Search NASA⌕ Search

SEARCH · Search NASA

Results for “SODIUM IODIDE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Metal halide arc discharge lamp having short arc length

A metal halide arc discharge lamp includes a sealed light-transmissive outer jacket, a light-transmissive shroud located within the outer jacket and an arc tube assembly located within the shroud. The arc tube assembly includes an arc tube, electrodes mounted within the arc tube and a fill material for supporting an arc discharge. The electrodes have a spacing such that an electric field in a range of about 60 to 95 volts per centimeter is established between the electrodes. The diameter of the arc tube and the spacing of the electrodes are selected to provide an arc having an arc diameter to arc length ratio in a range of about 1.6 to 1.8. The fill material includes mercury, sodium iodide, scandium tri-iodide and a rare gas, and may include lithium iodide. The lamp exhibits a high color rendering index, high lumen output and high color temperature.

Muzeroll, Martin E.↗

Fermi Gamma-ray Space Telescope

The Fermi Gamma-ray Space Telescope, a key mission in multiwavelength and multimessenger studies, has been surveying the γ-ray sky from its low-Earth orbit since 2008. Its two scientific instruments, the Gamma-ray Burst Monitor (GBM) and the Large Area Telescope (LAT), cover 8 orders of magnitude in photon energy. The GBM consists of 12 Sodium Iodide detectors and 2 Bismuth Germinate detectors, covering the 10 keV - 40 MeV energy range, arrayed on two sides of the spacecraft so as to view the entire sky that is not occulted by the Earth. The LAT is a pair production telescope based on silicon strip trackers, a Cesium Iodide calorimeter, and a plastic scintillator anticoincidence system. It covers the energy range from about 20 MeV to more than 500 GeV, with a field of view of about 2.4 steradians. Thanks to their huge fields of view, the instruments can observe the entire sky with a cadence of about an hour for GBM and about three hours for LAT. All γ-ray data from Fermi become public immediately, enabling a broad range of multiwavelength and multimessenger research. Over 3000 γ-ray bursts (GRBs), including GRB 170817A associated with a neutron star merger detected in gravitational waves, and 5000 high-energy sources, including the blazar TXS 0506+056 associated with high-energy neutrinos, have been detected by the Fermi instruments. The Fermi Science Support Center provides a wide array of resources to enable scientific use of the data, including background models, source catalogs, analysis software, documentation, and a Help Desk.

gamma rays↗

Replacing photomultiplier tubes with silicon photomultipliers for nuclear safeguards applications

Photomultiplier tubes (PMTs) have been used for decades as the default light detection technology for scintillator-based radiation monitors. PMTs come with a handful of disadvantages, however, including large volume usage, fragility, high-voltage requirements, and susceptibility to magnetic fields. Arrays of silicon photomultipliers (SiPMs) are a possible alternative to PMTs providing similar performance while offering improvements in the areas listed. We focus on straightforward “drop-in replacement” evaluations by imposing a single channel output of the SiPM signal and a backend electronics data acquisition and analysis routine identical to that used for PMTs. In the realm of nuclear safeguards, the primary performance metric for gamma spectroscopy is detector resolution, and for neutron detection it is pulse shape discrimination (PSD) to separate neutron and gamma signals. In this work we present the results of replacing a PMT with a 2” x 2” SiPM array mounted, in turn, to the same 2” x 2” cylindrical sodium iodide (NaI) crystal. The ultimate comparison for this gamma spectrometry is confirmation of uranium enrichment standards, ranging from depleted uranium to 93% highly enriched uranium (HEU), by analyzing the resulting spectra with both a simple integral scaling in key energy regions of the spectrum, as well as with the NaIGEM software package. In addition to the gamma spectroscopy work, we will present the latest results on comparing the PSD capabilities of a 4” x 4” SiPM array to a 5” PMT. As with the gamma spectroscopy evaluations, the light detectors are mounted in turn to the same liter-scale organic scintillators. This neutron-focused work includes evaluation of prototype SiPM readout boards with a single output signal summed over 256 individual SiPM pixels, and evident tradeoffs between PSD capability and fast response.

Engineering - Instrumentation related to nuclear s↗

AMS / BARC Joint Survey Addendum Technical Report

This report details the data analysis results from data collected during the September-October 2019 joint survey series between the Department of Energy (DOE) National Nuclear Security Administration (NNSA) Aerial Measuring System (AMS) asset, and the Government of India’s Department of Atomic Energy (DAE) Bhabha Atomic Research Centre (BARC). This joint survey series took place at the Nevada National Security Site (NNSS), areas of public land in Southern Nevada, and at the DOE Office of Legacy Management (LM) Large Area Calibration Pads (LACP) at the Grand Junction Regional Airport in Grand Junction, CO. The data detailed in this report were gathered at the LACP. More details regarding the setup of these surveys and personnel involvement can be found in the AMS / BARC Joint Survey Summary Report. The data from the LACP collected by AMS are consistent with past data collection campaigns at the LACP. The AMS Bell 412 (B412) helicopter, equipped with both the standard AMS thallium-doped sodium iodide (NaI(Tl)) 2"x4"x16" 12-detector system and a subset of the BARC Aerial Gamma Spectroscopy System (AGSS) consisting of two independent 3"x3"cylindrical NaI(Tl) detectors, measured each of the five calibration pads for a minimum of 10 minutes. After the helicopter measurements, a pressurized ion chamber (PIC) was used to directly measure radiation exposure rates on each of the pads for a period 5 minutes. The geophysical calibration procedure published by the International Atomic Energy Agency (IAEA) (Erdi-Krausz et al. 2003) was used to determine the spectral stripping sensitivity matrix for naturally occurring radiological material (NORM). The sensitivity matrix is consistent with the AMS long term average. Additionally, the PIC data was used to calibrate the AMS system for exposure rate. The results of the exposure rate analysis are also consistent with AMS long-term averages.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Quantity of 135I Released from the AGR 5/6/7 Experiment

A series of four Advanced Reactor Technologies (ART) experiments have been conducted in the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL). From 2006 through 2020, these experiments supported the development and qualification of the new U.S. tristructural isotropic (TRISO) particle fuel for Very High Temperature Reactors (VHTR). Each Advanced Gas Reactor (AGR) experiment consisted of multiple fueled capsules, each plumbed for independent temperature control using a mix of helium and neon gases. The gas leaving a capsule was routed to individual Fission Product Monitor (FPM) detectors. For intact fuel particles, the TRISO particle coatings provide a substantial barrier to fission product release. However, particles with failed coatings, whether because of a minute percentage of initially defective particles, those which fail during irradiation, or those designed to fail (DTF) particles, can release fission products to the flowing gas stream. Because reactive fission product elements like iodine and cesium quickly deposit on cooler capsule components and piping structures as the effluent gas leaves the reactor core, only the noble fission gas isotopes of Kr and Xe tend to reach FPM detectors. The FPM system utilizes High Purity Germanium (HPGe) detectors coupled with a thallium activated sodium iodide NaI(Tl) scintillator. The HPGe detector provides individual isotopic information, while the NaI(Tl) scintillator is used as a gross count rate meter. During irradiation, the 135mXe concentration reaching the FPM detectors is from both direct fission and by decay of the accumulated 135I. About 2.5 hours after irradiation (ten 15.3 minute 135mXe half lives) the directly produced 135mXe has decayed and only the longer lived 135I remains as a source. Decay systematics dictate that 135mXe will be in secular equilibrium with its 135I parent, such that its production rate very nearly equals the decay rate of the parent, and its concentration in the flowing gas stream will appear to decay with the parent half life. This equilibrium condition enables the determination of the amount of 135I released from the fuel particles by measurement of the 135mXe at the FPM following reactor shutdown. In this paper, the 135I released will be reported.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High fidelity ground deposition measurement with robots after explosive radiological dispersion

A team of scientists from the Remote Sensing Laboratory at Joint Base Andrews, Maryland, has assembled a remote-controlled robot to field a few sodium iodide scintillators of different size and shape 18″ above ground for measurement of ground deposition of gamma-emitting particles after an explosion of a radiological dispersal device. This system uses a high-precision differential GPS device with submeter accuracy for radiation mapping. The system is most useful in characterizing large-area contamination and detecting gamma radioactivity in invisible, submicron particulate debris deposited on the ground at surface level or embedded in subsurface up to 3″ deep. The system was assembled as part of a larger effort to integrate advanced radiological detection devices into autonomous or remote-controlled robotic systems to eliminate or minimize the need for emergency responders to enter areas that pose significant health and safety risks to humans following a major radiological incident or accident. Research into autonomous algorithms is required to develop automated robotic systems for radiological survey and characterization activities in highly contaminated areas. The scope of this project also includes developing communications pathways and supporting infrastructure capabilities for different types of robotic technologies. The expected result is an advanced autonomous robotic system with integrated radiation detection electronics that allows emergency response personnel to view data remotely and in real time for radiological emergency response and consequence management purposes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of Scintillating Crystal for High Energy Radiation Detection and Applications

Cesium Hafnium Chloride (Cs2Hfl6) is a promising metal halide scintillating detector due to its excellent characteristics such as non-hygroscopicity, high light yield without doping. Scintillators plays an important role in nuclear security applications as detectors at border monitoring stations. We grew and characterized CHC crystals to be fabricated for gamma detection. Photoluminescence was performed using the Duetta Fluorescence and Absorbance Spectrometer. The energy response to Cs-137 and Co-60 reference sources was recorded for a representative sodium iodide (NaI) scintillating detector.

Reeder, Angel↗

Spectra-to-exposure conversion using polynomial response models for gamma-ray field characterization

Accurate measurement of exposure rate from gamma-ray spectral data remains a critical challenge during radiological emergency response operations. Conventional methods rely on pre-defined static conversion factors derived from fixed geometries and isotopic compositions, which often fail to capture real-world environmental variability. This study presents a generalized approach as a "next-step" for converting gamma-ray spectral data into exposure rate using polynomial response models. The method introduces a flexible weighting scheme based on the in-situ detector response to distributed sources, enabling a pathway towards improved correspondence between measured spectra and "ground-truth" exposure rates. Experimental data from sodium iodide NaI(Tl) detectors were used to validate the approach as, at least equivalent to the current count-to-exposure method employed in emergency response CONOPS. Results show that the polynomial weighting model is sufficiently equal to the count-to-exposure method and may help improve accuracy given its adaptability to real-world conditions.

61 RADIATION PROTECTION AND DOSIMETRY↗

Low temperature sodium battery comprising an electrochemically active molten inorganic catholyte

A high-performance electrochemically active sodium molten salt catholyte enables a dramatic reduction in molten sodium battery operating temperature from near 300° C. to less than 120° C. As an example, stable electrochemical cycling was demonstrated in a high voltage (3.65 V) sodium battery comprising a sodium iodide-gallium chloride (NaI—GaCl 3 ) molten salt catholyte for over 8 months at 110° C. The combination of high voltage, stable cycling behavior, and practical current densities supported by a molten catholyte enables a new generation of transformative high performance, low temperature molten sodium batteries.

Spoerke, Erik D.↗

Biogeochemistry of the Antrim Shale Natural Gas Reservoir

The Antrim Shale, located in the Michigan Basin, United States (U.S.), is a major U.S. shale play having produced over 2.5 Trillion Cubic Feet (Tcf) of unconventional shale natural gas as of 2010. The shallow nature of this formation sets it apart from other, more characterized unconventional shale gas plays. The depth of gas production of the Antrim ranges from approximately 150 to 600 m and it is typically vertically drilled, contrary to deeper, horizontally drilled shales. A thorough understanding of the biogeochemistry and microbiology of this complex system will be advantageous for improving well performance, produced water management, and potential biocidal treatment as microbial community composition can vary substantially even among closely spaced wells. In this study, we analyzed produced water collected from nine different wells in the Antrim Shale by investigating the geochemical and microbial community composition of the produced water to gain greater insight into the overall biogeochemistry of this unique shale system. The majority of the wells from this study had high total dissolved solids (TDS) primarily composed of chloride and sodium, averaging 86,804 mg/L with a maximum 116,223 mg/L; however, three of the wells sampled along the northern margin of the basin exhibited significantly lower TDS ranging from 4932 to 6496 mg/L. Overall, our microbial community analysis revealed relatively low abundance within our samples and high variability of the microbial community among the sampled wells. The majority of bacterial sequences were identified within Proteobacteria, Firmicutes, and Actinobacteria phyla and metagenomic sequencing revealed the low presence of Methanobacteriaceae within each sample. We also investigated potential microbial community drivers and found that TDS, sodium, chloride, iodide, bromide, ammonium, potassium, and strontium were significantly correlated with the observed microbial community. The varying geochemical conditions between wells demonstrate different subsurface environmental niches, potentially driving the heterogeneous microbial communities we observed from well to well. This analysis suggests an important relationship between both well location and geochemistry and the observed microbial community that can persist in the reservoir. Continued studies of the Antrim Shale will improve our understanding of the complex interdependencies of this ecosystem.

03 NATURAL GAS↗

Extremely Low Energy Nuclear Recoil Calibrations for Dark Matter Direct Detection (Final Technical Report)

This project developed and demonstrated a new calibration approach for low-energy nuclear recoils in solid-state detectors based on neutron capture. Precise calibration in the sub-keV regime is a critical challenge across the HEP portfolio. Existing measurements show deviations and inconsistencies across methods. Neutron capture provides a complementary approach producing discrete recoils via γ cascades.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Large Volume Airborne Contamination Monitoring To Support Nuclear Processes' Deactivation and Decommissioning

Current D and D operations at Hanford have demonstrated a flaw in the current state of the art capability of defining airborne contamination boundaries - Airborne particulate emissions of Pu-239 from CM2H operations on the Hanford Pu Finishing Plant were detected well beyond areas controlled for airborne Pu, putting numerous workers at risk for radiological assimilations - Current air samplers and CAM systems were surveying insufficient volumes of air to accurately predict where respiratory protection was required - Hanford is located in a high radon environment, making air monitoring for alpha emitting actinides challenging in high alpha radon induced backgrounds. - Inexpensive HEPA based home and industrial air purifiers filter significantly higher volumes of air than commercially available continuous-air monitoring (CAM) systems. - Inexpensive models capable of filtered air volumes exceeding 1000 times that of a CAM. - Detector system can be built to detect x-rays generated from actinide decay. - Branching ratios of x-rays are 4 orders of magnitude more intense from Plutonium decay than its gamma emissions. - Detector system can be a low resolution systems, as x-ray region of interest is not terribly congested. - Detection systems evaluated will be designed based on slabs of NaI or pixelated NaI or CsI panels. - Simple graphical user interface software will be developed to operate the detection system. - Concept is to deploy some of these air-purifying systems in nonradiological areas around SRNL to confirm radon can be rejected with confidence. - Generate some filters contaminated with plutonium via electroplated Pu or lab generated simulated particles. - then deploy units in known airborne radiological environments to establish systems ability to accurately measure actinide based hot particles Lab analyses will follow up the system analyses to ensure hot particles were correctly identified. Analysis by Scintillation: - Application of scintillation media to the surface of the filters is being explored. - Evaluating slabs of ZnS(Ag), application of powdered ZnS(Cu) and spray on Perkin Elmer Enhance. - Scintillation events would then be digitized with a digital camera and quantified. - Comparing against sensitivity of a PMT or SiPD readout. - Currently evaluating a Thorlabs 8 Megapixel Monochrome Scientific CCD Camera, hermetically sealed cooled package with a wide angle lens. - Wide angle lens allows complete view of HEPA filter from 7 inches away. - Images taken of glow in the dark paint, as well as plutonium-induced fluorescence. - Plutonium was flamed mounted on a 1 inch diameter stainless steel planchet, covered with a layer of mylar and a section of scintillating ZnS obtained from Eljon. - Currently working on reducing signal-to-noise levels to boost sensitivity. - Dark box to hold contaminated or electroplated source covered filters under fabrication. Analysis by x-ray Spectroscopy: - Branching ratios for x-ray emissions from Plutonium isotopes are orders of magnitude more intense than gamma-ray emissions. - The nuclear databases are incomplete on the branching ratios of some of the isotopes. - Evaluating some custom built SrI2 x-ray spectrometers vs a conventional windowed NaI detector. - SrI2 detectors are carbon-composite-windowed 51 mm x 51 mm. - MCNP calculations to establish self absorbance of filter media on 17 keV x-ray. Radon Rejection: - Activated charcoal pre-filter acts as a Radon trap. - Adding a time lapse feature to camera to aid in radon rejection. SRS Plutonium Fuel Form D and D Operations: Currently deploying air sampler to D and D operation of Pu-238 facility at SRS to generate some field samples to analyze.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Physical property measurements of doped cesium iodide crystals

Mechanical and thermal property values are reported for crystalline cesium iodide doped with sodium and thallium. Young's modulus, bulk modulus, shear modulus, and Poisson's ratio were obtained from ultrasonic measurements. Young's modulus and the samples' elastic and plastic behavior were also measured under tension and compression. Thermal expansion and thermal conductivity were the temperature dependent measurements that were made.

Synder, R. S.↗