Search NASA⌕ Search

SEARCH · Search NASA

Results for “Shock Tube”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Radiative Interaction Between Driver and Driven Gases in an Arc-Driven Shock Tube

An electric-arc driven shock tube was operated with hydrogen as the driven gas and either hydrogen or helium as the driver gas. Electron density was measured behind the primary shock wave spectroscopically from the width of the Beta line of hydrogen. The measured electron density values were many times greater than the values calculated by the Rankine - Hugoniot relations. By accounting for the radiative transfer from the driver gas to the driven gas, the measured electron density values were numerically recreated.

Bogdanoff, David W.↗

Relaminarization of the boundary layer over a flat plate in shock tube experiments

The relaminarization of the boundary layer over a flat plate in the shock tube was investigated by using the partially reflected shock wave technique. The flow Mach number was approximately 0.14, which corresponds to the inleft flow Mach number for the first row of vanes in a gas turbine. The thin film platinum heat gauges were used to measure the heat transfer rate and the Stanton number was calculated from the oscilloscope voltage traces. The Reynolds number was varied by changing the operation pressure of the shock tube and the values varied from 2.3 x 10 to the 4th to 5.3 x 10 to the 5th. For a Reynolds number range of 7 x 10 to the 4th to 3.5 x 10 to the 5th, the relaminarization of the boundary layer was observed. This phenomenon is due to the decay of the turbulence level in the flow as the reflected shock wave moves upstream from the flat plate. As the Reynolds number increased, the relaminarization was delayed and the delay was related to the turbulence generated by the reflected shock wave.

Hinckel, J. N.↗

Appraisal of UTIAS implosion-driven hypervelocity launchers and shock tubes.

A critical appraisal is made of the design, research, development, and operation of the novel UTIAS implosion-driven hypervelocity launchers and shock tubes. Explosively driven (PbN6-lead azide, PETN-pentaerythritetetranitrate) implosions in detonating stoichiometric hydrogen-oxygen mixtures have been successfully developed as drivers for hypervelocity launchers and shock tubes in a safe and reusable facility. Intense loadings at very high calculated pressures, densities, and temperatures, at the implosion center, cause severe problems with projectile integrity. Misalignment of the focal point can occur and add to the difficulty in using small caliber projectiles. In addition, the extreme driving conditions cause barrel expansion, erosion, and possible gas leakage from the base to the head of the projectile which cut the predicted muzzle velocities to half or a third of the lossless calculated values. However, in the case of a shock-tube operation these difficulties are minimized or eliminated and the possibilities of approaching Jovian reentry velocities are encouraging.

Glass, I. I.↗

The Interaction of a Reflected Shock Wave with the Boundary Layer in a Shock Tube

Ideally, the reflection of a shock from the closed end of a shock tube provides, for laboratory study, a quantity of stationary gas at extremely high temperature. Because of the action of viscosity, however, the flow in the real case is not one-dimensional, and a boundary layer grows in the fluid following the initial shock wave. In this paper simplifying assumptions are made to allow an analysis of the interaction of the shock reflected from the closed end with the boundary layer of the initial shock afterflow. The analysis predicts that interactions of several different types will exist in different ranges of initial shock Mach number. It is shown that the cooling effect of the wall on the afterflow boundary layer accounts for the change in interaction type. An experiment is carried out which verifies the existence of the several interaction regions and shows that they are satisfactorily predicted by the theory. Along with these results, sufficient information is obtained from the experiments to make possible a model for the interaction in the most complicated case. This model is further verified by measurements made during the experiment. The case of interaction with a turbulent boundary layer is also considered. Identifying the type of interaction with the state of turbulence of the interacting boundary layer allows for an estimate of the state of turbulence of the boundary layer based on an experimental investigation of the type of interaction. A method is proposed whereby the effect of the boundary-layer interaction on the strength of the reflected shock may be calculated. The calculation indicates that the reflected shock is rapidly attenuated for a short distance after reflection, and this result compares favorably with available experimental results.

Mark, Herman↗

MARS 2020 Backshell Radiative Heating Measurement and Shock Tube Verification

In February 2021, the Perseverance rover was brought to the surface of Mars by the Mars 2020 mission. A feature of the Mars 2020 capsule was instrumentation to measure its entry, descent and landing (EDL) with the so-called Mars EDL Instrumentation 2 (MEDLI2) [1]. The MEDLI2 introduced, among other things, backshell instrumentation, including a broadband radiometer. The radiometer was mounted on the leeside of the vehicle next to thermocouple plugs and a heat flux gauge. The data returned by the leeside MEDLI2 heat flux gauge is largely analogous to that measured by the COMARS gauge flown on the ExoMars Schiaparelli [2] entry in that it is measuring heat flux in an area that is entirely dominated by radiative heating. The COMARS measurement provided excellent validation of backshell radiative heating models for Mars entry, albeit at a limited number of points [3]. The MEDLI2 heat flux gauge measurement effectively confirmed the quality of the prediction, extended over the full trajectory, as will be presented in this paper. The MEDLI2 radiometer,however, was blocked by ablation products and suffered a loss of half of its signal. The second backshell heat flux gauge installed on the windside of the vehicle was also well predicted, although the heating had both radiative and convective contributions. It was desired to reproduce the conditions of the Mars 2020 entry via ground testing in the Electric Arc Shock Tube (EAST) at NASA Ames. Tests to verify stagnation line heating were previously reported in EAST, confirming the presence of shock layer radiation as the major discrepancy in heatshield temperature modelling [4]. Therefore, tests for stagnation line heating were not repeated. Instead, the shock tube informed bias method [5, 6] was used to identify test conditions that may produce similarity to streamlines that pass around the backside of the vehicle and are responsible for the radiation observed at the two heat flux gauge locations. This method was used to identify a range of velocities and densities in the shock tube that are relevant for confirming the radiative environment encountered. This paper reports the results obtained in the 10 cm diameter EAST shock tube, corresponding to later trajectory points at ambient pressures of 1.1-2.0 Torr and velocities from 1.2-3.5 km/s. The test series employed two primary diagnostics: emission spectroscopy and tunable diode laser absorption spectroscopy (TDLAS). The emission spectroscopy performed broadband measurements of the radiative emission of the 4.3 and 2.7 m bands of CO2 at flight similar conditions, obtaining both spectral and spatial data corresponding to the relaxation behind the shock front. The TDLAS measured the absorption of several lines of CO and CO2 and obtains species number densities and temperatures as a function of time behind the shock front. This paper will review highlights of this test series and analyses of the emission and absorption data. While the datasets generally show good agreement with predictions, a few discrepancies and items for additional investigation are identified and will be discussed

Brett A Cruden↗

Effects of High Fuel Loading and CO2 Dilution on Oxy-Methane Ignition Inside a Shock Tube at High Pressure

Abstract Ignition delay times were measured for methane/O2 mixtures in a high dilution environment of either CO2 or N2 using a shock tube facility. Experiments were performed between 1044 K and 1356 K at pressures near 16 ± 2 atm. Test mixtures had an equivalence ratio of 1.0 with 16.67% CH4, 33.33% O2, and 50% diluent. Ignition delay times were measured using OH* emission and pressure time-histories. Data were compared to the predictions of two literature kinetic mechanisms (ARAMCO MECH 2.0 and GRI Mech 3.0). Most experiments showed inhomogeneous (mild) ignition which was deduced from five time-of-arrival pressure transducers placed along the driven section of the shock tube. Further analysis included determination of blast wave velocities and locations away from the end wall of initial detonations. Blast velocities were 60–80% of CJ-Detonation calculations. A narrow high temperature region within the range was identified as showing homogenous (strong) ignition which showed generally good agreement with model predictions. Model comparisons with mild ignition cases should not be used to further refine kinetic mechanisms, though at these conditions, insight was gained into various ignition behavior. To the best of our knowledge, we present first shock tube data during ignition of high fuel loading CH4/O2 mixtures diluted with CO2 and N2.

Energy & Fuels↗

Characterization of Titan Entry Radiative Heating in the Low Density Electric Arc Shock Tube

Prediction of aftbody radiative heating for Dragonfly’s entry at Titan requires accurate models to inform the design of its thermal protection systems. Previously reported investigations of shock layer aftbody radiation in the Electric Arc Shock Tube (EAST) at NASA Ames Research Center focused on the lower altitude/higher density part of the trajectory. This paper presents the first optical emission spectroscopy measurements of an ongoing test series in the new aluminum Low Density Shock Tube (LDST), recently installed at EAST, focusing on the radiative heating characterization through the higher altitude portion of Dragonfly’s entry path. Experimental data collected at a fill pressure of 0.1 Torr and shock velocities between 5.2 and 6.2 km/s show favorable agreement to similar conditions previously tested in the 4" High-Velocity Shock Tube, as well as improvements in the signal to noise ratio and available test time. Simulations employing DPLR and NEQAIR underpredict the experimental radiance, with increasing discrepancy from the NIR towards the UV wavelength range, thus motivating further efforts in improving the current non-Boltzmann model for the CN molecule.

A Fagnani↗

Full Facility Shock Frame Simulations of the Electric Arc Shock Tube

Radiative heating computations are performed for a range of high speed Earth entry experiments conducted in the Electric Arc Shock Tube at NASA Ames. The nonequilibrium radiative transport equations are solved in NEQAIR using flow field variables from the full facility CFD simulations of the EAST shock tube performed by US3D ow solver. These physics-based flow calculations lead to a significantly different post-shock gas state and associated radiation field as compared to that based on a simplified but computationally inexpensive calculation for flow over a blunt-body with appropriate initial conditions. The radiation spectra and radiance profiles are computed for an extensive range of wavelengths, from deep VUV to IR, which are pertinent to the emission characteristics of high enthalpy shock waves in air. The radiation properties of the shocked gas are calculated both in the nonequilibrium region at the shock, and in the equilibrium region behind the shock. Numerical predictions are found to be consistent with the experimental observations.

Simulations↗

Test section configuration for aerodynamic testing in shock tubes

This paper presents results of a study of the test section configuration required to minimize or alleviate interference effects on model flow produced by the presence of test section walls in the aerodynamic testing of two dimensional transonic airfoils in a shock tube. Tests at a nominal Mach number of 0.85 and a chord Reynolds number of 2,000,000 were carried out by means of schlieren photography and pressure measurements for several symmetric airfoil profiles using shock tube test sections with unmodified straight walls, contoured walls, and slotted walls with adjacent chambers. Results were compared with corresponding results from conventional wind tunnel tests of the airfoils. Results for the straight wall tests show major airfoil flow distortions. Results from contoured wall tests and those performed using a slotted wall test section developed in this study exhibit essential agreement with wind tunnel results. The collective results show that test sections for aerodynamic testing can be designed for shock tubes that will alleviate wall interference effects.

Cook, W. J.↗

A new method to measure homogeneous nucleation rates in shock tubes

The centered expansion wave of a shock tube is utilized to expand and supersaturate a condensable vapor in small concentration in an inert carrier gas. The supersaturated state, located at the rear of the expansion wave, is preserved for a controlled period and then terminated by a recompressing shock wave. During the period of supersaturation, condensation nuclei are formed homogeneously. The nucleation rate is measured as a function of supersaturation by a Mie-light scattering technique. The method is tested using water and the results are compared with classical nucleation theory.

Peters, F.↗