Search NASA⌕ Search

SEARCH · Search NASA

Results for “SUSPENSION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Development of superconductor magnetic suspension and balance prototype facility for studying the feasibility of applying this technique to large scale aerodynamic testing

The unique design and operational characteristics of a prototype magnetic suspension and balance facility which utilizes superconductor technology are described and discussed from the point of view of scalability to large sizes. The successful experimental demonstration of the feasibility of this new magnetic suspension concept of the University of Virginia, together with the success of the cryogenic wind-tunnel concept developed at Langley Research Center, appear to have finally opened the way to clean-tunnel, high-Re aerodynamic testing. Results of calculations corresponding to a two-step design extrapolation from the observed performance of the prototype magnetic suspension system to a system compatible with the projected cryogenic transonic research tunnel are presented to give an order-of-magnitude estimate of expected performance characteristics. Research areas where progress should lead to improved design and performance of large facilities are discussed.

Zapata, R. N.↗

Magnetic suspension system for a laboratory model annular momentum control device

Feasibility of the annular momentum control device (AMCD) for the control and stabilization of spacecraft is presented. The AMCD is momentum storage equipment consisting of a thin rim, magnetically suspended and rotated by noncontacting electromagnetic actuators. The laboratory model AMCD, the rim, and the magnetic suspension system are described, along with their evaluation tests. Because it utilizes permanent magnet flux biased magnetic bearing elements, the original laboratory model magnetic suspension system produced control limitations, and a new suspension system which used zero flux bias was designed and fabricated. Tests of the improved system show that a medium control loop bandwidth is required to achieve stability at low rim velocities, but at higher rim speed the bandwidth of the control loop interacts with bending modes of the rim and causes instability. Decreasing the bandwidth by changing to a precession control mode is discussed, and the results of such a computer simulation are presented.

Groom, N. J.↗

Differential capacitance sensor as position detector for a magnetic suspension densimeter

In the present work, which consists of adapting a magnetic suspension densimeter for use at pressures up to 350 bars, a differential capacitance sensor is developed for use in the servosystem of a magnetic suspension densimeter for detecting the position of a magnetic buoy. This type of sensor has not been used previously in magnetic suspension densimeters. Its design, performance, and advantages are outlined. A cutaway drawing and a schematic diagram of the capacitance sensor and magnetic buoy are presented and described. The concentric-disk design of the sensor capacitor plates and the high degree of symmetry which results from the printed circuit fabrication approach minimize the sensor sensitivity to lateral displacement of the buoy and to the dielectric constant of the surrounding medium. A high-power microscope is necessary to monitor the position of the buoy relative to the support coil.

Frederick, N. V.↗

Experimental feasibility study of the application of magnetic suspension techniques to large-scale aerodynamic test facilities

Based on the premises that magnetic suspension techniques can play a useful role in large scale aerodynamic testing, and that superconductor technology offers the only practical hope for building large scale magnetic suspensions, an all-superconductor 3-component magnetic suspension and balance facility was built as a prototype and tested sucessfully. Quantitative extrapolations of design and performance characteristics of this prototype system to larger systems compatible with existing and planned high Reynolds number facilities at Langley Research Center were made and show that this experimental technique should be particularly attractive when used in conjunction with large cryogenic wind tunnels.

Zapata, R. N.↗

Suspension restraint - Induced hypokinesia and antiorthostasis as a simulation of weightlessness

Muscle, renal, fluid and electrolyte responses were measured in suspended rats; the hind limbs are non-load bearing and the front limbs can be used for feeding and grooming. Hind limb hypokinesia reverses after removal from the suspension harness. This suspension system is adjustable for a head-down tilt to produce antiorthostatic responses which are also reversible. Responses to hypokinesia or antiorthostatic hypokinesia for up to 14 days were measured, e.g., muscle atrophy: soleus greater than gastrocnemius equals plantaris greater than extensor digitorum longus, kaliuresis, and increased excretion of urea, NH3, and 3 methylhistidine. Muscle protein loss, a response to a reduction in RNA, is also reversible. A head-down tilt for 7-14 days results in diuresis and natriuresis. These changes are reversed within 24 hours after removal from the restraint harness. Physiological effects of suspension restraint can be used to simulate and predict responses to microgravity exposure.

Musacchia, X. J.↗

Biochemical and histochemical adaptations of skeletal muscle to rat suspension

The influence of rat suspension on soleus disuse and atrophy was investigated to measure changes in fiber area and number and to determine if suspension elicited changes in lysosomal protease activity and rate of calcium uptake by the sarcoplasmic reticulum. The infuence of rat suspension on myosin light chain phosphorylation and succinate dehydrogenase activity are determined.

Templeton, G. H.↗

Extensions of suspension systems to measure effects of hypokinesia/hypodynamia and antiorthostasis in rats

Suspension systems are used to simulate hypokinetic/hypodynamic (H/H) and anitorthostatic (AO) responses seen under conditions of weightlessness. Growing rats in H/H suspension with unloaded hindlimbs for one and two weeks respond with muscle atrophy and increased excretion of nitrogenous end products such as urea, NH3 and 3 methyl histidine. Since muscle is in a dynamic state of synthesis and breakdown of protein, relationships between protein, RNA and DNA contents in the four muscles which reflect weight bearing and non-weight bearing functions were assessed. Protein and RNA progressively decreased over a one and two week period of H/H suspension: soleus gastrocnemius=plantaris EDL. Concommitant analysis of DNA contents showed there were no changes. The interpretation was that protein synthesis was slowed during H/H. As with muscle mass, protein and RNA levels recovered rapidly after removal from H/H. The AO rats (which are also H/H) respond with diuresis, natriuresis and kaliuresis in a manner comparable to responses seen when thoracic blood vessels are volume loaded.

Musacchia, X. J.↗

Theoretical study of the freezing of polystyrene sphere suspensions

A theoretical study of melting in aqueous suspensions of polystyrene spheres is presented. The Helmholtz free energies of the liquid and solid phase of the suspensions are calculated as functions of sphere number density and electrolyte concentrations. The results tend to show that the freezing curve of such suspensions is that of a conventional classical liquid with repulsive short-range interactions. The interactions can be treated satisfactorily within a slightly modified Debye-Hueckel approximation. The modifications include size correction and a correction for nonlinear screening. The results are confirmed by analogous calculations for the solid phase, and for the line along which liquid and solid free energies are equal.

Shih, W.-H.↗

Skeletal response to simulated weightlessness - A comparison of suspension techniques

Comparisons are made of the skeletal response of rats subjected to simulated weightlessness by back or tail suspension. In comparison to pair-fed control rats, back-suspended rats failed to gain weight whereas tail-suspended rats exhibited normal weight gain. Quantitative bone histomorphometry revealed marked skeletal abnormalities in the proximal tibial metaphysis of back-suspended rats. Loss of trabecular bone mass in these animals was due to a combination of depressed longitudinal bone growth, decreased bone formation, and increased bone resorption. In contrast, the proximal tibia of tail-suspended rats was relatively normal by these histologic criteria. However, a significant reduction trabecular bone volume occurred during 2 weeks of tail suspension, possibly due to a transient inhibition of bone formation. The findings indicate that tail suspension may be a more appropriate model for evaluating the effects of simulated weightlessness on skeletal homeostasis.

Wronski, T. J.↗

Physiological responses during whole body suspension of adult rats

The objective of this study was to characterize responses of adult rats to one and two weeks of whole body suspension. Body weights and food and water intakes were initially reduced during suspension, but, while intake of food and water returned to presuspension levels, body weight remained depressed. Diuresis was evident, but only during week two. Hindlimb muscle responses were differential, with the soleus exhibiting the greatest atrophy and the EDL a relative hypertrophy. These findings suggest that adult rats respond qualitatively in a manner similar to juveniles during suspension.

Steffen, J. M.↗

Effect of antiorthostatic suspension on interferon-alpha/beta production by the mouse (41939)

Mice were suspended in a model that simulates the weightlessness that occurs during prolonged space flight. After one and two weeks of suspension in an antiorthostatic (head-down tilt) position, the mice were challenged with polyriboinosinic-polyribocytidylic acid to induce interferon-alpha/beta. Interferon production was severely reduced in mice that had been suspended. When mice were allowed to recover in cages for a week following removal from suspension, they recovered their full interferon-production capacity. Mice suspended in an orthostatic (horizontal) position did not have their interferon production capabilities affected, which indicates that stress per se was not a major component in the effects of antiorthostatic suspension on interferon induction.

Rose, Andrea↗

Flux-Feedback Magnetic-Suspension Actuator

Flux-feedback magnetic-suspension actuator provides magnetic suspension and control forces having linear transfer characteristics between force command and force output over large range of gaps. Hall-effect devices used as sensors for electronic feedback circuit controlling currents flowing in electromagnetic windings to maintain flux linking suspended element at substantially constant value independent of changes in length of gap. Technique provides effective method for maintenance of constant flux density in gap and simpler than previous methods. Applications include magnetic actuators for control of shapes and figures of antennas and of precise segmented reflectors, magnetic suspensions in devices for storage of angular momentum and/or kinetic energy, and systems for control, pointing, and isolation of instruments.

Groom, Nelson J.↗

Stress in dilute suspensions

Generally, two types of theory are used to describe the field equations for suspensions. The so-called postulated equations are based on the kinetic theory of mixtures, which logically should give reasonable equations for solutions. The basis for the use of such theory for suspensions is tenuous, though it at least gives a logical path for mathematical arguments. It has the disadvantage that it leads to a system of equations which is underdetermined, in a sense that can be made precise. On the other hand, the so-called averaging theory starts with a determined system, but the very process of averaging renders the resulting system underdetermined. A third type of theory is proposed in which the kinetic theory of gases is used to motivate continuum equations for the suspended particles. This entails an interpretation of the stress in the particles that is different from the usual one. Classical theory is used to describe the motion of the suspending medium. The result is a determined system for a dilute suspension. Extension of the theory to more concentrated systems is discussed.

Passman, Stephen L.↗

Scaling and modeling of turbulent suspension flows

Scaling factors determining various aspects of particle-fluid interactions and the development of physical models to predict gas-solid turbulent suspension flow fields are discussed based on two-fluid, continua formulation. The modes of particle-fluid interactions are discussed based on the length and time scale ratio, which depends on the properties of the particles and the characteristics of the flow turbulence. For particle size smaller than or comparable with the Kolmogorov length scale and concentration low enough for neglecting direct particle-particle interaction, scaling rules can be established in various parameter ranges. The various particle-fluid interactions give rise to additional mechanisms which affect the fluid mechanics of the conveying gas phase. These extra mechanisms are incorporated into a turbulence modeling method based on the scaling rules. A multiple-scale two-phase turbulence model is developed, which gives reasonable predictions for dilute suspension flow. Much work still needs to be done to account for the poly-dispersed effects and the extension to dense suspension flows.

Chen, C. P.↗

Effect of hindlimb suspension on cardiovascular responses to sympathomimetics and lower body negative pressure

To determine whether hindlimb suspension is associated with the development of cardiovascular deconditioning, male rats were studied before and after undergoing one of three treatment conditions for 9 days: (1) cage control (n = 15, CON), (2) horizontal suspension (n = 15, HOZ), and (3) head-down suspension (n = 18, HDS). Testing included lower body negative pressure administered during chloralose-urethan anesthesia and graded doses of sympathomimetic agents (norepinephrine, phenylephrine, and tyramine) administered to conscious unrestrained animals. Both HDS and HOZ were associated with a small decrease in the hypotensive response to lower body negative pressure. The HOZ group, but not the HDS group, exhibited augmented reflex tachycardia. Furthermore, both HDS and HOZ groups manifested reduced pressor responses to phenylephrine after treatment. These reductions were associated with significantly attenuated increases in mesenteric vascular resistance. However, baroreflex control of heart rate was not altered by the treatment conditions. Collectively, these results indicate that 9 days of HDS in rats does not elicit hemodynamic response patterns generally associated with cardiovascular deconditioning induced by hypogravic conditions.

Overton, J. Michael↗

Age effects on rat hindlimb muscle atrophy during suspension unloading

The effects of hindlimb unloading on muscle mass and biochemical responses were examined and compared in adult (450-g) and juvenile (200-g) rats after 1, 7, or 14 days of whole-body suspension. Quantitatively and qualitatively the soleus, gastrocnemius, plantaris, and extensor digitorum longus (EDL) muscles of the hindlimb exhibited a differential sensitivity to suspension and weightlessness unloading in both adults and juveniles. The red slow-twitch soleus exhibited the most pronounced atrophy under both conditions, with juvenile responses being greater than adult. In contrast, the fast-twitch EDL hypertrophied during suspension and atrophied during weightlessness, with no significant difference between adults and juveniles. Determination of biochemical parameters (total protein, RNA, and DNA) indicates a less rapid rate of response in adult muscles.

Steffen, Joseph M.↗

Aerospace Applications of Magnetic Suspension Technology, part 1

Papers presented at the conference on aerospace applications of magnetic suspension technology are compiled. The following subject areas are covered: pointing and isolation systems; microgravity and vibration isolation; bearing applications; wind tunnel model suspension systems; large gap magnetic suspension systems; control systems; rotating machinery; science and application of superconductivity; and sensors.

Groom, Nelson J.↗

Magnetic suspension systems for space applications

An overview of techniques is presented used in the described magnetic suspension systems. Also a review is presented of the systems already developed, which demonstrate the usefulness, applicability, and flight readiness of magnetic suspension to a broad range of payloads and environments. The following subject areas are covered: programs overview; key concepts; magnetic suspension as an isolator and as a pointer; pointing and isolation systems; magnetic actuator control techniques; and test data.

Havenhill, Douglas G.↗