Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sideband”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

The MRIS feasibility study

The Microwave Reflectometer Ionization Sensor (MRIS) is an instrument being developed for use in detecting and ranging of electron density layers in the reentry plasma of a space transfer vehicle. The rationale for the selection of the Double Sideband Suppressed Carrier (DSBSC) system used in the feasibility study for the MRIS is presented. A 25 GHz single-oscillator system and a 220 GHz double-oscillator system are described. The 25 GHz system was constructed and tested in the laboratory and test results are presented. As developed, the system employs a sideband spacing of 160 MHz. Based on an estimated electromagnetic wave velocity in the plasma, a round-trip phase shift measurement accuracy of +/- 7.6 degrees was required for the desired +/- 1/2 cm distance measurement accuracy. The interaction of parallel ground and reflecting planes produces interference that prevents the basic DSBSC system from meeting the accuracy goal so a frequency modulation was added to the system to allow averaging of the measured phase deviation. With an FM deviation of +/- 1 GHz, laboratory measurements were made for distances from 5 to 61 cm tip free space. Accounting for the plasma velocity factor, 82 percent of the data were equal to or better than the desired accuracy. Based on this measured result a sideband spacing to 250 MHz could be expected to yield data approximately 96 percent within the accuracy goal.

Neece, Robert T.↗

Beat, modulational, and decay instabilities of a circularly polarized Alfven wave

A circulary polarized low-frequency electomagnetic pump wave propoagating along an ambient magnetic field is known to be unstable to the growth of several parallel-propagating parametric instabilties. If ion-cyclotron effects are retained in a two-fluid description, the dispersion relation is a sixth-order polynomial. We present a series of new analytical approximations to this dispersion relation. We emphasize new results for the beat instability that occurs as an interaction of the forward prpagating upper sideband with the backward propagating lower sideband. The nature of the beat instabitlity depends on beta = (v(sub sound)/v(sub A)(exp 2) and on the sense of polarization of the pump wave. The beat and decay instabilities can occur together if the pump is left-handed (i.e., ion resonant) and if beta is less than or approximately 1, but they cannot occur together if the pump is right-handed. For a left-handed pump the beat mode is the only instability if beta is greater than or approximately 1. If the pump is right-handed and beta is greater than or approximately 1, then the beat instability exists only when the pump amplitude exceeds a threshold value, and the beat will be the only instability if the pump amplitude is large enough to stabilize the modulational instability. If the pump is left-handed and beta is less than or approximately 1, then the beat mode is stabilized when the pump amplitude becomes sufficiently large. The beat instability primarily produces a forward propagating transverse wave in the upper sideband. Thus if beta is greater than or approximately 1, the instabilities considered here do not produce the backward propagating waves which are thought to affect turbulence and the evolution of cross helicity in the solar wind. New analytical results are presented also for the decay and modulational instabilites when beta is approximately equal to 1.

Hollweg, Joseph V.↗

An Extremely Wide Bandwidth, Low-Noise SIS Heterodyne Receiver Design for Millimeter and Submillimeter Observations

Millimeter and submillimeter heterodyne receivers using state-of-the-art SIS detectors are capable of extremely large instantaneous bandwidths with noise temperatures within a few Kelvin of the quantum limit. We present the design for a broadband, sensitive, heterodyne spectrometer under development for the Caltech Submillimeter Observatory (CSO). The 180-300 GHz double-sideband design uses a single SIS device excited by a full bandwidth, fixed-tuned waveguide probe on a silicon substrate. The IF output frequency (limited by the MMIC low noise IF preamplifier) is 6-18 GHz, providing an instantaneous RF bandwidth of 24 GHz (double-sideband). The SIS mixer conversion loss should be no more than 1-2 dB with mixer noise temperatures across the band within 10 K of the quantum limit. The single-sideband receiver noise temperature goal is 70 K. The wide instantaneous bandwidth and low noise will result in an instrument capable of a variety of important astrophysical observations beyond the capabilities of current instruments. Lab testing of the receiver will begin in the summer of 2002, and the first use on the CSO should occur in the spring of 2003.

Sumner, Matthew↗

An Extremely Wide Bandwidth, Low Noise SIS Heterodyne Receiver Design for Millimeter and Submillimeter Observations

Our group has designed a heterodyne submillimeter receiver that offers a very wide IF bandwidth of 12 GHz, while still maintaining a low noise temperature. The 180-300 GHz double-sideband design uses a single SI5 device excited by a full bandwidth, fixed-tuned waveguide probe on a silicon substrate. The IF output frequency (limited by the MMIC low noise IF preamplifier) is 6-18 GHz. providing an instantaneous RF bandwidth of 24 GHz (double-sideband). Intensive simulations predict that the junction will achieve a conversion loss better than 1-2 dB and a mixer noise temperature of less than 20 K across the band (twice the quantum limit). The single sideband receiver noise temperature goal is 70 K. The wide instantaneous bandwidth and low noise will result in an instrument capable of a variety of important astrophysical and environmental observations beyond the capabilities of current instruments. Lab testing of the receiver will begin this summer, and first light on the CSO should be in the Spring of 2003. At the CSO, we plan to use receiver with WASP2, a wideband spectrometer, to search for spectral lines from SCUBA sources. This approach should allow us to rapidly develop a catalog of redshifts for these objects.

Zmuidzinas, J.↗

Metrology Camera System Using Two-Color Interferometry

A metrology system that contains no moving parts simultaneously measures the bearings and ranges of multiple reflective targets in its vicinity, enabling determination of the three-dimensional (3D) positions of the targets with submillimeter accuracy. The system combines a direction-measuring metrology camera and an interferometric range-finding subsystem. Because the system is based partly on a prior instrument denoted the Modulation Sideband Technology for Absolute Ranging (MSTAR) sensor and because of its 3D capability, the system is denoted the MSTAR3D. Developed for use in measuring the shape (for the purpose of compensating for distortion) of large structures like radar antennas, it can also be used to measure positions of multiple targets in the course of conventional terrestrial surveying. A diagram of the system is shown in the figure. One of the targets is a reference target having a known, constant distance with respect to the system. The system comprises a laser for generating local and target beams at a carrier frequency; a frequency shifting unit to introduce a frequency shift offset between the target and local beams; a pair of high-speed modulators that apply modulation to the carrier frequency in the local and target beams to produce a series of modulation sidebands, the highspeed modulators having modulation frequencies of FL and FM; a target beam launcher that illuminates the targets with the target beam; optics and a multipixel photodetector; a local beam launcher that launches the local beam towards the multi-pixel photodetector; a mirror for projecting to the optics a portion of the target beam reflected from the targets, the optics being configured to focus the portion of the target beam at the multi-pixel photodetector; and a signal-processing unit connected to the photodetector. The portion of the target beam reflected from the targets produces spots on the multi-pixel photodetector corresponding to the targets, respectively, and the signal-processing unit centroids the spots to determine bearings of the targets, respectively. As the spots oscillate in intensity because they are mixed with the local laser beam that is flood illuminating the focal plane, the phase of oscillation of each spot is measured, the phase of sidebands in the oscillation of each spot being proportional to a distance to the corresponding target relative to the reference target A.

Dubovitsky, Serge↗

Improved phase locked loop receiver

Improved phase locked loop receiver tracks and demodulates a signal whose signal-to-noise ratio may be low and whose information sidebands are close in frequency. This receiver recovers the carrier from input signals and applies it to a demodulator which recovers the sidebands.

Daley, T. J.↗

Tracking a phase-shift-keyed signal

In detector, phase shifter is used to generate negative phase shift opposing detected phase angle. This produces converted series sideband and component carrier, with residual carrier signal and converted series sideband and component carrier added together to produce tracking signal.

Villarreal, S.↗

Theory of type 3b solar radio bursts

During the initial space-time evolution of an electron beam injected into the corona, the strong beam-plasma interaction occurs at the head of the beam, leading to the amplification of a quasi-monochromatic large-amplitude plasma wave that stabilizes by trapping the beam particles. Oscillation of the trapped particles in the wave troughs amplifies sideband electrostatic waves. The sidebands and the main wave subsequently decay to observable transverse electromagnetic waves through the parametric decay instability. This process gives rise to the elementary striation bursts. Owing to velocity dispersion in the beam and the density gradient of the corona, the entire process may repeat at a finite number of discrete plasma levels, producing chains of elementary bursts. All the properties of the type IIIb bursts are accounted for in the context of the theory.

Smith, R. A.↗

Theory of type IIIb solar radio bursts

During the initial space-time evolution of an electron beam injected into the corona, the strong beam-plasma interaction occurs at the head of the beam, leading to the amplification of a quasi-monochromatic large-amplitude plasma wave that stabilizes by trapping the beam particles. Oscillation of the trapped particles in the wave troughs amplifies sideband electrostatic waves. The sidebands and the main wave subsequently decay to observable transverse electromagnetic waves through the parametric decay instability. This process gives rise to the elementary striation bursts. Owing to velocity dispersion in the beam and the density gradient of the corona, the entire process may repeat at a finite number of discrete plasma levels, producing chains of elementary bursts. All the properties of the type IIIb bursts are accounted for in the context of the theory.

Smith, R. A.↗

A 230-GHz radiometer system employing a second-harmonic mixer

A radiometer system for use in the 1.3 mm region has been constructed and used for radio astronomical observations. A second-harmonic mixer employing a single Schottky diode downconverts the incident power to an IF frequency of about 1400 MHz. The measured double-sideband system noise temperature is 6000 K (noise figure = 13 dB) and the double-sideband mixer conversion loss is calculated to be 10 dB. The mixer is tunable over a range of at least 15 GHz.

Goldsmith, P. F.↗

Stratospheric ozone measurement with an infrared heterodyne spectrometer

Measurements of a stratospheric ozone concentration profile are made by detecting infrared absorption lines with a heterodyne spectrometer. The infrared spectrometer is based on a line-by-line tunable CO2 lasers, a liquid-nitrogen cooled HgCdTe photomixer, and a 64-channel spectral line receiver. The infrared radiation from the source is mixed with local-oscillator radiation. The difference frequency signal in a bandwidth above and below the local-oscillator frequency is detected. The intensity in each sideband is found by subtracting sideband contributions. It is found that absolute total column density is 0.32 plus or minus 0.02 cm-atm with a peak mixing ratio at about 24 km. The (7,1,6)-(7,1,7) O3 line center frequency is identified as 1043.1772/cm. Future work will involve a number of ozone absorption lines and measurements of diurnal variation. Completely resolved stratospheric lines may be inverted to yield concentration profiles of trace constituents and stratospheric gases.

Abbas, M. M.↗

Low-noise Josephson mixers at 115 GHz using recyclable point contacts

Thermally recyclable Nb point-contact Josephson junctions are investigated as low-noise mixers with an external local oscillator at 115 GHz. The best single sideband mixer noise temperature achieved is 140 (+ or - 20) K with a single sideband conversion loss of 2.4 (+ or - 0.5) dB. Such rugged junctions are suitable for use in practical receivers and should give unprecedented sensitivity at the shorter millimeter wavelengths.

Taur, Y.↗

Method and apparatus for receiving and tracking phase modulated signals

An apparatus and technique are described for receiving and tracking analog or digital phase modulated signals from 0 deg to 360 deg phase shift. In order to track a signal with many phases, a detector discerns the phase modulation of the incoming signal and a phase shifter generates a negative phase shift opposite in angle to the detected phase angle. This produces a converted series sideband component barrier signal. The residual carrier signal and the converted series sideband component carrier are added together to produce a tracking carrier signal. The tracking carrier signal is multiplied with the output from a voltage controlled oscillator in the tracking loop to obtain an error signal which drives the voltage controlled oscillator and tracks the incoming signal frequency. The technique is less susceptible to carrier interference which may degrade tracking and tracking may be performed at lower signal to noise ratios and for lower input signal power levels.

Villarreal, S.↗

Low-noise 115-GHz receiver using superconducting tunnel junctions

A 110-118-GHz receiver based on a superconducting quasiparticle tunnel junction mixer is described. The single-sideband noise temperature is as low as 68 + or - 3 K. This is nearly twice the sensitivity of any other receiver at this frequency. The receiver was designed using a low-frequency scale model in conjunction with the quantum mixer theory. A scaled version of the receiver for operation at 46 GHz has a single-sideband noise temperature of 55 K. The factors leading to the success of this design are discussed.

Pan, S.-K.↗

Advanced infrared laser modulator development

A parametric study was conducted to develop an electrooptic waveguide modulator for generating continuous tunable sideband power from an infrared CO2 laser. Parameters included were the waveguide configurations, microstrip dimensions device impedance, and effective dielectric constants. An optimum infrared laser modulator was established and was fabricated. This modulator represents the state-of-the-art integrated optical device, which has a three-dimensional topology to accommodate three lambda/4 step transformers for microwave impedance matching at both the input and output terminals. A flat frequency response of the device over 20 HGz or = 3 dB) was achieved. Maximum single sideband to carrier power greater than 1.2% for 20 W microwave input power at optical carrier wavelength of 10.6 microns was obtained.

Cheo, P. K.↗

Stimulated scattering instability of lower hybrid waves

The excitation of a low-frequency quasi-mode together with two lower hybrid sidebands by a lower hybrid pump is analyzed for laboratory plasmas. This instability is excited in a narrow spectral range around the scale length of the quasi-mode which is about half the pump wavelength. The growth rates are of order of the ion cyclotron frequency. This instability can modify the intensity distribution of the pump wave and as a consequence affect the energy deposition of the pump wave in plasmas. The smaller parallel phase velocities of the forwardscattered lower hybrid sidebands are conducive to the acceleration of bulk electrons along the magnetic field.

Kuo, S. P.↗

Dual-pilot tone calibration technique

Pilot-based calibration techniques are used to reduce the effects of multipath fading in mobile satellite receivers. One of the more recent of these techniques, namely the tone calibration technique (TCT), suggests transmitting double sideband modulation with the pilot tone located at the center of its spectrum where the amplitude and phase characteristics of the channel are most stable. To 'make room' for the pilot in the presence of the Doppler shift, the equivalent low-pass data sidebands must be shaped so as to have zero response in the neighborhood of dc. Other techniques such as transparent tone-in-band (TTIB) similarly 'notch out' a hole in the center of the data spectrum for location of the pilot. An alternate possibility which is at the same time much more bandwidth efficient than TCT is a dual-pilot tone calibration technique (DPTCT) that symmetrically locates a pair of pilots outside the data spectrum near the band edges of the channel. The operation and performance of DPTCT are analyzed, and its effectiveness is compared to that of the single tone TCT technique.

Simon, Marvin K.↗