

Alahyari, Abbas A.↗

Inspection Tools for Hanford Tanks and Waste Transport Systems - 20444

Recent integrity issues in the double-shell tanks (DST) at Hanford have motivated the need for developing innovative tools that can provide information regarding the health of the tanks. These issues include the primary linear failure of AY-102 and recent concerns of thinning in the DST secondary liners. Other concerns include erosion or corrosion on transfer lines and processing pipes. In recent years, Florida International University (FIU) has supported DOE-EM by developing tools that can assist in understanding the health of tanks and waste transport system at Hanford. More specifically, FIU has developed a miniature rover that can be deployed through small risers and gain access to refractory slots in the Hanford DSTs. It traverses through the slots on the primary liner upside down via magnets to avoid debris in the slots. Recent modifications include a spring loaded magnetic arm that allows the unit to traverse over large weld seams but does not reduce the overall functionality of the system. The system has also incorporated a control capsule that will sit within the annulus of the tank and improves on issues related to signal and voltage loss over long tether lines. Lastly, the unit is also being augmented with a second module that will include a means to prep the tank surface and obtain a thickness measurement using a dual element ultrasonic sensor. FIU has also developed a 6-inch peristaltic pipe crawler that operates similar to the previous pipe crawlers developed at FIU. This crawler is a marsupial type crawler that will navigate through the 6-inch drain lines, and deploy a small rover at the entrance of the drain slots. This rover will also traverse upside down on the secondary liner and provide information regarding the health of the liner. An initial prototype for the crawler unit has been developed, assembled and tested. The system is pneumatic and consists of three modules - two grippers and one extender. The validation tests are conducted in a mockup of the drain lines and demonstrate the system's ability to navigate through long pipe lengths and elbows. In this paper, a general overview of each of the aforementioned systems is presented along with results from testing and demonstrations that shows the applicability of each system. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Eco–Friendly Solvent Engineered CsPbI 2.77 Br 0.23 Ink for Large–Area and Scalable High Performance Perovskite Solar Cells

The performance of large-area perovskite solar cells (PSCs) has been assessed for typical compositions, such as methylammonium lead iodide (MAPbI 3 ), using a blade coater, slot-die coater, solution shearing, ink-jet printing, and thermal evaporation. However, the fabrication of large-area all-inorganic perovskite films is not well developed. This study develops, for the first time, an eco-friendly solvent engineered all-inorganic perovskite ink of dimethyl sulfoxide (DMSO) as a main solvent with the addition of acetonitrile (ACN), 2-methoxyethanol (2-ME), or a mixture of ACN and 2-ME to fabricate large-area CsPbI 2.77 Br 0.23 films with slot-die coater at low temperatures (40–50 °C). The perovskite phase, morphology, defect density, and optoelectrical properties of prepared with different solvent ratios are thoroughly examined and they are correlated with their respective colloidal size distribution and solar cell performance. Here, the optimized slot-die-coated CsPbI 2.77 Br 0.23 perovskite film, which is prepared from the eco-friendly binary solvents dimethyl sulfoxide:acetonitrile (0.8:0.2 v/v), demonstrates an impressive power conversion efficiency (PCE) of 19.05%. Moreover, the device maintains ≈91% of its original PCE after 1 month at 20% relative humidity in the dark. It is believed that this study will accelerate the reliable manufacturing of perovskite devices.

binary and ternary solvent↗

Reducing impacts of artificial ponding in modeling salt marshes using a conductivity-formulated subgrid model

The landforms of salt marsh systems are rather complex, with meandering channel networks cutting through low-lying, extensive marsh platforms. Some small-scale topographic details are critical to flooding and draining processes but cannot be reflected in the Digital Elevation Model (DEM) due to limited measurement resolution and vegetation bias. Numerical models need a grid with high enough resolution to capture the small-scale connectivity to correctly model the small-scale flow processes, making the model computationally unaffordable. Here, in this study, we derived a subgrid model, which couples two flow components, one is the regular subgrid model for simulating the subgrid-resolved flows, and the other is a conductivity-formulated porous flow model for modeling small-scale gut flows unresolved at the subgrid level. The model validation was performed using an idealized case with a narrow slot that was unresolved in the coupled flow model. Model results were compared with a slot-resolved regular subgrid model where only surface flows are solved and suggested that, with a proper model parameterization, the coupled flow model is capable of reproducing flooding and draining processes similar to the slot-resolved subgrid model of surface flow. The model was applied to simulating flooding and draining processes in a meso-tidal salt marsh. The model results demonstrate that the coupled subgrid model can be used to reduce the impacts of artificial ponding that usually occur in numerical simulations of salt marshes with numerous narrow gullies and creeks.

54 ENVIRONMENTAL SCIENCES↗

Investigating the effect of B T direction on W source-to-core pathways during the SAS-VW campaign on DIII-D

Experiments using the V-shaped closed slot tungsten (W) coated SAS-VW divertor in DIII-D studied the effects of the BT direction on core contamination of eroded tungsten from a closed slot divertor configuration. Core W content is inferred using soft-X ray tomography (SXR) and vacuum ultraviolet spectroscopy (SPRED), while W divertor erosion is inferred from visible spectroscopy of W emission (400.9 nm) measured by in-slot filterscopes (filtered photo-multipliers). Post-mortem analysis from the campaign discovered tile misalignment leading to suspected pronounced leading-edge erosion in the unfavorable BT direction (ion B ⃗×∇B ⃗ drift away from divertor) likely not captured by diagnostics. However, empirical findings show up to ~2-3x larger core contamination in the favorable BT direction even considering no additional W erosion from leading edges. A “source-to-core efficiency factor” is derived to estimate the effects of leading-edge erosion and compare W contamination for two pairs of H-mode discharges in opposite BT directions. While having differing absolute parameters, similar core impurity density gradients suggest comparable core impurity transport. These results show that favorable BT may have stronger source-to-core pathways for W impurities sourced from the outer divertor region. Possible explanations could include the effects of E ⃗×B ⃗ drifts on W transport in the scrape-off-layer (SOL) as well as previously determined fast SOL inner target directed flows in favorable BT.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Tungsten erosion during L-mode discharges in the DIII-D SAS-VW divertor

A series of L-mode plasma discharges was performed in the DIII-D tokamak to assess the impact of outer strike point (OSP) position and toroidal magnetic field direction on erosion and core contamination potential of the recently-installed, tungsten-coated Small Angle Slot (SAS-VW) divertor. In one discharge, in-slot emission spectroscopy measured an<48 % increase in the W gross erosion rate when the OSP was moved 3 cm outwards, away from the V-shaped vertex of the slot divertor. However, the effective W yield (erosion rate divided by the incident D flux) was, overall, insensitive to changes in OSP location. Consistently low estimates of the effective W yield based on measurements taken a few cm outwards from the vertex suggest potentially significant C surface contamination. No W emission signal was detected when orienting the toroidal magnetic field such that the ion B×∇B drift direction is pointed away from the X-point. However, measurements of W content in the plasma core for both toroidal magnetic field directions suggest the presence of additional, unmeasured sources of erosion. The difference in the measured core W density with OSP position is much greater than the difference in the measured erosion rates, which may suggest that the leakage of eroded impurities out of the divertor is governed primarily through the parallel ion temperature gradient and friction forces.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Failure investigation and mitigation after experimental research reactor fuel plate deformation in an irradiation device

Experimental research reactor fuel testing is conducted in the Belgian Reactor 2 (BR2) of the Belgian Nuclear Research Centre (SCK CEN) in dedicated irradiation vehicles or rigs. One such vehicle allows flat full-size fuel plates to be irradiated by inserting them into slotted baskets that captures a narrow portion of the longitudinal edges of the plates. The motion of the fuel plates within the baskets is possible within the narrow slots and thus, the plate is considered to be unattached. The design intentionally omits fixing mechanisms of the fuel plates to the baskets to facilitate the inspection and repositioning of the plates between the irradiation cycles and the accommodation of thermal expansion of the plates in the lateral direction. However, loosely inserted fuel plates have weak structural boundary conditions allowing for larger out-of-plane deflections caused by hydrodynamic loads exerted by the flowing coolant, as compared to those of fixed plates. Unexpected large deformations of plates occurred in several irradiation cycles that further resulted in a loss of cladding integrity. These deformations could not be attributed to a single source. This triggered a series of thermal hydraulic, structural, and fluid-structure interaction analyses aiming at understanding the observed phenomenon. The analyses revealed that, for a certain combination of unfavorable manufacturing and assembly tolerances, fuel plate edges could escape out of the slots in the irradiation basket due to the hydrodynamic load. Subsequently, the plate could become wedged inside the basket coolant channel opening. This resulted in reduced coolant flow and accelerated temperature increase and thermal expansion of the plate while under irradiation. This unfavorable feedback loop could then lead to excessive plate surface temperatures, deformed plates and cladding failure, as was observed in the experiments. These analyses not only provided a probable cause of the fuel plate failures, but also resulted in a new and improved design of the irradiation basket to avoid these issues in the future. In conclusion, a series of recent successful irradiations confirm that the sources of failures were identified correctly, and the implemented mitigations were adequate.

BR2↗

TRUST Testing Procedure Documentation

The TRUST testbed was designed and fabricated to conduct vibration testing and validate the behavior of hyper-elastic foams in a pre-loaded condition. The main goals of this testbed design were to ensure symmetry, proper instrumentation alignment and mounting, simplified geometry to make the data analysis validation process more straightforward, and to apply and monitor the applied pre-load. Based off of the test parameters, a shaker system was purchased. The baseplate was designed to mount directly to the bolt holes provided on the top of the shaker table. It was determined that the specimens will be cylindrical and vary in thickness from 2-10mm. The baseplate riser, center-mass, and testbed cap were designed to be cylindrical to make alignment about the center axis more straightforward. It was determined to fabricate the parts previously mentioned using Aluminum 6061-T6 due to its stiffness in order to reduce the likelihood of the stiff material impacting the data being collected for the foam specimens. The design concept used to apply the pre-load to the testbed was a through bolt/nut configuration. A through hole was included in each piece of the testbed, specimens, and instrumentation large enough to allow for 1/8” clearance between the through bolt and each of these pieces. This was imperative to avoid causing friction and complicating the validation model. A load cell was then purchased and used to measure the pre-load being applied to the testbed. It was also required to collect data for 3 axes at 3 different locations 120° apart on the center-mass. This configuration was required to be placed on the cylindrical face and toward the top and bottom of the center-mass. Slots were milled out in the middle of each sensor block with tight tolerances for mounting each of the accelerometers at 120° apart. This same approach was taken to mount 2 accelerometers on the baseplate at 180° apart. Holes were milled out of the corners of each accelerometer mounting slot to relieve the corner and allow for a flat edge at the back of each slot. Sensor blocks were mounted into the center-mass using 6-32 bolts at the required locations. This initial testbed design was fabricated at the TA53 machine shop.

42 ENGINEERING↗

Modal Field Reconstruction in Resonant Cavities in the Fundamental and Undermoded Frequency Regimes

Theory, simulations, and experiments are presented that demonstrate reconstruction of electromagnetic fields in a cavity from sparse probe measurements. Such techniques are often referred to as virtual sensing, allowing fields at unobserved locations to be predicted. These methods are appropriate for the fundamental and undermoded regimes, providing the ability to estimate fields (and shielding effectiveness) throughout an arbitrarily shaped cavity from a few judiciously spaced probes. A modal simulation method is implemented that allows the response of arbitrarily shaped cavities to be rapidly computed with respect to varying probe locations and slot parameters, enabling statistical analysis of probe placement on reconstruction performance. A cylindrical vessel with numerous probe holes is developed for experiments, referred to as Perforated Vessel 2 (PV2). Experiments are performed on the vessel with and without a steel box inside, where transmit power is delivered into the vessel either through probes (probe injection) or through slots using an external antenna (slot excitation). Simulations and experiments illustrate that when the number of probes is minimal (equal to the number of mode coefficients to be estimated at each frequency), probe placement is critical to avoid missed peaks and to have acceptable reconstruction error. Probe placement becomes less important as the number of probes is increased, but care is still required to avoid probe locations giving poor performance.

42 ENGINEERING↗

System and method for selective transmission and reception for stationary wireless networks

A system and methods for selective transmission and reception for stationary wireless networks. The system and method include an end user equipment, a primary base station, a core network, and a selective server. The end user equipment transmits a request for transmission to the primary base station receiver. The primary base station authenticates the end user equipment using a cellular network authentication process. The primary base station then searches for a time slot data for the end user equipment from the selective server and determines whether the time slot is open for transmission, steers a beam towards the end user equipment when time slot is open for transmission. The primary base station then enables transmission from the end user equipment, wherein the enabling is performed by the primary base station. The core network receives the transmission from the end user equipment.

Bhuyan, Arupjyoti↗

Wick assisted embedded evaporative cooling of motors

A cooling system for an electric motor that includes a stator having a plurality of slot windings and a rotor, coaxial with the stator, having a plurality of magnets, includes a coolant inlet to the motor and a coolant outlet from the motor. A coolant pathway is in fluid communication with the inlet and the outlet. Heat is transferable from the slot windings to the coolant pathway. A coolant flows through the coolant pathway and is in a liquid phase as it enters the coolant inlet, changing into a gaseous phase as heat is transferred to the coolant from the slot windings. A cooling loop is in fluid communication with the coolant inlet and the coolant outlet. The cooling loop cools the coolant so that substantially all of the coolant is in the liquid phase when it enters the coolant inlet.

Joshi, Yogendra K.↗

Scalable aqueous-phase fabrication of reduced graphene oxide nanofiltration membranes by an integrated roll-to-roll (R2R) process

Economic fractionation of multicomponent biomass-derived streams is a key challenge in biobased fuels and chemicals production. Kraft black liquor (BL) is generated at ~1 billion tons/yr globally from biomass pulping and contains ~15wt% total solids including lignin, hemicellulose fragments, and inorganics. Membrane-based BL concentration is attractive but challenged by low solute rejections and poor stability in BL, which combines alkaline pH (~13), high dissolved solids content (15+ wt%) and high temperature (70–85°C). Here we discuss the scaled fabrication and characterization of reduced graphene oxide (rGO) nanofiltration membranes by slot die coating on a roll-to-roll (R2R) with integrated vacuum filtration. Here, we obtain high-quality 90×30 cm rGO membranes (referred to as “R2R-rGO membranes” in this work) with ~100 nm average thickness supported on porous poly(ethersulfone) (PES) sheets, and an effective area of 2700cm 2 . We present characterizations of their microstructure and uniformity as mapped over large areas by scanning electron microscopy (SEM), ellipsometry, adhesion test and X-ray photoelectron spectroscopy (XPS). The constructed ellipsometry model for the rGO membrane/PES substrate composite was successfully applied to 48 different locations of the R2R-rGO membranes. The R2R-rGO membranes showed >98% lignin rejection with a steady state flux of ~12 LMH at 50bar in a 15.7wt% total solids (TS) kraft BL stream at 72°C and 2–3 gal/min crossflow rates. Slot die coating on a R2R platform with integrated vacuum filtration can enable rapid fabrication of high-quality GO membranes at scale without organic solvents or volatile organic compounds.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗