Search NASA⌕ Search

SEARCH · Search NASA

Results for “Shading control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Solid modelling for the manipulative robot arm (power) and adaptive vision control for space station missions

The structure of a flexible arm derived from concatenation of the Stewart-Table-based links were studied. Solid modeling provides not only a realistic simulation, but is also essential for studying vision algorithms. These algorithms could be used for the adaptive control of the arm, using the well-known algorithms such as shape from shading, edge detection, orientation, etc. Details of solid modeling and its relation to vision based adaptive control are discussed.

Harrand, V.↗

Field validation of isotropic analytical models for simulating fabric shades

Fabric roller shades are common shading materials used in commercial and residential buildings. Accurately characterizing and modeling shades helps practitioners select the appropriate product and its control strategy based on climate and occupants' priorities, such as visual comfort and view to outdoors. Previous studies established a generalized method for modeling complex fenestration systems using data-driven tabulated bidirectional scattering distribution functions. However, deploying such a method at scale to all fabric shading products on the market is too costly and time-consuming. Analytical models that are based on a limited set of measurements (e.g., normal-normal and normal-hemispherical visible transmittance and reflectance, and directional cut-off angles) can be used to model the wide variety of shading products on the market. This study evaluates the performance of two isotropic analytical models, Roos-Wienold and Modified-Kotey, for modeling fabric roller shades, with a focus on the model's ability to predict occupant visual comfort. The performance evaluation was conducted through laboratory and field measurements and simulations. The results showed that both models are sufficient for predicting vertical illuminance at seated eye-level. Roos-Wienold model was able to predict binary visual comfort classification (glare/no-glare) under a wide range of luminance conditions, while Modified-Kotey model did not perform as well under high-contrast low-adaptation conditions. Both models are insufficient in predicting visual comfort at a four-point scale (e.g., imperceptible, perceptible, disturbing, intolerable). The two isotropic models become less accurate when the fabric exhibits high anisotropy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Instrument Thermal Test Bed - A unique two phase test facility

The Instrument Thermal Test Bed (ITTB) is a modular, large-scale test facility which provides a medium for ground testing and flight qualification of spacecraft thermal control components and system configurations. The initial 'shade-down' operations are discussed herein. Operational parameters and performance characteristics were determined and quantified on a preliminary basis. The ITTB was successfully operated at evaporator power loads ranging from 600 W to 9600 W as well as in both capillary pumped and series hybrid pumped modes.

Swanson, Theodore↗

National energy savings potential of cellular shades: A measurement and simulation study

Windows are major contributors to energy demand in residential homes because of their inferior thermal resistance compared with the opaque envelope, and sometimes from unwanted solar heat gain. Window attachments can help mitigate the energy demand by controlling the solar heat gains and enhancing window thermal resistance. Cellular shades have the potential of superior thermal performance compared with generic shades because of its honeycomb structure. Here, in this study, the team analyzed the energy savings potential of cellular shades in residential homes via experimental testing for two heating seasons and energy simulations. Five shading devices—three single-cell and two double cellular/cell-in-cell shades—were used to compare the performance with generic horizontal venetian blinds using two nearly identical side-by-side rooms in a residential home. The experimental testing showed daily heating energy savings in the range of 17%–36% compared with the case without shades. The experimental testing data also exhibited improvements in thermal comfort when using cellular shades. Additionally, energy simulations were performed to evaluate the energy savings potential of the cellular shades using a residential prototype home, which demonstrated energy savings up to 9 kWh/m2/year in cold climates. The total site energy savings for heating and cooling from cellular shades was up to ~9% for the home with a heat pump and up to ~15% for a home with a gas furnace compared with cases without any shading devices. The energy savings at a national scale were up to 14.6 TWh assuming a 20% penetration rate in residential homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Leading in Los Angeles: Demonstrating scalable emerging energy efficient technologies for integrated façade, lighting, and plug loads INTER System FLEXLAB Test Report

This report is a part of the California Energy Commission (Energy Commission) EPIC study Leading in Los Angeles: Demonstrating scalable emerging energy efficient technologies for integrated façade, lighting, and HVAC. The set of technologies are called the Integrated Technologies for Energy-efficient Retrofits (INTER) and are comprised of automated shading products and LED lighting systems with networked luminaire-level sensors and controls. In addition, the project will include control modifications and assessments of HVAC savings. This document includes the test plan and test results for the FLEXLAB® testing of the shading and lighting INTER system and related energy use impact. The test plan describes the test objectives and features, test cases, schedule, and measurements. The test results cover system performance in the lab; including lighting and HVAC energy, visual comfort, and thermal comfort.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Digital image processing of Seabeam bathymetric data for structural studies of seamounts near the East Pacific Rise

The problem of displaying information on the seafloor morphology is attacked by utilizing digital image processing techniques to generate images for Seabeam data covering three young seamounts on the eastern flank of the East Pacific Rise. Errors in locations between crossing tracks are corrected by interactively identifying features and translating tracks relative to a control track. Spatial interpolation techniques using moving averages are used to interpolate between gridded depth values to produce images in shaded relief and color-coded forms. The digitally processed images clarify the structural control on seamount growth and clearly show the lateral extent of volcanic materials, including the distribution and fault control of subsidiary volcanic constructional features. The image presentations also clearly show artifacts related to both residual navigational errors and to depth or location differences that depend on ship heading relative to slope orientation in regions with steep slopes.

Edwards, M. H.↗

Energy efficiency of a dynamic glazing system

The reduction of air-conditioning energy consumptions is one of the main indicators to act on when improving the energy efficiency in buildings. In the case of advanced technological buildings, a meaningful contribution to the thermal loads and the energy consumptions reduction could depend on the correct configuration and management of the envelope systems. In recent years, the architectural trend toward highly transparent all-glass buildings presents a unique challenge and opportunity to advance the market for emerging, smart, dynamic window and dimmable daylighting control technologies (). A prototype dynamic glazing system was developed and tested at ITC-CNR; it is aimed at actively responding to the external environmental loads. Both an experimental campaign and analyses by theoretical models were carried out, aimed at evaluating the possible configurations depending on different weather conditions in several possible places. Therefore, the analytical models of the building-plant system were defined by using a dynamic energy simulation software (EnergyPlus). The variables that determine the system performance, also influenced by the boundary conditions, were analysed, such as U- and g-value; they concern both the morphology of the envelope system, such as dimensions, shading and glazing type, gap airflow thickness, in-gap airflow rate, and management, in terms of control algorithm parameters tuning fan and shading systems, as a function of the weather conditions. The configuration able to provide the best performances was finally identified by also assessing such performances, integrating the dynamic system in several building types and under different weather conditions. The dynamic envelope system prototype has become a commercial product with some applications in facade systems, curtain walls and windows. The paper describes the methodological approach to prototype development and the main results obtained, including simulations of possible applications on real buildings. (author)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Preliminary design of a radiator shading device for a lunar outpost

The National Aeronautics and Space Administration is designing a thermal control system for an outpost to be placed permanently on the Moon. One of the functions of the thermal control system is to reject waste heat, which can be accomplished through a radiator. At the lunar equator and during the lunar midday, an unshaded radiator absorbs more heat than it rejects. This problem can be solved by using a shading device to reduce radiation incident on the radiator. The design team was asked to develop concepts for reducing the radiation incident on the radiator and for deploying the radiator and shade system for a 10 kW and a 25 kW heat rejection system. The design team was also asked to develop the best concepts into preliminary design. From the several alternatives developed by the design team, the best one was selected using a decision matrix. Preliminary design of the best concept include support structure, stress analyses, and thermal performance. In addition, the team developed ideas for removing lunar dust from the shading device. The final design solution consisted of a winged radiator shading system with a rail support structure and a scissors mechanism for deployment. The total radiator area required was calculated to be 389 sq m for the 10 kW heat rejection system and 973 sq m for the 25 kW heat rejection system.

Barron, Carlos↗

Quantifying Rates of Erosion Using Historical Aerial Photos - 19478

Erosion can play an important role in the fate and transport of waste at sites where disposal of long-lived waste is anticipated. The statistical characterization of key processes related to erosion is essential to the understanding of site stability through time. In this work multi-temporal historical aerial images are analyzed in conjunction with orthophotography and Lidar data to develop probability distributions for variables representing important erosion processes. Scans of photographic negatives were obtained for multiple photographs and several negatives were scanned with a calibrated photogrammetric scanner by Geomni (formerly Blue Skies Consulting) in Belen, New Mexico. Other negatives were provided by USDA or scanned on a high-resolution, large format media scanner in the United States National Archives Cartographic Research Room, College Park, Maryland (1939). An additional set of aerial photographs was obtained from the USGS EROS Data Center web site. For other years, photographic prints were available for aerial photography. Several prints were scanned with a large-format media scanner at 1200 dpi. Ground control points for selected digital images used in the stereoscopic analyses were identified in ArcMap. Ground control points were collected by matching features which could be identified in the aerial photography as well as the orthophotography or shaded relief imagery from the Lidar dataset. Such features included fence line intersections, road intersections, railroad bridges, and structures, depending on the age of the photography. Many old fence lines and abandoned roads remained visible in the shaded relief imagery while they were completely obscured by tree canopy in modern photography. Ground control elevations were sampled from the Lidar-based DEM or directly from point clouds. The image coordinates and matching three-dimensional projected coordinates of the ground control points were exported to IDL where parameters for a three-dimensional direct linear transformation (DLT) were obtained. Built-in singular value decomposition routines were used to solve an overdetermined set of equations for the eleven parameters of the DLT for a particular historical photograph. A solution to the DLT parameters was obtained for each historical aerial photograph in which features of interest were identified using the stereoscope. Ultimately, this process resulted in the identification of locations for features like gully heads using both the Lidar dataset and projection of the estimated location from the historical aerial photo under consideration back to the Lidar dataset. The distance between the estimate of the location from the historical image and that of the Lidar dataset was the estimated distance the feature has moved. This distance was then divided by the number of years between the Lidar dataset and the year of the historical aerial image of interest to get a rate of movement through time. This was done for several dozen points on each historical aerial image. There was inevitable uncertainty associated with the estimation of points from the historical aerial imagery. This includes estimation of changes in locations of features like gully heads through time. In this work a method to estimate the uncertainty associated with measurements of locations of features using the stereoscopic analysis is developed and applied. For features with locations in space that do not change (e.g., road intersections, etc.) the difference in measurements of locations from the Lidar dataset and that of the estimate from the historical aerial image provides an observation of the measurement error. These points used to estimate the measurement error are referred to as control points. For each of the historical aerial images, a different measurement error distribution is estimated using control points. These measurement errors are combined with the estimated distances from the stereoscopic analyses to produce distributions of gully retreat rates and hillslope erosion rates used along with output from Erosion Working Group (EWG) Landscape Evolution Models (LEMs) to provide statistical probability distributions for input into the PPA Model. Specifically, gully head retreat rate and gully widening rate were characterized using statistical probability distributions. The central limit theorem was then applied to develop rates that represent long-term averages that are used to inform a PPA Model built in GoldSim. The importance of these rates with respect to characterization of future risk can then assessed using sensitivity analyses. This provides an approach to determine if subsequent reduction of the uncertainty associated with the probability distributions of erosion rates will correspond to meaningful reduction in the estimation of future risk from the site. Ultimately this is a general method that utilizes historical aerial imagery to estimate rates of erosion with uncertainty. This information can be used to inform PPA models to project future risks from a given site. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Electron-shading effect on the horizontal aligned growth of carbon nanotubes

Based on the well-accepted electron-shading theory during plasma processing, we designed microstructures to control the local built-in electric-field on the substrate surface. The distortion magnitude of the electric-field is largest near the sidewalls of the microstructures, creating a horizontal electric-field in this region. We showed that the horizontally aligned carbon nanotubes (CNTs) were grown by making use of this built-in electric-field during the plasma-enhanced chemical vapor deposition process, with a tactical choice of geometries and materials of the microstructures on the substrate. This technique opens up a way to selectively and controllably grow horizontally aligned CNTs on the substrate surface.

36 MATERIALS SCIENCE↗

Passive solar array orientation devices for terrestrial application.

A passive solar array orientation device, called a thermal heliotrope, is described, and several terrestrial applications are illustrated. The thermal heliotrope consists of a bimetallic helical coil that serves as the motor element, producing torque and angular displacement. A control mechanism in the form of one or more shades completes the basic device. In comparison with electromechanical tracking systems, the thermal heliotrope is electrically passive, has relatively few parts, and is low cost. After describing the principle of operation and several models built for space applications, the design considerations for several terrestrial thermal heliotrope units are presented. It is suggested that the use of the thermal heliotrope for solar array orientation could significantly reduce array cost, thereby increasing the competitive economic posture of solar arrays for terrestrial applications. The thermal heliotrope modified for terrestrial use is readily adaptable to orient solar energy concentrators, such as furnaces and stills.

Fairbanks, J. W.↗

Lunar stone saw

This project addresses the problem of cutting lunar stones into blocks to be used to construct shelters to protect personnel and equipment from harmful solar radiation. This plant will manufacture 6 in x 1 ft x 2 ft blocks and will be located near the south pole to allow it to be in the shade at all times. This design uses a computer controlled robot, a boulder handler that uses hydraulics for movement, a computer system that used 3-D vision to determine the size of boulders, a polycrystalline diamond tipped saw blade that utilizes radiation for cooling, and a solar tower to collect solar energy. Only two electric motors are used in this plant because of the heavy weight of electric motors and the problem of cooling them. These two motors will be cooled by thermoelectric cooling. All other motors and actuators are to be hydraulic. The architectural design for the building as well as the conceptual design of the machines for cutting the blocks are described.

Clark, Tom↗

Active thermal control systems for lunar and Martian exploration

Several ATCS options including heat pumps, radiator shading devices, and single-phase flow loops were considered. The ATCS chosen for both lunar and Martian habitats consists of a heat pump integral with a nontoxic fluid acquisition and transport loop, and vertically oriented modular reflux-boiler radiators. The heat pump operates only during the lunar day. The lunar and Martian transfer vehicles have an internal single-phase water-acquisition loop and an external two-phase ammonia rejection system with rotating inflatable radiators. The lunar and Martian excursion vehicles incorporate internal single-phase water acquisition, which is connected via heat exchangers to external body-mounted single-phase radiators. A water evaporation system is used for the transfer vehicles during periods of high heating.

Ewert, Michael K.↗

Permanent Magnet Synchronous Motors for Commercial Refrigeration (Final Report)

This report provides background information on various fractional-horsepower electric motor technologies used for evaporator fan applications in commercial refrigeration and summarizes data from a DOE-sponsored evaporator fan motor laboratory and field demonstration project. This report also extrapolates that data to project the potential economic and environmental benefits resulting from upgrading the current installed base of commercial refrigeration evaporator fan motors to permanent magnet synchronous (PMS) motors.Evaporator fan motors used in commercial refrigeration applications are fractional horsepower in size, responsible for moving air across the evaporator coil, and typically run at one speed. Historically, shaded-pole induction motors have been the most commonly used evaporator fan motors in commercial refrigeration equipment and beverage vending machines. These are the simplest and least expensive type of fractional-horsepower motor, with an efficiency of approximately 20%. Electronically commutated (EC) permanent magnet motors, also known as brushless DC motors, were initially commercialized in the late 1980s, and their use in commercial refrigeration applications has increased within the last 10 to 15 years because of economic incentives and regulatory requirements. State-of-the-art EC motors are approximately 66% efficient. Another induction motor type, the permanent split capacitor (PSC) motor, offers a mid-point between shaded-pole and EC motor price and efficiency levels. PSC motors are typically about 29% efficient.A permanent magnet synchronous (PMS) AC motor that can directly use grid-supplied AC current without the need to rectify to DC has recently been commercialized. This new motor exhibits a peak efficiency of 75% and has the potential to significantly reduce the energy consumption of evaporator fan motors in commercial refrigeration equipment. Laboratory evaluation of evaporator fan motor technologies was performed to quantify and compare the performance of shaded-pole, PSC, EC, and PMS evaporator fan motors in a controlled environment, so as to minimize the influence of external factors and anomalies. The laboratory evaluation included dynamometer testing of the fan motors and airflow testing of the motor/fan assemblies. It was found that the 6–12 W PMS motor exhibited a peak efficiency of 75% with a power factor of approximately 0.9 at a power output of 11 W. It was also found that a 38–50 W PMS motor exhibited a peak efficiency of 82% with a power factor of approximately 0.9 at a power output of 35 W.Airflow testing of shaded-pole, PSC, EC, and PMS motor/fan assemblies was performed using an airflow test chamber, which was designed in accordance with ANSI/AMCA Standard 210-16/ASHRAE Standard 51-16, to measure the performance of the subject motor/fan assembly and to determine the incumbent display case system impedance (AMCA 2016). A family of fan curves (static pressure vs airflow rate and electrical power input vs airflow rate) was generated for the 6–12 W PMS motor/fan assemblies with 8-inch fan blades pitched from 17 to 32 degrees. A similar set of curves was generated for the 38–50 W motors paired with 10 and 12-inch blades. Various incumbent motor/fan assemblies were also tested in the laboratory airflow test chamber and their fan curves were generated.Field evaluation of refrigerated display case evaporator fan motors was accomplished by performing side-by-side comparisons of 6–12 W PMS motors to 6–12 W shaded-pole and EC evaporator fan motors. It was found that, on average, a PMS motor consumes 79% less power and draws 82% less current than a shaded pole motor, and on average, 34% less power and 49% less current than an EC motor. In addition, the PMS motor exhibits an average power factor of approximately 0.82, which is on average 40% greater than that of existing evaporator fan motors.Two field test sites were selected to evaluate the performance of the larger 38 to 50 W PMS evaporator fan motors in walk-in cooler/freezer applications. At each supermarket, two walk-in units were selected for investigation: one walk-in dairy cooler and one walk-in freezer. A 61% decrease in fan motor power was measured when retrofitting existing evaporator fan motors with PMS motors in the walk-in cooler. In addition, a 48% decrease in fan motor power was measured when retrofitting existing evaporator fan motors with PMS motors in the walk-in freezer.The culmination of the field evaluation of fan motor technologies was a whole-store retrofit conducted at a supermarket. Pre- and post-retrofit measurement of evaporator fan motor power in medium- and low-temperature refrigerated display cases and walk-in coolers/freezers was performed. Overall for the whole-store retrofit, the current supplied to all monitored evaporator fan motors was reduced by 52%, the real power was reduced by 46% and the apparent power was reduced by 51% following the retrofit of the 262 evaporator fan motors that w

42 ENGINEERING↗

Re-Assessment of "Water on the Moon" after LCROSS

The LCROSS Mission has produced information about the possible presence of water in a permanently shaded regions of the Moon. Without the opportunity to have a controlled impact into a sun-lite site on the Moon, the LCROSS information must be carefully evaluated. The Apollo samples have provided a large amount of information on the nature of lunar hydrogen, water and other volatiles and this information must be considered in any interpretation of the observed data from the LCROSS and other lunar missions. Perhaps the volatiles seen by the LRO/LCROSS mission might be identical to lunar volatiles within ordinary lunar equatorial materials. Until the control experiment of having an impactor strike an equatorially site is carried out, caution must be taken when interpreting the results from the LCROSS mission.

Gibson, Everett K.↗

An evaluation of the demand response potential of integrated dynamic window and HVAC systems

Demand response (DR) increases the flexibility and reliability of the electricity grid as use of intermittent renewable energy sources increases. HVAC and envelope DR measures present the largest aggregate energy and peak demand savings potential of all commercial building end uses because their net demand savings occur during critical peak demand periods. Controllable envelope measures include switchable electrochromic windows, operable window attachments such as outdoor louvers, roller shades, and awnings, as well as other innovative facade technologies that can modulate both solar heat gain and daylight admission over a broad solar-optical range. This study evaluated the technical potential of DR-enabled dynamic windows to reduce critical peak demand for a prototypical medium office building situated in all 16 U.S. climates. Model predictive control (MPC) algorithms were designed to minimize electricity cost in daylit perimeter office zones through control of an electrochromic window with and without HVAC thermostat setpoint control. Conventional and time-of-use rates were used to shape the degree of DR. Median annual peak demand savings with window and thermostat control across all climate zones were 24.3 kW (4.4 W/m 2 ) per building or 15.9 W/m 2 for non-north perimeter zones. Resource adequacy at the whole building level was estimated to be 13.1 to 43.4 $/kW per year over the 30-year life of the installation. Co-benefits were increased energy efficiency, and reduced electricity cost and emissions. Visual and thermal comfort requirements were met at all times. Dynamic facades controlled by MPC have substantial technical potential for DR across all U.S. climates and warrant serious consideration for inclusion in DR portfolios.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Plant Growth Environments with Programmable Relative Humidity and Homogeneous Nutrient Availability

We describe the design, characterization, and use of “programmable”, sterile growth environments for individual (or small sets of) plants. The specific relative humidities and nutrient availability experienced by the plant is established (RH between 15% and 95%; nutrient concentration as desired) during the setup of the growth environment, which takes about 5 minutes and <1$ in disposable cost. These systems maintain these environmental parameters constant for at least 14 days with minimal intervention (one minute every two days). The design is composed entirely of off-the-shelf components (e.g., LEGO1 bricks) and is characterized by (i) a separation of root and shoot environment (which is physiologically relevant and facilitates imposing specific conditions on the root system, e.g., darkness), (ii) the development of the root system on a flat surface, where the root enjoys constant contact with nutrient solution and air, (iii) a compatibility with root phenotyping. We demonstrate phenotyping by characterizing root systems of Brassica rapa plants growing in different relative humidities (55%, 75%, and 95%). While most phenotypes were found to be sensitive to these environmental changes, a phenotype tightly associated with root system topology– the size distribution of the areas encircled by roots–appeared to be remarkably and counterintuitively insensitive to humidity changes. These setups combine many of the advantages of hydroponics conditions (e.g., root phenotyping, complete control over nutrient composition, scalability) and soil conditions (e.g., aeration of roots, shading of roots), while being comparable in cost and setup time to Magenta1 boxes.

54 ENVIRONMENTAL SCIENCES↗

Scene correction (precision techniques) of ERTS sensor data using digital image processing techniques

Techniques have been developed, implemented, and evaluated to process ERTS Return Beam Vidicon (RBV) and Multispectral Scanner (MSS) sensor data using digital image processing techniques. The RBV radiometry has been corrected to remove shading effects, and the MSS geometry and radiometry have been corrected to remove internal and external radiometric and geometric errors. The results achieved show that geometric mapping accuracy of about one picture element RMS and two picture elements (maximum) can be achieved by the use of nine ground control points. Radiometric correction of MSS and RBV sensor data has been performed to eliminate striping and shading effects to about one count accuracy. Image processing times on general purpose computers of the IBM 370/145 to 168 class are in the range of 29 to 3.2 minutes per MSS scene (4 bands). Photographic images of the fully corrected and annotated scenes have been generated from the processed data and have demonstrated excellent quality and information extraction potential.

Bernstein, R.↗