Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sampling calorimeter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Development of Metallic Magnetic Calorimeters for Nuclear Safeguards Applications

Many nuclear safeguards applications could benefit from high-resolution gamma-ray spectroscopy achievable with metallic magnetic calorimeters. This dissertation covers the development of a system for these applications based on gamma-ray detectors developed at the University of Heidelberg. It demonstrates new calorimeters of this type, which achieved an energy resolution of 45.5 eV full-width at half-maximum at 59.54 keV, roughly ten times better than current state of the art high purity germanium detectors. This is the best energy resolution achieved with a gamma-ray metallic magnetic calorimeter at this energy to date. In addition to demonstrating a new benchmark in energy resolution, an experimental system for measuring samples with metallic magnetic calorimeters was constructed at Lawrence Livermore National Laboratory. This system achieved an energy resolution of 91.3 eV full-width at half-maximum at 59.54 keV under optimal conditions. Using this system it was possible to characterize the linearity of the response, the count-rate limitations, and the energy resolution as a function of temperature of the new calorimeter. With this characterization it was determined that it would be feasible to measure 242Pu in a mixed isotope plutonium sample. A measurement of a mixed isotope plutonium sample was performed over the course of 12 days with a single two-pixel metallic magnetic calorimeter. The relative concentration of 242Pu in comparison to other plutonium isotopes was determined by direct measurement to less than half a percent accuracy. This is comparable with the accuracy of the best-case scenario using traditional indirect methods. The ability to directly measure the relative concentration of 242Pu in a sample could enable more accurate accounting and detection of indications of undeclared activities in nuclear safeguards, a better constraint on source material in forensic samples containing plutonium, and improvements in verification in a future plutonium disposition treaty.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Membrane-based calorimetry for studies of sub-microgram samples.

We have developed a membrane-based microcalorimeter for general measurements of heat capacity and latent heat using a combination of ac steady-state and relaxation methods. The differential calorimeter is designed for sub-microgram samples studied over a wide range of temperatures and magnetic fields. The device is based on free-standing silicon nitride membranes of 150 nm thickness onto which thin film heaters and temperature sensors are fabricated. While production-line fabrication may benefit from back-etching as a final step, it is often easier to start with pre-etched membranes in a research laboratory. With selected nano-fabrication methods this is possible. Due to a robust heater and very low thermal conductance of the final calorimeter, the sample can be heated to more than 100 K above base temperature. This enables instantaneous calibration, and makes the device capable of being used for ultra-fast temperature control, relaxation studies, and measurements that combine good absolute accuracy, high resolution, and information on latent heat.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

CsI(Tl) pulse shape discrimination with the Belle II electromagnetic calorimeter as a novel method to improve particle identification at electron–positron colliders

Here we describe the implementation and performance of CsI(Tl) pulse shape discrimination for the Belle II electromagnetic calorimeter, representing the first application of CsI(Tl) pulse shape discrimination for particle identification at an electron–positron collider. The pulse shape characterization algorithms applied by the Belle II calorimeter are described. Control samples of $γ, μ^+, π^±, K^±$ and $ρ/ \bar{ρ}$ are used to demonstrate the significant insight into the secondary particle composition of calorimeter clusters that is provided by CsI(Tl) pulse shape discrimination. Comparisons with simulation are presented and provide further validation for newly developed CsI(Tl) scintillation response simulation techniques, which when incorporated with GEANT4 simulations allow the particle dependent scintillation response of CsI(Tl) to be modelled. Comparisons between data and simulation also demonstrate that pulse shape discrimination can be a new tool to identify sources of improvement in the simulation of hadronic interactions in materials. The $K^0_L$ efficiency and photon-as-hadron fake-rate of a multivariate classifier that is trained to use pulse shape discrimination is presented and comparisons are made to a shower-shape based approach. CsI(Tl) pulse shape discrimination is shown to reduce the photon-as-hadron fake-rate by over a factor of 3 at photon energies of 0.2 GeV and over a factor 10 at photon energies of 1 GeV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The ALICE Electromagnetic Calorimeter

ALICE is the general purpose experiment at the LHC dedicated to the study of heavy-ion collisions. The electromagnetic calorimeter (EMCal) is a late addition to the ALICE suite of detectors with first modules installed in ALICE this year. The EMCal is designed to trigger on high energy gamma-rays and jets, and to enhance the capabilities of ALICE for these measurements. The EMCal is a Pb/scintillator sampling shish-kebab type calorimeter. The EMCal construction, readout, and performance in beam tests at the CERN SPS and PS are described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nanocrystallization kinetics of amorphous Fe{sub 81}B{sub 13.5}Si{sub 3.5}C{sub 2} magnetic ribbons

The kinetics of the nanocrystallization of amorphous Fe{sub 81}B{sub 13.5}Si{sub 3.5}C{sub 2} ribbon is studied. The changes in the microstructures and magnetic properties of ribbons annealed at 425 and 495 deg. C for 0.5-10 h were investigated using an X-ray diffractometer (XRD), Moessbauer spectroscopy (MS), differential scanning calorimeter (DSC) and vibrating sample magnetometer (VSM). The changes in the surface morphology were observed by a changed atomic force microscope (AFM). The XRD patterns and the Moessbauer spectrums show the formation of nanocrystallites of {alpha}-Fe(Si), Fe-B, Fe{sub 3}C and Fe{sub 3}Si of different grain sizes when annealed at different temperatures. The nanocrystallization kinetics of the Fe{sub 81}B{sub 13.5}Si{sub 3.5}C{sub 2} ribbon are described by an Avrami growth curve with an exponent values of 1.34 and 1.01 for the isothermal annealing at 425 and 495 deg. C, respectively. AFM topography pictures and surface image show that the density of the microstructure and the size of the grain increase as higher annealing temperatures are used.

36 MATERIALS SCIENCE↗

Structural and transport properties of CdSe nanorods

The nanorods of cadmium selenide (CdSe) have been synthesized by soft chemical route. The selected area electron diffraction pattern, high resolution TEM and X-ray diffraction pattern indicate the cubic structure of the sample. The band gap of the sample is obtained using Tauc relation to UV-visible spectrum and found to be 1.92 eV. 1{sup st} order and 2{sup nd} order Raman bands are followed to investigate the behaviour of the phonon modes of the materials which is considered to be important to predict the potential of the material to microwave applications. Thermal behaviour of the sample is investigated using differential scanning calorimeter. Kissinger equation is used to calculate the activation energy of the sample, which is found to be 1.67 eV.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Azimuthal anisotophy in U + U and Au + Au collisions at RHIC

Collisions between prolate uranium nuclei are used to study how particle production and azimuthal anisotropies depend on initial geometry in heavy-ion collisions. We report the two- and four-particle cumulants, v 2 {2} and v 2 {4}, for charged hadrons from U+U collisions at √ S NN = 193 GeV and Au+Au collisions at √ S NN = 200 GeV. Nearly fully overlapping collisions are selected based on the energy deposited by spectators in zero degree calorimeters (ZDCs). Within this sample, the observed dependence of v 2 {2} on multiplicity demonstrates that ZDC information combined with multiplicity can preferentially select different overlap configurations in U+U collisions. As a result, we also show that v 2 vs multiplicity can be better described by models, such as gluon saturation or quark participant models, that eliminate the dependence of the multiplicity on the number of binary nucleon-nucleon collisions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Thermal Screening Of Residues From Acidification And Copper-Catalyzed Peroxide Oxidation Of Tank 48H Simulant

This study evaluated the residues generated from copper-catalyzed peroxide oxidation (CCPO) of Tank 48H simulant. The first step of the CCPO calls for pH adjustment of the simulant, and early testing used either 15wt% or 50wt % nitric acid to reach a slurry pH of between 12 and 5. Residues obtained by ambient temperature pH adjustment with 50wt % nitric acid followed by oxidation with 50 wt % hydrogen peroxide at 35, 50, and 65°C (from a recently conducted Copper Catalyzed Peroxide Oxidation or CCPO) were also analyzed. Slurry samples at pH 7 or lower especially made from adding nitric acid at the process equivalent of one gallon per minute had the largest enthalpy of decomposition. The thermogravimetric characteristics of some samples from the CCPO test generated at pH 9 or lower exhibited rapid weight loss. Taken together, residues generated at pH 9 or lower may be classified as energetic upon decomposition in confined spaces or under adiabatic conditions. Therefore, additional testing is recommended with larger (up to 50mL) samples in an adiabatic calorimeter. To minimize risk of formation of energetic byproducts, an intermediate slurry pH of 9 or greater is recommended following the acidification step in the CCPO and prior to start of peroxide addition. In practice, process temperature needs to reach 150°C or greater to decompose residues obtained a pH 9 or lower which is unlikely. Oxidation temperature had no significant effect on the thermal characteristics of the final residues generated.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ultra-fast hadronic calorimetry

Calorimeters for particle physics experiments with integration time of a few ns will substantially improve the capability of the experiment to resolve event pileup and to reject backgrounds. In this paper the time development of hadronic showers induced by 30 and 60 GeV positive pions and 120 GeV protons is studied using Monte Carlo simulation and beam tests with a prototype of a sampling steel-scintillator hadronic calorimeter. In the beam tests, scintillator signals induced by hadronic showers in steel are sampled with a period of 0.2 ns and precisely time-aligned in order to study the average signal waveform at various locations with respect to the beam particle impact. Simulations of the same setup are performed using the MARS15 code. Both simulation and test beam results suggest that energy deposition in steel calorimeters develop over a time shorter than 2 ns providing opportunity for ultra-fast calorimetry. As a result, simulation results for an “ideal” calorimeter consisting exclusively of bulk tungsten or copper are presented to establish the lower limit of the signal integration window.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sample seal-and-drop device and methodology for high temperature oxide melt solution calorimetric measurements of PuO 2

Thermodynamic properties of refractory materials, such as standard enthalpy of formation, heat content, and enthalpy of reaction, can be measured by high temperature calorimetry. In such experiments, a small sample pellet is dropped from room temperature into a calorimeter operating at high temperature (often 700 °C) with or without a molten salt solvent present in an inert crucible in the calorimeter chamber. However, for hazardous (radioactive, toxic, etc.) and/or air-sensitive (hygroscopic, sensitive to oxygen, pyrophoric, etc.) samples, it is necessary to utilize a sealed device to encapsulate and isolate the samples, crucibles, and solvent under a controlled atmosphere in order to prevent the materials from reactions and/or protect the personnel from hazardous exposure during the calorimetric experiments. We have developed a sample seal-and-drop device (calorimetric dropper) that can be readily installed onto the dropping tube of a calorimeter such as the Setaram AlexSYS Calvet-type high temperature calorimeter to fulfill two functions: (i) load hazardous or air-sensitive samples in an air-tight, sealed container and (ii) drop the samples into the calorimeter chamber using an “off-then-on” mechanism. As a case study, we used the calorimetric dropper for measurements of the enthalpy of drop solution of PuO 2 in molten sodium molybdate (3Na 2 O · 4MoO 3 ) solvent at 700 °C. The obtained enthalpy of –52.21 ± 3.68 kJ/mol is consistent with the energetic systematics of other actinide oxides (UO 2 , ThO 2 , and NpO 2 ). In conclusion, this capability has thus laid the foundation for thermodynamic studies of other Pu-bearing phases in the future.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nuclear heating measurements by in-pile calorimetry: prospective works for a microsensor design

Since 2009 works have been performed in the framework of joint research programs between CEA and Aix-Marseille University. The main aim of these programs is to design and develop in-pile instrumentations, advanced calibration procedure and accurate measurement methods in particular for the new Material Testing Reactor (MTR) under construction in the South of France: Jules Horowitz Reactor (JHR). One major sensor is a specific radiometric calorimeter, which was studied out-of-pile from a thermal point of view and in-pile during irradiation campaigns. This sensor type is dedicated to measurements of nuclear heating (energy deposition rate per mass unit induced by interactions between nuclear rays and matter) inside experimental channels of MTRs. This kind of in-pile calorimeter corresponds to heat flux calorimeter exchanging with the external cooling fluid. This thermal running mode allows the establishment of steady thermal conditions inside the sensor to carry out online continuous measurements inside the reactor (core or reflector). Two main types of calorimeters exist. The first type consists of a single cell calorimeter. It is divided into a sample of material to be tested and a jacket instrumented with two thermocouples or a single thermocouple (Gamma Thermometer). The second, called a differential calorimeter, is composed of two superposed twin cells (a measurement cell containing a sample of material, and a reference cell to remove the heating of the cell body) instrumented with four thermocouples and two electrical heaters. Contrary to a single-cell calorimeter, a differential calorimeter allows the compensation of the parasite nuclear heating of the sensor body or jacket. Moreover, it possesses interesting advantages: thanks to the heaters embedded in the cells, three different measurement methods can be applied during irradiations to quantify nuclear heating. The first one is based on the use of out-of-pile calibration curves obtained by generating a heat source by the Joule Effect inside each calorimetric cell. The second one is a zero method consisting in cancelling the difference in cell responses with an additional energy into the reference cell. The last measurement method is based on current additions in the two calorimetric cells. However, one drawback of the existing differential calorimeter is the size of the sensor: a great length equal to 220 mm and a diameter equal to 18 mm. This current size leads to measurement limitations. This paper will begin with a presentation of these measurement limitations from a bibliographic state. Each limitation will be detailed and in particular in the case of a high nuclear heating level expected, for instance, inside the JHR's core at its highest nominal power. The second part of the paper will develop the scientific skills of each partner in heat sciences, micro technology and nuclear physics necessary to design a new calorimetric micro-system: the advantages of studied microelements such as micro-thermocouples, micro- fluxmeters and micro-heaters will be presented. The last part will discuss preliminary designs. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Upgrading the Fast Calorimeter Simulation in ATLAS

The tremendous need for simulated samples now and even more so in the future, encourages the development of fast simulation techniques. The Fast Calorimeter Simulation is a faster though less accurate alternative to the full calorimeter simulation with GEANT4. It is based on parametrizing the longitudunal and lateral energy deposits of single particles in the ATLAS calorimeter. Principal component analysis and machine learning techniques are used to improve the performance and decrease the memory need compared to the current version of the ATLAS Fast Calorimeter Simulation. The parametrizations are expanded to cover very high energies and very forward detector regions, to increase the applicability of the tool. A prototype of this upgraded Fast Calorimeter Simulation has been developed and first validations with single particles show substantial improvements over the previous version.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Study of antineutrino oscillations using accelerator and atmospheric data in MINOS

The Main Injector Neutrino Oscillation Search (MINOS) is a long baseline experiment that was built for studying the neutrino oscillation phenomena. The MINOS experiment uses high intensity muon neutrino and antineutrino beams created by Neutrinos at the Main Injector facility (NuMI) at the Fermi National Accelerator Laboratory (Fermilab). Neutrino interactions are recorded by two sampling steel-scintillator tracking calorimeters: 0.98\,kton Near Detector at Fermilab, IL and 5.4\,kton Far Detector at the Soudan Underground Laboratory, MN. These two detectors are functionally identical, which helps to reduce the systematic uncertainties in the muon neutrino and antineutrino disappearance measurements. The Near Detector, located 1.04\,km from the neutrino production target, is used to measure the initial beam composition and neutrino energy proximal to the neutrino source. The collected data at the Near Detector is then used to predict energy spectrum in the Far Detector. By comparing this prediction to collected data at the Far Detector, which is 735\,km away from the target, it enables a measurement of a set of parameters that govern the neutrino oscillation phenomenon. \\ \indent The flexibility of the NuMI beam configuration and the magnetization of the MINOS detectors facilitate the identification of $\nu_{\mu}$ and $\bar{\nu}_{\mu}$ charged-current interactions on an event-by-event basis. This enables one to measure neutrino and antineutrino oscillation parameters independently and therefore allows us to test the CPT symmetry in the lepton sector. To enhance the sensitivity of the oscillation parameters measurement, a number of techniques have been implemented. Event classification, shower energy estimation and energy resolution bin fitting, which are described in this dissertation, are three of these techniques. Moreover, the most stringent constraints on oscillation parameters can be achieved by combining multiple data sets. \\ \indent This dissertation reports the measurement of antineutrino oscill! ation parameters using the complete MINOS accelerator and atmospheric data set of charged-current $\bar{\nu}_{\mu}$ events. This set comprises exposures of (i) 3.36\times 10^{20} proton-on-target (POT) in the \bar{\nu}_{\mu}-beam mode, (ii) 10.71\times 10^{20} POT in the \nu_{\mu}-beam mode, and (iii) 37.88 kton yr of atmospheric antineutrinos. The data analysis provides the world's most precise measurement to date on the antineutrino oscillation parameters: $|\Delta \overline{m}^2|=\left( 2.50^{+0.23}_{-0.29}\right) \times 10^{-3} \,eV^2$ and $\sin^2(2\bar{\theta})=0.97^{+0.03}_{-0.08}$. This result is consistent with neutrino oscillation parameters independently measured by MINOS and by others. The difference between antineutrino and neutrino mass-squared splittings is computed to be $|\Delta \overline{m}^2|-|\Delta m^2|=\left(0.13^{+0.23}_{-0.25}\right) \times 10^{-3} \, eV^2$.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Progress Toward Fast Decay Energy Spectroscopy for Actinide Analysis

Decay energy spectroscopy (DES) is an increasingly popular technique for measuring isotopic composition of actinide samples for nuclear safeguards applications. Current approaches for actinide DES utilize milligram-scale external gold absorbers (> 0.1 nJ/K) that are integrated with actinide samples through mechanical kneading and are thermally connected to microcalorimeters using indium or gold wire bonds. This leads to relatively slow sensor rise time and, consequently, limits counting speed to a few counts per second. We are developing faster metallic magnetic calorimeter-based DES by integrating actinide samples with magnetic sensor materials. This reduces signal rise time and enables high counting speed while maintaining the ability to knead the radioactive source with the absorber. We have measured signal rise time of 0.7 μs with a 1.5 mg external gold absorber using this approach. Here, we also demonstrated online DES operation using an Ortec DSPEC 50, a commercially available data acquisition system developed for semiconductor detectors.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Reduction Enhancement Mechanisms of a Low-Grade Iron Ore–Coal Composite by NaCl

The reduction behavior of a low iron grade with high SiO{sub 2} content ore–coal composite was investigated in the temperature range of 1143 K to 1263 K (870 °C to 990 °C). Sodium chloride was chosen as an additive to promote this reduction process. The effect of the sodium chloride addition and its mechanism was also investigated. Results showed that the added sodium chloride could enhance the reduction of wustite to iron due to the decrease of fayalite, and a higher metallization ratio of reduced sample was obtained. Thermogravimetric–differential scanning calorimeter analysis showed that sodium chloride could greatly facilitate the gasification process of coal and, thus, provide sufficient carbon monoxide to the reduction process of iron oxides. Meanwhile, sodium chloride promoted the reduction process of iron ore pellets directly as the coal gasification effect was excluded. Microstructures of reduced sample revealed that sodium chloride broke the structure of ore and enhanced the growth of newly formed iron particles. As the ore–coal composite with mol (C/Fe = 1.4) and 3 mass pct sodium chloride addition was roasted at 1233 K (960 °C) for 55 minutes, a reduced sample with metallization ration of 74.45 pct could be obtained.

36 MATERIALS SCIENCE↗

Electromagnetic and Hadron Calorimeters in the MIPP Experiment

The purpose of the MIPP experiment is to study the inclusive production of photons, pions, kaons, and nucleons in π, K, and p interactions on various targets using beams from the Main Injector at Fermilab. The function of the calorimeters is to measure the production of forward-going neutrons and photons. The electromagnetic calorimeter consists of 10 lead plates interspersed with proportional chambers. It was followed by the hadron calorimeter with 64 steel plates interspersed with scintillator. The data presented were collected with a variety of targets and beam momenta from 5 GeV/c to 120 GeV/c. The energy calibration of both calorimeters with electrons, pions, kaons, and protons is discussed. The resolution for electrons was found to be 0.27/sqrt(E), and for hadrons the resolution was 0.554/sqrt(E) with a constant term of 2.6%. The performance of the calorimeters was tested on a neutron sample.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electromagnetic and hadron calorimeters in the MIPP experiment

The purpose of the MIPP experiment is to study the inclusive production of photons, pions, kaons, and nucleons in {pi}, K, and p interactions on various targets using beams from the Main Injector at Fermilab. The function of the calorimeters is to measure the production of forward-going neutrons and photons. The electromagnetic calorimeter consists of 10 lead plates interspersed with proportional chambers. It was followed by the hadron calorimeter with 64 steel plates interspersed with scintillator. The data presented were collected with a variety of targets and beam momenta from 5 to 120 GeV/c. The energy calibration of both calorimeters with electrons, pions, kaons, and protons is discussed. The resolution for electrons was found to be 0.27/{radical}E, and for hadrons the resolution was 0.554/{radical}E with a constant term of 2.6%. The performance of the calorimeters was tested on a neutron sample.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗