Search NASA⌕ Search

SEARCH · Search NASA

Results for “STORAGE STABILITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Integrated Power and Attitude Control System (IPACS)

Recent advances in materials, circuit integration and power switching have given the concept of dynamic energy and momentum storage important weight size, and operational advantages over the conventional momentum wheel-battery configuration. Simultaneous momentum and energy storage for a three axes stabilized spacecraft can be accomplished with a topology of at least four wheels where energy (a scalar) is stored or retrieved in such a manner as to keep the momentum vector invariant. This study, instead, considers the case of two counter-rotating wheels in one axis to more effectively portray the principles involved. General scalable system design equations are derived which demonstrate the role of momentum storage when combined with energy storage.

Michaelis, Theodore D.↗

Application of low dissipation and dispersion Runge-Kutta schemes to benchmark problems in computational aeroacoustics

We investigate accurate and efficient time advancing methods for computational aeroacoustics, where non-dissipative and non-dispersive properties are of critical importance. Our analysis pertains to the application of Runge-Kutta methods to high-order finite difference discretization. In many CFD applications, multi-stage Runge-Kutta schemes have often been favored for their low storage requirements and relatively large stability limits. For computing acoustic waves, however, the stability consideration alone is not sufficient, since the Runge-Kutta schemes entail both dissipation and dispersion errors. The time step is now limited by the tolerable dissipation and dispersion errors in the computation. In the present paper, it is shown that if the traditional Runge-Kutta schemes are used for time advancing in acoustic problems, time steps greatly smaller than that allowed by the stability limit are necessary. Low Dissipation and Dispersion Runge-Kutta (LDDRK) schemes are proposed, based on an optimization that minimizes the dissipation and dispersion errors for wave propagation. Optimizations of both single-step and two-step alternating schemes are considered. The proposed LDDRK schemes are remarkably more efficient than the classical Runge-Kutta schemes for acoustic computations. Numerical results of each Category of the Benchmark Problems are presented. Moreover, low storage implementations of the optimized schemes are discussed. Special issues of implementing numerical boundary conditions in the LDDRK schemes are also addressed.

Hu, F. Q.↗

Quantitative Analysis of Spaceflight Drug Stability Data to Support a Predictive Pharmaceutical Testing Strategy

To systematically quantify the time-dependent effect of spaceflight on active pharmaceutical ingredient (API) degradation, data were extracted from available published and unpublished spaceflight drug stability studies. Seven studies were identified that investigated the stability of individual medications following storage aboard crewed spacecraft. Medications stored for up to 2.4 years in low earth orbit (LEO) show limited change in API potency that, in all cases, falls within 10% of matched terrestrial controls, and within 5% of controls for the most drugs. This investigation shows that spaceflight is associated with a ~1.5-fold increase in the degradation rate relative to lot-matched terrestrial controls. Spaceflight is associated with an increased probability of drug failure over time; however, the incremental increase in degradation risk associated with spaceflight is minor compared to the baseline risk associated with terrestrial controls. Since most drugs across all NASA-supported studies were repackaged solid oral formulations that had been removed from protective manufacturer packaging, it is likely that prolonged exposure to atmospheric factors during both terrestrial and spaceflight treatments is a key contributor to degradation. Unique spaceflight environmental factors, particularly ionizing radiation and elevated CO2, may contribute to the additional cumulative effect of spaceflight. The results of this study show that the effect of spaceflight on drug stability is minor relative to the terrestrial baseline; however, the degradation rate and time-dependent failure of terrestrial controls highlights an extremely critical need to evaluate the effect of current repackaging methods and development of operationally appropriate methods to protected repackaged solid oral medications from environmental factors that mediate degradation.

J F Reichard↗

An empirical approach to predicting long term behavior of metal particle based recording media

Alpha iron particles used for magnetic recording are prepared through a series of dehydration and reduction steps of alpha-Fe2O3-H2O resulting in acicular, polycrystalline, body centered cubic (bcc) alpha-Fe particles that are single magnetic domains. Since fine iron particles are pyrophoric by nature, stabilization processes had to be developed in order for iron particles to be considered as a viable recording medium for long term archival (i.e., 25+ years) information storage. The primary means of establishing stability is through passivation or controlled oxidation of the iron particle's surface. A study was undertaken to examine the degradation in magnetic properties as a function of both temperature and humidity on silicon-containing iron particles between 50-120 C and 3-89 percent relative humidity. The methodology to which experimental data was collected and analyzed leading to predictive capability is discussed.

Hadad, Allan S.↗

Alkali-metal silicate binders and methods of manufacture

A paint binder is described which uses a potassium or sodium silicate dispersion having a silicon dioxide to alkali-metal oxide mol ratio of from 4.8:1 to 6.0:1. The binder exhibits stability during both manufacture and storage. The process of making the binder is predictable and repeatable and the binder may be made with inexpensive components. The high mol ratio is achieved with the inclusion of a silicon dioxide hydrogel. The binder, which also employs a silicone, is in the final form of a hydrogel sol.

Schutt, J. B.↗

Reliability Issues with Polymer and MnO2 Tantalum Capacitors for Space Applications

This presentation gives a comparative analysis of degradation processes, failure modes and mechanisms in MnO2 and polymer technology capacitors. Analyzed conditions include effects of vacuum and radiation, soldering (pop-corning), long-term storage, operation at high temperatures, stability at low and high temperatures, and anomalous transients. Screening and qualification procedures to assure space-grade quality of CPTCs are suggested.

capacitor↗

Dry Saliva Development-Artemis

Prior to the deployment of prolonged deep space missions which may carry increased crew health risks, it is essential to determine the effect that missions beyond the Van Allen Belt will have on physiology. Historically the National Aeronautics and Space Administration (NASA), Human Research Program (HRP) has developed, conducted, and delivered research findings and countermeasures that will maintain the health and safety of crews aboard the International Space Station (ISS) in anticipation of future exploration class missions. To support these objectives, research operations on ISS typically include the collection and storage of human physiological samples and their return to Earth for analysis. Transition to Gateway and Artemis lunar exploration will limit the available up mass and biosample return capability resulting in new challenges to monitor crew health during the mission. The Artemis lunar missions provide a perfect opportunity to assess new technology that could support crew biosample return that is compatible with the severe operational constraints of Artemis mission design. Dried biosample chemistry analysis is a potential technology that can enable the collection of samples and tracking of crew health during these exploration class missions. The development and implementation of dried biosample chemistry technology for tracking immune health, viral reactivation and hormone fluctuations provide a simple alternative strategy for sample collection and sample return (light weight non-conditioned stowage option) for the continuation of human research during Artemis missions. Saliva is established as an informative biosample that has both its own unique available analytes as well as others that are also present in blood. Saliva is already routinely collected from ISS astronauts for the detection of stress hormones and latent virus DNA. The ‘Dry Saliva’ book sample collection/storage protocol, already successfully deployed to ISS, represents a perfect method for collecting biosamples from Gateway and Artemis astronauts because it requires a simple, non-invasive sample collection protocol, minimum volume, and uses non-conditioned storage. We are currently conducting an expanded stability study of the dry saliva analyte platform to include additional stress hormones, cytokines, antimicrobial proteins, and latent virus DNA as well as other markers of immunity and inflammation. Validation testing on parabolic flight will establish collection methods for saliva and blood to dry sampling substrates to finalize the collection protocols for flight. For the new expanded analyte stability study, a short-term stability study with time points out to 14 days has been completed with analysis underway to determine whether additional analytes could be recovered, as well as assessing the best storage conditions for the samples collected. In parallel, a long-term stability study is being conducted out to 1 year to improve the stability of some unstable analytes. To this end, the NASA Johnson Space Center’s Immunology/Virology lab is currently finalizing the saliva dry chemistry platform, including assay compatibility and stability studies. This technology is approved to be implemented, as part of the ‘Biomarkers’ study, during Artemis II through Artemis IV lunar missions.

Mayra Nelman-Gonzalez↗

Stability of Co-gamma-Fe2O3 tape

The viewgraphs of a discussion on the stability of recording media presented at the National Space Science Data Center (NSSDC) Mass Storage Workshop is included. An overview of archival stability of recording media is presented. Co-gamma-Fe2O3 tape is discussed. Other topics covered are magnetic tape components, dimensional stability and crossply, acetone extraction, coercivity, and phi R percent change.

Carlson, Darlene M.↗

Benchmarking Computational Tools for Calling SNPs and Indels in Complex Microbial Populations

The NASA BioNutrients missions seek to understand the suitability of microorganisms for bioproduction during space flight. One topic of interest is the stability of microbial genomes during long-term ambient storage and subsequent rehydration and growth. To address these questions, samples from 8 species were flown to ISS for 5 years of desiccated storage at ambient temperature (Stasis Packs) and 2 species were packaged along with powdered media inside a bioreactor system to allow hydration and growth in microgravity (Production Packs). For both systems, Whole Genome Sequencing (WGS) of the DNA extracted from the returned samples and paired ground controls will be conducted to identify changes in genome stability due to time, storage conditions and growth in space. Across the technical replicates, ground controls, 10 timepoints, and multiple experimental conditions, ~300 samples have been selected for initial analysis with WGS sequencing to 100x coverage. A flexible and resource efficient mutation calling pipeline is needed to process this large dataset and allow for comparisons between species. Many bioinformatics tools for calling Indels and Single Nucleotide Variants (SNVs) are designed for use with pure isolates, where true variations from the reference genome are expected to dominate the reads aligning to the location of mutation. In contrast, DNA from the Stasis Pack (SP) samples was collected directly after recovery from desiccated storage and the Production Pack (PP) samples were collected after fermentation. In this context, reads with mutations are expected to be less frequent than reads that align with the reference genome, as each sample will include multiple lines of cells. Thus, BioNutrients samples are expected to be similar to samples from cancer cell or “pooled” sequencing approaches. In preparation for the analysis of the BioNutrients samples, we have tested three mutation calling tools (GATK for Microbes, BreSeq and DiscoSNP) designed for complex samples. A challenge of validating mutation identification pipelines is a lack of “Ground Truth” datasets, especially for complex samples. To compare these three tools, we sought to identify mutations in pre-existing WGS data collected from populations of Chlamydomonas reinhardtii that were exposed to UV mutagenesis and growth in LEO as part of the Space Algae-1 mission. Here we present a summary of these tools against the analysis originally conducted using the CRISP tool. Critical metrics are compared such as runtime, the number of SNPs, the number and size of Indels, and patterns of transversion and transitions identified by each tool are reported. By sharing these benchmarking results collected in support of the BioNutrients mission, we aim to guide others seeking to identify SNVs in similarly complex microbial samples.

Biology↗

Long-term risk analysis associated with nuclear waste disposal in space

An assessment and verification of previous analytic results on the long term risk of earth reentry for hazardous payloads is presented. The two areas were studied: (1) stability of nominal, near-circular storage orbits in the regions between Venus and earth and between earth and Mars, and (2) probability of earth reentry for off-nominal planet-crossing orbits resulting from deployment system failures. In the first area, numerical integrations of the equations of motion are compared with stability predications based on secular perturbation theory. The agreement is good in terms of the heliocentric distances covered and the general behavior of the orbital history, although certain near-resonance situations can lead to difficulty. In the second area, a Monte Carlo simulation of orbital evolution is used and the results compared with Opik's analytic theory of planetary encounters and collision statistics, with data verified to within a close order-of-magnitude.

Friedlander, A. L.↗

The Stability of Bioactive Compounds in Spaceflight Foods

The status and stability of bioactive compounds in the processed and shelf-stable spaceflight food system have not previously been investigated though the presence of such compounds in aged space foods could have health significance for crews on long duration exploration missions. Over forty foods - either existing International Space Station (ISS) food provisioning items, newly developed foods for spaceflight, or commercially-available ready-to-eat foods - that were predicted to have a relatively high concentrations of one or more bioactive compounds (lycopene, lutein, omega-3 fatty acids, phenolics, sterols, and/or flavonoids) were selected for the study. Food samples were sent overnight to the Food Composition Laboratory of the Linus Pauling Institute at Oregon State University (Corvallis, OR) for bioactive compound analysis. Three packages of each product were blended together for the analysis to reduce package-to-package variability. All ISS food items and commercial foods were analyzed initially and after 12 and 24 months of 21degC storage. Food development occurred in a staggered fashion, so data collection for the newly developed foods continues. Lastly, sensory evaluation and additional temperature storage data (4degC, 35degC) for select foods were collected to establish additional stability parameters. Efficacious concentrations of lycopene, lutein, and omega-3 fatty acids were measured in limited spaceflight foods; two grams of sterols a day may be difficult to achieve with the current space diet. Total polyphenol delivery appears stable and adequate, but individual phenolic compounds vary in stability and were not specifically evaluated in this study. The data suggests that some bioactive compounds, like lycopene and lutein, degrade and then plateau at some equilibrium concentration. The anthocyanin stability appears to be related to storage temperature and food matrix, and lutein stability in leafy vegetables may be impacted by storage temperature. Because of the limited number of foods with high concentrations of the bioactive compounds, additional menu variety, formulation optimization, and reduced temperature storage will be required to ensure delivery of several bioactive compounds in the space food system. Validation of stability to five years will enable provisioning of these functional foods within the space food system for a mission to Mars.

Cooper, M. R.↗

Subcontracted activities related to TES for building heating and cooling

The subcontract program elements related to thermal energy storage for building heating and cooling systems are outlined. The following factors are included: subcontracts in the utility load management application area; life and stability testing of packaged low cost energy storage materials; and development of thermal energy storage systems for residential space cooling. Resistance storage heater component development, demonstration of storage heater systems for residential applications, and simulation and evaluation of latent heat thermal energy storage (heat pump systems) are also discussed. Application of thermal energy storage for solar application and twin cities district heating are covered including an application analysis and technology assessment of thermal energy storage.

Martin, J.↗

Eighth Goddard Conference on Mass Storage Systems and Technologies in Cooperation with the Seventeenth IEEE Symposium on Mass Storage Systems

This document contains copies of those technical papers received in time for publication prior to the Eighth Goddard Conference on Mass Storage Systems and Technologies which is being held in cooperation with the Seventeenth IEEE Symposium on Mass Storage Systems at the University of Maryland University College Inn and Conference Center March 27-30, 2000. As one of an ongoing series, this Conference continues to provide a forum for discussion of issues relevant to the management of large volumes of data. The Conference encourages all interested organizations to discuss long term mass storage requirements and experiences in fielding solutions. Emphasis is on current and future practical solutions addressing issues in data management, storage systems and media, data acquisition, long term retention of data, and data distribution. This year's discussion topics include architecture, future of current technology, new technology with a special emphasis on holographic storage, performance, standards, site reports, vendor solutions. Tutorials will be available on stability of optical media, disk subsystem performance evaluation, I/O and storage tuning, functionality and performance evaluation of file systems for storage area networks.

Kobler, Benjamin↗

Single-state selection system for hydrogen masers

The design and operation of a single-state selection system based on the adiabatic fast-passage technique for atomic state inversion is described. The system uses a variable-pitch dc solenoid and orthogonal four-wire RF coil to create the state-changing magnetic fields, and a half-wavelength state selection magnet to remove the inverted state atoms from the hydrogen beam. The system's performance was determined by measuring maser power as a function of line Q. The system removes more than 85 percent of undesired atoms from the beam. The potential effects of improvements in the maser on its frequency stability have been calculated. The use of single-state selection combined with increased RF coupling to the cavity and increased storage bulb collimation offers the possibility of frequency stability in the 10 to the -17th regime over intervals on the order of 60,000 s.

Mattison, Edward M.↗

Flexible bulb large storage box hydrogen maser

The principal limitation on the accuracy of the hydrogen maser as a primary frequency standard has been the irreproducibility of the frequency shift caused by collisions of the radiating atoms with the walls of the vessel containing them. The flexible bulb-large storage box hydrogen maser allows correction for this wall shift within a single device, sidestepping the reproducibility problem, and reducing the frequency error from the wall shift to the level imposed by the device's stability. The principles of the device are discussed including the flexible bulb technique and the complications caused by a multiple region storage bulb. The stability of the device is discussed including a comparison with an ordinary hydrogen maser. Data is presented from a working flexible bulb-large storage box hydrogen maser demonstrating the feasibility of the device and showing some of its operating characteristics. The flexibility of the device is demonstrated by showing how the device's added degrees of freedom allow measurement of parameters unmeasurable in an ordinary hydrogen maser.

Reinhardt, V.↗

Dish-mounted latent heat buffer storage

Dish-mounted latent heat storage subsystems for Rankine, Brayton, and Stirling engines operating at 427 C, 816 C, and 816 C respectively are discussed. Storage requirements definition, conceptual design, media stability and compatibility tests, and thermal performance analyses are considered.

Manvi, R.↗

Cognitive performance deficits in a simulated climb of Mount Everest - Operation Everest II

Cognitive function at simulated altitude was investigated in a repeated-measures within-subject study of performance by seven volunteers in a hypobaric chamber, in which atmospheric pressure was systematically lowered over a period of 40 d to finally reach a pressure equivalent to 8845 m, the approximate height of Mount Everest. The automated performance test system employed compact computer design; automated test administrations, data storage, and retrieval; psychometric properties of stability and reliability; and factorial richness. Significant impairments of cognitive function were seen for three of the five tests in the battery; on two tests, grammatical reasoning and pattern comparison, every subject showed a substantial decrement.

Kennedy, R. S.↗