Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sample geometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Buoyant Effects on the Flammability of Silicone Samples Planned for the Spacecraft Fire Experiment (Saffire)

Flammability experiments on silicone samples were conducted in anticipation of the Spacecraft Fire Experiment (Saffire). The sample geometry was chosen to match the NASA 6001 Test 1 specification, namely 5 cm wide by 30 cm tall. Four thicknesses of silicone (0.25, 0.36, 0.61 and 1.00 mm) were examined. Tests included traditional upward buoyant flame spread using Test 1 procedures, downward opposed flow flame spread, horizontal and angled flame spread, forced flow upward and downward flame spread. In addition to these configurations, upward and downward tests were also conducted in a chamber with varying oxygen concentrations. In the upward buoyant flame spread tests, the flame generally did not burn the entire sample. As thickness was increased, the flame spread distance decreased before flame extinguishment. For the thickest sample, ignition could not be achieved. In the downward tests, the two thinnest samples permitted the flame to burn the entire sample, but the spread rate was lower compared to the corresponding upward values. The other two thicknesses could not be ignited in the downward configuration. The increased flammability for downward spreading flames relative to upward ones is uncommon. The two thinnest samples also burned completely in the horizontal configuration, as well as at angles up to 75 degrees from the horizontal. The upward and downward flammability behavior was compared in atmospheres of varying oxygen concentration to determine a maximum oxygen concentration for each configuration. Upward tests in air with an added forced flow were more flammable. Complementary analyses using SEM and TGA techniques suggest the importance of the silica layer formed on the burned sample surface. As silicone burns upward, silica deposits downstream •If the silicone is ignited in the downward configuration, it burns the entire length of the sample •Burning upward at an angle increases the burn length in some cases possibly due to less silica deposition •Forced flow in the upward burning case increases flammability, likely due to an increase in convective flow preventing silica from depositing •Samples in upward configuration burning under forced flow self extinguish after forced flow is removed

Flammability↗

Detection and imaging of chemicals and hidden explosives using terahertz time-domain spectroscopy and deep learning

Detecting concealed chemicals and explosives remains a critical challenge in global security. Terahertz time-domain spectroscopy (THz-TDS) offers a promising non-invasive and stand-off detection technique owing to its ability to penetrate optically opaque materials without causing ionization damage. While many chemicals exhibit distinct spectral features in the terahertz range, conventional terahertz-based detection methods often struggle in real-world environments, where variations in sample geometry, thickness, and packaging can lead to inconsistent spectral responses. In this study, we present a chemical imaging system that integrates THz-TDS with deep learning to enable accurate pixel-level identification and classification of different explosives. Operating in reflection mode and enhanced with plasmonic nanoantenna arrays, our THz-TDS system achieves a peak dynamic range of 96 dB and a detection bandwidth of 4.5 THz, supporting practical, stand-off operation. By analyzing individual time-domain pulses with deep neural networks, the system exhibits strong resilience to environmental variations and sample inconsistencies. Blind testing across eight chemicals—including pharmaceutical excipients and explosive compounds—resulted in an average classification accuracy of 99.42% at the pixel level. Notably, the system maintained an average accuracy of 88.83% when detecting explosives concealed under opaque paper coverings, demonstrating its robust generalization capability. These results highlight the potential of combining advanced terahertz spectroscopy with neural networks for highly sensitive and specific chemical and explosive detection in diverse and operationally relevant scenarios.

Imaging and sensing↗

Buoyant Effects on the Flammability of Silicone Samples Planned for the Spacecraft Fire Experiment (Saffire)

Flammability experiments on silicone samples were conducted in anticipation of the Spacecraft Fire Experiment (Saffire). The sample geometry was chosen to match the NASA 6001 Test 1 specification, namely 5 cm wide by 30 cm tall. Four thicknesses of silicone (0.25, 0.36, 0.61 and 1.00 mm) were examined. Tests included traditional upward buoyant flame spread using Test 1 procedures, downward opposed-flow flame spread, horizontal and angled flame spread, and forced-flow upward and downward flame spread. In addition to these configurations, upward and downward tests were conducted in a chamber with varying oxygen concentrations. In the upward buoyant flame spread tests, the flame generally did not burn the entire sample. As thickness was increased, the flame spread distance decreased before flame extinguishment. For the thickest sample, ignition could not be achieved. In the downward tests, the two thinnest samples permitted the flame to burn the entire sample, but the spread rate was lower compared to the corresponding upward values. The other two thicknesses could not be ignited in the downward configuration. The increased flammability for downward spreading flames relative to upward ones is uncommon. The two thinnest samples also burned completely in the horizontal configuration, as well as at angles up to 75 degrees from the horizontal. Upward tests in air with an added forced flow were more flammable. The upward and downward flammability behavior was compared in atmospheres of varying oxygen concentration to determine a maximum oxygen concentration for each configuration. Complementary analyses using EDS, TGA, and SEM techniques suggest the importance of the silica layer deposited downstream onto the unburned sample surface.

Flammability↗

Single-Use Destructive Assay for Uranium Hexafluoride Sampling

Sampling uranium hexafluoride (UF6) for the determination of enrichments by destructive analysis (DA) is a critical component in the International Atomic Energy Agency’s layered safeguards approach for uranium processing facilities. Typically, gram-quantity UF6 samples are collected during inspections and stored under tag-and-seal until transportation to an off-site analytical laboratory. The shipping times can be long, and evolving restrictions on radioactive/corrosive materials shipments may increasingly limit the IAEA’s ability to transport UF6 samples easily. Pacific Northwest National Laboratory has developed a low-cost UF6 sampling technology called Single-Use Destructive Assay (SUDA) that addresses these challenges, as well as provides DA sample geometries that can be tailored for different analytical methods, including potential on-site analyses. The SUDA samplers, along with a unique holder, are designed for direct attachment to existing taps at uranium processing facilities, allowing gaseous UF6 to come into direct contact with a zeolite film. The SUDA technology features the ability to capture uranium in a more easily shipped and handled form as the solid, more stable, and relatively less hazardous hydrated uranyl fluoride (UO2F2•nH2O), which is formed through the controlled hydrolysis of UF6. We have recently simulated uranium collection under enrichment plant sampling conditions to further improve our understanding of SUDA sampling. Presented here is our recent work on measuring the relationship between sampling conditions and uranium collection, which includes control of the uranium-mass-to-zeolite ratio and assessing variable UF6 gas and sampling parameters that can affect collection using the SUDA sampler.

Pope, Timothy R.↗

Statistical variability and confidence intervals for planar dose QA pass rates

Purpose: The most common metric for comparing measured to calculated dose, such as for pretreatment quality assurance of intensity-modulated photon fields, is a pass rate (%) generated using percent difference (%Diff), distance-to-agreement (DTA), or some combination of the two (e.g., gamma evaluation). For many dosimeters, the grid of analyzed points corresponds to an array with a low areal density of point detectors. In these cases, the pass rates for any given comparison criteria are not absolute but exhibit statistical variability that is a function, in part, on the detector sampling geometry. In this work, the authors analyze the statistics of various methods commonly used to calculate pass rates and propose methods for establishing confidence intervals for pass rates obtained with low-density arrays. Methods: Dose planes were acquired for 25 prostate and 79 head and neck intensity-modulated fields via diode array and electronic portal imaging device (EPID), and matching calculated dose planes were created via a commercial treatment planning system. Pass rates for each dose plane pair (both centered to the beam central axis) were calculated with several common comparison methods: %Diff/DTA composite analysis and gamma evaluation, using absolute dose comparison with both local and global normalization. Specialized software was designed to selectively sample the measured EPID response (very high data density) down to discrete points to simulate low-density measurements. The software was used to realign the simulated detector grid at many simulated positions with respect to the beam central axis, thereby altering the low-density sampled grid. Simulations were repeated with 100 positional iterations using a 1 detector/cm{sup 2} uniform grid, a 2 detector/cm{sup 2} uniform grid, and similar random detector grids. For each simulation, %/DTA composite pass rates were calculated with various %Diff/DTA criteria and for both local and global %Diff normalization techniques. Results: For the prostate and head/neck cases studied, the pass rates obtained with gamma analysis of high density dose planes were 2%-5% higher than respective %/DTA composite analysis on average (ranging as high as 11%), depending on tolerances and normalization. Meanwhile, the pass rates obtained via local normalization were 2%-12% lower than with global maximum normalization on average (ranging as high as 27%), depending on tolerances and calculation method. Repositioning of simulated low-density sampled grids leads to a distribution of possible pass rates for each measured/calculated dose plane pair. These distributions can be predicted using a binomial distribution in order to establish confidence intervals that depend largely on the sampling density and the observed pass rate (i.e., the degree of difference between measured and calculated dose). These results can be extended to apply to 3D arrays of detectors, as well. Conclusions: Dose plane QA analysis can be greatly affected by choice of calculation metric and user-defined parameters, and so all pass rates should be reported with a complete description of calculation method. Pass rates for low-density arrays are subject to statistical uncertainty (vs. the high-density pass rate), but these sampling errors can be modeled using statistical confidence intervals derived from the sampled pass rate and detector density. Thus, pass rates for low-density array measurements should be accompanied by a confidence interval indicating the uncertainty of each pass rate.

61 RADIATION PROTECTION AND DOSIMETRY↗

Intrinsic and extrinsic effects on the fracture toughness of ductile metallic glasses

The potential application of metallic glasses (MGs) as structural materials demands accurate measurements of their toughness and the understanding of the underlying factors affecting it. Currently, it is challenging to precisely measure the toughness of MGs, especially ductile MGs. Measured toughness values are widely scattered, even for MGs with identical compositions. That is attributed to the combined effect of intrinsic and extrinsic factors including processing, sample geometries, and loading conditions. A fundamental understanding of the influences of these elements is thus of great significance. In the present study, molecular dynamics simulations are performed to investigate the influence of intrinsic and extrinsic effects on the fracture toughness of CuZr MGs. In particular, focused is placed on the effects of cooling rate, notch shape and size, strain rate, and temperature. The results indicate that the fracture toughness of a MG scales with the cooling rate used to prepare it. This is attributed to increased free volume content generated at high cooling rates, which enhances plastic deformation and amplifies the associated energy dissipation during plastic deformation events. Fracture toughness also increases with the strain rate, arguably due to strain rate-induced crack extension delay. Overall, the results demonstrate that the largest fracture toughness are achieved when MG samples are fabricated at high cooling rates and subjected to high strain rate deformation. In addition, results suggest that the fracture toughness decreases with increasing temperature, due to the significant decrease in strength. Here, the correlations revealed between these crucial intrinsic and extrinsic parameters and the calculated MG fracture toughness support the development of a framework to understand the root of the discrepancies in the measurement of the toughness of MGs and provide insights into the design of tough MGs for structural applications.

36 MATERIALS SCIENCE↗

Characterization of tissue magnetic susceptibility-induced distortions for MRIgRT

Purpose: MR image geometric integrity is one of the building blocks of MRI-guided radiotherapy. In particular, tissue magnetic susceptibility-induced effects are patient-dependent and their behavior is difficult to assess and predict. In this study, the authors investigated in detail the characteristics of susceptibility ({chi}) distortions in the context of MRIgRT, including the case of two common MR-linac system configurations. Methods: The magnetic field distortions were numerically simulated for several imaging parameters and anatomical sites, i.e., brain, lung, pelvis (with air pockets), and prostate. The simulation process consisted of (a) segmentation of patient CT data into susceptibility relevant anatomical volumes (i.e., soft-tissue, bone and air/lung), (b) conversion of CT data into susceptibility masks by assigning bulk {chi} values to the structures defined at (a), (c) numerical computations of the local magnetic fields by using a finite difference algorithm, and (d) generation of the geometric distortion maps from the magnetic field distributions. For each patient anatomy, the distortions were quantified at the interfaces of anatomical structures with significantly different {chi} values. The analysis was performed for two specific orientations of the external main magnetic field (B{sub 0}) characteristic to the MR-linac systems, specifically along the z-axis for a bore MR scanner and in the (x,y)-plane for a biplanner magnet. The magnetic field local perturbations were reported in ppm. The metrics used to quantify the geometric distortions were the maximum, mean, and range of distortions. The numerical simulation algorithm was validated using phantom data measurements. Results: Susceptibility-induced distortions were determined for both quadratic and patient specific geometries. The numerical simulations showed a good agreement with the experimental data. The measurements were acquired at 1.5 and 3 T and with an encoding gradient varying between 3 and 20 mT/m by using an annular phantom mimicking the water-air and water-oil {chi} interfaces. For quadratic geometries, the magnitude of field distortion increased rapidly with the size of the inhomogeneity up to about 10 mm and then tended to plateau. This trend became more evident for materials with a larger {Delta}{chi} relative to water. The simulations showed only a slight increase in the maximum distortion values when the B{sub 0} orientation was varied with regard to the shape of the {chi} inhomogeneity. In the case of patient anatomy, the largest distortion values arose at the air-soft-tissue interface. Considering the two MR-linac system configurations and comparing the field distortion values corresponding to all organ structures, the distortions tended to be larger for the biplanar magnet. The authors provide a reference table with ppm values which can be used to easily evaluate the geometric distortions for patient data as a function of B{sub 0} and the strength of the encoding gradient. Conclusions: The susceptibility distortions were quantified as a function of multiple parameters such as the {chi} inhomogeneity size and shape, the magnitude of B{sub 0} and the readout gradient, and the orientation of B{sub 0} with respect to the sample geometry. The analysis was performed for several anatomical sites and corresponding to two B{sub 0} orientations as featured by MR-linac systems.

60 APPLIED LIFE SCIENCES↗

Millimeter-Thick Liquid Crystalline Elastomer Actuators Prepared by-Surface-Enforced Alignment

Here, liquid crystalline elastomers (LCE) are thermally cyclable, compliant actuators with compelling mechanical properties. The large and programmable deformation of LCE has led to numerous functional examinations spanning optics, medical devices, and robotics. A well-established method to prepare complex LCE actuators is to utilize surface-enforced photoalignment. Herein, a facile and scalable approach is reported to circumvent the physical limits of surface-enforced alignment (e.g., samples that are 50 µm or less) to amplify the achievable force output in LCE. Applying an approach termed direct layering, the thermomechanical response of LCE elements prepared with +1 disclination patterns in a range of compositions and thicknesses is contrasted. The design and preparation of +1 disclination patterns and arrays is explored to assess the contribution of sample geometry and overlap to deformation and force output. The methodology detailed in this contribution allows for the preparation of elements ≈1 mm in thickness that are capable of actuating large objects. Furthermore, the fabrication of these elements uniquely enables the realization of mechanical instabilities to hasten the actuation rate in response to thermal change and to enable leaping.

36 MATERIALS SCIENCE↗

Comparison of sparse domain approaches for 4D SPECT dynamic image reconstruction

Purpose: Dynamic imaging (DI) provides additional diagnostic information in emission tomography in comparison to conventional static imaging at the cost of being computationally more challenging. Dynamic single photon emission computed tomography (SPECT) reconstruction is particularly difficult because of the limitations in the sampling geometry present in most existing scanners. We have developed an algorithm Spline Initialized Factor Analysis of Dynamic Structures (SIFADS) that is a matrix factorization method for reconstructing the dynamics of tracers in tissues and blood directly from the projections in dynamic cardiac SPECT, without first resorting to any 3D reconstruction. Methods: SIFADS is different from "pure" factor analysis in dynamic structures (FADS) in that it employs a dedicated spline-based pre-initialization. In this paper, we analyze the convergence properties of SIFADS and FADS using multiple metrics. The performances of the two approaches are evaluated for numerically simulated data and for real dynamic SPECT data from canine and human subjects. Results: For SIFADS, metrics analyzed for reconstruction algorithm convergence show better features of the metric curves vs iterations. In addition, SIAFDS provides better tissue segmentations than that from pure FADS. Measured computational times are also typically better for SIFADS implementations than those with pure FADS. Conclusion: The analysis supports the utility of the pre-initialization of a factorization algorithm for better dynamic SPECT image reconstruction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Image fusion for neutron tomography of nuclear fuel

Image fusion, the process of combining different images together, can be useful to create a more complete picture. In this work, image fusion is applied to neutron tomography of nuclear fuel with the goal of enhancing the information obtained about the fuel. Different reconstruction methods, such as Feldkamp, Davis and Kress filtered back projection and Simultaneous Reconstruction Technique, were combined to enhance image quality. This methodology was shown to reduce noise and ring artifacts without sacrificing sharp edges, allowing for a more accurate representation of sample geometry. Technique enhancements and future applications for the neutron imaging community are also discussed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Effect of Orientation of Weld Line on Formability of Electron Beam-Welded Dissimilar Thickness Titanium Sheets

Recently, manufacturing industries are looking forward to get insight into the influence of weld orientation on formability of tailor-welded blanks (TWBs) of titanium sheets for design and fabrication of lightweight components. Hence, commercially pure titanium (CP Ti) sheets of 1.0 and 1.2 mm thickness were joined together by electron beam welding process using accelerating voltage of 55 kV, beam current of 14.9 mA and welding speed of 865 mm/min. Two different types of TWBs with weld line perpendicular to the rolling direction (WL ⊥ RD) and weld line parallel to the rolling direction (WL || RD) were fabricated, and subsequently, the tensile test, microstructure and microhardness characterizations were conducted to ensure quality of weld. The limiting dome height (LDH) tests were carried out using laboratory-scale setup to evaluate forming behavior of both the above TWBs in terms of FLD, strain distribution, weld line movement and failure location. It was found that the tensile stress–strain response and formability performance of TWBs were significantly influenced by weld line orientation with lower ductility, ultimate tensile strength and LDH in TWB of WL || RD. Moreover, significant weld line movement and non-uniform strain distribution with necking and subsequently fracture were observed away from the weld line in thinner 1.0 mm CP Ti sheets depending on both sample geometry and weld line orientation.

36 MATERIALS SCIENCE↗

Influence of Local Inhomogeneity of Thermomechanical Treatment Conditions on Microstructure Evolution in Aluminum Alloys

The influence of local inhomogeneity of the stress–strain condition on structure and texture evolution during thermomechanical treatment of aluminum alloys is studied in this work. For this purpose, laboratory rolling and plane strain tests that simulated roughing mill thermomechanical modes were performed. For all processes, the local inhomogeneity of structure evolution was estimated. For this purpose, x-ray texture analysis, EBSD and optical microscopy were used. Additionally, the calculations which allow to evaluate local inhomogeneity of stress–strain conditions for the each process were performed. The experimental results were compared with mathematical simulation output. They indicated structure and texture evolution inhomogeneities, especially during the plane strain and industrial rolling processes. In the plane strain test, typical local deformation zones occurred with different resulting grain size and texture effects than those observed in both rolling processes. This difference was mainly associated with different stress states, strain intensity and strain rate distribution throughout the deformation zone. This study demonstrated that the inhomogeneity of these parameters has a strong impact on structure and texture evolution in the first stage of thermomechanical treatment. In the center layer, laboratory rolling could adequately generate the structure and texture effects observed during rolling of ingots in a commercial mill. Plane strain tests can generate useful results only in the case of adequate choice of sample geometry.

36 MATERIALS SCIENCE↗

High-precision determination of iron oxidation state in silicate glasses using XANES

Fe K-edge X-ray absorption near-edge structure (XANES) and Moessbauer spectra were collected on natural basaltic glasses equilibrated over a range of oxygen fugacity (QFM - 3.5 to QFM + 4.5). The basalt compositions and fO{sub 2} conditions were chosen to bracket the natural range of redox conditions expected for basalts from mid-ocean ridge, ocean island, back-arc basin, and arc settings, in order to develop a high-precision calibration for the determination of Fe{sup 3+}/{Sigma}Fe in natural basalts. The pre-edge centroid energy, corresponding to the 1s {yields} 3d transition, was determined to be the most robust proxy for Fe oxidation state, affording significant advantages compared to the use of other spectral features. A second-order polynomial models the correlation between the centroid and Fe{sup 3+}/{Sigma}Fe, yielding a precision of {+-} 0.0045 in Fe{sup 3+}/{Sigma}Fe for glasses with Fe{sup 3+}/{Sigma}Fe > 8%, which is comparable to the precision of wet chemistry. This high precision relies on a Si (311) monochromator to better define the Fe{sup 2+} and Fe{sup 3+} transitions, accurate and robust modeling of the pre-edge feature, dense fO{sub 2}-coverage and compositional appropriateness of reference glasses, and application of a non-linear drift correction. Through re-analysis of the reference glasses across three synchrotron beam sessions, we show that the quoted precision can be achieved (i.e., analyses are reproducible) across multiple synchrotron beam sessions, even when spectral collection conditions (detector parameters or sample geometry) change. Rhyolitic glasses were also analyzed and yield a higher centroid energy at a given Fe{sup 3+}/{Sigma}Fe than basalts, implying that major variations in melt structure affect the relationship between centroid position and Fe{sup 3+}/{Sigma}Fe, and that separate calibrations are needed for the determination of oxidation state in basalts and rhyolites.

43 PARTICLE ACCELERATORS↗

Visible-Light-Initiated Free-Radical Polymerization by Homomolecular Triplet-Triplet Annihilation

Polymerization reactions initiated by ultraviolet light are ubiquitous in scores of industrial applications but would markedly benefit from visible-light activation to overcome stability, energy consumption, light penetration, and sample geometry limitations. The current work leverages visible-light-driven homomolecular triplet-triplet annihilation (TTA) in zinc(II) meso-tetraphenylporphyrin (ZnTPP) to initiate facile free-radical polymerization in trimethylolpropane triacrylate (TMPTA) and methyl acrylate (MA) monomers through ultrafast electron transfer quenching. Selective Q-band (S 1 ) excitation of ZnTPP in the green or yellow sensitizes TTA occurring between two 3 ZnTPP* energized chromophores, ultimately generating the highly reducing S 2 excited state on one ZnTPP molecule (E red = –2.13 V versus saturated calomel electrode, SCE). Subsequently, this S 2 state engages in electron transfer with TMPTA or MA, thereby initiating the radical polymerization process. Bimolecular electron transfer was confirmed through optically gated fluorescence upconversion. In conclusion, FT-IR and EPR spin-trapping experiments verified visible-light-initiated polymerization leading to the formation of well-defined macro- and microscopic objects.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A comparative analysis of numerical approaches for the description of gas flow in clay-based repository systems: From a laboratory to a large-scale gas injection test

There is nowadays a consensus among many countries that geological disposal is a favourable solution for the long-term management. Although different host formations and different barrier systems are under consideration around the world, clay-based materials form an important component for waste isolation in most national programmes. Hence, a good comprehension of the effect of gas flow on the hydro-mechanical behaviour of clay-based soils is essential, both at laboratory and field scale. Task B under the international cooperative project DECOVALEX-2023 has recently shown that, after some enhancement, models can be employed to reproduce laboratory scale tests, even with different sample geometries 37 . However, further work is required to understand whether they can be applied to simulate a large-scale experiment. Up-scaling of models for the advective transport of gas through clay-based low permeable material presents a number of problems related to the difficulty in obtaining consistent hydrogeological parameters and constitutive relationships at both laboratory and field scale. Based on a unique dataset from a large-scale gas injection test (Lasgit) performed at the Äspö Hard Rock Laboratory (Sweden), Task B within DECOVALEX-2023 has explored the refinement of these numerical strategies applied to the simulation of gas flow. Work performed within the task reveals that codes do not need to be substantially modified from the laboratory models to reproduce full-scale tests: indeed, model parameters calibrated and validated at laboratory scale have been applied to predict field scale gas flow at Lasgit, including peak gas pressure and injected cumulative gas volume. By means of (1) the introduction of interfaces between blocks to reflect the experimental configuration and the (2) adjustment of some parameters (e.g., higher permeability), the updated models are able to represent most of the key features observed in the experimental data, even at a large scale.

Tamayo-Mas, E↗

Effect of exposure environment on surface decomposition of SiC-silver ion implantation diffusion couples

SiC is a promising material for nuclear applications and is a critical component in the construction of tristructural isotropic (TRISO) fuel. A primary issue with TRISO fuel operation is the observed release of 110m Ag from intact fuel particles. The release of Ag has prompted research efforts to directly measure the transport mechanism of Ag in bulk SiC. Recent research efforts have focused primarily on Ag ion implantation designs. The effect of the thermal exposure system on the ion implantation surface has been investigated. Results indicate the utilization of a mated sample geometry and the establishment of a static thermal exposure environment is critical to maintaining an intact surface for diffusion analysis. In conclusion, the nature of the implantation surface and its potential role in Ag diffusion analysis are discussed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Empirical and mechanistic transient fission gas release model for high-burnup LOCA conditions

In response to the nuclear industry desire to extend burnup beyond current licensing practices, the US Nuclear Regulatory Commission (NRC) released a research information letter (RIL) that provides a basis for analyzing fuel fragmentation, relocation, and dispersal (FFRD) in light-water reactors. Of the five elements discussed, the most ambiguous is the significance of transient fission gas (FG) release (FGR) (tFGR) and its effects on fuel performance under loss-of-coolant accident conditions. In fresh fuel, FG migration and eventual release is primarily governed by diffusion-based mechanisms at higher temperatures (>1,000 °C). However, the mechanisms governing FGR changes as burnup increases. More recent research indicates that FGR increases as burnup increases, specifically under temperature transient conditions, and this release occurs at lower temperatures with a new release mechanism. This behavior has been attributed to microcracking in the fuel and is likely related to microstructure embrittlement with the presence of over pressurized FG bubbles. The NRC RIL outlines the complexity of the phenomenon and a need for a deeper understanding to adequately address FFRD for regulatory application. Here, therefore, this manuscript intends to summarize the publicly available tFGR data and discuss the observed dependencies (e.g., burnup, heating rate, sample geometry, terminal temperature). An empirical model has been developed and benchmarked against recently published experimental data. However, this empirical model is limited to conditions for which fitting data exist and, therefore, a high-level discussion is included to provide a roadmap for atomistically-informed multiscale modeling in conjunction with experimental data collection to develop a mechanistic tFGR model widely applicable to a broad range of nuclear fuel conditions at high burnup.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗