Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sensitive”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

New tree-ring data from Canadian boreal and hemi-boreal forests provide insight for improving the climate sensitivity of terrestrial biosphere models

Understanding boreal/hemi-boreal forest growth sensitivity to seasonal variations in temperature and water availability provides important basis for projecting the potential impacts of climate change on the productivity of these ecosystems. Our best available information currently comes from a limited number of field experiments and terrestrial biosphere model (TBM) simulations of varying predictive accuracy. Here, we assessed the sensitivity of annual boreal/hemi-boreal forest growth in Canada to yearly fluctuations in seasonal climate variables using a large tree-ring dataset and compared this to the climate sensitivity of annual net primary productivity (NPP) estimates obtained from fourteen TBMs. We found that boreal/hemi-boreal forest growth sensitivity to fluctuations in seasonal temperature and precipitation variables changed along a southwestern to northeastern gradient, with growth limited almost entirely by temperature in the northeast and west and by water availability in the southwest. We also found a lag in growth climate sensitivity, with growth largely determined by the climate during the summer prior to ring formation. Analyses of NPP sensitivity to the same climate variables produced a similar southwest to northeast gradient in growth climate sensitivity for NPP estimates from all but three TBMs. However, analyses of growth from tree-ring data and analyses of NPP from TBMs produced contrasting evidence concerning the key climate variables limiting growth. While analyses of NPP primarily indicated a positive relationship between growth and seasonal temperature, tree-ring analyses indicated negative growth relationships to temperature. Also, the positive effect of precipitation on NPP derived from most TBMs was weaker than the positive effect of precipitation on tree-ring based growth: temperature had a more important limiting effect on NPP than tree-ring data indicated. These mismatches regarding the key climate variables limiting growth suggested that characterization of tree growth in TBMs might need revision, particularly regarding the effects of stomatal conductance and carbohydrate reserve dynamics.

54 ENVIRONMENTAL SCIENCES↗

Enhancing Sensitivity in Targeted Single-Cell Proteomics by Coupling a Dual Ion Funnel Interface with Triple Quadrupole Mass Spectrometer

Single-cell proteomics (SCP) has emerged as a powerful approach for understanding cellular heterogeneity and biological processes at unprecedented resolution. However, the extremely limited protein content of individual cells (femtogram to picogram levels) pushes current mass spectrometry instrumentation to its sensitivity limits, creating a critical analytical bottleneck. While selected reaction monitoring (SRM) using triple quadrupole (QqQ) instruments 1 offers advantages in sensitivity and reproducibility for targeted proteomics quantification, SRM still struggles with sensitivity for quantification of moderate- or low-abundance proteins from single-cell sample amounts. Here, we report the development and systematic evaluation of a dual ion funnel interface designed to address the sensitivity limitation by significantly enhancing ion transmission efficiency in commercial QqQ mass spectrometers. The dual ion funnel interface, composed of a curved S-funnel followed by a conventional ion funnel, improves ion transmission efficiency while reducing chemical noise through selective ion focusing. The performance of the dual ion funnel interface was systematically compared to standard interface on a TSQ Vantage platform across samples with different levels of complexity. The dual funnel interface demonstrated to provide up to 25-fold improvement in sensitivity across a wide range of protein concentrations in different biological matrices (low complex mouse macrophage and high complex human cells). Critically, enhanced sensitivity was accompanied by increased analytical reproducibility with lower coefficient of variations. Most importantly, the dual funnel interface enabled reliable quantification of low-abundance proteins that were barely detectable or not detected by the standard interface, extending analysis to single-cell equivalent amounts while maintaining excellent reproducibility. These results demonstrate that the dual funnel interface addresses the critical bottleneck in quantitative targeted proteomics, providing a technological foundation for ultrasensitive targeted SCP that requires both high sensitivity and robust quantitative performance.

Min, Sehong↗

Coupling Warm Rain With an Eddy Diffusivity/Mass Flux Parameterization: 2. Sensitivities and Comparison to Observations

Abstract This is the second part of the description and validation of the coupling of a warm‐rain microphysics scheme to a stochastic multi‐plume eddy‐diffusivity/mass‐flux parameterization. Part 1 provides the model description and initial validation of the parameterization in a single column model (SCM) against large eddy simulations. This manuscript provides additional comparisons against satellite observations of 500 unique simulation cases, an analysis of model parameter‐based sensitivities in those 500 cases, and an evaluation of the idealized LES case study paradigm for parameterization development. The SCM is forced by a weather reanalysis in the subtropical northeast Pacific region characterized by the stratocumulus‐to‐cumulus cloud transition. 18 scalar outputs are examined to identify the sensitivities to 22 of the model's parameters. The model is highly sensitive to parameters that determine the behavior of convective plumes, which collectively lead to the most sensitivity in 13 of the 18 outputs. Only a few parameters contribute sensitivities that are not highly correlated with those of other parameters. While forcing the model with two canonical field campaign cases results in similar picture of which parameters lead to high sensitivity in model outputs, the sensitivity magnitudes can be overestimated compared to when the model is forced by weather reanalyzes.

54 ENVIRONMENTAL SCIENCES↗

A single TRPV1 amino acid controls species sensitivity to capsaicin

Chili peppers produce capsaicin (a vanilloid) that activates the transient receptor potential cation channel subfamily V member 1 (TRPV1) on sensory neurons to alter their membrane potential and induce pain. To identify residues responsible for differential TRPV1 capsaicin sensitivity among species, we used intracellular Ca 2+ imaging to characterize chimeras composed of capsaicin-sensitive rat TRPV1 (rTRPV1) and capsaicin-insensitive chicken TRPV1 (cTRPV1) exposed to a series of capsaicinoids. We found that chimeras containing rat E570-V686 swapped into chicken receptors displayed capsaicin sensitivity, and that simply changing the alanine at position 578 in the S4-S5 helix of the chicken receptor to a glutamic acid was sufficient to endow it with capsaicin sensitivity in the micromolar range. Moreover, introduction of lysine, glutamine or proline at residue A578 also elicited capsaicin sensitivity in cTRPV1. Similarly, replacing corresponding rTRPV1 residue E570 with lysine or glutamine retained capsaicin sensitivity. The hydrophilic capsaicin analog Cap-EA activated a cTRPV1-A578E mutant, suggesting that A578 may participate in vanilloid binding. The hydrophilic vanilloid agonist zingerone did not activate any A578 mutants with capsaicin sensitivity, suggesting that the vanilloid group alone is not sufficient for receptor activation. Our study demonstrates that a subtle modification of TRPV1 in different species globally alters capsaicin responses.

59 BASIC BIOLOGICAL SCIENCES↗

Systematic evaluation of magnetic sensitivities of anisotropic magnetoresistive sensors at liquid helium temperature for superconducting cavities

Trapped magnetic flux in bulk superconductors reduces the quality factor Q in superconducting radio-frequency (SRF) cavities. However, the mechanisms underlying flux trapping and radio-frequency loss are not well understood. Detailed observation of the magnetic distributions is important for understanding such phenomena. Magnetic field mapping is useful for observing the magnetic field distribution around SRF cavities. Measuring the change in the magnetic field around the cavity elucidates the flux trapping behavior. Anisotropic magnetoresistive (AMR) sensors are inexpensive and small devices that can detect magnetic flux density. The magnetic sensitivities of AMR sensors need to be evaluated at liquid helium temperature for the magnetic field mapping of SRF cavities. In this study, a test stand was constructed to calibrate the magnetic sensitivities of AMR sensors in liquid helium, and 110 AMR sensors were tested using this stand. The magnetic sensitivities were evaluated systematically. A solenoid coil was used to control the uniform external magnetic field and to measure the magnetic sensitivity at low temperatures. All AMR sensors exhibited suitable sensitivities to the magnetic field around the SRF cavity. The variation in these sensitivities in all AMR sensors was ~1%. Further, the AMR sensors were found to have sufficient sensitivity for mapping the magnetic field around the exterior surface of the SRF cavity.

43 PARTICLE ACCELERATORS↗

Sensitivity measurements for a 250 MHz quartz shear-horizontal surface acoustic wave biosensor under liquid viscous loading

Surface acoustic wave (SAW) devices have been used in biochemical assays due to their high sensitivity. The device sensitivity is a function of changes in the density and viscosity of the liquid. Here, we studied the effect of fluid viscosity using a 250 MHz quartz shear-horizontal (SH)-SAW biosensor by monitoring different concentrations of binary aqueous/glycerol solutions. In this study, the sensitivity of the biosensor was determined by fitting the data to models derived from perturbation theory. Measurements in water were used as the reference. For a 0% to 50% glycerol solution, an 87°–204° separation in the phase shift was observed. The slope of the plot of the phase shift vs (ηρ)0.5 was used to indicate the sensor’s sensitivity. The sensitivity for our 250 MHz quartz SH-SAW sensors was calculated to be 3.7×10−3m2sKg. The corresponding mass sensitivity was determined to be 9.25 × 105m2Kg. The limit of detection was calculated to be 36 picograms (pg), while the limit of quantification or LOQ was calculated to be 109 pg. Traditionally, liquid phase measurements have been challenging for SAW devices because liquids dampen the vibrating sensors severely. This problem has been largely solved using a transverse (shear) wave instead of the more popular longitudinal or Rayleigh waves. Liquid measurements are now possible using transverse waves, also known as shear waves, because transverse waves are only minimally attenuated by liquids. Shear-horizontal SAW sensors (SH-SAW) show great promise as label-free biosensors because of their ability to handle liquid samples. However, the viscosity of the liquid still induces loading effects and can be measured when the liquid is loaded onto the SH-SAW propagating surface (delay line). When the liquid above the delay line is perturbed by physical or chemical changes, such as binding to a receptor, it alters the propagating acoustic wave. The SH-SAW device can measure these changes in liquid properties as a change in the wave’s phase compared to the original wave. The device’s phase shift was recorded as a function of the changes in the density and viscosity of the binary glycerol solution and used to determine the sensitivity in the linear dynamic range of responses.

Materials Science↗

Generalized echo squeezing protocol with near-Heisenberg-limit sensitivity and strong robustness against detection noise and variation in squeezing parameter

We present a generalized echo squeezing protocol (GESP) as a generalization of the Schrödinger cat state protocol with the value of the squeezing parameter being an arbitrary number rather than π / 2 . We show analytically that over a very broad range of the squeezing parameter the sensitivity of the GESP reaches the Heisenberg limit within a factor of 2 . For a large number of atoms, N , this plateau interval is almost the whole range from zero to π / 2 , and the sensitivity is independent of the parity of N . Therefore, it is possible to operate a sensor over a wide interval of the squeezing parameter without changing the sensitivity. This is to be contrasted with the conventional echo squeezing protocol (CESP) which only works for a very small interval of the squeezing parameter. We also show that, in contrast to the CESP, the sensitivity of the GESP is close to the quantum Cramér-Rao bound over the whole range of the squeezing parameter, indicating that the phase-shift information contained in the quantum state is near-optimally extracted. We find that the enhancement in sensitivity in the case of the GESP is due to a combination of two parameters: the phase magnification factor (PMF) and the noise amplification factor (NAF). As the value of the squeezing parameter increases, both PMF and NAF increase, while keeping the ratio of the PMF to the NAF essentially constant, yielding a net enhancement of sensitivity at the Heisenberg limit within a factor of 2 over the whole plateau interval. An important consequence of this behavior is that the robustness of the GESP against detection noise easily exceeds that of the CESP for a broad range of values of the squeezing parameter. As such, in the context of an experimental study, it should be possible to achieve a net enhancement in sensitivity higher than that for the CESP, under typical conditions where detection noise exceeds the quantum projection noise of an unsqueezed state with the same number of atoms. Finally, we consider the fragility of the GESP against decoherence mechanisms, and show how a balance between the fragility against the decoherence mechanisms and the robustness against detection noise would in practice determine the optimal choice of parameters for the GESP.

Li, Jinyang↗

Computation of Direct Sensitivities of Spatial Multibody Systems With Joint Friction

Abstract Friction exists in most mechanical systems and may have a major influence on the dynamic performance of the system. The incorporation of friction in dynamic systems has been a subject of active research for several years owing to its high nonlinearity and its dependence on several parameters. Consequently, optimization of dynamic systems with friction becomes a challenging task. Gradient-based optimization of dynamical systems is a prominent technique for optimal design and requires the computation of model sensitivities with respect to the design parameters. The novel contribution of this paper is the derivation of the analytical methodology for the computation of direct sensitivities for smooth multibody systems with joint friction using the Lagrangian index-1 formulation. System dynamics have been computed using two different friction models; the Brown and McPhee, and the Gonthier et al. model. The methodology proposed to obtain model sensitivities has also been validated using the complex finite difference method. A case study has been conducted on a spatial multibody system to observe the effect of friction on the dynamics and model sensitivities, compare sensitivities with respect to different parameters and demonstrate the numerical and validation aspects. Since design parameters can have very different magnitudes and units, the sensitivities have been scaled with the parameters for comparison. Finally, a discussion has been presented on the interpretation of the case study results. Due to the incorporation of joint friction, ‘jumps’ or discontinuities are observed in the model sensitivities akin to those observed for hybrid dynamical systems.

Engineering↗

Sensitivity Analysis and Effective Parametrization of PEM Fuel Cell Models

The cost of proton-exchange-membrane fuel cells (PEMFCs) remains a major hurdle in large-scale commercialization of this technology. To improve their performance and reduce cost, novel materials and electrode designs are continuously envisioned, e.g., non-PGM catalyst layers, ultra-thin Pt/Pt-Ni based catalyst layers, structured ionomer arrays or NSTF catalyst layers.1 Understanding the impact of these improvement strategies can be extremely time and cost intensive due to complex physical phenomena and large design space. We have previously developed a PEMFC modeling framework2 which has been a time and cost effective tool for understanding and optimizing the complex multi-physics phenomena within PEMFCs; however, several of the cell parameters used in the modeling have large spread in measured data.3 Furthermore, several transport parameters such as water adsorption kinetics have not been accurately measured and the approximations are spread over several orders of magnitude. These uncertainties cause problems in ascertaining accuracy of the modeling approach and they reduce the predictive power of the numerical models. The aim of this work is to identify the sensitivity of PEFC numerical model outputs to various input parameters. The previously in-house developed MEA modeling framework2 is used for PEMFC modeling. The sensitivity of the model outputs with respect to inputs parameters is obtained by analyzing the condition numbers for different output-input pairs at varying operating conditions. An example of the sensitivity analysis is shown in Figure 1. The condition numbers are obtained for the entire possible range of input parameters at varying operating conditions to identify the most crucial parameters of the PEMFC model. Based on our preliminary analysis, parameters related to kinetics (exchange current density and ECSA) and heat/water management in electrodes and ionomer (ionomer fraction, thermal conductivity) are most crucial. One of the major goals of this work is to identify the most crucial set of parameters towards which the model shows maximum sensitivity. This will guide future experimentalists to measure these properties with higher accuracy. Furthermore, the sensitivity analysis will also enable us to optimize the PEMFC performance by selectively targeting the most sensitive parameters and thereby making the largest impact. Acknowledgements The work is funded under the Fuel Cell Performance and Durability Consortium (FC-PAD), by the Fuel Cell Technologies Office (FCTO), Office of Energy Efficiency and Renewable Energy (EERE), of the U.S. Department of Energy under contract number DE-AC02-05CH11231. The authors would like to thank Nathan Craig at Robert Bosch LLC for his valuable input in designing the sensitivity analysis. The authors would also like to thank Giovanna Bucci and Matthias Hanauer at Robert Bosch for their valuable inputs and discussion. References P. K. Sinha, W. Gu, A. Kongkanand and E. Thompson, J. Electrochem. Soc., 158, B831 (2011). L. M. Pant, M. R. Gerhardt, N. Macauley, R. Mukundan, R. L. Borup and A. Z. Weber, Electrochim. Acta, 326, 134963 (2019). R. Vetter and J. O. Schumacher, ArXiv181110091 Phys. (2018). Figure 1

Pant, Lalit↗

Too Good to Be True? Evaluation of Colonoscopy Sensitivity Assumptions Used in Policy Models

Background: Models can help guide colorectal cancer screening policy. Although models are carefully calibrated and validated, there is less scrutiny of assumptions about test performance. Methods: We examined the validity of the CRC-SPIN model and colonoscopy sensitivity assumptions. Standard sensitivity assumptions, consistent with published decision analyses, assume sensitivity equal to 0.75 for diminutive adenomas (<6 mm), 0.85 for small adenomas (6–10 mm), 0.95 for large adenomas (≥10 mm), and 0.95 for preclinical cancer. We also selected adenoma sensitivity that resulted in more accurate predictions. Targets were drawn from the Wheat Bran Fiber study. In the study, we examined how well the model predicted outcomes measured over a three-year follow-up period, including the number of adenomas detected, the size of the largest adenoma detected, and incident colorectal cancer. Results: Using standard sensitivity assumptions, the model predicted adenoma prevalence that was too low (42.5% versus 48.9% observed, with 95% confidence interval 45.3%–50.7%) and detection of too few large adenomas (5.1% versus 14.% observed, with 95% confidence interval 11.8%–17.4%). Predictions were close to targets when we set sensitivities to 0.20 for diminutive adenomas, 0.60 for small adenomas, 0.80 for 10- to 20-mm adenomas, and 0.98 for adenomas 20 mm and larger. Conclusions: Colonoscopy may be less accurate than currently assumed, especially for diminutive adenomas. Alternatively, the CRC-SPIN model may not accurately simulate onset and progression of adenomas in higher-risk populations. Impact: Misspecification of either colonoscopy sensitivity or disease progression in high-risk populations may affect the predicted effectiveness of colorectal cancer screening. When possible, decision analyses used to inform policy should address these uncertainties.

60 APPLIED LIFE SCIENCES↗

A Review and Comparison of Different Sensitivity Analysis Techniques in Practice

There exist many methods for sensitivity analysis readily available to the practitioner. While each seeks to help the modeler answer the same general question – How do sources of uncertainty or changes in the model inputs relate to uncertainty in the output? – different methods are associated with different assumptions, constraints, and required resources, leading to conclusions that may vary in interpretability and level of detail. Thus, it is crucial that the practitioner selects the desired sensitivity analysis method judiciously, making sure to match the selected approach to the specifics of their problem and to their desired objectives. In this chapter, we provide a practical overview of a collection of widely used, widely available sensitivity analysis methods. We focus on global sensitivity approaches, which seek to characterize how uncertainty in the model output may be allocated to sources of uncertainty in model inputs across the entire input space. Generally, this will require the practitioner to specify a probability distribution over the input space. On the other hand, methods for local sensitivity analysis do not require this specification but they have more limited utility, providing insight into sources of uncertainty associated only with a particular, specified location in the input space. Our hope is that this chapter may serve as a decision-making tool for practitioners, helping to guide the selection of a sensitivity analysis approach that will best fit their needs. To support this goal, we have selected a suite of approaches to cover, which, while not exhaustive, we believe provides a flexible and robust sensitivity analysis toolkit. All methods included are widely used and available in standard software packages.

97 MATHEMATICS AND COMPUTING↗

VARI3D & PERSENT: Perturbation and Sensitivity Analysis

The nodal diffusion method is one of the most widely used approaches in modern reactor analysis. In the nodal diffusion method, a coarse multi-group set of “homogenized” parameters is constructed such that the complex geometry of a reactor core along with the energy dependence of neutron and gamma ray cross sections in a nuclear reactor are conserved in the simpler geometry. The homogenization is typically done on a fuel assembly level as is the case in the DIF3D code developed at Argonne National Laboratory. The nodal methodology is used primarily to predict fuel cycle behavior of nuclear systems of which there is a substantial amount of validation in the literature. Another use of the nodal method is to obtain reactivity coefficients and kinetics parameters for use in a safety analysis of a given nuclear reactor. While there are many ways to obtain reactivity worth and kinetics parameters, the work presented in this manuscript is unique as it provides the user with the ability to compute reactivity worths, kinetics parameters, and cross section sensitivities with a Cartesian and hexagonal geometry based transport code. This manuscript serves as a single manual for two separate codes: VARI3D and PERSENT. The VARI3D code (VARIational 3D) is based upon the classic finite difference diffusion theory solver available in DIF3D. The PERSENT code (PERturbation and SENitivity for Transport) is based upon the variational nodal method employed in DIF3D termed VARIANT. The VARIANT solver was added to DIF3D in 1995 and has seen continued development and use for the last 18 years. Because VARI3D primarily uses deprecated coding practices, rather than incorporating the perturbation and sensitivity treatments for transport within VARI3D, a new coding development was built using modern Fortran coding. The primary purpose of this manual is to describe the theory behind PERSENT (and by convenience, that of VARI3D) and discuss the input and output of PERSENT along with giving potential users an idea of how to use it. While this manuscript does describe the input and output of VARI3D, the PERSENT code is intended to be the replacement capability of VARI3D as PERSENT can generate nearly identical (if not superior) diffusion theory results. In this manuscript, the relevant aspects of generalized perturbation theory and exact perturbation theory that apply to both VARI3D and PERSENT are covered. The input and output of VARI3D is displayed by excerpting several of the example problems. Similarly, the input and output of PERSENT is displayed along with tips on how best to use the code. Note that the input and output of the inhomogeneous solver wrapped around DIF3D (DIF3D_IFS) is also discussed as it is needed to carry out some of the sensitivities in PERSENT such as reaction rate ratios. This manuscript describes several perturbation and sensitivity problems, and the results computed using PERSENT. From these sections, potential users should find that PERSENT provides not only the typical tables of numbers desired in perturbation and sensitivity analysis work, but also can visually plot the result for a more thorough understanding of the space and energy distribution (Section 5). Overall, PERSENT is observed to produce accurate reactivity worths and sensitivities for the displayed set of test problems and clearly demonstrates the need to have a transport-based sensitivity capability as evident from the thousands of percent errors observed in the 21-group hexagonal fast reactor problem (covered in Section 7). The uncertainty calculation capability is described in Section 3 and demonstrated in Section 7.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Verification of Upcoming MCNP Features For Estimating Nuclear Data Sensitivities in Fixed Source Simulations [Abstract]

Predictive simulation codes, like the Monte Carlo N-Particle (MCNP) transport code, are used throughout the nuclear community. These simulations are based on nuclear data. Maximizing the accuracy and precision of nuclear data maximizes the accuracy and precision of the overall simulation. This is imperative to applications that rely on simulations. For example, improving nuclear data for special nuclear material improves simulation accuracy in stockpile stewardship applications, which results in larger safety margins and decreased operational costs. The improvement and validation of nuclear data is completed through integral benchmark experiments. Past benchmarks have primarily been limited to focus on the effective multiplication factor ($\kappa$ eff ); broadening the purview of benchmarks beyond $\kappa$ eff -dependent nuclear data addresses nuclear data deficiencies. Different response types depend on different areas of nuclear data. This dependence is quantified as nuclear data sensitivity: the change in response due to perturbation of a contributing parameter. The larger the nuclear data sensitivity of a response, the more the experiment is influenced by the uncertainties of the nuclear data. The optimization of nuclear data sensitivities in future benchmarks would result in more detailed validation of lesser studied areas of nuclear data. Currently, direct sensitivity capabilities are not easily found for all experiment types and parameters. An MCNP tool to directly estimate the cross section sensitivities of tallied values is under development. Additionally, updates have been made to the perturbation feature of MCNP, which can be used in a less direct approach to estimating sensitivities. This work verifies these features to estimate nuclear data sensitivities in fixed source simulations of a 4.5-kg sphere of alpha- phase weapons-grade plutonium surrounded by differing amounts of copper and polyethylene. Integrated estimates made using MCNP’s tools were found to statistically agree with integrated estimates made from manual perturbation of nuclear data proving the validity of the MCNP tools.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Kinetic and temperature sensitivity properties of soil exoenzymes through the soil profile down to one-meter depth at a temperate coniferous forest (Blodgett, CA)

This dataset contains data on kinetic and temperature sensitivity parameters of the exoenzymes β-glucosidase (BG), leucine/leucyl aminopeptidase (LAP) and acid phosphatase (AP) across a soil profile down to 90 cm depth at Blodgett forest, CA, USA. These data were generated to determine if kinetic and thermal properties of microbial exoenzymes involved in organic matter decomposition varied with soil depth, following variation in soil properties and microbial communities, as part of the study: Alves et al. (2021). Kinetic Properties of Microbial Exoenzymes Vary with Soil Depth but Have Similar Temperature Sensitivities Through the Soil Profile. Frontiers in Microbiology 12:3618. https://doi.org/10.3389/fmicb.2021.735282. This research was performed within the framework of the TES Belowground Biogeochemistry SFA project, in particular association with a long-term field warming experiment of the whole soil profile at Blodgett forest. Samples for this work were collected from locations representative of the field experimental plots. Potential enzyme activity rates were measured using laboratory fluorometric assays with soils collected at 0-10, 10-20, 30-40, 50-60, 60-70 and 80-90 cm deep in biological triplicates (i.e., three soil cores collected at different representative locations). Assays with each soil were conducted over a gradient of eight substrate concentrations per enzyme, and incubated at 4, 10, 16, 25, 35 or 50°C. Enzyme Michaelis-Menten kinetics were modeled over the eight substrate concentrations at each temperature, and the temperature sensitivity of the kinetic parameters was modeled over the six temperatures using linear Arrhenius/Q10 and non-linear Macromolecular Rate Theory (MMRT) models. The dataset includes the fully processed enzyme activity rate data used to model Michaelis-Menten kinetics, calculated kinetic and temperature sensitivity parameters, and basic soil and microbial biomass chemistry for each sample. All data is provided for each individual biological replicate, and kinetic and temperature sensitivity parameters are also provided as means of the biological replicates. The dataset also includes all raw measurement data and code used to parse, combine and perform the analyses described by Alves et al. (2021). For file descriptions, see the file-level metadata files: “enzymes_dataProcessed_flmd.xlsx” (processed data); “enzymes_dataRaw_flmd.xlsx” (compressed raw data and metadata); and “enzymes_code_flmd.xlsx” (compressed code). The experimental design, list of parameters measured, soil and microbial biomass chemistry data, and means of biological replicates for kinetic and temperature sensitivity parameters are also provided as human-readable tables in file “enzymeTraits_design_results_tables.xlsx”.

54 ENVIRONMENTAL SCIENCES↗

Utilization of ACE nuclear data file toolkit ACEtk to calculate relative sensitivity coefficients of point-kinetics parameters

Sensitivity and uncertainty methods are quintessential for nuclear criticality safety and experiment design. This type of analysis relies on calculations of sensitivity coefficients; sensitivity coefficients of the effective neutron multiplication factor with respect to some nuclear data are predominantly calculated and used. As a part of the Laboratory Directed Research & Development project EUCLID (Experiments Underpinned by Computational Learning for Improvements in nuclear Data) at Los Alamos National Laboratory, sensitivity coefficients of many radiation detector measurement responses with respect to nuclear data were investigated. Specifically, this paper outlines a method to calculate point-kinetics parameters relative sensitivity coefficients with respect to nuclear data. Point-kinetics parameters such as the prompt neutron decay constant, effective delayed neutron fraction, and neutron generation time are especially important to experimenters and reactor operators designing systems with dynamic neutron populations. This method couples capabilities of the ACE (A Compact ENDF) nuclear data file toolkit, ACEtk, with the ability to load cross sections into the radiation transport code Monte Carlo N-Particle (MCNP). In conclusion, key aspects of optimizing this method for a particular application and sensitivity profiles of the Jezebel criticality experiment are examined and discussed.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Novel method to control explosive shock sensitivity: Formulations, experiments and modeling

The microstructure of a heterogeneous high explosive (HE) affects its shock initiation sensitivity and detonation performance. Alteration of the void content and/or void structure (i.e., bulk heating or mechanical damage) therefore changes the shock initiation behavior. Controlling and predicting the change in shock sensitivity after an HE has undergone microstructural changes addresses an important and challenging goal for the design and understanding of novel energetic material formulations. In this study, we aimed to develop HE systems to precisely tune shock sensitivity by a thermal treatment prior to use. Specifically, we incorporated a small fraction (1 wt% or less) of thermally expandable microspheres (TEMs) during the formulation process of various plastic-bonded explosives (PBX). TEMs typically consist of a thermoplastic acrylonitrile shell (10-50 µm diameter), which encapsulates an inert low boiling hydrocarbon. Upon heating, the TEMs expand as the shell softens while the hydrocarbon gasifies, increasing the internal pressure and expanding the particle by as much as 120 vol% (irreversibly). Here, we present our progress on shock sensitivity comparisons of HE formulations doped with TEMs after heating and expansion. Experiments, using Composition C-4 thermally cycled to 120°C, showed an increase in shock sensitivity. Additionally, mesoscale modeling revealed that the TEM itself does not act as a hotspot, but instead has a secondary effect on the response of nearby voids. We conclude that TEMs indeed do provide a method to tune shock sensitivity. Further, our results emphasize the non-uniformity of shock waves at the mesoscale, and that upstream defects influence the reactivity of downstream defects.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Synthesis and investigation into explosive sensitivity for a series of new picramide explosives

Tailoring the molecular properties that govern energetic material sensitivity is essential to improve safety and help develop new energetic materials. Despite this need, understanding the complex chemistry and physics of explosive initiation and propagation is still a challenge. Recent work by our group has reinforced the view that explosive sensitivity under sub-shock conditions is connected to the strength of the weakest covalent bond in the molecule, that is, its “trigger linkage.” These correlations have been observed with different classes of energetic molecules and indicate that “trigger linkage” bond breaking, and heat of explosion are good indicators for the sensitivity trends. Herein we report the synthesis of aliphatic energetic materials with ethane, propane and neopentane backbones. Experimental and computational studies show that the trigger linkage model, based on results from quantum molecular dynamics simulations, correctly predicts trends observed in the impact sensitivity of the molecules. However, while the model predicts the impact sensitivities of the ethane series, the neopentane series has higher impact sensitivities than predicted, which is presumably influenced by crystal packing effects.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

EUCLID Sensitivity Database

This report documents the EUCLID sensitivity database along with its several use-cases. EUCLID computed sensitivities for the following integral responses: Criticality of ICSBEP critical assemblies, LLNL pulsed-sphere neutron-leakage spectra, reaction rates in selected ICBSEP critical assemblies, delayed neutron factions of selected ICSBEP critical assemblies, reactivity coefficients in two ICSBEP critical assemblies, sub-critical assembly responses and Rossi-alpha of selected critical assemblies. It is described for each response what the reported observable constitutes, the method we used to obtain the sensitivities, and which integral experiments were studied. It is also documented briefly in what format these sensitivities are stored. These sensitivities were used for many aspects of the EUCLID project, like ML-supported large-scale nuclear-data validation, or optimization of integral experiments. But these sensitivities can also be applied for more established processes in the nuclear-data application field such as adjustment or assessing the upper sub-critical limit.

Delayed Neutron Fraction↗