Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sensor Depth”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Utah FORGE: GES Well 16A(78)-32 and Well 16B(78)-32 Stimulation Seismic Event Catalogs

This dataset contains seismic event catalogs from the hydraulic stimulation of wells 16A(78)-32 and 16B(78)-32 at the Utah FORGE site in April 2024. The data was collected by Geo Energy Suisse (GES) using a variety of seismic monitoring technologies, including 3-component (3C) geophones and distributed acoustic sensing (DAS) systems. These technologies were deployed across several locations, including wells 16A, 16B, and Delano-1, with sensor arrays at multiple depths to capture microseismic activity during the stimulations. The catalogs provide both real-time and manually checked seismic event locations, with detailed parameters such as trigger conditions, velocity models, and data acquisition settings. The dataset includes information on the stimulation stages, event rates, and hydraulic injection conditions for each well, with a report detailing the data acquisition configuration and seismic event location methodologies. Users will need to reference the included report for a complete understanding of the sensor network, data processing techniques, and accuracy considerations.

15 GEOTHERMAL ENERGY↗

Calibration of the SNPP and NOAA 20 VIIRS Sensors for Continuity of the MODIS Climate Data Records

Accurate long-term sensor calibration and periodic re-processing to ensure consistency and continuity of atmospheric, land and ocean geophysical retrievals from space within the mission period and across different missions is a major requirement of climate data records. In this work, we applied the Multi-Angle Implementation of Atmospheric Correction (MAIAC)-based vicarious calibration technique over Libya-4 desert site to perform calibration analysis of Visible Infrared Imaging Radiometer Suite (VIIRS) on Suomi National Polar-orbiting Partnership (SNPP) and NOAA-20 satellites. For both VIIRS sensors we characterized residual linear calibration trends and cross-calibrated both sensors to MODerate resolution Imaging Spectroradiometer (MODIS) Aqua regarded as a calibration standard. The relative spectral response (RSR) differences were accounted for using the German Aerospace Center (DLR) Earth Sensing Imaging Spectrometer (DESIS) hyperspectral surface reflectance data. Our results agree with independent vicarious calibration results of both the MODIS/VIIRS Characterization Support Team as well as the CERES Imager and Geostationary Calibration Group within estimated uncertainty of 1–2%. Analysis of MAIAC geophysical products with the new calibration shows a high level of agreement of MAIAC aerosol, surface reflectance and NDVI records between MODIS and VIIRS. Excluding high aerosol optical depth (AOD), all three sensors agree in AOD with mean difference (MD) less than 0.01 and residual mean squared difference rmsd ∼ 0.04. Spectral geometrically normalized surface reflectance agrees within rmsd of 0.003–0.005 in the visible and 0.01–0.012 at longer wavelengths. The residual surface reflectance differences are fully explained by differences in spectral filter functions. Finally, difference in NDVI is characterized by rmsd ∼ 0.02 and MD less than 0.003 for NDVI based on VIIRS imagery bands I1/I2 and less than 0.01 for NDVI based on VIIRS radiometric bands M5/M7. In practical sense, these numbers indicate consistency and continuity in MAIAC records ensuring the smooth transition from MODIS to VIIRS.

MAIAC↗

Identifying preferential flow from soil moisture time series: Review of methodologies

Abstract Identifying and quantifying preferential flow (PF) through soil—the rapid movement of water through spatially distinct pathways in the subsurface—is vital to understanding how the hydrologic cycle responds to climate, land cover, and anthropogenic changes. In recent decades, methods have been developed that use measured soil moisture time series to identify PF. Because they allow for continuous monitoring and are relatively easy to implement, these methods have become an important tool for recognizing when, where, and under what conditions PF occurs. The methods seek to identify a pattern or quantification that indicates the occurrence of PF. Most commonly, the chosen signature is either (1) a nonsequential response to infiltrated water, in which soil moisture responses do not occur in order of shallowest to deepest, or (2) a velocity criterion, in which newly infiltrated water is detected at depth earlier than is possible by nonpreferential flow processes. Alternative signatures have also been developed that have certain advantages but are less commonly utilized. Choosing among these possible signatures requires attention to their pertinent characteristics, including susceptibility to errors, possible bias toward false negatives or false positives, reliance on subjective judgments, and possible requirements for additional types of data. We review 77 studies that have applied such methods to highlight important information for readers who want to identify PF from soil moisture data and to inform those who aim to develop new methods or improve existing ones. Core Ideas Soil moisture data can be used to identify the occurrence of preferential flow (PF) and its initiating conditions. Various data‐analysis methods to identify PF differ in susceptibility to error, bias, and subjectivity. These methods can utilize vast amounts of data from soil moisture monitoring networks to develop understanding of when, where, and under what conditions PF occurs. Newly developed methods may lead to better accuracy and reliability, and reduce the need for subjective judgments. Plain Language Summary Preferential flow through soil occurs when a large amount of water is suddenly available, as during an intense storm. This type of flow moves rapidly through the soil in distinct narrow pathways rather than moving evenly throughout the body of soil, with major consequences for groundwater resources, ecosystems, spreading of contaminants, and other vital concerns. Methods of detecting preferential flow have been developed that utilize measurements of soil water content made by sensors installed at various depths. This measurement technology has been widely implemented, many locations now having datasets years in length, and various methods have been developed for using these to identify preferential flow. The various methods are based on different features in the soil moisture records and vary in their advantages and shortcomings. In this review, we explain and evaluate these methods, highlighting important information for their implementation to identify preferential flow from soil moisture data and for efforts to develop new methods or improve existing ones.

Nimmo, John R↗

Raman Lidar Measurements of Water Vapor and Cirrus Clouds During the Passage of Hurricane Bonnie

The NASA/GSFC Scanning Raman Lidar (SRL) was stationed on Andros Island in the Bahamas during August - September, 1998 as a part of the third Convection and Moisture Experiment (CAMEX-3) which focussed on hurricane development and tracking. During the period August 21 - 24, hurricane Bonnie passed near Andros Island and influenced the water vapor and cirrus cloud measurements acquired by the SRL. Two drying signatures related to the hurricane were recorded by the SRL (Scanning Raman Lidar) and other sensors. Cirrus cloud optical depths (at 351 nm) were also measured during this period. Optical depth values ranged from approximately 0.01 to 1.4. The influence of multiple scattering on these optical depth measurements was studied with the conclusion that the measured values of optical depth are less than the actual value by up to 20% . The UV/IR cirrus cloud optical depth ratio was estimated based on a comparison of lidar and GOES measurements. Simple radiative transfer model calculations compared with GOES satellite brightness temperatures indicate that satellite radiances are significantly affected by the presence of cirrus clouds if IR optical depths are approximately 0.02 or greater. This has implications for satellite cirrus detection requirements.

Whiteman, D. N.↗

Raman Lidar Measurements of Water Vapor and Cirrus Clouds During the Passage of Hurricane Bonnie

The NASA/GSFC Scanning Raman Lidar (SRL) was stationed on Andros Island in the Bahamas during August - September, 1998 as a part of the third Convection and Moisture Experiment (CAMEX-3) which focussed on hurricane development and tracking. During the period August 21 - 24, hurricane Bonnie passed near Andros Island and influenced the water vapor and cirrus cloud measurements acquired by the SRL. Two drying signatures related to the hurricane were recorded by the SRL and other sensors. Cirrus cloud optical depths (at 351 nm) were also measured during this period. Optical depth values ranged from approximately 0.01 to 1.4. The influence of multiple scattering on these optical depth measurements was studied with the conclusion that the measured values of optical depth are less than the actual value by up to 20%. The UV/lR cirrus cloud optical depth ratio was estimated based on a comparison of lidar and GOES measurements. Simple radiative transfer model calculations compared with GOES satellite brightness temperatures indicate that satellite radiances are significantly affected by the presence of cirrus clouds if IR optical depths are approximately 0.02 or greater. This has implications for satellite cirrus detection requirements.

Whiteman, D. N.↗

Raman Lidar Measurements of Water Vapor and Cirrus Clouds During The Passage of Hurricane Bonnie

The NASA/GSFC Scanning Raman Lidar (SRL) was stationed on Andros Island in the Bahamas during August - September, 1998 as a part of the third Convection and Moisture Experiment (CAMEX-3) which focussed on hurricane development and tracking. During the period August 21 - 24, hurricane Bonnie passed near Andros Island and influenced the water vapor and cirrus cloud measurements acquired by the SRL. Two drying signatures related to the hurricane were recorded by the SRL and other sensors. Cirrus cloud optical depths (at 351 nm) were also measured during this period. Optical depth values ranged from less than 0.01 to 1.5. The influence of multiple scattering on these optical depth measurements was studied. A correction technique is presented which minimizes the influences of multiple scattering and derives information about cirrus cloud optical and physical properties. The UV/IR cirrus cloud optical depth ratio was estimated based on a comparison of lidar and GOES measurements. Simple radiative transfer model calculations compared with GOES satellite brightness temperatures indicate that satellite radiances are significantly affected by the presence of cirrus clouds if IR optical depths are approximately 0.005 or greater. Using the ISCCP detection threshold for cirrus clouds on the GOES data presented here, a high bias of up to 40% in the GOES precipitable water retrieval was found.

Whiteman, D. N.↗

Porous media matric potential and water content measurements during parabolic flight

Control of water and air in the root zone of plants remains a challenge in the microgravity environment of space. Due to limited flight opportunities, research aimed at resolving microgravity porous media fluid dynamics must often be conducted on Earth. The NASA KC-135 reduced gravity flight program offers an opportunity for Earth-based researchers to study physical processes in a variable gravity environment. The objectives of this study were to obtain measurements of water content and matric potential during the parabolic profile flown by the KC-135 aircraft. The flight profile provided 20-25 s of microgravity at the top of the parabola, while pulling 1.8 g at the bottom. The soil moisture sensors (Temperature and Moisture Acquisition System: Orbital Technologies, Madison, WI) used a heat-pulse method to indirectly estimate water content from heat dissipation. Tensiometers were constructed using a stainless steel porous cup with a pressure transducer and were used to measure the matric potential of the medium. The two types of sensors were placed at different depths in a substrate compartment filled with 1-2 mm Turface (calcined clay). The ability of the heat-pulse sensors to monitor overall changes in water content in the substrate compartment decreased with water content. Differences in measured water content data recorded at 0, 1, and 1.8 g were not significant. Tensiometer readings tracked pressure differences due to the hydrostatic force changes with variable gravity. The readings may have been affected by changes in cabin air pressure that occurred during each parabola. Tensiometer porous membrane conductivity (function of pore size) and fluid volume both influence response time. Porous media sample height and water content influence time-to-equilibrium, where shorter samples and higher water content achieve faster equilibrium. Further testing is needed to develop these sensors for space flight applications.

Parabolic Flight↗

Retrieving the Height of Smoke and Dust Aerosols by Synergistic Use of VIIRS, OMPS, and CALIOP Observations

Aerosol Single scattering albedo and Height Estimation (ASHE) algorithm was first introduced in Jeong and Hsu (2008) to provide aerosol layer height as well as single scattering albedo (SSA) for biomass burning smoke aerosols. One of the advantages of this algorithm was that the aerosol layer height can be retrieved over broad areas, which had not been available from lidar observations only. The algorithm utilized aerosol properties from three different satellite sensors, i.e., aerosol optical depth (AOD) and Ångström exponent (AE) from Moderate Resolution Imaging Spectroradiometer (MODIS), UV aerosol index (UVAI) from Ozone Monitoring Instrument (OMI), and aerosol layer height from Cloud-Aerosol Lidar with Orthogonal Polarization (CALIOP). Here, we extend the application of the algorithm to Visible Infrared Imaging Radiometer Suite (VIIRS) and Ozone Mapping and Profiler Suite (OMPS) data. We also now include dust layers as well as smoke. Other updates include improvements in retrieving the AOD of nonspherical dust from VIIRS, better determination of the aerosol layer height from CALIOP, and more realistic input aerosol profiles in the forward model for better accuracy.

aerosol↗

AVCOAT Density Characterization for Orion Multi-Purpose Crew Vehicle

The Orion Multi-Purpose Crew Vehicle (MPCV) will transport four crew members to and from lunar-class orbital destinations. The first orbital Exploration Flight Test (EFT-1) is scheduled for December 2014 and will provide valuable data on several systems, including the heat shield. The heat shield material is AvcoatTM, a mid-density ablator. Specifically, the heat shield contains a fiberglass-phenolic honeycomb structure filled with an ablative epoxy novolac resin. Post-flight characterization of the EFT-1 thermal protection system will be conducted in order to study the material response and measure the char front of the material. Avcoat density profiling will be conducted to study three critical material zones: char, pyrolysis, and virgin states as a function of material depth. As part of a ground test campaign, Avcoat coupons are tested at the NASA Ames Research Center Arc Jet Complex. The test campaign is set forth to study material response based on environments, perform Avcoat material density characterization, and compare the char depths from the HEAT sensor and density profiling studies. These investigations will then be compared to flight data in order to improve upon TPS material response models.

AVCOAT↗

Turbid water measurements of remote sensing penetration depth at visible and near-infrared wavelength

Remote sensing of water quality is dicussed. Remote sensing penetration depth is a function both of water type and wavelength. Results of three tests to help demonstrate the magnitude of this dependence are presented. The water depth to which the remote-sensor data was valid was always less than that of the Secchi disk depth, although not always the same fraction of that depth. The penetration depths were wavelength dependent and showed the greatest variation for the water type with largest Secchi depth. The presence of a reflective plate, simulating a reflective subsurface, increased the apparent depth of light penetration from that calculated for water of infinite depth.

Morris, W. D.↗

Orion Flight Test-1 Thermal Protection System Instrumentation

The Orion Crew Exploration Vehicle (CEV) was originally under development to provide crew transport to the International Space Station after the retirement of the Space Shuttle, and to provide a means for the eventual return of astronauts to the Moon. With the current changes in the future direction of the United States human exploration programs, the focus of the Orion project has shifted to the project s first orbital flight test, designated Orion Flight Test 1 (OFT-1). The OFT-1 is currently planned for launch in July 2013 and will demonstrate the Orion vehicle s capability for performing missions in low Earth orbit (LEO), as well as extensibility beyond LEO for select, critical areas. Among the key flight test objectives are those related to validation of the re-entry aerodynamic and aerothermal environments, and the performance of the thermal protection system (TPS) when exposed to these environments. A specific flight test trajectory has been selected to provide a high energy entry beyond that which would be experienced during a typical low Earth orbit return, given the constraints imposed by the possible launch vehicles. This trajectory resulted from a trade study that considered the relative benefit of conflicting objectives from multiple subsystems, and sought to provide the maximum integrated benefit to the re-entry state-of-the-art. In particular, the trajectory was designed to provide: a significant, measureable radiative heat flux to the windward surface; data on boundary transition from laminar to turbulent flow; and data on catalytic heating overshoot on non-ablating TPS. In order to obtain the necessary flight test data during OFT-1, the vehicle will need to have an adequate quantity of instrumentation. A collection of instrumentation is being developed for integration in the OFT-1 TPS. In part, this instrumentation builds upon the work performed for the Mars Science Laboratory Entry, Descent and Landing Instrument (MEDLI) suite to instrument the OFT-1 ablative heat shield. The MEDLI integrated sensor plugs and pressure sensors will be adapted for compatibility with the Orion TPS design. The sensor plugs will provide in-depth temperature data to support aerothermal and TPS model correlation, and the pressure sensors will provide a flush air data system for validation of the entry and descent aerodynamic environments. In addition, a radiometer design will be matured to measure the radiative component of the reentry heating at two locations on the heat shield. For the back shell, surface thermocouple and pressure port designs will be developed and applied which build upon the heritage of the Space Shuttle Program for instrumentation of reusable surface insulation (RSI) tiles. The quantity and location of the sensors has been determined to balance the needs of the reentry disciplines with the demands of the hardware development, manufacturing and integration. Measurements which provided low relative value and presented significant engineering development effort were, unfortunately, eliminated. The final TPS instrumentation has been optimized to target priority test objectives. The data obtained will serve to provide a better understanding of reentry environments for the Orion capsule design, reduce margins, and potentially reduce TPS mass or provide TPS extensibility for alternative missions.

Kowal, T. John↗

A Distributed Temperature Profiling System for Vertically and Laterally Dense Acquisition of Soil and Snow Temperature: Supporting Data

This dataset was used to assess the potential of a Distributed Temperature Profiling System developed and presented in the article named "A Distributed Temperature Profiling System for Vertically and Laterally Dense Acquisition of Soil and Snow Temperature" and submitted to Cryosphere. There are three comma-delimited data files (.csv). Each of them contains snow or soil temperature with times (UTC) in the first column and temperature at various vertical distance from the ground surface (positive means in air/snow) or below the ground surface (negative means in soil). The measurements were acquired every 15 minutes. Data collected at the East River, Colorado site with two probes: 1) measuring air/snow temperature from 1.1 m above the ground surface to the ground surface (with 5 or 10 cm spacing between sensors) and 2) measuring soil temperature from the ground surface to 0.7 m depth (with 5 or 10 cm spacing between sensors). Data collected at the Teller road (mile 27) site near Nome, Alaska with one probe: measuring soil temperature from 5 cm above the ground surface to 1.05 m depth (with 5 or 10 cm spacing between sensors). Additional metadata included in *.csv and *.pdf files. NGEE Arctic Project Summary: The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Groundwater table elevation and temperature from 2015 to 2024 at the Lower Montane site in the East River Watershed, Colorado.

This groundwater level elevation and temperature data package is aimed at improving the predictive understanding of hydro-biogeochemical processes at the lower montane site in the East River Watershed, Colorado. The dataset is obtained using pressure transducers placed in shallow wells in the floodplain. This dataset contains data from wells with Location ID's ER-DOW (alias DO1West), ER-DOE (alias DO2East), ER-MBA1 (alias M1Bend1), ER-MBA2 (alias M1Bend2), ER-UPW (alias UP1West), ER-UPM (alias UP2), ER-UPE (alias UP3East). Another dataset contains the data from wells with Location ID's ER-CPA1 to ER-CPA6. Each file contains the water level elevation and the water temperature. Water level elevation has been obtained using the barometric pressure from the pressure transducer (Hobos sensor) in the well, barometric pressure from a sensor in air located at the same site (lower montane), depth from top-of-casing (TOC) to sensor measurement point, and TOC elevation. Data have been checked with a few measurements of water table depths. A real-time kinematic (RTK) global positioning system (GPS) has been used to survey the TOC (data in file Well_Location.csv). The water level elevation is given in UTM13N Geoid2012AB. While depth to water level is not present in the data files, it can be easily calculated with the TOC and distance to ground provided in the GPS coordinate file. The dataset quality is discussed in Collection/Analysis section of the methods. Time-series of measurements were initially added to the archive for the period 2015 to 2019, and later updated with time-series until 2024 (end of data collection). The dataset contains 8 *.csv data files, and 3 *.csv metadata files. Feel free to contact the author with any questions or collaboration interests. The publication year was updated from "2020" to "2025" to reflect the revised version of this dataset.

54 ENVIRONMENTAL SCIENCES↗

Groundwater table elevation and temperature from 2015 to 2024 across Meander C at the Lower Montane site in the East River Watershed, Colorado.

This groundwater level elevation and temperature data package is aimed at improving the predictive understanding of hydro-biogeochemical processes at the lower montane site in the East River Watershed, Colorado. The dataset is obtained using pressure transducers placed in shallow wells in the floodplain. This dataset contains data from wells ER-CPA1 to ER-CPA6. Another dataset contains the data from wells at nearby Locations. Each file contains the water level elevation and the water temperature. Water level elevation has been obtained using the barometric pressure from the pressure transducer (Hobos sensor) in the well, barometric pressure from a sensor in air located at the same site (lower montane), depth from top-of-casing (TOC) to sensor measurement point, and TOC elevation. Data have been checked with a few measurements of water table depths. A real-time kinematic (RTK) global positioning system (GPS) has been used to survey the TOC (data in file Well_Location.csv). The water level elevation is given in UTM13N Geoid2012AB. While depth to water level is not present in the data files, it can be easily calculated with the TOC and distance to ground provided in the GPS coordinate file. The dataset quality is discussed in Collection/Analysis section of the methods. Time-series of measurements were initially added to the archive for the period 2015 to 2019, and later updated with time-series until 2024 (end of data collection). The dataset contains 7 *.csv data files, and 3 *.csv metadata files. Feel free to contact the author with any questions or collaboration interests. The publication year was updated from "2020" to "2025" to reflect the revised version of this dataset.

54 ENVIRONMENTAL SCIENCES↗

Error analysis of combined stereo/optical-flow passive ranging

The motion of an imaging sensor causes each imaged point of the scene to correspondingly describe a time trajectory on the image plane. The trajectories of all imaged points are reminiscent of a flow (e.g., of liquid) which is the source of the term 'optical flow'. Optical-flow ranging is a method by which the stream of two-dimensional images obtained from a forward-looking forward-moving passive sensor is used to compute depth (or range) to points in the field of view. Another well-known ranging method consists of triangulation based on stereo images obtained from at least two stationary sensors. In this paper we analyze the potential accuracies of a combined optical flow and stereo passive-ranging system in the context of helicopter nap-of-the-earth obstacle avoidance. The Cramer-Rao lower bound is developed for the combined system under the assumption of an unknown angular bias error common to both cameras of a stereo pair. It is shown that the depth accuracy degradations caused by a bias error is negligible for a combined optical-flow and stereo system as compared to a monocular optical-flow system.

Barniv, Yair↗

Calibrated intercepts for solar radiometers used in remote sensor calibration

Calibrated solar radiometer intercepts allow spectral optical depths to be determined for days with intermittently clear skies. This is of particular importance on satellite sensor calibration days that are cloudy except at the time of image acquisition. This paper describes the calibration of four solar radiometers using the Langley-Bouguer technique for data collected on days with a clear, stable atmosphere. Intercepts are determined with an uncertainty of less than six percent, corresponding to a maximum uncertainty of 0.06 in optical depth. The spread of voltage intercepts calculated in this process is carried through three methods of radiometric calibration of satellite sensors to yield an uncertainty in radiance at the top of the atmosphere of less than one percent associated with the uncertainty in solar radiometer intercepts for a range of ground reflectances.

Gellman, David I.↗

Differential Measurement Periodontal Structures Mapping System

This invention relates to a periodontal structure mapping system employing a dental handpiece containing first and second acoustic sensors for locating the Cemento-Enamel Junction (CEJ) and measuring the differential depth between the CEJ and the bottom of the periodontal pocket. Measurements are taken at multiple locations on each tooth of a patient, observed, analyzed by an optical analysis subsystem, and archived by a data storage system for subsequent study and comparison with previous and subsequent measurements. Ultrasonic transducers for the first and second acoustic sensors are contained within the handpiece and in connection with a control computer. Pressurized water is provided for the depth measurement sensor and a linearly movable probe sensor serves as the sensor for the CEJ finder. The linear movement of the CEJ sensor is obtained by a control computer actuated by the prober. In an alternate embodiment, the CEJ probe is an optical fiber sensor with appropriate analysis structure provided therefor.

Companion, John A.↗

Application of Low-Cost Fine Particulate Mass Monitors to Convert Satellite Aerosol Optical Depth Measurements to Surface Concentrations in North America and Africa

Low-cost particulate mass sensors provide opportunities to assess air quality at unprecedented spatial and temporal resolutions. Established traditional monitoring networks have limited spatial resolution and are simply absent in many major cities across sub-Saharan Africa (SSA). Satellites provide snapshots of regional air pollution but require ground-truthing. Low-cost monitors can supplement and extend data coverage from these sources worldwide, providing a better overall air quality picture. We investigate the utility of such a multi-source data integration approach using two case studies. First, in Pittsburgh, Pennsylvania, both traditional monitoring and dense low-cost sensor networks are compared with satellite aerosol optical depth (AOD) data from NASA's MODIS system, and a linear conversion factor is developed to convert AOD to surface fine particulate matter mass concentration (as PM2.5). With 10 or more ground monitors in Pittsburgh, there is a 2-fold reduction in surface PM2.5 estimation mean absolute error compared to using only a single ground monitor. Second, we assess the ability of combined regional-scale satellite retrievals and local-scale low-cost sensor measurements to improve surface PM2.5 estimation at several urban sites in SSA. In Rwanda, we find that combining local ground monitoring information with satellite data provides a 40 % improvement in surface PM2.5 estimation accuracy with respect to using low-cost ground monitoring data alone. A linear AOD-to-surface-PM2.5 conversion factor developed in Kigali, Rwanda, did not generalize well to other parts of SSA and varied seasonally for the same location, emphasizing the need for ongoing and localized ground-based monitoring, which can be facilitated by low-cost sensors. Overall, we find that combining ground-based low-cost sensor and satellite data, even without including additional meteorological or land use information, can improve and expand spatiotemporal air quality data coverage, especially in data-sparse regions.

AOD↗