Effect and measurement of residual water in CaCl 2 intended for use as electrolyte in molten salt electrochemical processing

We report CaCl 2 has applications for electrochemical processing of nuclear materials. Thermal dehydration leads to formation of oxide ions, which are shown to react and cause precipitation of dissolved CeCl 3 that was selected as a surrogate for actinide chlorides. Thus, measurement of residual water in CaCl 2 is an essential capability. Thermogravimetric analysis (TGA) was shown to underestimate starting water concentration. Subsequent analysis of solid samples via acid–base titration and cyclic voltammetry (CV) of the molten salt yielded consistent values within 5% for residual water. Hydroxides were shown to be unstable, thus oxygen is retained as oxide ions. Thus, total water in a sample of CaCl 2 can be quantified by combining TGA with with either CV of molten salt or titration of salt samples. The importance of quantifying residual water in the salt was demonstrated by showing that cerium chloride (surrogate for actinide chlorides) will react with oxide ions in CaCl 2 to form insoluble oxides and oxychlorides.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Actinide Removal Process October 2014 Sample Analysis

Filtration within the Actinide Removal Process (ARP) currently limits the throughput in interim salt processing at the Savannah River Site. In this process, batches of salt solution with Monosodium Titanate (MST) sorbent are concentrated by crossflow filtration. The filtrate is subsequently processed to remove cesium in the Modular Caustic Side Solvent Extraction Unit (MCU) followed by disposal in saltstone grout. The concentrated MST slurry is washed and sent to the Defense Waste Processing Facility (DWPF) for vitrification. During past ARP processing, there has been a degradation of filter performance manifested as the inability to maintain high filtrate flux throughout a multi-batch cycles during Salt Batches 6, 5 and 4. The objectives of the current effort for Salt Batch 7 samples, which are similar to the most recent ARP sample analysis from 2013, were to characterize the feed streams, to determine if solids (in addition to MST) are precipitating and causing the degraded performance of the filters, and to assess the particle size and rheological data to address potential filtration impacts. The samples from the LWPT and LWHT were obtained from several stages of processing of Salt Batch 7B, Cycle 1, Batch 67.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

V5 and V10 Contactor Testing with the Next Generation (CSSX) Solvent for the Savannah River Site Integrated Salt Disposition Process

A solvent extraction system for removal of cesium (Cs) from alkaline solutions was developed utilizing a novel solvent invented at the Oak Ridge National Laboratory (ORNL). This solvent consists of a calix[4]arene-crown-6 extractant dissolved in an inert hydrocarbon matrix. A Modifier is added to the solvent to enhance the extraction power of the calixarene and to prevent the formation of a third phase. An additional additive, called a suppressor, is used to improve stripping performance. The process that deploys this solvent system is known as Caustic Side Solvent Extraction (CSSX). The solvent system has been deployed at the Savannah River Site (SRS) in the Modular CSSX Unit (MCU) since 2008.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Extraction, Scrub, and Strip Test Results for the Salt Waste Processing Facility Sample Tank 202

An Extraction, Scrub, and Strip (ESS) test was performed on a sample from Tank-202. The purpose of testing this sample is to determine if the solvent is displaying the correct extraction and stripping behavior with cesium. The ESS test showed acceptable performance of the solvent for extraction, scrub, and strip operations. The extraction D(Cs) measured 14.2, exceeding the required value of 8. This value is consistent with results from previous ESS tests using similar solvent formulations. Similarly, the strip cesium distribution ratios fell within acceptable ranges.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Investigation of potential causes of production limiting fouling within SWPF due to mercury solids formation during pH swings within the SWPF process

The Salt Waste Processing Facility (SWPF) goal to investigate the use a high sodium Salt Batch 5 Qualification sample as the radioactive salt solution for mixing tests meant to evaluate the propensity for solids formation between the 5.6 M sodium clarified salt solution (CSS) and scrub solutions (0.05 M HNO 3 and 0.025 M NaOH solutions) during pH changes has been completed at SRNL. The key results and conclusions from this investigation to evaluate the propensity for solids formation between CSS and scrub solutions because of pH fluctuations include the following: None of the 8 test matrices, involving the mixing/titrating of scrub solution with CSS and vice versa, showed any visible evidence for the formation of solids with pH changes. The average turbidity measurements for these 8 tests, excluding test 7, was 21.6 ± 0.4 NTU. This average turbidity value is within 2 sigma of the baseline turbidity value of 20.5 NTU for the CSS only without added scrub solutions. However, only in test 7, which involved the titrating of CSS into dilute nitric acid scrub solution (0.05 M HNO 3 solution), was a small measurable change in the turbidity of the mixture observed at 31.9 ºC. On the other hand, the equivalent test (instantaneous addition of CSS into 0.05 M HNO 3 ) gave an average turbidity measurement value of 21.6 ± 0.6 NTU at a temperature of 24.0 ºC. This difference in turbidity measurement has been attributed to either instrument performance errors or the effect of temperature. It is recommended that these CSS and scrub solution mixing tests be performed with corresponding simulant solutions in a non-radioactive environment. A simulant environment will aid in the full integration of a pH and turbidity meter equipment with the experimental set up. A new detection method, preferable a laser-based method, may be needed in detecting and confirming the precipitation of fine particulates at the right blending times and pH fluctuations in the solution mixtures. On the other hand, the differing free OH concentrations (~2 M in CSS), H + concentrations (0.05 M HNO 3 ) for the titrants and the bulk solutions, may make it almost impossible to observe a neutral pH or a pH in the range of 7-9, where the potential for solids formation is maximized and leads to possible precipitation of minerals like aluminum hydroxides.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Installation and Commissioning of the Netzsch Skimmer

The DOE molten salt reactor (MSR) program has been focusing on the thermochemistry and transport properties of fuel, diluent/carrier, coolant, flush, and reprocessing salts proposed for various molten salt reactor technologies. Data from the chemistry project inform models of salt behavior used in dynamic models of nuclear salt reactors, for both high fidelity and systems simulations. Reactor and salt processing systems operate well above salt melting points (>600°C), so salt behavior can be well described by thermodynamics. However, much is not known about salt systems that contain two, three, or even more components. The Netzsch skimmer (commissioned this year) can be used in several configurations to collect data on molten systems. The skimmer uses mass spectrometry coupled with a thermogravimetric analyzer to accurately analyze systems up to 2000°C. Because the mass analyzer is coupled directly to the furnace through two nested orifices, there are no losses due to condensation. As a thermogravimetric analyzer, the skimmer measures weight loss and reaction energies simultaneously with evolved gas analysis. The mass spectrometry identifies gas phase species, and these volatility measurements can be used to derive vapor pressures. The skimmer was purchased in fiscal year 2018, delivered in April, installed in May 2019, and now is fully operational as verified by the analysis of known standards. The skimmer is unique because it will be available for study of salt systems that contain actinides or beryllium, although the additional work control to accommodate these hazards is still under review.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Testing of a Microfluidic Sampling System for High Temperature Electrochemical MC&A

This report describes the preliminary validation of a high-temperature microfluidic chip system for sampling of electrochemical process salt. Electroanalytical and spectroscopic techniques are attractive candidates for improvement through high-throughput sample analysis via miniaturization. Further, microfluidic chip systems are amenable to micro-scale chemical processing such as rapid, automated sample purification to improve sensor performance. The microfluidic chip was tested to determine the feasibility of the system for high temperature applications and conditions under which microfluidic systems can be used to generate salt droplets at process temperature to support development of material balance and control systems in a used fuel treatment facility. In FY13, the project focused on testing a quartz microchip device with molten salts at near process temperatures. The equipment was installed in glove box and tested up to 400°C using commercial thermal transfer fluids as the carrier phase. Preliminary tests were carried out with a low-melting halide salt to initially characterize the properties of this novel liquid-liquid system and to investigate the operating regimes for inducing droplet flow within candidate carrier fluids. Initial results show that the concept is viable for high temperature sampling but further development is required to optimize the system to operate with process relevant molten salts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optimization of Saltcake Removal Flowsheet at SRS through Incorporation of Testing and In-Tank Waste Experience

Saltcake removal at SRS may be performed for several reasons: to provide space for evaporator operation (i.e., to precipitate more salt in the drop tank), to provide feed for salt processing (i.e. immobilize the waste), or to remove the salt for tank closure. Many different salt dissolution techniques have been employed in the 40 years that SRS has been performing salt removal, from a basic “Add, Sit, Remove” method (water is added on top of the saltcake and time is allowed for diffusion), to performing interstitial liquid removal, or using mixing devices to promote contact with the liquid. Lessons learned from previous saltcake removal campaigns, in addition to testing and modeling, have led to opportunities for improvements to the overall saltcake removal process. This includes better understanding of salt properties and behavior during dissolution; the primary concerns for salt dissolution are the release of radiolytic hydrogen and criticality prevention (post-dissolution). Recent developments in salt dissolution include the reuse of dilute supernate and a semi-continuous dissolution (SCD) process, where low volume mixing eductors are used to deliver water near the surface of the saltcake at the same rate as the salt solution is removed and transferred to a receipt tank.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Electrolytic recovery of metals from lithium battery cathodes in moisture-tolerant molten hydroxide salt

Lithium-ion battery recycling offers an opportunity to develop innovative technologies to close the loop on the battery materials cycle and increase the resilience of the battery supply chain. Here, in this study, we demonstrate a two-step pyroelectrochemical method for producing mixed-metals from lithium-ion cathodes in a molten hydroxide salt. Mixed metal oxides in the form of insoluble lithium-ion cathode materials of LiNi 0.6 Mn 0.2 Co 0.2 O 2 (NMC622) and spent lithium-ion battery materials (black mass) were electrochemically reduced to a soluble form and dissolved into a molten hydroxide salt bath. Electrochemical characterization of the process salt indicated accumulation of dissolved transition metals in the salt. A separate cathode was used to produce alloys of Ni, Mn, and Co electrochemically from the dissolved lithium-ion cathode materials. Characterization by scanning electron microscopy fitted with an energy dispersive X-ray spectrometer showed transition metals present in the cathode materials were recovered at the separate cathode. This approach represents a scalable, low temperature pyroelectrochemical process that can potentially reduce the cost and close the loop of battery cathode recycling.

25 ENERGY STORAGE↗

Salt Sampling FY21 Technical Report

The goal of the salt sampling program at Argonne is to develop and deploy automated molten salt sampling approaches to enable high-precision in-process salt sample analysis to improve the timeliness of sampling-based accountancy measurements. Tools currently under development in support of this goal include (1) a modular vacuum sampler with an accompanying sample handling method for coupling vacuum sampling with high-precision at-line sample analysis, (2) a pneumatic sample generator that enables high-throughput sample analysis to improve the precision of existing analytical techniques, and (3) a windowless flow cell to enable on-line optical analysis of molten salt in a sampling loop. Compared to point sampling approaches (i.e., dip probes), vacuum sampling systems and on-line sampling loops facilitate access to a larger cross-section of a process fluid. This is known to improve the characterization of the process fluid by producing more representative samples and by enabling the analysis of a larger cross section of the fluid. A vacuum sampling approach for molten salts eliminates the risk of dross contamination of samples and avoids the use of moving parts in the salt. In FY21, two methods for integrating a vacuum sampler with a pneumatic sample generator were tested. These included direct fluidic coupling and coupling using a solid salt transfer mechanism. Solid salt transfer was ultimately selected over fluidic coupling, primarily to enable the transport of samples over longer distances to support automated at-line integration with high-precision techniques (such as microcalorimetry) that cannot withstand the extreme conditions near an electrorefining process. To facilitate rapid solid salt coupling, new mechanisms were developed for rapidly charging and discharging salt sample tubes at the vacuum sampler and pneumatic sample generator, respectively. While the charging mechanism will be deployed in FY22, the tube transfer method and discharge mechanism were tested in FY21. These were deployed at one of Argonne’s engineering-scale electrorefiners to implement at-line high-throughput pneumatic micro-sample generation capabilities. The method was used to generate precise uranium- and lanthanide-bearing electrorefiner micro-samples with the specific dimensions requested by researchers at Los Alamos National Laboratory for use in testing their novel microcalorimeter x-ray techniques. The solid salt transfer mechanism proved not only to be an effective means of integrating the precision sample generator with vacuum sampling, but also improved the performance of the sampler generator. Because the modular sampling approach described here eliminates the need for new high-radiation sample handling capabilities, salt-wetted seals, salt-wetted moving parts, and heated transfer lines outside the electrorefiner, it will address most of the remaining technical challenges for the at-line deployment of high-precision analytical techniques. This will enable significant reductions in the time delay for sampling-based accountancy measurements by eliminating the need for manual off-line sample processing and analysis. On-line optical analysis of molten salt in a sampling loop would provide complementary information to at-line and in-situ techniques. In FY21, an open-aperture molten salt gravity flow cell with windowless optical access to flowing salt was successfully demonstrated. Future work should include the refinement and performance testing of the on-line and at-line sampling tools, integration of additional analysis techniques, stakeholder outreach and collaboration, evaluation of the integrated methods, and analyses to determine how the various tools might fit into an integrated safeguards monitoring system of unattended near real time monitoring tools.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Safeguards Challenges for Molten Salt Reactors

There are now a wide variety of molten salt reactor (MSR) technologies being proposed or developed that are gaining international interest and momentum toward deployment. There are two sub-categories of this class of reactors - those that are liquid fueled (i.e., the molten salt is both the fuel and the coolant) and those that have solid fuel with the molten salt used as coolant only. The liquid-fueled MSRs present unique challenges to current safeguards approaches. These challenges exist because there are currently no conceptual approaches to applying safeguards to unique, tightly coupled nuclear energy systems with the reactor core, balance of plant, and fuel cycle (everything else including salt processing and material separations) combined in a single facility. The application of safeguards to liquid-fueled MSRs will have to take into consideration several technical factors including: The homogeneous mixture of fuel, coolant, fission products, and actinides (with the attendant extremely high radiation field); Continuous variation in isotopic concentrations in the fuel salt, including removal (passive or active) of fission products, rare earth elements, and noble metals; High operating temperatures of the fuel salt; Online processing where some fraction of the inventory can be removed while the reactor is operational; Unique refueling schemes, including the ability to continuously feed the core with fresh fissile or fertile material; The presence of frozen fuel, potentially requiring a different safeguards process from the liquid fuel; and The presence of fuel outside the vessel. Additionally, If the thorium fuel cycle is employed, there will be additional complications since the resulting radiation signatures will be different from those of the uranium-based fuel cycle. The existing IAEA inspection regimes are based on the uranium-plutonium fuel cycle, item counting for nuclear reactors, and bulk material accountancy for the front and back end of the nuclear fuel cycle. These techniques and associated instrumentation for bulk accountancy have been developed predominantly for enrichment, fuel fabrication, and aqueous reprocessing. However, none of these bulk accountancy measures can be directly applied to liquid-fueled MSRs. This paper will explore some of the possible challenges in applying safeguards to molten salt reactors.