Search NASA⌕ Search

SEARCH · Search NASA

Results for “Shock Tube”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

MARS 2020 Backshell Radiative Heating Measurement and Shock Tube Verification

In February 2021, the Perseverance rover was brought to the surface of Mars by the Mars 2020 mission. A feature of the Mars 2020 capsule was instrumentation to measure its entry, descent and landing (EDL) with the so-called Mars EDL Instrumentation 2 (MEDLI2) [1]. The MEDLI2 introduced, among other things, backshell instrumentation, including a broadband radiometer. The radiometer was mounted on the leeside of the vehicle next to thermocouple plugs and a heat flux gauge. The data returned by the leeside MEDLI2 heat flux gauge is largely analogous to that measured by the COMARS gauge flown on the ExoMars Schiaparelli [2] entry in that it is measuring heat flux in an area that is entirely dominated by radiative heating. The COMARS measurement provided excellent validation of backshell radiative heating models for Mars entry, albeit at a limited number of points [3]. The MEDLI2 heat flux gauge measurement effectively confirmed the quality of the prediction, extended over the full trajectory, as will be presented in this paper. The MEDLI2 radiometer,however, was blocked by ablation products and suffered a loss of half of its signal. The second backshell heat flux gauge installed on the windside of the vehicle was also well predicted, although the heating had both radiative and convective contributions. It was desired to reproduce the conditions of the Mars 2020 entry via ground testing in the Electric Arc Shock Tube (EAST) at NASA Ames. Tests to verify stagnation line heating were previously reported in EAST, confirming the presence of shock layer radiation as the major discrepancy in heatshield temperature modelling [4]. Therefore, tests for stagnation line heating were not repeated. Instead, the shock tube informed bias method [5, 6] was used to identify test conditions that may produce similarity to streamlines that pass around the backside of the vehicle and are responsible for the radiation observed at the two heat flux gauge locations. This method was used to identify a range of velocities and densities in the shock tube that are relevant for confirming the radiative environment encountered. This paper reports the results obtained in the 10 cm diameter EAST shock tube, corresponding to later trajectory points at ambient pressures of 1.1-2.0 Torr and velocities from 1.2-3.5 km/s. The test series employed two primary diagnostics: emission spectroscopy and tunable diode laser absorption spectroscopy (TDLAS). The emission spectroscopy performed broadband measurements of the radiative emission of the 4.3 and 2.7 m bands of CO2 at flight similar conditions, obtaining both spectral and spatial data corresponding to the relaxation behind the shock front. The TDLAS measured the absorption of several lines of CO and CO2 and obtains species number densities and temperatures as a function of time behind the shock front. This paper will review highlights of this test series and analyses of the emission and absorption data. While the datasets generally show good agreement with predictions, a few discrepancies and items for additional investigation are identified and will be discussed

Brett A Cruden↗

Characterization of Titan Entry Radiative Heating in the Low Density Electric Arc Shock Tube

Prediction of aftbody radiative heating for Dragonfly’s entry at Titan requires accurate models to inform the design of its thermal protection systems. Previously reported investigations of shock layer aftbody radiation in the Electric Arc Shock Tube (EAST) at NASA Ames Research Center focused on the lower altitude/higher density part of the trajectory. This paper presents the first optical emission spectroscopy measurements of an ongoing test series in the new aluminum Low Density Shock Tube (LDST), recently installed at EAST, focusing on the radiative heating characterization through the higher altitude portion of Dragonfly’s entry path. Experimental data collected at a fill pressure of 0.1 Torr and shock velocities between 5.2 and 6.2 km/s show favorable agreement to similar conditions previously tested in the 4" High-Velocity Shock Tube, as well as improvements in the signal to noise ratio and available test time. Simulations employing DPLR and NEQAIR underpredict the experimental radiance, with increasing discrepancy from the NIR towards the UV wavelength range, thus motivating further efforts in improving the current non-Boltzmann model for the CN molecule.

A Fagnani↗

Full Facility Shock Frame Simulations of the Electric Arc Shock Tube

Radiative heating computations are performed for a range of high speed Earth entry experiments conducted in the Electric Arc Shock Tube at NASA Ames. The nonequilibrium radiative transport equations are solved in NEQAIR using flow field variables from the full facility CFD simulations of the EAST shock tube performed by US3D ow solver. These physics-based flow calculations lead to a significantly different post-shock gas state and associated radiation field as compared to that based on a simplified but computationally inexpensive calculation for flow over a blunt-body with appropriate initial conditions. The radiation spectra and radiance profiles are computed for an extensive range of wavelengths, from deep VUV to IR, which are pertinent to the emission characteristics of high enthalpy shock waves in air. The radiation properties of the shocked gas are calculated both in the nonequilibrium region at the shock, and in the equilibrium region behind the shock. Numerical predictions are found to be consistent with the experimental observations.

Simulations↗

Test section configuration for aerodynamic testing in shock tubes

This paper presents results of a study of the test section configuration required to minimize or alleviate interference effects on model flow produced by the presence of test section walls in the aerodynamic testing of two dimensional transonic airfoils in a shock tube. Tests at a nominal Mach number of 0.85 and a chord Reynolds number of 2,000,000 were carried out by means of schlieren photography and pressure measurements for several symmetric airfoil profiles using shock tube test sections with unmodified straight walls, contoured walls, and slotted walls with adjacent chambers. Results were compared with corresponding results from conventional wind tunnel tests of the airfoils. Results for the straight wall tests show major airfoil flow distortions. Results from contoured wall tests and those performed using a slotted wall test section developed in this study exhibit essential agreement with wind tunnel results. The collective results show that test sections for aerodynamic testing can be designed for shock tubes that will alleviate wall interference effects.

Cook, W. J.↗

A new method to measure homogeneous nucleation rates in shock tubes

The centered expansion wave of a shock tube is utilized to expand and supersaturate a condensable vapor in small concentration in an inert carrier gas. The supersaturated state, located at the rear of the expansion wave, is preserved for a controlled period and then terminated by a recompressing shock wave. During the period of supersaturation, condensation nuclei are formed homogeneously. The nucleation rate is measured as a function of supersaturation by a Mie-light scattering technique. The method is tested using water and the results are compared with classical nucleation theory.

Peters, F.↗

A Comparison of EAST Shock-Tube Radiation Measurements with a New Air Radiation Model

This paper presents a comparison between the recent EAST shock tube radiation measurements (Grinstead et al., AIAA 2008-1244) and the HARA radiation model. The equilibrium and nonequilibrium radiation measurements are studied for conditions relevant to lunar-return shock-layers; specifically shock velocities ranging from 9 to 11 kilometers per second at initial pressures of 0.1 and 0.3 Torr. The simulated shock-tube flow is assumed one-dimensional and is calculated using the LAURA code, while a detailed nonequilibrium radiation prediction is obtained in an uncoupled manner from the HARA code. The measured and predicted intensities are separated into several spectral ranges to isolate significant spectral features, mainly strong atomic line multiplets. The equations and physical data required for the prediction of these strong atomic lines are reviewed and their uncertainties identified. The 700-1020 nm wavelength range, which accounts for roughly 30% of the radiative flux to a peak-heating lunar return shock-layer, is studied in detail and the measurements and predictions are shown to agree within 15% in equilibrium. The plus or minus 1.5% uncertainty on the measured shock velocity is shown to cause up to a plus or minus 30% difference in the predicted radiation. This band of predictions contains the measured values in almost all cases. For the highly nonequilibrium 0.1 Torr cases, the nonequilibrium radiation peaks are under-predicted by about half. This under-prediction is considered acceptable when compared to the order-of-magnitude over-prediction obtained using a Boltzmann population of electronic states. The reasonable comparison in the nonequilibrium regions provides validation for both the non-Boltzmann modeling in HARA and the thermochemical nonequilibrium modeling in LAURA. The N2 (+)(1-) and N2(2+) molecular band systems are studied in the 290 480 nm wavelength range for both equilibrium and nonequilibrium regimes. The non-Boltzmann rate models for these systems, which have significant uncertainties, are tuned to improve the comparison with measurements.

Johnston, Christopher O.↗

Vacuum Ultraviolet Absorption Measurements of Atomic Oxygen in a Shock Tube

The absorption of vacuum ultraviolet light by atomic oxygen has been measured in the Electric Arc-driven Shock Tube (EAST) Facility at NASA-Ames Research Center. This investigation demonstrates the instrumentation required to determine atomic oxygen concentrations from absorption measurements in impulse facilities. A shock wave dissociates molecular oxygen, producing a high temperature sample of atomic oxygen in the shock tube. A probe beam is generated with a Raman-shifted ArF excimer laser. By suitable tuning of the laser, absorption is measured over a range of wavelengths in the region of the atomic line at 130.49 nm. The line shape function is determined from measurements at atomic oxygen densities of 3x10(exp 17) and 9x10(exp 17) cm(exp -3). The broadening coefficient for resonance interactions is deduced from this data, and this value is in accord with available theoretical models.

Meyer, Scott Andrew↗

Vacuum Ultraviolet Absorption Measurements of Atomic Oxygen in a Shock Tube

The absorption of vacuum ultraviolet light by atomic oxygen has been measured in the Electric Arc-driven Shock Tube (EAST) Facility at NASA-Ames Research Center. This investigation demonstrates the instrumentation required to determine atomic oxygen concentrations from absorption measurements in impulse facilities. A shock wave dissociates molecular oxygen, producing a high temperature sample of atomic oxygen in the shock tube. A probe beam is generated with a Raman-shifted ArF excimer laser. By suitable tuning of the laser, absorption is measured over a range of wavelengths in the region of the atomic line at 130.49 nm. The line shape function is determined from measurements at atomic oxygen densities of 3 x 10(exp 17) and 9 x 10(exp 17) cm(exp -3). The broadening coefficient for resonance interactions is deduced from this data, and this value is in accord with available theoretical models.

Meyer, Scott Andrew↗

Vacuum Ultraviolet Absorption Measurements of Atomic Oxygen in a Shock Tube

The absorption of vacuum ultraviolet light by atomic oxygen has been measured in the Electric Arc-driven Shock Tube (EAST) Facility at NASA-Ames Research Center. This investigation demonstrates the instrumentation required to determine atomic oxygen concentrations from absorption measurements in impulse facilities. A shock wave dissociates molecular oxygen, producing a high temperature sample of atomic oxygen in the shock tube. A probe beam is generated with a Raman-shifted ArF excimer laser. By suitable tuning of the laser, absorption is measured over a range of wavelengths in the region of the atomic line at 130.49 nm. The line shape function is determined from measurements at atomic oxygen densities of 3 x 10(exp 17) and 9 x 10(exp 17)/cu cm. The broadening coefficient for resonance interactions is deduced from this data, and this value is in accord with available theoretical models.

Meyer, Scott Andrew↗

Vibrational and rotational temperature measurements in a shock tube

Vibrational and rotational temperatures in nitrogen test gas relaxing behind a normal shock are measured using the emission spectra of N2(+)(1-) and N2(2+) band systems in an electric-arc driven shock tube, at a shock velocity of 6.2 km/sec. The results are compared with similar data obtained by AVCO-Everett Research Laboratory during the 1960s. The vibrational and rotational temperatures in the equilibrium region obtained in the present experiment agreed with those of AVCO, but those in the nonequilibrium region are greatly different from the AVCO results. The measured rotational temperature seems to be in nonequilibrium with the translational temperature, contradicting the two-temperature model widely used in CFD. Also, the relaxation rates for both N2(+) and N2 molecules seem to be of the same order.

Sharma, S. P.↗

Duplication in a shock tube of stagnation region conditions on a Jovian atmosphere-entry probe

Measurements are presented of the radiative emission from a shock-heated mixture of .85 H2 plus .15 He - the presumed composition of the dominant species in the Jovian atmosphere. The experiments were performed behind the incident wave in a Voitenko-compressor-driven shock tube at shock velocities of 61 and 67 km/sec. Agreement with predictions is good for both radiative emission and radiative cooling.

Compton, D. L.↗

Shock-tube studies of radiative base heating of Jovian probe

A 6.4-cm-diameter scale model of the Jovian entry vehicle is tested in an electric-arc-driven shock tube and a 5-cm-diameter sphere model is tested in a combustion-driven shock tube and in an electric-arc-driven shock tunnel. The radiative heat-transfer rate and pressure on the front and the base regions are measured in the absence of ablation with sensors imbedded in the models in a stream consisting of 10% hydrogen in a bath of either neon or argon. The measured radiative heat-transfer rates and pressures range to about 22 kW/sq cm and 12 atm, respectively, at the front stagnation point. The ratio of the radiative heat-transfer rate at the base stagnation point to that at the front stagnation point is found to be about 1/4 for the sphere at Mach 1.8, about 1/30 for the sphere at Mach 4.8, and about 1/6 for the scale model at Mach 1.7. The present experimental results agree well with the theoretical predictions of Park, thus indicating that Park's theory is valid.

Shirai, H.↗