Search NASA⌕ Search

SEARCH · Search NASA

Results for “SPACE ORIENTATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Acousto-optical properties of metamaterials

The possibility of the effective use of metamaterials in acousto-optics is demonstrated. It is shown that photoelastic constants that determine a change in the dielectric constant of a heterogeneous medium under the action of a sound wave can significantly exceed the corresponding constants for conventional crystals. We have analysed the mechanisms of the dielectric constant variation in a heterogeneous medium consisting of nanoparticles in the form of ellipsoids and have found explicitly the values of the photoelastic constants. It is shown that the mechanism of the dielectric constant variation in a longitudinal sound wave is reduced to a change in the local concentration of nanoparticles in the bulk and in a transverse acoustic wave – to a local rotation of space-oriented nanoellipsoids. It is also shown that the use of metamedia with a nonuniform distribution of nanoparticles provides a unique opportunity for designing qualitatively new instruments and devices that cannot be produced on the basis of conventional crystals. It is noted that metamaterials open ample opportunities for creating devices of the IR region of the spectrum due to the absence of restrictions on the size of such media. (metamaterials)

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A generalized a priori dose uncertainty model of IMRT delivery

Multileaf collimator-based intensity modulated radiation therapy (IMRT) is complex because each intensity modulated field consists of hundreds of subfields, each of which is associated with an intricate interplay of uncertainties. In this study, the authors have revised the previously introduced uncertainty model to provide an a priori accurate prediction of dose uncertainty during treatment planning in IMRT. In the previous model, the dose uncertainties were categorized into space-oriented dose uncertainty (SOU) and nonspace-oriented dose uncertainty (NOU). The revised model further divided the uncertainty sources into planning and delivery. SOU and NOU associated with a planning system were defined as inherent dose uncertainty. A convolution method with seven degrees of freedom was also newly applied to generalize the model for practical clinical cases. The model parameters were quantified through a set of measurements, accumulated routine quality assurance (QA) data, and peer-reviewed publications. The predicted uncertainty maps were compared with dose difference distributions between computations and 108 simple open-field measurements using a two-dimensional diode array detector to verify the validity of the model parameters and robustness of the generalized model. To examine the applicability of the model to overall dose uncertainty prediction in IMRT, a retrospective analysis of QA measurements using the diode array detector for 32 clinical IM fields was also performed. A scatter diagram and a correlation coefficient were employed to investigate a correlation of the predicted dose uncertainty distribution with the dose discrepancy distribution between calculation and delivery. In addition, a {gamma} test was performed to correlate failed regions in dose verification with the dose uncertainty map. The quantified model parameters well correlated the predicted dose uncertainty with the probable dose difference between calculations and measurements. It was visually validated with the scatter diagrams. The average correlation coefficient between uncertainty and dose difference of 108 verification measurements was 0.80{+-}0.04, indicating a strong linear correlation. In the clinical IM field studies, the dose uncertainty map mimicked the probable dose difference distribution. The average correlation coefficient between the overall dose uncertainty and the dose difference of 32 QA measurements (total 13 184 comparison points) was 0.75{+-}0.07, which also indicated a strong linear correlation between them. The failed regions of the {gamma} test remarkably corresponded to relatively high dose uncertainty. In conclusion, the dose uncertainty map was able to highlight high dose uncertainty regions, where more care should be taken during the treatment plan. The a priori accurate prediction of dose uncertainty in IMRT will significantly improve the treatment plan evaluation process, thus improving the quality of radiation treatments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-P-28: A Method of Maximize the Noncoplanar Beam Orientations and Assure the Beam Delivery Clearance for Stereotactic Body Radiation Therapy (SBRT)

Purpose: Develop a method to maximize the noncoplanar beam orientations and assure the beam delivery clearance for SBRT, therefore, optimize the dose conformality to the target, increase the dose sparing to the critical normal organs and reduce the hot spots in the body. Methods: A SBRT body frame (Elekta, Stockholm, Sweden) was used for patient immobilization and target localization. The SBRT body frame has CT fiducials on its side frames. After patient’s CT scan, the radiation treatment isocenter was defined and its coordinators referring to the body frame was calculated in the radiation treatment planning process. Meanwhile, initial beam orientations were designed based on the patient target and critical organ anatomy. The body frame was put on the linear accelerator couch and positioned to the calculated isocenter. Initially designed beam orientations were manually measured by tuning the body frame position on the couch, the gantry and couch angles. The finalized beam orientations were put into the treatment planning for dosimetric calculations. Results: Without patient presence, an optimal set of beam orientations were designed and validated. The radiation treatment plan was optimized and guaranteed for delivery clearance. Conclusion: The developed method is beneficial and effective in SBRT treatment planning for individual patient. It first allows maximizing the achievable noncoplanar beam orientation space, therefore, optimize the treatment plan for specific patient. It eliminates the risk that a plan needs to be modified due to the gantry and couch collision during patient setup.

60 APPLIED LIFE SCIENCES↗

BEAM COLLIMATION IN THE PIP-II LINAC TO BOOSTER TRANSFER LINE

The new PIP-II superconducting linac will deliver a 2 mA average H⁻ beam to the existing Booster synchrotron. The injected beam is accumulated by charge exchange over approximately 300 turns; phase space painting is used to mitigate space charge effects. To limit the power load on the internal waste beam absorber from the transverse tails of the H⁻ distribution missing the foil, the beam will be collimated in both planes in the linac to Booster transfer line using compact collimators of a novel design. Both the number of parasitic hits and the fraction of the beam missing the foil are sensitive functions of the H⁻ beam centroid position with respect to the edge of the foil. The positioning of the collimation is constrained by the availability of suitable space in the transfer line lattice, by specifics of the collimator design, by the phase space orientation at the collimator, and by the betatron phase advance to the foil needed to achieve proper orientation of the spatial distribution at the injection point. In this contribution, we describe the procedure by which collimator positions were optimized. We then discuss the expected performance of the overall system.

Johnson, David E.↗

Subminiaturized gas chromatograph gives fast, efficient analysis

Space oriented, lightweight, subminiaturized gas chromatograph analyzes gas samples in a few seconds with a carrier gas flow of one milliliter per second. In extraterrestrial exploration, the system could be used with a mass spectrometer for detection of life-supporting compounds.

Wilhite, W. F.↗

A cloud-cover simulation procedure.

Worldwide cloud cover simulation procedure providing data for computer simulation of earth oriented space missions, describing computer program using Monte Carlo mission simulation

Brown, S. C.↗

Enhancement of Earth Resources Technology Satellite /ERTS/ and aircraft imagery using atmospheric corrections.

The studies considered are concerned with the magnitude of the atmospheric effects in multispectral earth resources data taken by satellites and aircraft. The atmospheric effects are present in all space oriented and aerial data even in the so-called atmospheric 'windows' through which all sensors observe the ground. Atmospheric effects are quite varied and depend on several parameters. An atmospheric model developed by Turner et al. (1971) is discussed. The model is applied to the test site, which is located in North Dakota. The results are used to obtain atmospheric correction data for ERTS-1 scanner data.

Sharma, R. D.↗

On visual-vestibular interaction

Experimental evidence is presented regarding visual vestibular interaction, and the results of three studies on the subject are briefly noted. An attempt to put together some of these observations with elementary notions of a visual vestibular interaction program is shown in the form of a flow chart representation of a possible model. This is a nonlinear model in which visual and vestibular influences are linearly weighted when they are in relative agreement but switch to the more believable one when they are in disagreement. A solution to the human space orientation problem is depicted by a schema for optimal subjective orientation based on several sensory modalities.

Young, L. R.↗

Skylab Fluid Mechanics Simulations: Oscillation, Rotation, Collision and Coalescence of Water Droplets Under Low-Gravity Environment

Skylab 4 crew members performed a series of demonstrations showing the oscillations, rotations, as well as collision coalescence of water droplets which simulate various physical models of fluids under low gravity environment. The results from Skylab demonstrations provide information and illustrate the potential of an orbiting space-oriented research laboratory for the study of more sophisticated fluid mechanic experiments. Experiments and results are discussed.

Otha H Vaughan, Jr↗

STS payloads mission control study (continuation phase)

User oriented space transportation system-payload mission control concepts are developed for optimum contribution of ground flight control support to onboard capability to meet STS payload objectives in a cost effective manner. Flight control ground functions are identified for representative payloads. Present and planned NASA facilities for payload control are investigated. Cost effective system concept options are determined for flight control of the payloads. Implementation guidelines are developed for proposed system concept options. Joint preflight activities are identified. Composite joint resources are identified.

Source record↗

Conceptual design of an on-board optical processor with components

The specification of components for a spacecraft on-board optical processor was investigated. A space oriented application of optical data processing and the investigation of certain aspects of optical correlators were examined. The investigation confirmed that real-time optical processing has made significant advances over the past few years, but that there are still critical components which will require further development for use in an on-board optical processor. The devices evaluated were the coherent light valve, the readout optical modulator, the liquid crystal modulator, and the image forming light modulator.

Walsh, J. R.↗

Technology Status: Fuel Cells and Electrolysis Cells

The status of the baselined shuttle fuel cell as well as the acid membrane fuel cell and space-oriented water electrolysis technologies are presented. The more recent advances in the alkaline fuel cell technology area are the subject of a companion paper. A preliminary plan for the focusing of these technologies towards regenerative energy storage applications in the multi-hundred kilowatt range is also discussed.

Mcbryar, H.↗

Microprocessor control for standardized power control systems

The use of microcomputers in space-oriented power systems as a replacement for existing inflexible analog type controllers has been proposed. This study examines multiprocessor systems, various modularity concepts and presents a conceptualized power system incorporating a multiprocessor controller as well as preliminary results from a breadboard model of the proposed system.

Green, D. G.↗

Full-coverage film cooling

Transpiration cooling is treated and then full coverage discrete hole injection for three injection orientations. Spacings with pitch to diameter ratios of 5 and 10 are discussed. The array is staggered, with the transverse pitch and the streamwise pitch the same. Results are presented in terms of the Stanton number using the heat transfer coefficient defined in terms of the difference between the wall temperature and the free stream temperature. Two values of Stanton number are provided for each situation: one with the injectant at wall temperature, and the other with the injectant at free stream temperature. These two values are equivalent to knowing the heat transfer coefficient and the adiabatic effectiveness. The heat transfer coefficient thus defined is used with the actual wall temperature to and the actual gas temperature to calculate the heat load. The principle of superposition thus invoked is valid exactly when the governing equations are linear.

Moffat, R. J.↗