Search NASA⌕ Search

SEARCH · Search NASA

Results for “Scanning techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Elemental Mixing State of Aerosol Particles Collected in Central Amazonia during GoAmazon2014/15

Two complementary techniques, Scanning Transmission X-ray Microscopy/Near Edge Fine Structure spectroscopy (STXM/NEXAFS) and Scanning Electron Microscopy/Energy Dispersive X-ray spectroscopy (SEM/EDX), have been quantitatively combined to characterize individual atmospheric particles. This pair of techniques was applied to particle samples at three sampling sites (ATTO, ZF2, and T3) in the Amazon basin as part of the Observations and Modeling of the Green Ocean Amazon (GoAmazon2014/5) field campaign during the dry season of 2014. The combined data was subjected to k-means clustering using mass fractions of the following elements: C, N, O, Na, Mg, P, S, Cl, K, Ca, Mn, Fe, Ni, and Zn. Cluster analysis identified 12 particle types, across different sampling sites and particle sizes. Samples from the remote Amazon Tall Tower Observatory (ATTO, also T0a) exhibited less cluster variety and fewer anthropogenic clusters than samples collected at the sites nearer to the Manaus metropolitan region, ZF2 (also T0t) or T3. Samples from the ZF2 site contained aged/anthropogenic clusters not readily explained by transport from ATTO or Manaus, possibly suggesting the effects of long range atmospheric transport or other local aerosol sources present during sampling. In addition, this data set allowed for recently established diversity parameters to be calculated. All sample periods had high mixing state indices (χ) that were >0.8. Two individual particle diversity (D i ) populations were observed, with particles <0.5 μm having a D i of ~2.4 and >0.5 μm particles having a D i of ~3.6, which likely correspond to fresh and aged aerosols respectively. The diversity parameters determined by the quantitative method presented here will serve to aid in the accurate representation of aerosol mixing state, source apportionment, and aging in both less polluted and more industrialized environments in the Amazon Basin.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Phased Array Ultrasonic Examination of Reactor Coolant System (Carbon Steel-to-CASS) Dissimilar Metal Weld Mockup Specimen

In the summer of 2009, Pacific Northwest National Laboratory (PNNL) staff traveled to the Electric Power Research Institute (EPRI) NDE Center in Charlotte, North Carolina, to conduct phased-array ultrasonic testing on a large bore, reactor coolant pump nozzle-to-safe-end mockup. This mockup was fabricated by FlawTech, Inc. and the configuration originated from the Port St. Lucie nuclear power plant. These plants are Combustion Engineering-designed reactors. This mockup consists of a carbon steel elbow with stainless steel cladding joined to a cast austenitic stainless steel (CASS) safe-end with a dissimilar metal weld and is owned by Florida Power & Light. The objective of this study, and the data acquisition exercise held at the EPRI NDE Center, were focused on evaluating the capabilities of advanced, low-frequency phased-array ultrasonic testing (PA-UT) examination techniques for detection and characterization of implanted circumferential flaws and machined reflectors in a thick-section CASS dissimilar metal weld component. This work was limited to PA-UT assessments using 500 kHz and 800 kHz probes on circumferential flaws only, and evaluated detection and characterization of these flaws and machined reflectors from the CASS safe-end side only. All data were obtained using spatially encoded, manual scanning techniques. The effects of such factors as line-scan versus raster-scan examination approaches were evaluated, and PA-UT detection and characterization performance as a function of inspection frequency/wavelength, were also assessed. A comparative assessment of the data is provided, using length-sizing root-mean-square-error and position/localization results (flaw start/stop information) as the key criteria for flaw characterization performance. In addition, flaw signal-to-noise ratio was identified as the key criterion for detection performance.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Phased array-based nonlinear wave mixing technique: Application to lack-of-fusion porosity characterization in additively manufactured metals

The objective of this research is to demonstrate the effectiveness of a phased array-based nonlinear wave mixing technique to characterize internal, localized microscale damage in an additively manufactured (AM) component. By using phased arrays for the generation of the incident waves, it is possible to produce a nonlinear wave mixing scanning technique without the need for immersion or changing coupling conditions. The phased arrays can be configured to generate incident waves in multiple directions that meet the resonance conditions required for nonlinear wave mixing at a variety of internal locations. This allows for the scanning of a specimen without the removal and re-coupling of the source transducers, leading to greater scanning speed and repeatability. To demonstrate the accuracy of this phased array wave mixing approach, measurements of acoustic nonlinearity in an AM component are first made with a bulk wave second harmonic generation through thickness measurement. Next, nonlinear wave mixing measurements are made with single element transducers to confirm the sensitivity of the proposed nonlinear wave mixing approach to lack-of-fusion porosity in AM metals. Finally, phased arrays are used to highlight the effectiveness of the proposed nonlinear wave mixing technique in these same AM components.

Acoustics↗

Uniform Beam Simulation Technique for Beam Scans and Machine Learning Studies at Fermilab

Fermilab's neutrino facilities, including NuMI and the upcoming LBNF, use proton beams to produce positively and negatively charged pions and kaons. Detailed simulations are necessary to study particle interactions and beam propagation. To efficiently analyze beam scan effects, we propose a technique to generate multiple simulation samples with high statistics. These samples can be used to develop beamline simulation based machine learning applications. In this technique, we generate a uniformly distributed single simulation data sample. We calculate Gaussian weights for each beam configurations and apply them to post-processing measurements. In this poster, we demonstrate the proposed simulation technique. This technique reduces simulation time and computing resources significantly.

Wickremasinghe, Athula↗

Studies on L-citrulline doped potassium dihydrogen phosphate- A non linear crystal with significant nonlinear properties

Potassium Dihydrogen Phosphate (KDP) single crystal is considered as one of the best representative of nonlinear optical crystals. Recently, amino acids having excellent nonlinear optical characteristics are being investigated as prospective dopants to improve the non linear optical characteristics of KDP. The present work is an attempt in this direction and L citrulline, one of the non essential amino acids showing good non linear optical characteristics is used as the dopant for KDP. Good quality crystals of L-citrulline doped KDP crystals were grown by slow evaporation technique. From the powder X-ray diffraction studies of doped KDP crystal, the structure of the doped crystals was determined by direct method and refined by Pawley method employing Topaz version program using the single crystal X-ray data for pure KDP. The lattice parameters for L citrulline doped KDP are a=7.467A{sup 0}, b=7.467 A{sup 0}, c=6.977 A{sup 0}. The crystal falls into the tetragonal crystal system with space group I42 d. The presence of carbon and oxygen, which are primary components of amino acids, in the EDAX spectrum confirms the effectiveness of doping. The absorption spectra of the doped samples show that the crystals are transparent in the entire visible region. The second harmonic generation efficiency of the doped samples was determined by Kurtz powder technique using the Q-switched Nd:YAG laser beam and is found to be 2.2 times that of KDP. The nonlinear optical properties can be well studied by the open aperture Z scan technique. The open aperture curve exhibits a normalized transmittance valley. The nonlinear absorption coefficient β is obtained by theoretical fitting for two photon absorption. It is inferred that doping KDP with L citrulline has enhanced the nonlinearity considerably. This obviously suggests the potentiality of the crystal as an optical power limiter and also for various optical device applications.

36 MATERIALS SCIENCE↗

Safer and optimized vulnerability scanning for operational technology through integrated and automated passive monitoring and active scanning

Vulnerability scanning of embedded sensors and controllers have a history of causing disruption and malfunction within operation technology environments. Traditional information technology vulnerability scanning generally consists of blunt exercising all or a large population of test conditions to understand how equipment responds. Often the large number and varied conditions of the tests are too much for embedded systems to handle. This paper presents a methodology and framework for integrating passive monitoring and active scanning techniques to optimize the type and amount of necessary active communication tests while achieving acceptable levels of device and vulnerability discovery. Bayesian probability and networks are leveraged for inference to drive the automation of the scanning actions to achieve confidence in discovery. Through inference, selecting the optimal active scans with the least risk and highest confidence impact is possible, thereby eliminating unnecessary scans with uncertain effects. Results of experimenting with real power systems and the following probabilities are provided.

Key Management, ICS, SCADA, Authentication↗

Magnetic Resonance Imaging and Spectroscopy to Assess Leg Muscle Macrostructure and Microstructure in Healthy Older Women: A Feasibility Assessment

Advanced magnetic resonance (MR) scanning techniques, such as diffusion tensor imaging (DTI) and proton MR spectroscopy ({sup 1}H-MRS) permit microstructural evaluation of water diffusivity and intramyocellular lipid content, respectively. We aimed to determine the feasibility of performing advanced MR scanning (proton density [PD] weighted imaging, DTI, and {sup 1}H-MRS) to evaluate properties of leg muscles in older women with respect to: (1) participant recruitment using three community-based strategies; (2) participant tolerance to the MRI scan acquisition protocol; and (3) scan acquisition and analyses protocols.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Thermally stimulated nonlinear refraction in gelatin stabilized Cu-PVP nanocomposite thin films

This article illustrates investigations on thermally stimulated third order nonlinear refraction of Cu-PVP nanocomposite thin films. Cu nanoparticles have been synthesized using chemical reduction method and thin films in PVP matrix have been obtained using spin coating technique. Thin films have been characterized by X-ray diffraction (XRD) and Ultraviolet-visible (UV-vis) spectroscopyfor structural and linear optical studies. Third order nonlinear refraction studies have been performed using closed aperture z-scan technique under continuous wave (CW) He-Ne laser. Cu-PVP nanocomposites are found to exhibit strong nonlinear refractive index stimulated by thermal lensing effect.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Emittance measurements using Vernier Scans during Run 09 (pp at 250 GeV)

Emittance measurements using the vernier scan technique give reliable results for 250 GeV protons even though the transverse beam profiles have non-Gaussian tails. Those non-Gaussian tails were observed for the first time this run at the 250 GeV beam energy. The vernier scan measurements are in excellent agreement with the emittances derived from collision rates and show practically no fill to fill scatter if compared to the latter. The results are consistent with a {beta}* of 0.7 m and round beams. The IPM measurements show a discrepancy of up to 80% compared with the vernier scan data and a fill to fill scatter of up to 30%. If an uncertainty in the beta-function at the location of the IPM is the root cause, this uncertainty seems to be quite large. In any case, such an uncertainty could not explain the fill to fill variations of up to 30% which indicate yet another underlying reason that could explain fill to fill variations (candidates could be beam intensity issues with the IPM, beam position at the IPM, varying background etc.).

43 PARTICLE ACCELERATORS↗

Third order nonlinearity in pulsed laser deposited LiNbO{sub 3} thin films

Lithium niobate (LiNbO{sub 3}) thin films were prepared using pulsed laser deposition technique. Structural properties of the same were examined from XRD and optical band gap of the thin films were measured from transmittance spectra recorded using UV-Visible spectrophotometer. Nonlinear optical properties of the thin films were recorded using Z-Scan technique. The films were exhibiting third order nonlinearity and their corresponding two photon absorption, nonlinear refractive index, real and imaginary part of nonlinear susceptibility were calculated from open aperture and closed aperture transmission curves. From these studies, it suggests that these films have potential applications in nonlinear optical devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Improved Acquisition and Reconstruction for Wavelength-Resolved Neutron Tomography

Wavelength-resolved neutron tomography (WRNT) is an emerging technique for characterizing samples relevant to the materials sciences in 3D. WRNT studies can be carried out at beam lines in spallation neutron or reactor-based user facilities. Because of the limited availability of experimental time, potential imperfections in the neutron source, or constraints placed on the acquisition time by the type of sample, the data can be extremely noisy resulting in tomographic reconstructions with significant artifacts when standard reconstruction algorithms are used. Furthermore, making a full tomographic measurement even with a low signal-to-noise ratio can take several days, resulting in a long wait time before the user can receive feedback from the experiment when traditional acquisition protocols are used. In this paper, we propose an interlaced scanning technique and combine it with a model-based image reconstruction algorithm to produce high-quality WRNT reconstructions concurrent with the measurements being made. The interlaced scan is designed to acquire data so that successive measurements are more diverse in contrast to typical sequential scanning protocols. The model-based reconstruction algorithm combines a data-fidelity term with a regularization term to formulate the wavelength-resolved reconstruction as minimizing a high-dimensional cost-function. Using an experimental dataset of a magnetite sample acquired over a span of about two days, we demonstrate that our technique can produce high-quality reconstructions even during the experiment compared to traditional acquisition and reconstruction techniques. In summary, the combination of the proposed acquisition strategy with an advanced reconstruction algorithm provides a novel guideline for designing WRNT systems at user facilities.

47 OTHER INSTRUMENTATION↗

Corrosion resistance of AZ91D magnesium alloy with electroless plating pretreatment and Ni-TiO{sub 2} composite coating

In this paper, a protective multilayer coating, with electroless Ni coating as bottom layer and electrodeposited Ni-TiO{sub 2} composite coating as top layer, was successfully prepared on AZ91D magnesium alloy by a combination of electroless and electrodeposition techniques. Scanning electron microscopy and X-ray diffraction were employed to investigate the surface, cross-section morphologies and phase structure of coatings, respectively. The electrochemical corrosion behaviors of coatings in 3.5 wt.% NaCl solutions were evaluated by electrochemical impedance spectroscopy, open circuit potential and potentiodynamic polarization techniques. The results showed that the corrosion process of Ni-TiO{sub 2} composite coating was mainly composed of three stages in the long-term immersion test in the aggressive media, and could afford better corrosion and mechanical protection for the AZ91D magnesium alloy compared with single electroless Ni coating. The micro-hardness of the Ni-TiO{sub 2} composite coating improved more than 5 times than that of the AZ91D magnesium alloy.

36 MATERIALS SCIENCE↗

Attosecond transient absorption instrumentation for thin film materials: Phase transitions, heat dissipation, signal stabilization, timing correction, and rapid sample rotation

We present an extreme ultraviolet (XUV) transient absorption apparatus tailored to attosecond and femtosecond measurements on bulk solid-state thin-film samples, specifically when the sample dynamics are sensitive to heating effects. The setup combines methodology for stabilizing sub-femtosecond time-resolution measurements over 48 h and techniques for mitigating heat buildup in temperature-dependent samples. Single-point beam stabilization in pump and probe arms and periodic time-zero reference measurements are described for accurate timing and stabilization. A hollow-shaft motor configuration for rapid sample rotation, raster scanning capability, and additional diagnostics are described for heat mitigation. Heat transfer simulations performed using a finite element analysis allow comparison of sample rotation and traditional raster scanning techniques for 100 Hz pulsed laser measurements on vanadium dioxide, a material that undergoes an insulator-to-metal transition at a modest temperature of 340 K. Experimental results are presented confirming that the vanadium dioxide (VO 2 ) sample cannot cool below its phase transition temperature between laser pulses without rapid rotation, in agreement with the simulations. The findings indicate the stringent conditions required to perform rigorous broadband XUV time-resolved absorption measurements on bulk solid-state samples, particularly those with temperature sensitivity, and elucidate a clear methodology to perform them.

47 OTHER INSTRUMENTATION↗

Poster — Thur Eve — 06: Dose assessment of cone beam CT imaging protocols as part of SPECT/CT examinations

Purpose: To assess radiation dose from the cone beam CT (CBCT) component of SPECT/CT studies and to compare with other CT examinations performed in our institution. Methods: We used an anthropomorphic chest phantom and the 6 cc ion chamber to measure entrance breast dose for several CBCT and diagnostic CT acquisition protocols. The CBCT effective dose was calculated with ImPACT software; the CT effective dose was evaluated from the DLP value and conversion factor, dependent on the anatomic region. The RADAR medical procedure radiation dose calculator was used to assess the nuclear medicine component of exam dose. Results: The entrance dose to the breast measured with the anthropomorphic phantom was 0.48 mGy and 9.41 mGy for cardiac and chest CBCT scans; and 4.59 mGy for diagnostic thoracic CT. The effective doses were 0.2 mSv, 3.2 mSv and 2.8 mSv respectively. For a small patient represented by the anthropomorphic phantom, the dose from the diagnostic CT was lower than from the CBCT scan, as a result of the exposure reduction options available on modern CT scanners. The CBCT protocols used the same fixed scanning techniques. The diagnostic CT dose based on the patient data was 35% higher than the phantom dose. For most SPECT/CT studies the dose from the CBCT component was comparable with the dose from the radiopharmaceutical. Conclusions: The patient radiation dose from the cone beam CT scan can be higher than that from a diagnostic CT and should be taken into consideration in evaluating total SPECT/CT patient dose.

60 APPLIED LIFE SCIENCES↗

Results from Vernier scans during the RHIC 2008 PP Run

Using the vernier scan or Van der Meer scan technique, where one beam is swept stepwise across the other while measuring the collision rate as a function of beam displacement, the transverse beam profiles, the luminosity and the effective cross section of the detector in question can be measured. This report briefly recalls the vernier scan method and presents results from the 100 GeV 2008 RHIC polarized proton (pp) run.

43 PARTICLE ACCELERATORS↗

Chapter 4: Modeling the Cellulosome Using Multiscale Methods

Deriving renewable liquid fuels from biomass using microbial conversion, which utilizes free enzymes or cellulosomes for degrading cell wall material to sugars, is an attractive solution for today's energy challenges. The study of the structure and mechanism of these large macromolecular complexes is an active and ongoing research topic worldwide, with the goal of finding ways to improve biomass conversion using cellulosomes. Here, we present methods for illuminating the structure and function of systems of this size and complexity using molecular modeling. We show examples of these methods as applied to a range of sizes and time scales from atomistic models of enzymatic modules to coarse-grained models of the entire cellulosomal complex of scaffold and enzymes. Normal mode analysis, fluctuations, hydrogen-bond analysis of enzymes, as well as sampling techniques for cellulosome assembly are described and the results presented. For example, the mechanism of the immunoglobulin-like module of GH9 proteins is shown to be determined largely by hydrogen bond networks, and the exact hydrogen bonds were identified. Finally, by using coarse-grained modeling and parameter scanning techniques, the assembly of cellulosomal complexes is shown to be dominated by their size and shape and not by their mass.

09 BIOMASS FUELS↗

Enhanced optical limiting effects in a double-decker bis(phthalocyaninato) rare earth complex using radially polarized beams

Optical limiting (OL) effects can be enhanced by exploiting various limiting mechanisms and by designing nonlinear optical materials. In this work, we present the large enhancement of OL effects by manipulating the polarization distribution of the light field. Theoretically, we develop the Z-scan and nonlinear transmission theories on a two-photon absorber under the excitation of cylindrical vector beams. It is shown that both the sensitivity of Z-scan technique and the OL effect using radially polarized beams have the large enhancement compared with that using linearly polarized beams (LPBs). Experimentally, we investigate the nonlinear absorption properties of a double-decker Pr[Pc(OC{sub 8}H{sub 17}){sub 8}]{sub 2} rare earth complex by performing Z-scan measurements with femtosecond-pulsed radially polarized beams at 800 nm wavelength. The observed two-photon absorption process, which originates from strong intramolecular π–π interaction, is exploited for OL application. The results demonstrate the large enhancement of OL effects using radially polarized beams instead of LPBs.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Patient-specific radiation dose and cancer risk estimation in CT: Part II. Application to patients

Purpose: Current methods for estimating and reporting radiation dose from CT examinations are largely patient-generic; the body size and hence dose variation from patient to patient is not reflected. Furthermore, the current protocol designs rely on dose as a surrogate for the risk of cancer incidence, neglecting the strong dependence of risk on age and gender. The purpose of this study was to develop a method for estimating patient-specific radiation dose and cancer risk from CT examinations. Methods: The study included two patients (a 5-week-old female patient and a 12-year-old male patient), who underwent 64-slice CT examinations (LightSpeed VCT, GE Healthcare) of the chest, abdomen, and pelvis at our institution in 2006. For each patient, a nonuniform rational B-spine (NURBS) based full-body computer model was created based on the patient's clinical CT data. Large organs and structures inside the image volume were individually segmented and modeled. Other organs were created by transforming an existing adult male or female full-body computer model (developed from visible human data) to match the framework defined by the segmented organs, referencing the organ volume and anthropometry data in ICRP Publication 89. A Monte Carlo program previously developed and validated for dose simulation on the LightSpeed VCT scanner was used to estimate patient-specific organ dose, from which effective dose and risks of cancer incidence were derived. Patient-specific organ dose and effective dose were compared with patient-generic CT dose quantities in current clinical use: the volume-weighted CT dose index (CTDI{sub vol}) and the effective dose derived from the dose-length product (DLP). Results: The effective dose for the CT examination of the newborn patient (5.7 mSv) was higher but comparable to that for the CT examination of the teenager patient (4.9 mSv) due to the size-based clinical CT protocols at our institution, which employ lower scan techniques for smaller patients. However, the overall risk of cancer incidence attributable to the CT examination was much higher for the newborn (2.4 in 1000) than for the teenager (0.7 in 1000). For the two pediatric-aged patients in our study, CTDI{sub vol} underestimated dose to large organs in the scan coverage by 30%-48%. The effective dose derived from DLP using published conversion coefficients differed from that calculated using patient-specific organ dose values by -57% to 13%, when the tissue weighting factors of ICRP 60 were used, and by -63% to 28%, when the tissue weighting factors of ICRP 103 were used. Conclusions: It is possible to estimate patient-specific radiation dose and cancer risk from CT examinations by combining a validated Monte Carlo program with patient-specific anatomical models that are derived from the patients' clinical CT data and supplemented by transformed models of reference adults. With the construction of a large library of patient-specific computer models encompassing patients of all ages and weight percentiles, dose and risk can be estimated for any patient prior to or after a CT examination. Such information may aid in decisions for image utilization and can further guide the design and optimization of CT technologies and scan protocols.

60 APPLIED LIFE SCIENCES↗