Search NASA⌕ Search

SEARCH · Search NASA

Results for “STOPPING POWER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Characterization of high-flux cadmium zinc telluride detectors coupled to MM-PAD readout ASICs for high-flux X-ray applications

High-flux cadmium zinc telluride (HF-CZT) is a promising material for next-generation X-ray imaging due to its high stopping power, wide bandgap, and improved resistance to radiation-induced polarization [1]. We bonded 2 mm thick HF-CZT sensors with Cornell's Mixed-Mode Pixel Array ASICs, which combine analog charge integration and in-pixel digital counting to achieve single X-ray sensitivity, large full well capacity, and frame rates up to 10 kHz [2,3]. Detector characterization showed stable electron collection above 150 V bias, while hole collection remained limited by trapping even at 700 V. Temporal studies revealed non-negligible afterglow, with an unexpected increase in afterglow at higher biases, which was reduced by infrared illumination, suggesting that injected carriers reduce trapping near contact interfaces. Polarization measurements confirmed improved stability compared to conventional CZT, though polarization effects persisted, particularly with hole collection, with up to 5% signal loss and spatial distortion at high doses.

36 MATERIALS SCIENCE↗

A TOPAS model for lens-based proton radiography

Abstract Objective. Proton Radiography can be used in conjunction with proton therapy for patient positioning, real-time estimates of stopping power, and adaptive therapy in regions with motion. The modeling capability shown here can be used to evaluate lens-based radiography as an instantaneous proton-based radiographic technique. The utilization of user-friendly Monte Carlo program TOPAS enables collaborators and other users to easily conduct medical- and therapy- based simulations of the Los Alamos Neutron Science Center (LANSCE). The resulting transport model is an open-source Monte Carlo package for simulations of proton and heavy ion therapy treatments and concurrent particle imaging. Approach. The four-quadrupole, magnetic lens system of the 800-MeV proton beamline at LANSCE is modeled in TOPAS. Several imaging and contrast objects were modelled to assess transmission at energies from 230–930 MeV and different levels of particle collimation. At different proton energies, the strength of the magnetic field was scaled according to βγ, the inverse product of particle relativistic velocity and particle momentum. Main results. Materials with high atomic number, Z, (gold, gallium, bone-equivalent) generated more contrast than materials with low-Z (water, lung-equivalent, adipose-equivalent). A 5-mrad collimator was beneficial for tissue-to-contrast agent contrast, while a 10-mrad collimator was best to distinguish between different high-Z materials. Assessment with a step-wedge phantom showed water-equivalent path length did not scale directly according to predicted values but could be mapped more accurately with calibration. Poor image quality was observed at low energies (230 MeV), but improved as proton energy increased, with sub-mm resolution at 630 MeV. Significance. Proton radiography becomes viable for shallow bone structures at 330 MeV, and for deeper structures at 630 MeV. Visibility improves with use of high-Z contrast agents. This modality may be particularly viable at carbon therapy centers with accelerators capable of delivering high energy protons and could be performed with carbon therapy.

60 APPLIED LIFE SCIENCES↗

Development of an ab initio learned model of electron deposition range in deuterium-tritium plasmas through time-dependent density functional theory calculations and machine learning

Accurate hydrodynamic modeling for laser-direct-drive (LDD) inertial-confinement-fusion (ICF) relies on precise calculations of the electron thermal conduction in all target materials. The nonlocal stopping range of electrons in ICF plasmas directly influences thermal conduction; yet, no first principles model exists for the electron mean free path in the conduction-zone regime. This work utilized time-dependent stochastic density-functional theory (TD-sDFT) to calculate the electron stopping power in deuterium-tritium (DT) plasmas at (ρ, T) conditions relevant to the conduction zone and the compressed shell in ICF. Using a combination of our TD-sDFT data and already established analytical models, we developed and trained an artificial neural network to create a global model for the nonlocal electron deposition range, λ E . We compared our machine-learning (ML) based model for λ E to the currently-used modified-Lee-More model in LDD radiation-hydrodynamic codes, such as lilac, and saw an overall decrease in the deposition range. To understand the effects of λ E on LDD ICF implosion dynamics, we implemented the ML-based model into lilac; specifically, we looked at designs consistent with a current experiment on the OMEGA laser and for a newly designed LDD-ICF target for the future OMEGA-Next facility. In both cases, we saw an overall drop in predicted ablation pressure, peak areal density, and neutron yield due to the reduced thermal conduction (smaller λ E ) in DT plasmas. Comparisons with the experiment on OMEGA are also made.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modern version of the uncited 1938 experiment that first observed DT fusion

Experiments are described, and results are provided, for the duplication of the first-ever triton-deuterium (colloquially referred to as DT) fusion experiment accidentally performed by A.J. Ruhlig in 1938, but forgotten in the published scientific literature. Here, we find that Ruhlig overestimated the ratio of the triton-deuterium over deuteron-deuterium neutron yields in his secondary reaction (Reaction-in-Flight) experiment compared to modern theoretical calculations and our duplication of his experiment using modern neutron detection methods. Nevertheless, Ruhlig’s observation provided the motivation for the application of DT fusion after World War II and its more recent importance in peaceful energy production at DT fusion facilities around the world. Additionally, the experimental technique used in the present work provides a novel approach for checking on low-energy triton stopping powers in deuterium containing compounds.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Particle-in-cell simulations of burning inertial confinement fusion capsule implosions

Anomalies observed in the neutron spectral shift of high-yield shots at the National Ignition Facility (NIF) suggest the presence of suprathermal ions [E. P. Hartouni et al., Nat. Phys. 19, 72 (2023)], implying that kinetic effects play a significant role in burning inertial confinement fusion (ICF) plasmas. Furthermore, recent measurements of reaction-in-flight (RIF) neutrons offer a direct probe of the stopping power in the burning fuel region of high-energy alpha particles and up-scattered fuel ions. We have developed the particle-in-cell code PICNIC, an exactly energy-conserving particle-in-cell Monte-Carlo collision (PIC-MCC) code to simulate the burn stage in ICF. We present results from 1D spherical simulations of NIF shot N210808, which was the first to exceed the Lawson criterion for laser fusion. We find that the suprathermal ions generated by large-angle Rutherford and nuclear elastic scattering (NES) with fusion alphas produce an alpha knock-on neutron (AKN) signal consistent with the extent and relative yield of the AKN spectrum identified in ignition experiments at the NIF. Furthermore, we also find that the inclusion of large-angle scattering physics does not explain the anomalously large spectral shift observed in the experiment.

High-energy-density plasmas↗

The crystal structure of TlMgCl 3 from 290 K to 725 K

The title compound, thallium magnesium trichloride, has been identified as a scintillator with both moderate gamma-stopping power and moderate light yield. Knowledge of its crystal structure is needed for further development. This work determines the crystal structure of TlMgCl 3 to be hexa­gonal P6 3 /mmc (No. 194) and isostructural with RbMgCl 3 , contrary to previously reported data. This structure was obtained by single-crystal X-ray diffraction and was further confirmed by neutron diffraction measurements. Extending neutron diffraction measurements to high temperature, the data show that TlMgCl 3 maintains this crystal structure from 290 K up through 725 K, approaching the melting point of 770 K. Anisotropic thermal expansion coefficients increase over this temperature range, from 31 to 38 × 10 –6 K –1 along the a axis and from 19 to 34 × 10 –6 K –1 along the c axis.

36 MATERIALS SCIENCE↗

Particle-Tracking Proton Computed Tomography—Data Acquisition, Preprocessing, and Preconditioning

Proton CT (pCT) is a promising new imaging technique that can reconstruct relative stopping power (RSP) more accurately than x-ray CT in each cubic millimeter voxel of the patient. This, in turn, will result in better proton range accuracy and, therefore, smaller planned tumor volumes (PTV). The hardware description and some reconstructed images have previously been reported. In a series of two contributions, we focus on presenting the software algorithms that convert pCT detector data to the final reconstructed pCT images for application in proton treatment planning. There were several options on how to accomplish this, and we will describe our solutions at each stage of the data processing chain. In the first paper of this series, we present the data acquisition with the pCT tracking and energy-range detectors and how the data are preprocessed, including the conversion to the well-formatted track information from tracking data and water-equivalent path length from the data of a calibrated multi-stage energy-range detector. These preprocessed data are then used for the initial image formation with an FDK cone-beam CT algorithm. The output of data acquisition, preprocessing, and FDK reconstruction is presented along with illustrative imaging results for two phantoms, including a pediatric head phantom. The second paper in this series will demonstrate the use of iterative solvers in conjunction with the superiorization methodology to further improve the images resulting from the upfront FDK image reconstruction and the implementation of these algorithms on a hybrid CPU/GPU computer cluster.

42 ENGINEERING↗

Gamma-ray Spectra from a 3x3 CsPbBr 3 Array

CsPbBr 3 is a promising semiconductor material for X- and γ-ray detection at room temperature due to a wide bandgap of 2.3eV, high stopping power, and relatively high mobility-lifetime products of electrons and holes, and the capability of growing large crystals. In this paper we report on fabrication and testing of a 3.8 mm thick, 3 X 3 array with 1.2 mm pitch. Raw 137 Cs spectra were acquired with applied bias of 400 V, 500 V, and 600 V. Energy resolution of between 2 and 3 % FWHM at 662 keV was obtained from most pixels without any correction at room temperature. After 15 days under continuous bias at 600 V, no polarization effects were observed.

36 MATERIALS SCIENCE↗

Thermal Characterization of Tl 2 LiYCl 6 :Ce (TLYC)

Tl 2 LiYCl 6 :Ce (TLYC) is a new dual-detection elpasolite scintillator that can detect and distinguish between gamma rays and neutrons using pulse shape discrimination (PSD). It has a higher density and Z -number than the more mature and well-known elpasolite Cs 2 LiYCl 6 :Ce (CLYC), causing it to have a significantly better gamma-ray stopping power. These properties make TLYC an attractive alternative to CLYC for resource-constrained applications where size and weight are important, such as space or national security applications. Such applications may be subjected to a wide range of temperatures, and therefore, TLYC's performance was characterized for the first time over a temperature range of -20 °C to +50 °C in 10 °C increments. TLYC's thermal response effects on light-output linearity with energy, gamma-ray photopeak energy resolution, detected neutron energy, pulse shapes, and figure of merit (FOM) is analyzed and reported. The light output of TLYC was found to be linear with energy over the tested temperature range and was observed to decrease with increasing temperature. The decay time of the scintillation light output was observed to decrease with decreasing temperature at short times, leading to a decreasing PSD FOM. The gamma-ray photopeak energy resolution was also observed to degrade with decreasing temperature, due to an asymmetric broadening of the photopeak at low temperatures.

36 MATERIALS SCIENCE↗

Center-of-Mass Corrections in Associated Particle Imaging

Associated particle imaging (API) utilizes the inelastic scattering of neutrons produced in deuterium-tritium (DT) fusion reactions to obtain 3-D isotopic distributions within an object. The locations of the inelastic scattering centers are calculated by measuring the arrival time and position of the associated alpha particle produced in the fusion reactions, and the arrival time of the prompt gamma created in the neutron scattering event. While the neutron and its associated particle move in opposite directions in the center-of-mass (COM) system, in the laboratory system the angle is slightly less than 180°, and the COM movement must be taken into account in the reconstruction of the scattering location. Furthermore, the fusion reactions are produced by ions of different momenta, and thus the COM velocity varies, resulting in an uncertainty in the reconstructed positions. In this article, we analyze the COM corrections to this reconstruction by simulating the energy loss of beam ions in the target material and identifying sources of uncertainty in these corrections. Here we show that an average COM velocity calculated using the ion beam direction and energy can be used in the reconstruction and discuss errors as a function of ion beam energy, composition, and alpha detection location. When accounting for the COM effect, the mean of the reconstructed locations can be considered a correctable systematic error leading to a shift/tilt in the reconstruction. However, the distribution of reconstructed locations also have a spread that will introduce an error in the reconstruction that cannot be corrected. In this article, we will use the known stopping powers of ions in materials and reaction cross sections to examine the reconstruction uncertainties. We also discuss the impact of this effect on our API system.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Flash electropolishing for TEM: Reducing FIB‐induced defects in tungsten with protocols for new materials

Focused ion beam (FIB) milling has become the dominant approach for site-specific transmission electron microscopy (TEM) specimen preparation; however, FIB damage remains a critical limitation for reliable microstructural characterisation, particularly in radiation effects studies. Tungsten is especially susceptible to FIB damage due to its high nuclear stopping power, which promotes the formation and strong diffraction contrast of FIB-induced ‘black spot’ defects that are indistinguishable from very fine irradiation-induced loops/defects resulting from low to intermediate temperature neutron irradiation. In this work, flash electropolishing is systematically evaluated as a post-FIB treatment for minimising preparation-induced artefacts for TEM analysis of tungsten-based alloys. Using a range of non-, ion-, and neutron-irradiated tungsten materials, the effectiveness of flash electropolishing has been assessed through direct comparison with conventional FIB and plasma-FIB preparation including low-energy Ga, Ar, Xe ion cleaning. The results demonstrate that flash electropolishing effectively removes FIB-damaged layers and ‘black spot’ defects, thereby enabling reliable observation of irradiation-induced dislocation structures. Key processing parameters governing flash electropolishing quality – including lamella thickness, applied voltage, polishing duration, electrolyte chemistry, and cathode geometry – have been systematically evaluated, and clear criteria were established for determining when flash electropolishing is required to ensure reliable microstructural analysis. This work also provides practical guidance for implementing flash electropolishing as an artefact-controlled specimen-preparation approach for TEM characterisation of FIB-produced specimens. The systematic protocol can be extended to other, non-tungsten materials.

TEM sample preparation↗

Gold leaf phantom development for the assessment of proton radiographic sensitivity limits simulating gold nanoparticle tagged tumors

Proton radiography may guide proton therapy cancer treatments with beam’s-eye-view anatomical images and a proton-based estimation of proton stopping power. However, without contrast enhancement, proton radiography will not be able to distinguish tumor from tissue. To provide this contrast, functionalized, high-Z nanoparticles that specifically target a tumor could be injected into a patient before imaging. We conducted this study to understand the ability of gold, as a high-Z, biologically compatible tracer, to differentiate tumors from surrounding tissue. We indicate that AuNP-enhanced proton radiography might be a feasible technology to provide image-guidance to proton therapy, potentially reducing off-target effects and sparing nearby tissue. These data can be used to develop treatment plans and clinical applications can be derived from the simulations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Real-time time-dependent density functional theory in Quantum Espresso and related codes

A set of subroutines that interact with an existing computer program, Quantum Espresso (QE), that takes a set of electronic orbitals from QE and propagates them forward in time in response to a number of perturbations. These perturbations include the motion of ions and a wide spectrum of applied electromagnetic fields (e.g., static magnetic fields, slowly-varying electric fields, x-rays, etc.). From the time evolution of the electronic orbitals comes time-varying values of physical observables like the electronic charge and current densities and atomic forces. These are further post-processed to yield properties of interest like stopping powers, conductivities, and the dynamic structure factor. The electronic orbitals are described in a plane wave basis and the equations of motion are carried out using a unitary or approximately unitary time propagation algorithm. Related work will include subroutines for interfacing this capability, as well as others that already exist within QE, with a fork of QE that is more extensible and modular.SAND2019-12611 M Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-NA0003525.

Baczewski, Andrew↗

SOURCES4D

SOURCES is a code for computing neutron source rates and spectra from spontaneous fission (including delayed neutrons) and (alpha,n) reactions in homogeneous materials and (alpha,n) reactions in single-interface and two-interface geometries. SOURCES is a Los Alamos National Laboratory (LANL) code that is written in FORTRAN and distributed through the Radiation Safety Information Computation Center (RSICC). LANL’s last release of SOURCES to RSICC was SOURCES4C in 2002. This disclosure covers the latest version of SOURCES, SOURCES4D. This version adds sensitivity capabilities for (alpha,n) sources in homogeneous materials. Specifically, SOURCES4D writes new output that can be used to calculate, in post-processing, first and second derivatives of the (alpha,n) source rate density and spectrum with respect to nuclide densities in a homogeneous material and first derivatives of the (alpha,n) source rate density and spectrum with respect to nuclide stopping powers and (alpha,n) cross sections (nuclear data). These derivatives are useful for uncertainty quantification, predictive modeling, and other applications in neutron transport problems.

Favorite, Jeffrey A.↗

Fabrication of Low-Cost Large-Volume Ceramic A 2 HfX 6 (A= Cs or Tl, X = Cl, Br, or I) Scintillators for Gamma Ray Detection (SBIR Phase I Final Technical Report)

Scintillator crystals play an important role in the radiation detection field. Widespread use of scintillators as gamma-ray detectors is largely generated by their extensive availability and tunable properties, such high light output, high stopping power (Z eff ), fast decay time, and good proportionality. Additionally, the cost for manufacturing a scintillation detector like NaI:Tl is usually considerably lower than the cost for manufacturing a semiconductor detector like CdZnTe. Because there is no such thing as an ideal scintillation material, an application requiring certain detection characteristics may incorporate a scintillator tailored to its specific properties. The vast variety of applications and requirements necessitates more research into new scintillation materials and/or better methods of producing existing materials.The goal of this project was to grow low cost and environmentally stable inorganic transparent ceramic scintillators with excellent gamma ray resolution, excellent energy proportionality, excellent detection efficiency due to high density (>5 g/cm 3 ) and very high Z eff (55-80), and good light yields (>40,000 ph/MeV). In Phase I Xtallized Intelligence, Inc. (XI, Inc) developed a novel ceramic fabrication technique to produce low cost and environmentally stable highly efficient inorganic transparent ceramic scintillators of various dimensions. XI, Inc., collaborating with Fisk University (Fisk), investigated the scintillation properties of these new ceramic scintillators and compared them to in their single crystal counterparts. The results of this Phase I project show that successful production of high-quality inorganic halide ceramic scintillators Cs 2 HfCl 6 (CHC) and Tl 2 HfCl 6 (THC). Both ceramic CHC and THC scintillators have achieved good performance close to the performance of their single crystal counterparts. Fabricating these inorganic ceramic scintillators mitigate many issues encountered during conventional bulk crystal growth by melt methods. Additional benefits of the ceramic fabrication technique include high production yield, low production cost, fast production time, and no material waste Inorganic transparent ceramic scintillators produced in this project will enhance cost effectiveness at the instrument level based on low projected cost of the proposed compounds, as much smaller crystal sizes would be required to achieve similar efficiency as current radioisotope identification devices (RIID’s) used in homeland security applications as well as spectrometers in high energy physics applications.

36 MATERIALS SCIENCE↗

Release of the NDI 2.2.0

The Nuclear Data Interface 2.2.0 has been released. It includes the addition of charged particle dE/dx (stopping power) data, the ability to read in NDI-formatted binary data, corrections to TN data, and other minor changes and bug fixes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Release of the NDI 2.2.0alpha

The Nuclear Data Interface 2.2.0alpha has been released. It includes the addition of charged particle dE/dx (stopping power) data, the ability to read in NDI-formatted binary data, corrections to TN data, CP 2011 and CP 2020 data, and other minor changes and bug fixes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Transport Properties of Magnetized High-Energy Density Plasma (Final Project Report)

This report summarizes results of project DE-SC0016159 "Transport Properties of Magnetized High-Energy-Density Plasma,'' which ran from 7/15/2016 - 7/14/2021. The primary objectives of the work, as stated in the original proposal, were to develop a theory that describes transport coefficients in magnetized high energy density plasmas and to test the theory with molecular dynamics (MD) simulations. The science challenge is that strong ion coupling, strong magnetization of electrons, and partial degeneracy of electrons, cause the system to be in a regime that is not well described by current theory. The particular processes that were to be investigated include: ion stopping power, diffusion, electron-ion temperature relaxation, thermal conduction and viscosity. All of the primary research objectives were accomplished during the course of this work. In addition, some unexpected results were discovered along the way that led to new and productive research directions. This work resulted in 17 publications in well-respected peer-reviewed journals (primarily Physics of Plasmas and Physical Review E), and 2 more are being prepared for publication. A few of these were selected as Editor's Picks and one was published as a Rapid Communication. Highlights of the research results include: Transport phase space: The first identification of the parameter space that defines fundamental transport regimes in terms of the Coulomb coupling and magnetization parameters. Mean force kinetic theory: Systematic derivation of a kinetic theory for strongly coupled plasmas based on a new expansion parameter of the BBGKY hierarchy. This provided the derivation of a theory that we had previously posed phenomenologically, and also revealed a new term that captures the equation of state properties at all coupling strengths. Transverse friction force: Discovery that the friction force on a test charge in a strongly magnetized plasma includes a component that is perpendicular to the motion of the test charge in the plane defined by the velocity and magnetic field vectors. Gyrofriction force: Discovery that the friction force on a test charge in a plasma that is both strongly magnetized and strongly coupled includes a component of the force in the direction of the Lorentz force. Kinetic theory for warm dense matter: Extension of the mean force kinetic theory to include partial electron degeneracy, so that it applies to warm dense matter.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗