At least 91 records · Page 5

Neutron Response of the EJ-254 Boron-Loaded Plastic Scintillator

Organic scintillators doped with capture agents provide a detectable signal for neutrons over a broad energy range. This work characterizes the fast and slow neutron response of EJ-254, an organic plastic scintillator with 5 loading by weight. For fast neutrons, the primary mechanism for light generation in organic scintillators is n-p elastic scattering. To study the fast neutron response, the proton light yield of EJ-254 was measured at the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory. Using a broad-spectrum neutron source and a double time-of-flight technique, the EJ-254 proton light yield was obtained over the energy range of approximately 270 keV to 4.5 MeV and determined to be in agreement with other plastic scintillators comprised of the same polymer base. To isolate the slow neutron response, an AmBe source with polyethylene moderator was made incident on the EJ-254 scintillator surrounded by an array of EJ-309 observation detectors. Events in the EJ-254 target coincident with the signature 477.6 keV γ ray (resulting from de-excitation of the residual 7Li nucleus following boron neutron capture) were identified. Pulse shape discrimination was used to evaluate the temporal differences in the response of EJ-254 scintillation signals arising from γ-ray and fast/slow neutron interactions. Clear separation between γ-ray and fast neutrons signals was not achieved and the neutron capture feature was observed to overlap both the γ-ray and fast neutron bands. Taking into account the electron light nonproportionality, the neutron capture light yield in EJ-254 was determined to be 89.4±1.1 keVee.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast and bright scintillators for ultrafast materials dynamics using 4th generation synchrotron

We present recent advances in fast and bright scintillators for ultrafast X-ray phase contrast imaging of dynamic materials experiments at the upgraded Advanced Photon Source (APS-U), a fourth generation synchrotron. APS-U enables hard X-ray imaging at frame rates of at least 13 MHz (corresponding to 77 ns or shorter interframe intervals), creating a new need for scintillators with faster response and higher light output than lutetium yttrium oxyorthosilicate (LYSO). For indirect imaging and diffraction with ultrafast cameras, commercial lanthanum bromide (LaBr3) and cerium bromide (CeBr3) are promising candidates. These materials exhibit decay times approximately a factor of two shorter than LYSO (around 40 ns) and lutetium oxyorthosilicate (LSO), while maintaining comparable light yield per incident X-ray photon. However, their implementation at APS-U requires addressing several challenges, including material limitations due to hygroscopicity, efficient optical coupling to imaging systems, and high quantum efficiency for conversion of scintillation light, predominantly at wavelengths below 400 nm, into detectable electronic signals. We report results from material characterization, detector integration and packaging, and beamline experiments of materials with impact. In addition, emerging scintillator classes, including perovskites and high-entropy materials, are discussed as potential alternatives for next-generation ultrafast X-ray diagnostics.

Wang, Zhehui [Los Alamos] (ORCID:0000000178264063)↗

Measuring Light Yield with Isolated Protons in MicroBooNE

Liquid Argon Time Projection Chambers (LArTPCs) are precision detectors used extensively in neutrino physics. The MicroBooNE experiment at Fermilab is one of the experiments employing this technique and has collected 5 years of data from 2015-2021. The primary signal in LArTPCs is ionisation, but argon also emits large quantities of scintillation light, which can be used for calorimetry, timing and background rejection. Prompt scintillation light in MicroBooNE is recorded with an array of 32 PhotoMultiplier Tubes (PMTs). To enable the full use of scintillation light in the experiment, it is important to characterize the efficiency of light collection in the detector, i.e. the light yield. We present a new method of measuring the light yield using isolated proton interactions, which enables a position-dependent light yield measurement to map the response of the detector across its volume. This method can be used to calibrate the light response in large-scale LArTPC detectors as well as to test assumptions used in simulating scintillation light.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Systematic study of radioluminescence and light propagation effects in scintillating nanoguide materials

Nanoguide optical waveguides are thermally processed materials based on polymers that have different refractive indices. Scintillating versions of these materials have been under development since 2019 and feature PMMA as the low refractive index constituent and Organic Glass Scintillator-polymer blends as the high index component. Characterization efforts to date have focused on the functional characteristics of nanoguide pertaining to its envisioned use in high-resolution transmission radiography applications.

36 MATERIALS SCIENCE↗

Impulse response measurements of fast scintillator-based current mode detectors

In this study, experimental measurements were performed to characterize the impulse response of seven different gamma ray detector prototypes being considered to be fielded as a current mode diagnostic for neutron-diagnosed subcritical experiments at the Nevada National Security Site (NNSS). For such experiments, the impulse response of the fielded detector is required to have a full-width half-maximum (FWHM) of approximately 5 ns or less and a low amplitude tail. Each of the detector prototypes evaluated in this work were selected based on the potential to meet this performance requirement. An impulse of bremsstrahlung x-rays created from 2 MeV electrons from the NNSS’s Transformational Diagnostics and Imaging, Los Alamos, linear accelerator was measured with each detector. The measured impulse response was evaluated for each detector configuration. A comparison of these impulse responses revealed a relationship between fast timing performance and scintillator material, geometry, surface reflectivity conditions, and photomultiplier tube (PMT) selection. The detector configuration yielding an impulse response with the shortest FWHM of 3.82 ± 0.11 ns and possessing a low amplitude tail was a 5-inch (12.7-cm) diameter, 5-inch (12.7-cm) height cylindrical EJ-399-17-VI liquid scintillator in a black-painted housing coupled to an Adit D798B 5-inch (12.7-cm) PMT by means of a 0.079-inch (0.2-cm) EJ-560 optical coupling pad.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of Hamamatsu VUV4 SiPMs for detecting liquid argon scintillation

Detection of light signals is crucial to a wide range of particle detectors. In particular, efficient detection of vacuum ultraviolet (VUV) light will provide new opportunities for some novel detectors currently being developed, but is technically challenging. In this paper, we characterized the performance of Hamamatsu VUV4 silicon photomultipliers (SiPMs) for detecting VUV argon scintillation light without wavelength shifting. Using a customized cryogenic amplifier design, we operated two models of VUV4 SiPMs inside liquid argon and thoroughly examined their direct sensitivities to liquid argon scintillation. In addition to describing their cryogenic performance, we measured a photon detection efficiency of 14.7 +1.1 -2.4 % and 17.2 +1.6 -3.0 % at 128 nm for these two VUV4 models for operation at 4 V of overvoltage, with the main uncertainty arising from the SiPM reflectivity for VUV light.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Plastic scintillators stable for operating in wide ranges of humidity and temperature variations

To provide efficient and reproducible response to nuclear radiation, scintillating plastics should be prepared as materials of high optical transparency and homogeneity that should remain intact during the lifetime of their operation. A problem with traditionally used polyvinyltoluene (PVT) or polystyrene (PS) plastic scintillators arises from their exposure to repeated large temperature swings that cause surface and volume defects, resulting in decreased sensitivity of the detection properties. We find that the problem can be avoided by composition modifications that enable preparation of plastics with properties that are resistant to the continuous variations in environmental conditions. This paper describes improvements in physical properties that can be achieved by the addition of crosslinkers (such as divinylbenzene, DVB) and oxygen-containing compounds or copolymers (e.g. polymethylamethacrylate, PMMA) to the traditional PVT or PS polymer matrices. Results of characterization show that the new materials can be prepared with the scintillation performance equal to that of commercial plastic scintillators, such as EJ-200.

36 MATERIALS SCIENCE↗

Thermonuclear neutron emission from a sheared-flow stabilized Z-pinch

We report the fusion Z-pinch experiment (FuZE) is a sheared-flow stabilized Z-pinch designed to study the effects of flow stabilization on deuterium plasmas with densities and temperatures high enough to drive nuclear fusion reactions. Results from FuZE show high pinch currents and neutron emission durations thousands of times longer than instability growth times. While these results are consistent with thermonuclear neutron emission, energetically resolved neutron measurements are a stronger constraint on the origin of the fusion production. This stems from the strong anisotropy in energy created in beam-target fusion, compared to the relatively isotropic emission in thermonuclear fusion. In dense Z-pinch plasmas, a potential and undesirable cause of beam-target fusion reactions is the presence of fast-growing, “sausage” instabilities. This work introduces a new method for characterizing beam instabilities by recording individual neutron interactions in plastic scintillator detectors positioned at two different angles around the device chamber. Histograms of the pulse-integral spectra from the two locations are compared using detailed Monte Carlo simulations. These models infer the deuteron beam energy based on differences in the measured neutron spectra at the two angles, thereby discriminating beam-target from thermonuclear production. An analysis of neutron emission profiles from FuZE precludes the presence of deuteron beams with energies greater than 4.65 keV with a statistical uncertainty of 4.15 keV and a systematic uncertainty of 0.53 keV. This analysis demonstrates that axial, beam-target fusion reactions are not the dominant source of neutron emission from FuZE. These data are promising for scaling FuZE up to fusion reactor conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Performance of novel VUV-sensitive Silicon Photo-Multipliers for nEXO

Liquid xenon time projection chambers are promising detectors to search for neutrinoless double beta decay (0νββ), due to their response uniformity, monolithic sensitive volume, scalability to large target masses, and suitability for extremely low background operations. The nEXO collaboration has designed a tonne-scale time projection chamber that aims to search for 0νββ of 136 Xe with projected half-life sensitivity of 1.35 x 10 28 yr. To reach this sensitivity, the design goal for nEXO is ≤1% energy resolution at the decay Q-value (2458.07 ± 0.31 keV). Reaching this resolution requires the efficient collection of both the ionization and scintillation produced in the detector. The nEXO design employs Silicon Photo-Multipliers (SiPMs) to detect the vacuum ultra-violet, 175 nm scintillation light of liquid xenon. This paper reports on the characterization of the newest vacuum ultra-violet sensitive Fondazione Bruno Kessler VUVHD3 SiPMs specifically designed for nEXO, as well as new measurements on new test samples of previously characterised Hamamatsu VUV4 Multi Pixel Photon Counters (MPPCs). Various SiPM and MPPC parameters, such as dark noise, gain, direct crosstalk, correlated avalanches and photon detection efficiency were measured as a function of the applied over voltage and wavelength at liquid xenon temperature (163 K). The results from this study are used to provide updated estimates of the achievable energy resolution at the decay Q-value for the nEXO design.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Characterization of Silicon-Photomultipliers for a Cosmic Muon Veto detector

A Cosmic Muon Veto (CMV) detector using extruded scintillators is being designed around the mini-Iron Calorimeter detector at the transit campus of the India-based Neutrino Observatory, Madurai for measuring its efficiency at shallow depth underground experiments. The scintillation signal is transmitted through a Wavelength Shifting (WLS) fibre and readout by Hamamatsu Silicon-Photomultipliers (SiPMs). A Light Emitting Diode (LED) system is included on the front-end readout for in-situ calibration of the gain of each SiPM. A characterization system was developed for the measurement of gain and choice of the overvoltage (V ov ) of SiPMs using the LED as well as a cosmic muon telescope. The V ov is obtained by studying the noise rate, the gain of the SiPM, and the muon detection efficiency. In case of any malfunction of the LED system during the operation, the SiPM can also be calibrated with the noise data as well as using radioactive sources. Furthermore, this paper describes the basic characteristics of the SiPM and the comparison of the calibration results using all three methods, as well as the V ov of the SiPMs and muon selection criteria for the veto detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Integrated soft snake robot for gamma spectroscopy of radiologically contaminated ducting

Anticipated growth in the number and complexity of nuclear facilities entering the decommissioning phase of their lifespan requires innovative methods of mitigating radiological and safety hazards for workers. Advancements in robotics provide opportunities for remote characterization of radiologically contaminated ducts and pipes, reducing worker exposure. However, the nuclear decommissioning industry has shown a hesitancy in adopting new technology due to concerns regarding capital costs and a lack of demonstration data in representative environments. This work aims to leverage novel soft robotics to develop and demonstrate a sensor-integrated characterization tool for contaminated ducting systems. Two gamma spectrometers – one scintillation-based and one solid-state – were selected and integrated into a pneumatically-actuated snake-like soft robot using stretchable electronic cabling. The robot was then demonstrated at the Idaho National Laboratory’s Critical Infrastructure Test Range Complex. The robot maneuvered through a pseudo-constrained corridor containing several sealed sources and the integrated spectrometers collected spectra at various points along the path of travel. Both spectrometers successfully collected spectra with identifiable, isotope-specific peaks. To evaluate the effect of contamination buildup on the collected spectra, the robot with the integrated scintillation detector was tested using a liquid radioactive source. The resulting spectra showed little detection interference from the liquid contamination; however, a short-lived isotope was used which may not be representative of longer-lived contamination.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Lithium indium diselenide — An advanced material for neutron detection

Here, this paper describes the synthesis, crystal growth, detector fabrication, radiation hardening studies, MCNP modeling, and characterization of lithium indium diselenide or LiInSe 2 . This newly-developed room temperature thermal neutron detector has semiconducting and scintillating properties and it is suitable for neutron detection application. LiInSe 2 was synthesized starting from elemental Li, In, Se in two steps due to high reactivity of Li. A single crystal of LiInSe 2 was grown using the Vertical Bridgman method. The room temperature band gap was found to be 2.8 eV using optical absorption measurements. Bulk resistivity was measured at ∼5 × 10 11 Ωcm. Photoconductivity measurements of LiInSe 2 wafers identified a peak in the photocurrent around 445 nm. Nuclear radiation detectors were fabricated from single crystal wafer and the responses to alpha particles at various biases were measured. The mobility-lifetime product was estimated. Gamma irradiation studies were performed with calculated absorbed doses ranging from 0.2126 to 21,262 Gy. The characterization of the two wafers for their scintillator performance was conducted after each irradiation. The gamma irradiation produced a reduction of the light yield that translated to a lower channel number for the centroid of alpha detection spectra. It also showed a considerable reduction of the decay time after the first irradiation. These are the first studies on gamma radiation hardening with this material.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sub-critical assembly die-away analysis with organic scintillators

Determining the reactivity of systems containing fissile material is essential for verifying safety, and possession and enrichment levels. The goal of this experiment was to characterize a subcritical nuclear fuel assembly irradiated by a pulsed neutron generator through differential die-away analysis. Similar characterizations are commonly performed with thermal neutron detectors, but these detectors are bulky and cumbersome, the materials are not widely available, and timing can be clouded by the required thermalization time. In this work, an organic scintillator capable of detecting both neutrons and photons was used to measure the die-away profiles of both particles. These time profiles were then used to estimate the reactivity of the assembly. Here, the calculated reactivity estimates compare favorably to simulated estimates, and therefore provide a useful tool for fissile material characterization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gamma Equipment System Requirements by Application

This document outlines a set of requirements for gamma sensitive systems applied to three different applications: (1) homeland security (search and identification); (2) in-situ quantification; and (3) quantification in a material characterization laboratory. These three applications represent a range of activities that a country might use for locating, identifying, and quantifying radioactive material. These applications require increasing accuracy and system advancements, and skill levels. This document considers systems with various detector types and are characterized by their energy resolution: (1) low resolution (e.g., NaI(Tl) scintillation) and (2) higher resolution (e.g., high-purity germanium [HPGe] solid state) systems. The higher resolution systems also include cadmium zinc telluride (CZT) and only mechanically cooled HPGe systems are considered. These detectors and their associated acquisition hardware and analysis software afford a broad range of capabilities with corresponding ranges of complexity, maintainability, and cost. Ultimately, the equipment must meet the measurement goals of the application, and compliance with a given list of hardware specifications does not in itself guarantee meeting those goals. Examples of typical performance objectives for international safeguards applications are documented in International Target Values 2010 for Measurement Uncertainties in Safeguarding Nuclear Materials (IAEA, STR-368, November 2010). Selection of the detector type best suited to a specific application is often a compromise between “state of the art” or best available option and what is practical.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of Neutron Emission Rates of Commercial 252 Cf Sources

Accurate knowledge of 252 Cf neutron emission rates is critical for modeling and fast-neutron experiments, yet commercial sources are often supplied without traceable calibration or uncertainty estimates. This report describes a method to characterize 252 Cf sources using a pulse-shape-discrimination (PSD) scintillator. The scintillator was efficiency-calibrated against a time-tagged 252 Cf fission chamber manufactured at ORNL over 40 years ago. Isotopic evolution of the calibration source was modeled using Bateman equations to account for changes in the effective average neutrons per fission at the time of measurement. The calibrated scintillator was then used to measure absolute emission rates of several commercial 252 Cf sources, revealing deviations of up to 12% from nominal manufacturer values. This methodology provides a practical approach for establishing uncertainty-quantified 252 Cf neutron emission rates, improving fidelity in simulations and supporting the accurate interpretation of measurements.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Multiple Coulomb scattering in acrylic of a 221.3 MeV therapeutic proton beam

Measurements of multiple Coulomb scattering (MCS) distributions for 221.3 MeV therapeutic protons are presented using a novel detector system comprised of a thin scintillator, a pellicle mirror, and a digital camera. The MCS distributions were characterized for three acrylic phantoms of varying lengths and for two biological density-equivalent phantoms simulating bone and muscle. Additionally, beam profiles were measured across an energy range of 80.3–221.3 MeV in 20 MeV increments. The observed energy dependence of the photon yields is consistent with the tabulated stopping power values. Finally, the experimental results are benchmarked against Geant4 simulations, demonstrating consistent agreement and validating the capability of the detector system for radiology measurements.

Digital camera↗