Search NASA⌕ Search

SEARCH · Search NASA

Results for “Salt freezing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

INL_Intern_Poster_ColeBailey [Poster]

Understanding the thermophysical properties of molten salts is crucial for the advancement of nuclear fuels. This project presents the design of a custom differential thermal analyzer (DTA) that utilizes non-contact ultrasonic mixing to agitate samples and prevent supercooling. The supercooling effect occurs when a liquid is below its freezing point without solidifying. This can be observed when a liquid in a freezer instantly transitions to its solid phase upon disturbance. By avoiding this effect, accurate transition temperatures of molten salts can be gathered for future applications. Initial mixing results were promising, leading to further refinement of the waveguides using ABAQUS to maximize input energy into the fluid. Future work will focus on integrating both mixing and cooling in conjunctions to observe the avoided effect.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Explainable machine learning for incipient anomaly detection in compact molten salt heat exchanger with overlapping feature distributions

High-temperature molten salt-cooled reactors (MSCRs) are a promising next-generation nuclear technology option, offering efficient power conversion and inherent safety features. However, the reliability of these systems depends on the robust operation of heat exchangers (HXs), which are susceptible to failure due to temperature gradients and channel plugging caused by fluid freezing. Conventional monitoring methods, relying on inlet and outlet measurements, lack the spatial resolution needed to detect early-stage faults. We propose a novel design of a compact salt-to-salt matrix-type HX design consisting of interleaved arrays of parallel tubes, with integrated synthetic fiber optic distributed temperature sensing (DTS) to enable localized detection of incipient faults. To evaluate performance of this design, we generate high-fidelity synthetic data using heat transfer computational modeling to simulate channel plugging, and introduce sensor noise for realistic modeling of measurements. The dataset comprises of 97% normal operation and 3% anomaly cases, with each anomaly class representing 1% of the data. These early anomalies result in overlapping temperature profiles between normal and faulty channels, producing a non-separable dataset that challenges traditional classification techniques. We benchmark eight supervised machine learning (ML) models and demonstrate that XGBoost achieves the highest performance. To improve transparency, we develop an explainability framework combining Shapley values and partially ordered sets (POSETs) to quantify and structurally analyze feature importance. This approach identifies both dominant predictors and ambiguous feature relationships, enhancing trust and interpretability. Our results highlight the potential of combining DTS and explainable ML with intelligent feature selection to improve predictive maintenance and ensure operational resilience in advanced nuclear systems.

Prantikos, Konstantinos [Argonne National Laborato↗

High Power Density Thermal Energy Storage With Phase Change Material in Enhanced Compact Heat Exchangers

Abstract Performance of a novel ultracompact thermal energy storage (TES) heat exchanger, designed as a microchannel finned-tube exchanger is presented. With water as the heating–cooling fluid in the microchannels, a salt hydrate phase change material (PCM), lithium nitrate trihydrate (LiNO3 · 3H2O), was encased on the fin side. To establish the hypothesis that small-length-scale encasement (<3 mm) of PCM substantially enhances heat transfer to yield very high power-density energy storage, heat exchanger designs with 10 and 24 fins/inch were considered. They were subjected to thermal cycling, or repeated heating (melting) and cooling (freezing), with inlet fluid flow mimicking diurnal variation between 42 °C and 25 °C (representing typical arid-region conditions) over an accelerated time period. By employing salt self-seeding to obviate subcooling during cooling or recrystallization, the TES was found to exhibit stable long-term (100 heating–cooling cycles) operation with very high PCM-side heat transfer coefficients (∼100–500 W/m2 K) and storage power density (∼160–175 kW/m3). In fact, with optimization of heating–cooling fluid flowrate for given charging–discharging time period and exchanger size, power density >300 kW/m3 can be achieved. The results clearly establish that highly compact heat exchangers used as TES units can provide very high-performance alternatives to conventional ones.

Engineering↗

Development and Demonstration of a Prototype Molten Salt Sampling System

Molten salt reactors (MSRs) offer potential operability and safety advantages when compared to commercial light water reactors (LWRs). However, operating experience with MSRs is sparse in comparison to what exists for LWRs. Further, the chemical and isotopic composition of the fuel and/or coolant salt is dynamic and difficult to characterize continuously, posing potential safety, operability, and safeguards unknowns that need to be addressed. A molten salt sampling system (MSSS) is regarded as a necessary subsystem within first generation MSRs used to obtain samples of salt for chemical and isotopic analysis in support of the need to monitor and control salt composition during operation. The MSSS is being developed using the Safety-in-Design (SiD) methodology, which incorporates incremental integration of safety analysis into the design process. The MSSS conceptual design emerging from the application of the early stages of the SiD methodology consists of a sample collection system and its housing, a freeze port, and inert gas control and delivery systems. This article describes the prototypes developed to test the functions of these MSSS subsystems, presents the results of testing in both dry and molten salt environments (including reliability data collection performed in accordance with the principles of SiD and the development of a semiquantitative fault tree model), and summarizes the opportunities for future design and testing enhancements based on the results of prototype testing.

molten salt reactor↗

Influence of Carboxymethyl Cellulose as a Thickening Agent for Glauber’s Salt-Based Low Temperature PCM

This work is focused on a novel, promising low temperature phase change material (PCM), based on the eutectic Glauber’s salt composition. To allow phase transition within the refrigeration range of temperatures of +5 °C to +12 °C, combined with a high repeatability of melting–freezing processes, and minimized subcooling, the application of three variants of sodium carboxymethyl cellulose (Na-CMC) with distinct molecular weights (700,000, 250,000, and 90,000) is considered. The primary objective is to optimize the stabilization of this eutectic PCM formulation, while maintaining the desired enthalpy level. Preparation methods are refined to ensure repeatability in mixing components, thereby optimizing performance and stability. Additionally, the influence of Na-CMC molecular weight on stabilization is examined through differential scanning calorimetry (DSC), T-history, and rheology tests. The PCM formulation of interest builds upon prior research in which borax, ammonium chloride, and potassium chloride were used as additives to sodium sulfate decahydrate (Glauber’s salt), prioritizing environmentally responsible materials. The results reveal that CMC with molecular weights of 250 kg/mol and 90 kg/mol effectively stabilize the PCM without phase separation issues, slowing crystallization kinetics. Conversely, CMC of 700 kg/mol proved ineffective due to the disruption of gel formation at its low gel point, hindering higher concentrations. Calculations of ionic concentration indicate higher Na ion content in PCM stabilized with 90 kg/mol CMC, suggesting increased ionic interactions and gel strength. A tradeoff is discovered between the faster crystallization in lower molecular weight CMC and the higher concentration required, which increases the amount of inert material that does not participate in the phase transition. After thermal cycling, the best formulation had a latent heat of 130 J/g with no supercooling, demonstrating excellent performance. This work advances PCM’s reliability as a thermal energy storage solution for diverse applications and highlights the complex relationship between Na-CMC molecular weight and PCM stabilization.

25 ENERGY STORAGE↗

Measuring Temperature Reading

There are two requirements for taking a measurement of something. The first is a tool for taking a measurement. The second is scale for making sense of the numbers of the measurement. For example, a ruler is often used to measure short lengths. It is the tool for measurement. On the ruler are one or more number scales with equally spaced numbers. These numbers can be compared with numbers from any other ruler that is accurately set to the same scale. Measuring length is far simpler than measuring temperature. While there is evidence of tools for measuring length at various times in human history, tools and scales for measuring temperature do not appear until more recent human history. Early thermometers, called thermoscopes, first appear in the 1500's. They were crude instruments that were not at all accurate. Most did not even have a number scale associated with them. This made them useless for most practical purposes. Gabriel Fahrenheit created the first accurate thermometer in 1714, and the Fahrenheit temperature scale followed it in 1724. The thermometer s accuracy was based on its use of mercury, a silver colored substance that remains liquid over a wide range of temperatures but expands or contracts in a standard, predictable way with changes in temperature. To set the scale, Fahrenheit created the coldest temperature that he could. He mixed equal parts of ice, water, and salt, and then used this as the zero point, 0 degrees, of his scale. He intended to make 30 degrees the freezing point of water and 90 degrees the temperature of the human body, but he had to later revise these temperatures to be 32 degrees and 96 degrees. In the final version of the scale, the temperature of the human body became 98.6 degrees. 19th century thermoscope

Source record↗

Characterization of Individual Aerosol Particles Associated with Clouds (CRYSTAL-FACE)

The aim of our research was to obtain data on the chemical and physical properties of individual aerosol particles from near the bottoms and tops of the deep convective systems that lead to the generation of tropical cirrus clouds and to provide insights into the particles that serve as CCN or IN. We used analytical transmission electron microscopy (ATEM), including energy-dispersive X-ray spectrometry (EDS) and electron energy-loss spectroscopy (EELS), and field-emission electron microscopy (FESEM) to compare the compositions, concentrations, size distributions, shapes, surface coatings, and degrees of aggregation of individual particles from cloud bases and the anvils near the tropopause. Aggregates of sea salt and mineral dust, ammonium sulfate, and soot particles are abundant in in-cloud samples. Cirrus samples contain many H2SO4 droplets, but acidic sulfate particles are rare at the cloud bases. H2SO4 probably formed at higher altitudes through oxidation of SO2 in cloud droplets. The relatively high extent of ammoniation in the upper troposphere in-cloud samples appears to have resulted from vertical transport by strong convection. The morphology of H2SO4 droplets indicates that they had been at least yartiy ammoniated at the time of collection. They are internally mixed with organic materials, metal sulfates, and solid particles of various compositions. Ammoniation and internal mixing of result in freezing at higher temperature than in pure H2SO4 aerosols. K- and S-bearing organic particles and Si-Al-rich particles are common throughout. Sea salt and mineral dust were incorporated into the convective systems from the cloud bases and worked as ice nuclei while being vertically transported. The nonsulfate particles originated from the lower troposphere and were transported to the upper troposphere and lower stratosphere.

Buseck, Peter R.↗

Coupling of Adhesion and Anti-Freezing Properties in Hydrogel Electrolytes for Low-Temperature Aqueous-Based Hybrid Capacitors

Solid-state zinc-ion capacitors are emerging as promising candidates for large-scale energy storage owing to improved safety, mechanical and thermal stability and easy-to-direct stacking. Hydrogel electrolytes are appealing solid-state electrolytes because of eco-friendliness, high conductivity and intrinsic flexibility. However, the electrolyte/electrode interfacial contact and anti-freezing properties of current hydrogel electrolytes are still challenging for practical applications of zinc-ion capacitors. Here, we report a class of hydrogel electrolytes that couple high interfacial adhesion and anti-freezing performance. The synergy of tough hydrogel matrix and chemical anchorage enables a well-adhered interface between hydrogel electrolyte and electrode. Meanwhile, the cooperative solvation of ZnCl 2 and LiCl hybrid salts renders the hydrogel electrolyte high ionic conductivity and mechanical elasticity simultaneously at low temperatures. More significantly, the Zn||carbon nanotubes hybrid capacitor based on this hydrogel electrolyte exhibits low-temperature capacitive performance, delivering high-energy density of 39 Wh kg –1 at –60 °C with capacity retention of 98.7% over 10,000 cycles. With the benefits of the well-adhered electrolyte/electrode interface and the anti-freezing hydrogel electrolyte, the Zn/Li hybrid capacitor is able to accommodate dynamic deformations and function well under 1000 tension cycles even at –60 °C. This work provides a powerful strategy for enabling stable operation of low-temperature zinc-ion capacitors.

25 ENERGY STORAGE↗

Monitoring of Liquid Metal Reactor Heater Zones with Recurrent Neural Network Learning of Temperature Time Series

Advanced high-temperature fluid reactors (ARs), such as sodium fast reactors (SFRs) and molten salt cooled reactors (MSCRs) utilize high-temperature fluids at ambient pressure. To melt the fluid during reactor startup and prevent fluid freezing during cooldown, the thermal–hydraulic systems of such ARs include heater zones consisting of specific heaters with controllers, temperature sensors, and thermal insulation. The failure of heater zones due to insulation material degradation or improper installation, resulting in parasitic heat losses, can lead to fluid freezing. The detection of faults using a heat-transfer model is difficult because of a lack of knowledge of the experimental details. Data-driven machine learning of heater zone temperature time series offers a viable alternative. In this study, we benchmarked the performance of recurrent neural networks (RNNs) in an analysis of heat-up transient temperature time series of heater zones installed on a liquid sodium vessel. The RNN models include long short-term memory (LSTM) and gated recurrent unit (GRU) networks, as well as their bi-directional variants, BiLSTM and BiGRU. Anomalous temperature points were designated using a percentile-based threshold applied to residual fluctuations in the detrended temperature time series. Additionally, the impact of the exponentially weighted moving average (EWMA) method on detection accuracy was examined. The RNN models’ performance was assessed using precision, recall, and F 1 score metrics. Results demonstrated that RNN models effectively detect anomalies in temperature time series with the best models for each heater zone achieving F 1 scores of over 93%. To explain the variations in RNN model performance across different heater zones, we used Kullback–Leibler (KL) divergence to quantify the relative entropy between training and testing data, and the Detrended Fluctuation Analysis (DFA) to assess long-range temporal correlations. For datasets with strong long-range correlations and minimal relative entropy between training and testing data, GRU is the best-performing model. When the data exhibits weaker long-term correlations and a significant relative entropy between training and testing distributions, BiGRU shows the best performance. For the data sets with intermediate values of both KL divergence and DFA, the best performance is obtained with LSTM and BiLSTM, respectively.

gated recurrent unit↗

Thermal energy storage flight experiments

Consideration is given to the development of an experimental program to study heat transfer, energy storage, fluid movement, and void location under microgravity. Plans for experimental flight packages containing Thermal Energy Storage (TES) material applicable for advanced solar heat receivers are discussed. Candidate materials for TES include fluoride salts, salt eutectics, silicides, and metals. The development of a three-dimensional computer program to describe TES material behavior undergoing melting and freezing under microgravity is also discussed. The TES experiment concept and plans for ground and flight tests are outlined.

Namkoong, D.↗

Physicochemical characterization of free troposphere and marine boundary layer ice-nucleating particles collected by aircraft in the eastern North Atlantic

Abstract. Atmospheric ice nucleation impacts the hydrological cycle and climate by modifying the radiative properties of clouds. To improve our predictive understanding of ice formation, ambient ice-nucleating particles (INPs) need to be collected and characterized. Measurements of INPs at lower latitudes in a remote marine region are scarce. The Aerosol and Cloud Experiments in the Eastern North Atlantic (ACE-ENA) campaign, in the region of the Azores islands, provided the opportunity to collect particles in the marine boundary layer (MBL) and free troposphere (FT) by aircraft during the campaign's summer and winter intensive operation period. The particle population in samples collected was examined by scanning transmission X-ray microscopy with near-edge X-ray absorption fine structure spectroscopy. The identified INPs were analyzed by scanning electron microscopy with energy-dispersive X-ray analysis. We observed differences in the particle population characteristics in terms of particle diversity, mixing state, and organic volume fraction between seasons, mostly due to dry intrusion events during winter, as well as between the sampling locations of the MBL and FT. These differences are also reflected in the temperature and humidity conditions under which water uptake, immersion freezing (IMF), and deposition ice nucleation (DIN) proceed. Identified INPs reflect typical particle types within the particle population on the samples and include sea salt, sea salt with sulfates, and mineral dust, all associated with organic matter, as well as carbonaceous particles. IMF and DIN kinetics are analyzed with respect to heterogeneous ice nucleation rate coefficients, Jhet, and ice nucleation active site density, ns, as a function of the water criterion Δaw. DIN is also analyzed in terms of contact angles following classical nucleation theory. Derived MBL IMF kinetics agree with previous ACE-ENA ground-site INP measurements. FT particle samples show greater ice nucleation propensity compared to MBL particle samples. This study emphasizes that the types of INPs can vary seasonally and with altitude depending on sampling location, thereby showing different ice nucleation propensities, which is crucial information when representing mixed-phase cloud and cirrus cloud microphysics in models.

54 ENVIRONMENTAL SCIENCES↗

Organic-rich fluids in Pluto’s interior—A source of cryovolcanic activity

The highly variegated surface of Pluto revealed by the New Horizons spacecraft is composed of both volatile ices (N2, CH4, CO) and H2O ice, all of which are intrinsically colorless. The colors on Pluto reveal a non-ice component generally acknowledged to be a refractory complex organic material (tholins) produced by photolysis in the planet’s atmosphere [1], and by photolysis and radiolysis of the surface ices [2-4]. These processes have produced a range of colors from pale yellow to red to brown, and result in a variation of a factor of 10in albedo across the surface. Tholins are disordered polymer-like materials made of repeating chains of linked subunits and complex combinations of functional groups containing carbon. Nitrogen, oxygen, and other elements can be substituted in both the aliphatic and aromatic subunits. The detection of the spectral absorption of an ammoniated compound associated with surface exposures of red-colored H2O ice (herein, RAW) in the LEISA spectral mapping data from New Horizons suggests that a third source of a colored material is ejected from Pluto’s interior as a water-rich fluid(cryomagma) that rapidly freezes at the low temperature (~40K) of the surface [5,6]. The ammoniated compound is thought to be an ammonia hydrate or an ammoniated salt; the spectral data cover a limited wavelength range, resulting in ambiguity in the identification of the form of the ammonia. The distribution of RAW in the vicinity of tectonically stressed and deformed geological structures, particularly graben (fossae), is seen as the result of both fluid effusion and fountaining ejection of cryoclastic materials in Pluto’s Virgil Fossae region [5,6]. RAW is seen elsewhere on Pluto, both in association with graben complexes and on broad expanses of old surface, but primarily in zones of tectonic stress. The nature of the putative subsurface fluid is unknown, but it must have existed at relatively shallow depths such that the graben faulting could reach it. Geochemical modeling of fluids in the interiors of small planetary bodies in the outer Solar System[7] shows that ammonia-bearing H2O in contact with rock and metal components produce a rich chemical soup, including gases that can, in principle, help propel the fluid from shallow reservoirs through crustal fractures to reach the surface. An organic component of the fluid cryomagma is predicted to originate from thermal processing of the components [ref] and may be an example of one-pot synthesis of such complexes as amino acid precursors [ref].

Dale P Cruikshank↗

An Innovative Zero-Liquid Discharge Intermediate-Cold-Liquid Eutectic-Freeze Desalination System

A novel freeze desalination technology is presented for purification of water produced from various industrial processes, including oil and gas extraction. The main innovative idea is introducing a water-immiscible intermediate-cold-liquid (ICL) medium which absorbs the cold from a refrigeration cycle and transfers it to a freezing chamber where it is mixed with brine. The cold ICL enters the freezing chamber at temperatures between -10°C to -30°C. Precooled brine in injected into the freezing chamber and pure water freezes out of the brine upon mixing with the ICL. The rate of freezing inside the chamber is controlled by adjusting the flow rate of the cold ICL relative to the inlet brine. Both eutectic freeze and non-eutectic freezing are possible by controlling the temperature of the freezing chamber. The solid-liquid slurry created in the freezing chamber flows to a filter separation unit after passing through a separation column. The ice crystals are separated from the liquid by a rotary filter device. The collected ice is rinsed by a centrifugal unit. The rinsed ice is melted to produce fresh water. The developed technology resolves the issues common to current freeze-desalination systems while offering superior heat transfer performance ascribed to direct-contact between the cooling medium and the brine in addition to producing solid salt and pure water. The system operates under atmospheric pressure. The low operation temperature minimizes the corrosion issues common in systems exposed to brine. Also, due to the low operating temperature, there are no concerns about evaporation of volatile organics from the produced water during the treatment. The developed technology effectively eliminates the use of chemicals for pretreatment of brine. The system can be constructed from commercially available components. Extensive testing using a lab-scale prototype by using synthetic brine and actual produced water with TDS values from 50,000 ppm to 300,000 ppm showed that freshwater could be achieved with relatively small dependency on the quality of the input brine. The quality of the treated water was found to be mainly a function of the duration of the centrifugal process. Treated water with TDS as low as 200 ppm could be achieved in the tests. Thermo-economic modeling coupled with system level thermochemical process model were developed for prediction of the LCOW. The LCOW was predicted to be $\$$0.50 to $\$$0.90 per barrel of produced water. The potential markets for deployment of the technology are the oil and gas, in-land thermoelectric powerplants, RO desalination plants, and mining industry.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A Theoretical Model for Computing Freezing Point Depression of Lithium-Ion Battery Electrolytes

Reliable prediction of freezing point depression in liquid electrolytes will accelerate the development of improved Li-ion batteries which can operate in low temperature environments. In this work we establish a computational methodology to calculate activity coefficients and liquidus lines for battery-relevant liquid electrolytes. Electronic structure methods are used in conjuction with classical molecular dynamics simulations and theoretical expressions for Born solvation energy, ion-atmosphere effects from Debye-Hückel theory and solvent entropic effects. The framework uses no a priori knowledge beyond neat solvent properties and the concentration of salt. LiPF 6 in propylene carbonate (PC), LiPF 6 in dimethyl carbonate (DMC) and LiClO 4 in DMC are investigated up to 1 molal with accuracy better than 3 °C when compared to experimental freezing point measurements. Finally, we find that the difference in freezing point depression between the propylene carbonate-based electrolyte and the dimethyl carbonate electrolytes originates from the difference in the solvent dielectric constant.

25 ENERGY STORAGE↗

AmeriFlux AR-Cel CELPA Mar Chiquita BA

This is the AmeriFlux version of the carbon flux data for the site AR-Cel CELPA Mar Chiquita BA. Site Description - The site is located at a mid-latitude South Atlantic pristine salt marsh. It occupies 43 km2 of an extended marginal flat surrounding a 25 km long brackish lagoon connected with the Argentine Sea through an inlet channel. The small tide amplitude prevents extensive waterlogging with salt water. Unlike other Northern Hemisphere salt marshes regularly flooded by daily tides, Mar Chiquita soaks throughout the winter with approximately a 10 cm freshwater layer coming from rains, and during summer high temperatures and high evapotranspiration dry the soil, producing a thin salt crust on the surface. Another significant difference is that the canopy persists throughout the year without dying out, due to the lack of snowfall or below-freezing winter temperatures.

Gassmann, Maria Isabel↗

Salt Vessel-Sample Generator Interface

The goal of the salt sampling program at Argonne is to develop and deploy automated molten salt sampling approaches for interfacing relevant unit operations with salt analysis to improve the timeliness and accuracy of sampling-based accountancy measurements. One technology under development is a vacuum sampler loop module. In this system, molten salt is drawn from a process vessel through a heated sampling line and into a charge vessel. Next, one or more samples are split from the volume in the charge vessel and the remaining salt is returned to the process. The vacuum sampler loop module is being developed to interface with other sample processing and analysis modules to enable rapid at-line sample characterization. The main purpose of the vacuum sampling loop module is to enable the collection of samples that are more representative of the bulk salt by replacing traditional point samplers (i.e., dip probes) with a sampling approach that captures a larger cross section of salt. Additionally, the vacuum sampling approach eliminates the risk of dross contamination of samples and avoids the use of moving parts in the salt. Two methods of interfacing the vacuum sampling loop with a precision pneumatic sample generator were investigated in FY21. This report covers the testing of fluidic coupling between the two modules. Two iterations of the fluidically coupled modules were tested. The first iteration system coupled the two modules using a freeze valve to seal the vacuum sampler during filling and to control flow into the pneumatic sample generator. While this integrated system functioned as intended, some changes were implemented to make the system more robust and better suited to remote deployment. Specifically, the system was made to be more modular and active control of the vacuum filling operation was replaced with a passive control mechanism. For passive filling, the salt charge vessel was vented to a small gas tank that was at negative pressure, causing salt to be drawn into the vessel until the force of the fluid head was in equilibrium with the gas pressure. The passive control system performed well and will be used in future iterations. Another change in the second system was a newly configured pneumatic sample generator in which sample ejection occurred through a hole in the reservoir’s stainless-steel side wall instead of through a non-wetted sapphire orifice on the bottom. This alternate configuration may be better suited for near-process deployment because it enables on-line orifice maintenance and an orifice bypass drain back to the process. A third change in the second iteration system was the transition to a two-chamber charge vessel which split off a fraction of the sampled salt as a liquid aliquot. The goal was to create a buffer mechanism that would allow reproducible aliquoting of samples, independently of variability in the charge vessel fill height. While the two-chamber design was functional, the sample size reproducibility was below target values. To improve reproducibility and overcome many of the impediments to remote deployment of the vacuum sampling loop module, separate work was conducted to replace the two-chamber liquid aliquoting mechanism with aliquoting into single-use sample tubes. Solid salt transfer in the sample tubes will replace fluidic coupling for integrating the vacuum sampler with downstream modules. Because the proposed operations can all be executed with simple overhead actuation mechanisms or other existing hot-cell technology, there will be no need for large investments in novel hot cell sample handling technologies using this alternate approach. As such, near-term deployment of the vacuum sampling technology will be achievable. This new approach for automated coupling of sample tubes with down-stream modules is covered in a separate FY21 report, and a remotely operated version of the vacuum sampler loop module with the tube aliquoting feature is planned for FY22.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Phase diagram of KHF2 and non-equilibrium effects

The equilibrium diagram for the KHF2-H2O system was constructed from cooling and heating curves for the compositions between 5 wt% and 40 wt% KHF2 and the results are shown. The phase diagrams shown is typical of that of a two component system with miscible liquid phases and whole solid phases consist of pure components. A eutectic point was found at approximately 15% KHF2 which remains completely liquid down to a temperature of -9.0 C. No hydrate formation was observed and no anomalous behavior such as the occurrence of solid transitions or metastable states was observed. The effect of rapid freezing on the equilibrium diagram did not appear, and cooling curves exhibited only one halt. Also, at rapid freezing rates, the supercooling of the solutions was smaller than those observed at the slow cooling rates. The existence of a eutectic composition and the slow rate of dissolution of the salt are used to interpret heat absorption behavior in practical applications of the KHF2-H2O system.

Hobson, M. C.↗