Search NASA⌕ Search

SEARCH · Search NASA

Results for “SUPPRESSOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Characteristics of internal- and jet-noise radiation from a multi-lobe, multi-tube suppressor nozzle tested statically and under flight simulation

Nozzle transmission coefficient (NTC) for a 12-lobe, 24-tube suppressor nozzle and a reference round convergent nozzle of equal area are obtained by an impulse test technique. This technique utilizes a high voltage spark discharge as a noise source within the test duct. Effects of nozzle geometry, jet Mach number, jet temperature and flight velocity on the radiation characteristics of the two nozzles are presented. Likewise, the jet mixing noise measured in the absence of internal noise for both nozzles at static and also simulated flight conditions are discussed.

Ahuja, K. K.↗

Aeroacoustics of a porous plug jet noise suppressor

The aeroacoustics of a porous plug jet noise suppressor was investigated. The predicted flow features of isentropic plug nozzles for different pressure ratios or exit flow Mach numbers, throat areas, ratios of the plug to annular nozzle radii, mass flow rates and the available run times possible with the existing compressed air supply system, are compiled. The dimensions and the coordinates of the contour of typical isentropic external expansion plugs with different exit flow Mach numbers are listed. Design details of the experimental facility and the plug nozzle selected for experimental aeroacoustic studies are reported. The analytical flow prediction by method of characteristics of a conical porous plug nozzles is initiated. The role of the shape, size, and porosity of the plug surface in achieving over a perforated conical plug a nearly isentropic shockfree supersonic flow field which is closely similar to the flow field of a contoured isentropic plug nozzle is examined.

Dosanjh, D. S.↗

Acoustic performance of inlet suppressors on an engine generating a single mode

Three single degree of freedom liners with different open area ratio face sheets were designed for a single spinning mode in order to evaluate an inlet suppressor design method based on mode cutoff ratio. This mode was generated by placing 41 rods in front of the 28 blade fan of a JT15D turbofan engine. At the liner design this near cutoff mode has a theoretical maximum attenuation of nearly 200 dB per L/D. The data show even higher attenuations at the design condition than predicted by the theory for dissipation of a single mode within the liner. This additional attenuation is large for high open area ratios and should be accounted for in the theory. The data show the additional attenuation to be inversely proportional to acoustic resistance. It was thought that the additional attenuation could be caused by reflection and modal scattering at the hard to soft wall interface. A reflection model was developed, and then modified to fit the data. This model was checked against independent (multiple pure tone) data with good agreement.

Heidelberg, L. J.↗

Jet noise results from static, wind tunnel, and flight tests of conical and mechanical suppressor nozzles

Results of jet noise suppression tests conducted on a Rolls-Royce Viper 601 turbojet engine are reported. Seven exhaust nozzle configurations are tested, including two conical nozzles, two suppressor mixers, and three treated ejector configurations with different ejector inlets. Tests are conducted at the NASA Ames outdoor static test facility and the 40- by 80-ft wind tunnel facility at minimum tunnel flow velocity and normal flow velocities of 230 and 290 ft/sec. Near-field multiple sideline noise levels are projected to the far fields to compare far-field fixed microphone outdoor static noise levels, and wind tunnel near-field noise data are projected to the far field and flight distances to compare with noise levels recorded from an Hs-125 aircraft. Near-field outdoor noise data duplicate the far-field data recorded from fixed microphones within 2 PNdB, and the Douglas mechanical jet noise suppressor/treated ejector exhaust system achieves a noise reduction of 12 EPNdB relative to a conic reference nozzle at equal thrust in flight.

Mckinnon, R. A.↗

A model for the acoustic impedance of linear suppressor materials bonded on perforated plate

An analytical model is developed for the acoustic impedance of a composite made of a fine screen bonded to a perforated plate, the resistance having been modeled using steady flow theory and data, and including both linear and nonlinear components. The model of the screen resistance alone is derived first, and it is then extended to include a perforated plate bonded to the screen. Quantities such as effective open ratio and pressure recovery are evaluated. Conclusions are presented, including: (1) when the screen is bonded to a perforated plate, the linear resistance increases as the inverse of the perforate open area, (2) the nonlinearity in the screen resistance depends on the square of the screen wire diameter, and (3) when the resistance is considered as a function of approach velocity, the screen nonlinear term increases as the inverse of the square of the perforated plate open area ratio. The general theory can be applied to any screen structure, but final results are limited to a twilled square weave screen. Results can be applied to the study of sound absorbing materials used for lining the walls of aircraft engine duct suppressors.

Rice, E. J.↗

Acoustic performance of inlet suppressors on an engine generating a single mode

As part of a program to evaluate an inlet suppressor design method based on mode cutoff ratio, three single degree of freedom liners with different open area ratio face sheets were designed for a single spinning mode. This mode was generated by placing 41 rods in front of the 28 blade fan of a JT15D turbofan engine. At the liner design this near cutoff mode has a theoretical maximum attenuation of nearly 200 dB per L/D. The data show even higher attenuations at the design condition than predicted by the theory for dissipation of a single mode within the liner. This additional attenuation is large for high open area ratios and should be accounted for in the theory. The data shows the additional attenuation to be inversely proportional to acoustic resistance. It was thought that the additional attenuation could be caused by reflection and modal scattering at the hard to soft wall interface. A reflection model was developed, and then modified to fit the data. This model was checked against independent (multiple pure tone) data with good agreement.

Heidelberg, L. J.↗

Aeroacoustics of a porous plug supersonic jet noise suppressor

The aeroacoustics of a porous plug supersonic jet noise suppressor was investigated. The needed modifications of the existing multistream coaxial jet rig; the compressed air facility and pressure controls; the design, the fabrication, and the installation of the plenum chamber for the plug nozzle, and the design and the machining of the first contoured plug nozzle were completed. The optical and the aeroacoustic data of the contoured plug nozzles and of the conical convergent nozzle alone were discussed.

Dosanjh, D. S.↗

Six-Degree-of-Freedom Vibration Suppressor

New system, total-rotor-isolation system (TRIS) employs liquid-inertia vibration-eliminator (LIVE) units, designed to isolate all six degrees of freedom of aircraft-fuselage dynamic response from continuously changing airloads developed by rotor. Vibration suppressor uses liquid mercury to damp vibrations. Results of flight tests indicated at least 95-percent reduction in vibration levels from rotor hub to pilot's seat.

Halwes, Dennis R.↗

Aerodynamic performance investigation of advanced mechanical suppressor and ejector nozzle concepts for jet noise reduction

Advanced Supersonic Transport jet noise may be reduced to Federal Air Regulation limits if recommended refinements to a recently developed ejector shroud exhaust system are successfully carried out. A two-part program consisting of a design study and a subscale model wind tunnel test effort conducted to define an acoustically treated ejector shroud exhaust system for supersonic transport application is described. Coannular, 20-chute, and ejector shroud exhaust systems were evaluated. Program results were used in a mission analysis study to determine aircraft takeoff gross weight to perform a nominal design mission, under Federal Aviation Regulation (1969), Part 36, Stage 3 noise constraints. Mission trade study results confirmed that the ejector shroud was the best of the three exhaust systems studied with a significant takeoff gross weight advantage over the 20-chute suppressor nozzle which was the second best.

Wagenknecht, C. D.↗

A role for cyclin-dependent kinase(s) in the modulation of fast anterograde axonal transport: effects defined by olomoucine and the APC tumor suppressor protein

Proteins that interact with both cytoskeletal and membrane components are candidates to modulate membrane trafficking. The tumor suppressor proteins neurofibromin (NF1) and adenomatous polyposis coli (APC) both bind to microtubules and interact with membrane-associated proteins. The effects of recombinant NF1 and APC fragments on vesicle motility were evaluated by measuring fast axonal transport along microtubules in axoplasm from squid giant axons. APC4 (amino acids 1034-2844) reduced only anterograde movements, whereas APC2 (aa 1034-2130) or APC3 (aa 2130-2844) reduced both anterograde and retrograde transport. NF1 had no effect on organelle movement in either direction. Because APC contains multiple cyclin-dependent kinase (CDK) consensus phosphorylation motifs, the kinase inhibitor olomoucine was examined. At concentrations in which olomoucine is specific for cyclin-dependent kinases (5 microM), it reduced only anterograde transport, whereas anterograde and retrograde movement were both affected at concentrations at which other kinases are inhibited as well (50 microM). Both anterograde and retrograde transport also were inhibited by histone H1 and KSPXK peptides, substrates for proline-directed kinases, including CDKs. Our data suggest that CDK-like axonal kinases modulate fast anterograde transport and that other axonal kinases may be involved in modulating retrograde transport. The specific effect of APC4 on anterograde transport suggests a model in which the binding of APC to microtubules may limit the activity of axonal CDK kinase or kinases in restricted domains, thereby affecting organelle transport.

Non-NASA Center↗

Aero-acoustic design and test of a multiple splitter exhaust noise suppressor for a 0.914m diameter lift fan

A lift fan exhaust suppression system to meet future VTOL aircraft noise goals was designed and tested. The test vehicle was a 1.3 pressure ratio, 36 inch (91.44 cm) diameter lift fan with two chord rotor to stator spacing. A two splitter fan exhaust suppression system thirty inches (76.2 cm) long achieved 10 PNdB exhaust suppression in the aft quadrant compared to a design value of 20 PNdB. It was found that a broadband noise floor limited the realizable suppression. An analytical investigation of broadband noise generated by flow over the treatment surfaces provided very good agreement with the measured suppression levels and noise floor sound power levels. A fan thrust decrement of 22% was measured for the fully suppressed configuration of which 11.1% was attributed to the exhaust suppression hardware.

Stimpert, D. L.↗

Assessment of jets as acoustic shields by comparison of single- and multitube suppressor nozzle data

Recent 1/4 scale and engine size nozzle acoustic data, for both 37-tube and single nozzles, were used to test the jet-shielding principle. At low jet velocities the multitube nozzle total sound power approaches the equivalent of 37 single tubes (no shielding), while near-sonic and above, the small equivalent number of single tubes compares well with a geometric model of lateral radiation from only about a third of the circumference of the outer jets (nearly complete shielding). At high jet velocities, the geometric shielding hypothesis is in excellent agreement with acoustic data from which the downstream coalesced jet noise is excluded. Present results are compared with an existing correlation for single jets, and with previous publications on multijet shielding.

Gray, V. H.↗

Developmental design, fabrication, and test of acoustic suppressors for fans of high bypass turbofan engines

An analysis procedure was developed for design of acoustically treated nacelles for high bypass turbofan engines. The plan was applied to the conceptual design of a nacelle for the quiet engine typical of a 707/DC-8 airplane installation. The resultant design was modified to a test nacelle design for the NASA Lewis quiet fan. The acoustic design goal was a 10 db reduction in effective perceived fan noise levels during takoff and approach. Detailed nacelle designs were subsequently developed for both the quiet engine and the quiet fan. The acoustic design goal for each nacelle was 15 db reductions in perceived fan noise levels from the inlet and fan duct. Acoustically treated nacelles were fabricated for the quiet engine and quiet fan for testing. Performance of selected inlet and fan duct lining configurations was experimentally evaluated in a flow duct. Results of the tests show that the linings perform as designed.

Tucker, R. H.↗

A forward speed effects study on jet noise from several suppressor nozzles in the NASA/Ames 40- by 80-foot wind tunnel

A test program was conducted in a 40 by 80 foot wind tunnel to evaluate the effect of relative velocity on the jet noise signature of a conical ejector, auxiliary inlet ejector, 32 spokes and 104 tube nozzle with and without an acoustically treated shroud. The freestream velocities in the wind tunnel were varied from 0 to 103.6 m/sec (300 ft/sec) for exhaust jet velocities of 259.1 m/sec (850 ft/sec) to 609.6 m/sec (2000 ft/sec). Reverberation corrections for the wind tunnel were developed and the procedure is explained. In conjunction with wind tunnel testing the nozzles were also evaluated on an outdoor test stand. The wind tunnel microphone arrays were duplicated during the outdoor testing. The data were then extrapolated for comparisons with data measured using a microphone array placed on a 30.5 meter (100 ft) arc. Using these data as a basis, farfield to nearfield arguments are presented with regards to the data measured in the wind tunnel. Finally, comparisons are presented between predictions made using existing methods and the measured data.

Beulke, M. R.↗