Search NASASearch

SEARCH · Search NASA

Results for “Sensitivity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Resurrecting Hitomi for Decaying Dark Matter and Forecasting Leading Sensitivity for XRISM

The Hitomi x-ray satellite mission carried unique high-resolution spectrometers that were set to revolutionize the search for sterile neutrino dark matter (DM) by looking for narrow x-ray lines arising from DM decays. Unfortunately, the satellite was lost shortly after launch, and to date the only analysis using Hitomi for DM decay used data taken towards the Perseus cluster. Here, in this work we present a significantly more sensitive search from an analysis of archival Hitomi data towards blank sky locations, searching for DM decaying in our own Milky Way. The recently launched XRISM satellite has nearly identical soft-x-ray spectral capabilities to Hitomi; we project the full-mission sensitivity of XRISM for analyses of their future blank-sky data, and we find that XRISM will have the leading sensitivity to decaying DM for masses between roughly 1 to 18 keV, with important implications for sterile neutrino and heavy axionlike particle DM scenarios.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS

Sensitivity of the CUPID experiment to $0\nu \beta \beta$ decay of 100 Mo

CUPID is a next-generation bolometric experiment to search for neutrinoless double-beta decay ($0\nu \beta \beta$ ) of 100 Mo using Li 2 MoO 4 scintillating crystals. It will operate 1596 crystals at ~10 mK in the CUORE cryostat at the Laboratori Nazionali del Gran Sasso in Italy. Each crystal will be facing two Ge-based bolometric light detectors for α rejection. We compute the discovery and the exclusion sensitivity of CUPID to $0\nu \beta \beta$ in a Frequentist and a Bayesian framework. This computation is done numerically based on pseudo-experiments. For the CUPID baseline scenario, with a background and an energy resolution of 1.0 x 10 –4 counts/keV/kg/yr and 5 keV FWHM at the Q-value, respectively, this results in a Bayesian exclusion sensitivity (90% c.i.) of $\hat{T}_{1/2} > 1.6 \times 10^{27} \ \textrm{yr}$, corresponding to the effective Majorana neutrino mass of $\hat{m}_{\beta \beta } < \ 9.6$ – 28 meV. The Frequentist discovery sensitivity (3σ ) is $\hat{T}_{1/2}= 1.0 \times 10^{27} \ \textrm{yr}$, corresponding to $\hat{m}_{\beta \beta }= \ 12$ – 36 meV.

Alfonso, K. [Virginia Polytechnic Institute and St

Impact of Increased Monte Carlo Parameters on Sensitivity Calculations with SCALE [Slides]

For both models and tests, NPG and NSK parameters have only small effects on calculated sensitivity coefficients. Outside of NPG=100, only differences in CFP affected sensitivity coefficient values. Fission reactions ( 235 U) require more NPG values than scattering ( 238 U) reactions – more particles are needed to locate fission sources in the model more accurately. This work confirms the previous results with the IFP method where the CFP parameter has the greatest impact on calculated sensitivity coefficients. While immediate work focuses on fast systems, other model specifications may require a different set of MC parameters.

97 MATHEMATICS AND COMPUTING

Comparison of the sensitivity of 236 U measurements in environmental samples by MC-ICP-MS and ATONA based high precision U TIMS measurements

The ATONA project is focused upon exploring the improvements in uranium isotope ratio measurements by thermal ionization mass spectrometry (TIMS) provided by a new, capacitor-based, amplifier technology. These “ATONA” Faraday amplifiers (Isotopx Ltd, UK) promise accurate, low-noise measurements of very small signals (< 1 femto-amp) in a traditional Faraday cup, which was only previously possible using an ion counter. This report outlines a series of experiments that were performed to assess the performance of the system in samples that test our rapid analysis procedures, and then compare the results against other mass spectrometry techniques currently available for environmental analyses. The following major goals were achieved: (1) illustrated the importance of 236 U measurements for the screening and analysis of environmental samples; (2) improved sensitivity for 236 U, and then identified 236 U in the 4350B standard at ultra-trace levels (3) Provided comparison of the 236 U sensitivity to multi-collector inductively coupled mass spectrometry techniques (4) Illustrated high TRL for the ATONA based measurement technique. This completes the reporting requirements for task 4 in the project LCP and highlights the utility of the system to make highly sensitive 236 U measurements in programmatically relevant sample matrices and at relevant uranium concentrations.

07 ISOTOPE AND RADIATION SOURCES

Uncertainty and Sensitivity Analysis Methods and Applications in the GDSA Framework (FY2025)

The Spent Fuel and Waste Science and Technology Campaign (SFWST) of the U.S. Department of Energy (DOE) Office of Nuclear Energy (NE) is conducting research and development on geologic disposal of spent nuclear fuel (SNF) and high-level nuclear waste (HLW). Two priorities for SFWST are design concept development and disposal system modeling. These priorities are directly addressed in the Geologic Disposal Safety Assessment (GDSA) control account, which is charged with developing a geologic repository system modeling and analysis capability, and the associated software, GDSA Framework, for evaluating disposal system performance for nuclear waste in geologic media. This report describes specific activities in the Fiscal Year (FY) 2025 associated with the GDSA Uncertainty and Sensitivity Analysis Methods work package. This report fulfills the GDSA Uncertainty and Sensitivity Analysis Methods work package (SF-25SN01030407) level 3 milestone, Uncertainty and Sensitivity Analysis Methods and Applications in GDSA Framework (FY2025) (M3SF-25SN010304072). This work was closely coordinated with the other Sandia National Laboratory GDSA work packages: the GDSA Framework Development work package (SF-25SN01030408), the GDSA Repository Systems Analysis work package (SF-25SN01030409), and the GDSA PFLOTRAN Development work package (SF-25SN01030410). This report builds on developments reported in previous GDSA Framework milestones, particularly M3SF-24SN010304072.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W

A Sensitive Electrochemical Cholinesterase-Inhibiting Biosensor for Organophosphorus Pesticides Based on Ti 3 C 2 TX MXene Quantum Dots

Organophosphorus pesticides (OPs) pose significant environmental and health risks due to their widespread use and toxicity, primarily by inhibiting acetylcholinesterase. Traditional detection methods are often slow and costly, highlighting the urgent need for advanced, sensitive, and accessible technologies. This study developed a highly sensitive electrochemical cholinesterase-inhibiting biosensor for OP pesticides, utilizing Ti 3 C 2 T x MXene Quantum Dots (MQDs), which was synthesized via a hydrothermal method. The biosensor’s performance was characterized using electrochemical impedance spectroscopy, differential pulse voltammetry (DPV), and cyclic voltammetry. DPV proved to be the optimal technique, exhibiting an ultralow detection limit of 1 × 10 −17 M and a wide linear range (10 −14 –10 −8 M) for chlorpyrifos (a model OP) with an estimated inhibition constant of 62 nM. The biosensor demonstrated high selectivity for OPs (chlorpyrifos, acephate, glyphosate) over a non-target pyrethroid (permethrin), confirmed by distinct electrochemical signatures and compared to in vitro cholinergic activity assays in bean beetle homogenates. The enhanced performance is attributed to the high surface-to-volume ratio, quantum confinement effects, and superior conductivity of the MQDs, as well as the robust enzyme immobilization facilitated by glutaraldehyde cross-linking and a chitosan matrix. This work presents a promising platform for rapid, sensitive, and selective detection of OP pesticides, with potential applications in environmental monitoring and public health protection.

Chemistry

Evidence for a cytokine-sensitive network of iron-associated genes that protects pancreatic islets against ferroptosis

Background/Objectives: The micronutrient iron is closely connected to inflammation and is among the complex factors contributing to beta-cell failure in diabetes. High levels of dietary iron increase the risk of developing type 2 diabetes, and excessive iron uptake by beta-cells can cause oxidative stress and inhibit function. Elevated levels of proinflammatory cytokines in obese individuals, such as interleukin (IL)-1beta and IL-6, increase the risk of developing type 2 diabetes, and there is evidence that these low levels of circulating cytokines can lead to islet dysfunction. Methods: In this study, gene microarray and other data were analyzed for expression differences in islets treated for 48 h with 10 pg/mL IL-1beta + 20 pg/mL IL-6 as a model of low-grade inflammation versus untreated. Results: Three iron-associated genes were among the most cytokine-sensitive in the mouse genome: Hamp, Steap4, and Lcn2. These proteins are all involved with increasing/retaining cellular iron. We hypothesized that increased cellular iron would lead to increased susceptibility to ferroptosis. Surprisingly, 24 h pre-exposure to low-grade inflammation, which upregulates this iron-gene network, prevented subsequent erastin-induced ferroptosis. We also found that Steap4 overexpression reduced islet dysfunction caused by high-dose proinflammatory cytokines (10× low-dose), suggesting an overall protective effect. Steap4 overexpression also upregulated Hamp and Lcn2, suggesting Steap4 regulates these cytokine-sensitive iron genes.; in contrast, ferritin and ferroportin gene expression, which are not sensitive to cytokines, were unchanged. Conclusions: These data suggest an inflammation-induced network of genes involved in cellular iron uptake and retention plays a protective role in islets against oxidative stress and ferroptosis.

IL-1β

High sensitivity of simulated fog properties to parameterized aerosol activation in case studies from ParisFog

Aerosols influence fog properties such as visibility and lifetime by affecting fog droplet number concentrations (N d ). Numerical weather prediction (NWP) models often represent aerosol–fog interactions using highly simplified approaches. Incorporating prognostic size-resolved aerosol microphysics from climate models could allow them to simulate N d and aerosol–fog interactions without incurring excessive computational expense. However, microphysics code designed for coarse spatial resolution may struggle with sub-kilometer-scale grid spacings. Here, we test the ability of the UK Met Office Unified Model to simulate aerosol and fog properties during case studies from the ParisFog field campaign in 2011. We examine the sensitivity of fog properties to variations in N d caused by modifications to simulated aerosol activation. Our model, with a 500 m horizontal resolution and interactive aerosol and cloud microphysics, significantly underpredicts N d , although it only slightly underestimates the cloud condensation nuclei concentration. With an updated version of the Abdul-Razzak and Ghan (2000) activation scheme, we produce N d that are more consistent with those predicted by a cloud parcel model under fog-like conditions. We activate droplets only by adiabatic cooling. We incorporate more realistic hygroscopicities for sulfate and organic aerosols and explore the sensitivity of simulated N d to unresolved updrafts. We find that both N d and simulated fog liquid water content are very sensitive to the updated activation scheme but remain less affected by the update to hygroscopicities. Our improvements offer insights into the physical processes regulating N d in stable conditions, potentially laying foundations for improved operational fog forecasts that incorporate interactive aerosol simulations or aerosol climatologies.

Ghosh, Pratapaditya [Carnegie Mellon University, P

Simulating Alpha Particles Incident on MKID Chips for Quantum Sensitivity Analysis

Superconducting quantum devices, such as microwave kinetic inductance detectors (MKIDs), are highly sensitive instruments used in quantum computing and advanced sensing technologies. However, their extreme sensitivity also makes them vulnerable to background noise from natural sources like radiation. One significant contributor to this noise is alpha particles emitted by 210Po, a radon decay daughter that accumulates on surfaces near the detector. This project investigates how alpha particles emitted from 210Po interact with MKID chips. These particles can deposit energy on the detector surface, disrupting its operation and generating false signals. Understanding the energy and behavior of these particles is crucial for improving the design and reliability of quantum devices. To explore this, we first modeled the decay chain starting from 210Pb to 210Po using differential equations. This allowed us to predict how the activity of alpha-emitting isotopes changes over time, reaching a steady state after about two years. Next, we simulated alpha particle interactions with the MKID chip using the Geant4 software toolkit. We built a detailed computer model of the detector housing, including the copper lid where alpha particles originate, the silicon chip, and a thin aluminum sensor layer. Alpha particles were emitted isotropically from just beneath the copper lid’s surface, mimicking natural decay conditions. The simulation tracked how these particles deposit energy on the chip, generating electron-hole pairs and phonons. The results provide insight into the behavior of the resultant electron-hole pairs and phonons, giving us a clear understanding of the energy deposition distribution on the chip. This work supports efforts to mitigate background noise in superconducting sensors, advancing their use in quantum computing and sensitive physics experiments.

Hall, Matthew [Fermilab; UCLA]

Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme

The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector. *************************************** AUTHOR = Slater, Bethany University of Liverpool b.slater2@liverpool.ac.uk TITLE = Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme PAGES = 218 NOTE = Ph.D. University of Liverpool March 2026 ABSTRACT = The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector.

Slater, Bethany [Liverpool U.]

Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme

The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector. *************************************** AUTHOR = Slater, Bethany University of Liverpool b.slater2@liverpool.ac.uk TITLE = Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme PAGES = 218 NOTE = Ph.D. University of Liverpool March 2026 ABSTRACT = The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector.

Slater, Bethany [Liverpool U.]

Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme

The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector. *************************************** AUTHOR = Slater, Bethany University of Liverpool b.slater2@liverpool.ac.uk TITLE = Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme PAGES = 218 NOTE = Ph.D. University of Liverpool March 2026 ABSTRACT = The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector.

Slater, Bethany [Liverpool U.]

Sensitivity of Next-Generation CMB Surveys to Neutrinos and Other Light Relics

Neutrinos and other light relics leave characteristic imprints in the cosmic microwave background anisotropies, making their observation a sensitive probe of the particle content and thermal history of the early universe. The energy density in these relativistic species is parameterized by their effective number $N_\mathrm{eff}$. Measuring this parameter at the percent level, which is a long-standing science goal of CMB-S4 and other experiments, would test a wide range of well-motivated physics within and beyond the Standard Model of particle physics. In this paper, we present Fisher-matrix forecasts of the projected sensitivity to $N_\mathrm{eff}$ of several CMB-S4 survey configurations considered during its extensive design phase. The conceptual design reaches $σ(N_\mathrm{eff}) < 0.03$ over its seven-year observing period, while the revised configuration achieves the same precision over a longer timescale. We complement these results with a cosmic-variance-limited survey over the same multipole range to quantify the room for improvement accessible with additional instrumental, observational, and theoretical efforts. Finally, we discuss the broad implications of precise $N_\mathrm{eff}$ measurements for the radiation sector, big bang nucleosynthesis, light thermal relics, and other early-universe physics. The forecasts presented in this work are performed with the publicly released DRAFT (Dark Radiation Anisotropy Flowdown Team) tool. It provides an end-to-end pipeline from simulated foreground maps and component separation to delensing and projected sensitivities for any cosmological parameter, and it can be directly applied to other cosmic microwave background survey designs.

Trendafilova, Cynthia [Case Western Reserve U., CE

Refined Sensitivity Estimates for Single-Molecule Magnet Dark Matter Detectors

We revisit the sensitivity of Single Molecule Magnet (SMM) crystals as detectors for low-mass dark matter. In previous work, we established the concept of the ``magnetic bubble chamber'', where energy deposited by dark matter triggers a magnetic avalanche in a metastable crystal. The original sensitivity estimates relied on a conservative criterion requiring the spin relaxation time to be strictly shorter than the thermal diffusion time. Here, we demonstrate that this criterion effectively ignores the stochastic nature of spin relaxation. We derive a refined analytic estimate which accounts for the fraction of spins that relax even when diffusion is fast. We show that the Zeeman energy released by this fraction contributes to local heating, significantly lowering the energy threshold for avalanche formation. We present simulation results confirming this effect and report on experimental verification of the assumed low-temperature thermal properties of two representative SMM crystals, Mn$_{12}$-acetate and Mn$_{32}$. Together, these efforts extend this pathfinder program toward the realization of SMM-based detectors with controlled material properties and enhanced dark matter sensitivity.

Eberhardt, Andrew [Tokyo U., IPMU]

Beyond $Δm^2$: Absolute Mass Sensitivity in Neutrino Oscillations

Conventional wisdom says that neutrino oscillations measure only mass-squared differences and not the absolute neutrino mass scale. This is true, however, only at leading order in the expansion parameters $m_i/E$, the ratios of the neutrino masses $m_i$ ($i=1,2,3$) to the neutrino energy $E$. At next-to-leading order, the oscillation phase includes terms proportional to $m_i^4-m_j^4 = Δm^2_{ij}(m_i^2+m_j^2)$, and is therefore sensitive to the absolute mass scale. In this paper, we derive the next-to-leading-order corrections using a wave-packet treatment and taking into account the neutrino-production kinematics. We then apply this result to reactor antineutrinos and find that the JUNO experiment is sensitive to neutrino masses of a few hundred keV. While not competitive with existing bounds from beta decay, electron capture, and cosmology, neutrino oscillations provide a novel, complementary probe of the neutrino mass scale, with sensitivity to a different combination of neutrino masses.

Alves, Gustavo F.S. [Fermilab; Argonne; Northweste

Triplet Exciton Sensitization of Silicon Mediated by Defect States in Hafnium Oxynitride

Singlet exciton fission has the potential to increase the efficiency of crystalline silicon solar cells beyond the conventional single junction limit. Perhaps the largest obstacle to achieving this enhancement is uncertainty about energy coupling mechanisms at the interfaces between silicon and exciton fission materials such as tetracene. Here, the previously reported silicon‐hafnium oxynitride‐tetracene structure is studied and a combination of magnetic‐field‐dependent silicon photoluminescence measurements and density functional theory calculations is used to probe the influence of the interlayer composition on the triplet transfer process across the hafnium oxynitride interlayer. It is found that hafnium oxide interlayers do not show triplet exciton sensitization of silicon, and that nitrogen content in hafnium oxynitride layers is correlated with enhanced sensitization. Calculation results reveal that defects in hafnium oxynitride interlayers with higher nitrogen content introduce states close to the band‐edge of silicon, which can mediate the triplet exciton transfer process. Some defects introduce additional deleterious mid‐gap states, which may explain observed silicon photoluminescence quenching. These results show that band‐edge states can mediate the triplet exciton transfer process, potentially through a sequential charge transfer mechanism.

36 MATERIALS SCIENCE

Modelling the Sensitivity of Yukon River Biogeochemical Dynamics to Environmental and Chemical Drivers: Implications for Dissolved Organic Carbon

Riverine dissolved organic carbon (DOC) is a critical biogeochemical component that transmits information from Arctic soils to the Arctic Ocean, significantly influencing carbon dynamics in this unique ecosystem. As DOC travels downstream, it undergoes transformations that alter its composition and fate. The Yukon River serves as an effective testbed for modelling these dynamics, offering sufficient scale to capture key biogeochemical processes while having a simpler hydrology than other major Arctic rivers, as well as long-term DOC observational data for model validation. To investigate DOC transformations during transit in the Yukon River, we adapted our Arctic Riverine Organic Macromolecular Model by applying regional-specific parameterisations. Our model simulates the transport and transformation of 15 organic macromolecules, including CDOM (coloured dissolved organic matter), proteins, polysaccharides, lipids, lignin phenols, and humic substances. Initial DOC concentrations were derived from observed soil organic carbon stocks in the surrounding watershed, while chemical transformations and hydrological dynamics were modelled along the river's course. Sensitivity and uncertainty analyses were conducted using a Monte Carlo approach under two experimental setups. Results revealed that variability in DOC and CDOM concentrations at the river mouth were predominantly driven by initial DOC concentration (~70% of variability explained) and dilution at confluence points (~10%). The refractory fraction of DOC explained 21%–88% of the variability in 14 macromolecular concentrations and ranked in the top five sensitive parameters for all outputs when a uniform parameter distribution was assumed. However, when a more likely variability was applied to this parameter, its influence on DOC and CDOM decreased. Given that refractory DOC accounts for ~80% of total DOC in Arctic Rivers, this suggests that most DOC resists degradation and retains its chemical composition during transport to the coastal environment. River velocity, which determines residence time, explained 8%–47% of the variability in protein, polysaccharide, lipid, pigments, and lignin phenols at the river mouth. In contrast, chemical turnover times contributed only 1%–5% to output variability. Our findings underscore the need for improved land-specific headwater observations, including seasonal soil moisture and lateral transport dynamics that control the initial tributary-specific DOC inputs. With accelerated permafrost thaw and increasing river discharge, extending our model to other Arctic River systems and seasons will enhance understanding of Arctic riverine carbon fluxes and their contributions to the Arctic Ocean.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Development of copper thiolate organometallic compound as thermal sensitive coating for energy storage system safety

Safety and reliability are primary concerns for the deployment of lithium-ion batteries, especially in electric vehicles (EV) and larger-scale energy storage systems (ESS). Current technology in battery management systems (BMS) includes cell voltage monitoring and positioning temperature sensors in selected locations. For a system with hundreds to thousands of individual batteries, single-point temperature monitoring is inadequate to detect hot spots and cell overheating, which could lead to thermal runaway. Here, we have developed a temperature-sensitive copper-thiol compound that can be directly coated onto battery pouch foils to enable early detection of thermal runaway. Upon reaching specific temperatures, this compound releases a sulfur-containing detectable gas, which can be identified using chemically specific gas sensors to trigger an early warning signal. Such a signal propagate through air offers broad signal coverage and enables a more comprehensive approach to large-area temperature monitoring. The Cu-ethanethiol coating is designed to release volatile gases when the substrate surface temperature exceeds 70 °C, with continuous outgassing as the temperature increases. The compound is composed of Cu, S, Cl, hydrocarbons and trace amounts of oxygen. Upon heating, the oxidation state of Cu(I) transitions to Cu (II), accompanied by gas release. Thermogravimetric analysis coupled with mass spectrometry correlated well with the onset of gas release temperature and emission of sulfur-containing volatile gases. Additionally, an acrylic overcoat is applied to enhance the adhesion of the thermally sensitive compound film to the battery pouch foil. This coating is expected to offer an additional safety layer for ESS, alerting possible thermal runaway events before a failure occurs, thereby allowing sufficient time to implement a mitigation plan.

Early warning systems