Search NASA⌕ Search

SEARCH · Search NASA

Results for “Semiconductor Detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Monolayer Semiconductor Auger Detector

Auger recombination in semiconductors is a many-body phenomenon in which the recombination of electrons and holes is accompanied by excitation of other charge carriers. The excess energy of the excited carriers is normally rapidly converted to heat, making Auger processes difficult to probe directly. In this paper, we employ a technique in which the Auger-excited carriers are detected by their ability to tunnel out of the semiconductor through a thin barrier, generating a current. We use vertical van der Waals heterostructures with monolayer WSe 2 as the semiconductor, with hexagonal boron nitride as the tunnel barrier, and a graphite collector electrode. The Auger processes combined with resonant absorption produce characteristic negative photoconductance. We detect holes Auger-excited by both neutral and charged excitons and find that the Auger scattering is surprisingly strong under weak excitation. Our work expands the range of techniques available for probing relaxation processes in 2D materials.

47 OTHER INSTRUMENTATION↗

Monte Carlo simulation for the electron cascade due to gamma rays in semiconductor radiation detectors

A Monte Carlo code was developed for simulating the electron cascade in radiation detector materials. The electron differential scattering cross sections were derived from measured electron energy-loss and optical spectra, making the method applicable for a wide range of materials. The detector resolution in a simplified model system shows dependence on the bandgap, the plasmon strength and energy, and the valence band width. In principle, these parameters could be optimized to improve detector performance. The intrinsic energy resolution was calculated for three semiconductors: silicon (Si), gallium arsenide (GaAs), and zinc telluride (ZnTe). Setting the ionization thresholds for electrons and holes is identified as a critical issue, as this strongly affects both the average electron-hole pair energy w and the Fano factor F. Using an ionization threshold from impact ionization calculations as an effective bandgap yields pair energies that are well matched to measured values. Fano factors of 0.091 (Si), 0.100 (GaAs), and 0.075 (ZnTe) were calculated. The Fano factor calculated for silicon using this model was lower than some results from past simulations and experiments. This difference could be attributed to problems in simulating inter-band transitions and the scattering of low-energy electrons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hybrid anode for semiconductor radiation detectors

The present invention relates to a novel hybrid anode configuration for a radiation detector that effectively reduces the edge effect of surface defects on the internal electric field in compound semiconductor detectors by focusing the internal electric field of the detector and redirecting drifting carriers away from the side surfaces of the semiconductor toward the collection electrode(s).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Layered semiconductor neutron detectors

Room temperature operating solid state hand held neutron detectors integrate one or more relatively thin layers of a high neutron interaction cross-section element or materials with semiconductor detectors. The high neutron interaction cross-section element (e.g., Gd, B or Li) or materials comprising at least one high neutron interaction cross-section element can be in the form of unstructured layers or micro- or nano-structured arrays. Such architecture provides high efficiency neutron detector devices by capturing substantially more carriers produced from high energy .alpha.-particles or .gamma.-photons generated by neutron interaction.

47 OTHER INSTRUMENTATION↗

Cesium lead bromide semiconductor radiation detectors: crystal growth, detector performance and polarization

Cesium lead bromide (CsPbBr 3 ) is an upcoming semiconductor radiation detector that has the potential to match the detection properties of cadmium zinc telluride (CZT) and thallium bromide (TlBr). In this paper, we report on CsPbBr 3 gamma detectors with an uncorrected energy resolution of 2% at 662 keV with photopeak-to-Compton ratios as high as 14.3 and hole mobility-lifetime products (μτ h ) as high as 1.7 × 10 –2 cm 2 V –1 . Furthermore, we demonstrate that the processes employed for material purification and crystal growth of high-performing devices are scalable, and large (up to 65 mm in diameter) ultrahigh purity CsPbBr 3 crystals have been successfully grown. Furthermore by using optimized growth conditions and detector fabrication processes, we were able to mitigate the polarization problem where it was revealed that the polarization process is highly dependent on the crystal quality and the electric field direction with respect to the orientation of the crystal.

30 DIRECT ENERGY CONVERSION↗

Non-streaming high-efficiency perforated semiconductor neutron detectors, methods of making same and measuring wand and detector modules utilizing same

Non-streaming high-efficiency perforated semiconductor neutron detectors, method of making same and measuring wands and detector modules utilizing same are disclosed. The detectors have improved mechanical structure, flattened angular detector responses, and reduced leakage current. A plurality of such detectors can be assembled into imaging arrays, and can be used for neutron radiography, remote neutron sensing, cold neutron imaging, SNM monitoring, and various other applications.

McGregor, Douglas S↗

Experimental characterisation of charged particle beams accelerated by irradiating thin targets of different materials with ultrashort laser pulses

We present the results of experimental investigation of ion and electron fluxes produced by irradiating thin foils with laser USPs. These experiments were carried out on the Sokol-P laser facility (pulse duration {approx}1 ps, power {approx}20 TW) using lavsan, aluminium, and copper targets of equal thickness ({approx}5 {mu}m). Ions were recorded employing Thomson spectrometers and a time-of-flight spectrometer with a silicon semiconductor detector. To record electrons, use was made of electron spectrometers involving the rotation of particle trajectories by 180{sup 0} in magnetic field. The ionic composition of the charged particle beam was determined and the beam shape was investigated in relation to the target material. (effects of laser radiation on matter)

36 MATERIALS SCIENCE↗

Microradiography with Semiconductor Pixel Detectors

High resolution radiography (with X-rays, neutrons, heavy charged particles, ...) often exploited also in tomographic mode to provide 3D images stands as a powerful imaging technique for instant and nondestructive visualization of fine internal structure of objects. Novel types of semiconductor single particle counting pixel detectors offer many advantages for radiation imaging: high detection efficiency, energy discrimination or direct energy measurement, noiseless digital integration (counting), high frame rate and virtually unlimited dynamic range. This article shows the application and potential of pixel detectors (such as Medipix2 or TimePix) in different fields of radiation imaging.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nuclear-recoil energy scale in CDMS II silicon dark-matter detectors

The Cryogenic Dark Matter Search (CDMS II) experiment aims to detect dark matter particles that elastically scatter from nuclei in semiconductor detectors. The resulting nuclear-recoil energy depositions are detected by ionization and phonon sensors. Neutrons produce a similar spectrum of low-energy nuclear recoils in such detectors, while most other backgrounds produce electron recoils. The absolute energy scale for nuclear recoils is necessary to interpret results correctly. The energy scale can be determined in CDMS II silicon detectors using neutrons incident from a broad-spectrum 252Cf source, taking advantage of a prominent resonance in the neutron elastic scattering cross section of silicon at a recoil (neutron) energy near 20 (182) keV. Results indicate that the phonon collection efficiency for nuclear recoils is 4.8+0.7-0.9% lower than for electron recoils of the same energy. Comparisons of the ionization signals for nuclear recoils to those measured previously by other groups at higher electric fields indicate that the ionization collection efficiency for CDMS II silicon detectors operated at ~4 V/cm is consistent with 100% for nuclear recoils below 20 keV and gradually decreases for larger energies to ~75% at 100 keV. The impact of these measurements on previously published CDMS II silicon results is small.

dark matter, detector calibration, ionization yiel↗

High-resolution Compton spectroscopy using x-ray microcalorimeters

X-ray Compton spectroscopy is one of the few direct probes of the electron momentum distribution of bulk materials in ambient and operando environments. Herein, we report high-resolution inelastic x-ray scattering experiments with high momentum and energy transfer performed at a storage-ring-based high-energy x-ray light source facility using an x-ray transition-edge sensor (TES) microcalorimeter detector. The performance was compared with a silicon drift detector (SDD), an energy-resolving semiconductor detector, and Compton profiles were measured for lithium and cobalt oxide powders relevant to lithium-ion battery research. Spectroscopic analysis of the measured Compton profiles demonstrates the high-sensitivity to the low- Z elements and oxidation states. The line shape analysis of the measured Compton profiles in comparison with computed Hartree–Fock profiles is usually limited by the resolution of the semiconductor detector. We have characterized an x-ray TES microcalorimeter detector for high-resolution Compton scattering experiments using a bending magnet source at the Advanced Photon Source with a double crystal monochromator, providing monochromatic photon energies near 27.5 keV. The momentum resolution below 0.16 atomic units (a.u.) was measured, yielding an improvement of more than a factor of 7 over a state-of-the-art SDD for the same scattering geometry. Furthermore, the lineshapes of narrow valence and broad core electron profiles of sealed lithium metal were clearly resolved using an x-ray TES compared to smeared and broadened lineshapes observed when using the SDD. High-resolution Compton scattering using the energy-resolving area detector shown here presents new opportunities for spatial imaging of electron momentum distributions for a wide class of materials with applications ranging from electrochemistry to condensed matter physics.

47 OTHER INSTRUMENTATION↗

Semiconductor neutron detectors using depleted uranium oxide

This paper reports on recent attempts to develop and test a new type of solid-state neutron detector fabricated from uranium compounds. It has been known for many years that uranium oxide (UO2), triuranium octoxide (U3O8) and other uranium compounds exhibit semiconducting characteristics with a broad range of electrical properties. We seek to exploit these characteristics to make a direct-conversion semiconductor neutron detector. In such a device a neutron interacts with a uranium nucleus, inducing ssion. The ssion products deposit energy-producing, detectable electron-hole pairs. The high energy released in the ssion reaction indicates that noise discrimination in such a device has the potential to be excellent. Schottky devices were fabricated using a chemical deposition coating technique to deposit UO2 layers a few microns thick on a sapphire substrate. Schottky devices have also been made using a single crystal from UO2 samples approximately 500 microns thick. Neutron sensitivity simulations have been performed using GEANT4. Neutron sensitivity for the Schottky devices was tested experimentally using a 252Cf source.

neutron detection, uranium oxide, semiconductor↗

Measurement of the mass attenuation coefficient from 81 keV to 1333 keV for elemental materials Al, Cu and Pb

The mass attenuation coefficients (μ/ρ) for 3 high purity elemental materials Al, Cu and Pb were measured in the γ-ray energy range from 81 keV up to 1333 keV using {sup 22}Na, {sup 60}Co {sup 133}Ba and {sup 133}Cs as sources of gamma radiation. Well shielded detector (NaI (Tl) semiconductor detector) was used to measure the intensity of the transmitted beam. The measurements were made under condition of good geometry, assuring that any photon absorbed or deflected appreciably does not reach the detector. The measured values are compared with the theoretical ones obtained by Seltzer (1993).

07 ISOTOPE AND RADIATION SOURCES↗

Development of a System for Measuring the Shape of β Spectra Using a Semiconductor Si Detector

A system for the measurement of beta energy spectra has been developed. It is based on a silicon semi-conductor detector operating at liquid nitrogen temperatures, under ultra high-vacuum. Monte-Carlo simulations were made to optimize the detection chamber and the source holder. Descriptions of the electronic and mechanical systems are included, as well as the first measured spectra.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Hard x-ray phase contrast imaging using single absorption grating and hybrid semiconductor pixel detector

A method for x-ray phase contrast imaging is introduced in which only one absorption grating and a microfocus x-ray source in a tabletop setup are used. The method is based on precise subpixel position determination of the x-ray pattern projected by the grating directly from the pattern image. For retrieval of the phase gradient and absorption image (both images obtained from one exposure), it is necessary to measure only one projection of the investigated object. Thus, our method is greatly simplified compared with the phase-stepping method and our method can significantly reduce the time-consuming scanning and possibly the unnecessary dose. Furthermore, the technique works with a fully polychromatic spectrum and gives ample variability in object magnification. Consequently, the approach can open the way to further widespread application of phase contrast imaging, e.g., into clinical practice. The experimental results on a simple testing object as well as on complex biological samples are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Soft X-Ray Spectrometer Using 100-Pixel STJ Detectors for Synchrotron Radiation

Fluorescent X-ray absorption fine structure (XAFS) is an important tool for material analysis, especially for the measurement of chemical states or local structures of elements. Semiconductor detectors are usually used for separating the fluorescent of elements in question from background fluorescence. However, the semiconductor detectors cannot always discriminate K-lines of light elements and L-lines of various elements as different X-ray peaks at an energy range below about 3 keV. Superconducting tunnel junction (STJ) detectors are promising device for the soft X-ray at synchrotron radiation beam lines because of excellent energy resolution, high detection efficiency, and high counting rate. We are constructing a fluorescent X-ray spectrometer having 100-pixel array of STJs with 200 {mu}m square. The array detector is mounted on a liquid cryogen-free {sup 3}He cryostat. The sensitive area is the largest among the superconducting X-ray spectrometers operating at synchrotron beam lines. Each pixel is connected to a room temperature readout circuit that consists of a charge sensitive amplifier and a pulse height analyzer. The spectrometer will achieve a total solid angle of {approx}0.01 sr and a maximum counting rate of more than 1 M count per second. The present status of developments of our fluorescent X-ray spectrometer was reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗