Hybrid Detector (Final Technical Report)

We report updates since the first demonstration of a phonon-mediated silicon detector technology that provides a primary phonon measurement in a low-voltage region, and a simultaneous indirect measurement of the ionization signal through Neganov–Trofimov–Luke amplification in a high voltage region, both in a monolithic crystal. We present characterization of charge and phonon transport between the two stages of the detector and the resulting background discrimination capability at low energies. This new detector technology has the potential to significantly enhance the sensitivity of dark matter and coherent neutrino scattering experiments beyond the capabilities of current technologies that have limited discrimination at low energies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Toward Trustworthy Detectors Detector Characterization for SuperCDMS SNOLAB Commissioning

SuperCDMS SNOLAB is a next generation direct detection experiment searching for low mass dark matter using cryogenic germanium and silicon detectors operated at millikelvin temperatures. As commissioning begins, establishing stable, predictable detector response to energy deposits is a prerequisite for future physics analysis. This work studies detector stability and calibration for four SuperCDMS SNOLAB detectors, det 7 and det 15 (germanium) and det 11 and det 14 (silicon), using Barium-133 calibration data (356 keV gamma ray reference) and low background data (ambient radiation, no external source). The Ba-133 data show no distinct line at the expected energy, and the low background data show a baseline that drifts and oscillates rather than remaining flat, consistently across multiple channels, suggesting a shared, detector wide cause. These observations point to the cryogenic support system as the likely source, since small temperature fluctuations could couple into the temperature sensitive detectors, informing the ongoing commissioning effort.

O'Hanlon, Vika [Skidmore Coll.]↗

Electrical performances of pre-production staves for the ATLAS ITk Strip Detector Upgrade

The ATLAS experiment is currently preparing for an upgrade of the inner tracking detector for the High-Luminosity LHC. The new tracker, ITk, employs an all-silicon detector with outer strip layers. The building block of the ITk strip barrel is the stave which consists of a low-mass support structure hosting the common electrical, optical and cooling services as well as 28 silicon modules. In this contribution, we outline the challenging aspects of the stave pre-production testing phase at Brookhaven National Laboratory. Here, the electrical characterization of these staves, hosting the final design of all ASICs, will be discussed in detail.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detector Characterization for SuperCDMS Commissioning

Super Cryogenic Dark Matter Search (SuperCDMS) SNOLAB is a next generation direct detection experiment search ing for low mass dark matter using cryogenic germanium and silicon detectors operated at millikelvin temperatures. As the experiment begins its first commissioning data taking, establishing that the detectors respond to energy deposits in a stable, predictable way is a prerequisite for any future physics analysis. This work presents a study of detector stability for four SuperCDMS SNOLAB detectors, det 7 and det 15 (germanium), and det 11 and det 14 (silicon), using two data sets taken during early commissioning: dedicated Barium-133 calibration runs, which provide a known gamma ray energy reference at 356 keV, and low background runs, which record whatever background radiation the detectors see with no external source present. The Ba-133 data do not show a distinct, well localized line at the expected energy, and the low background data show a baseline that drifts and oscillates over time rather than remaining flat. This baseline instability appears consistently across multiple channels rather than being confined to one, suggesting a shared, detector wide cause rather than a single faulty channel. Together, these observations point to the detectors’ cryogenic support system as the likely source of the instability, since small temperature fluctuations introduced during normal operation of the cooling system could plausibly couple into the exquisitely temperature sensitive detectors. These results inform the ongoing commissioning effort by narrowing down where instability in the current data is originating from.

O'Hanlon, Viktoria M. [Skidmore Coll.; Fermilab]↗

Detector Characterization for SuperCDMS Commissioning

Super Cryogenic Dark Matter Search (SuperCDMS) SNOLAB is a next generation direct detection experiment search ing for low mass dark matter using cryogenic germanium and silicon detectors operated at millikelvin temperatures. As the experiment begins its first commissioning data taking, establishing that the detectors respond to energy deposits in a stable, predictable way is a prerequisite for any future physics analysis. This work presents a study of detector stability for four SuperCDMS SNOLAB detectors, det 7 and det 15 (germanium), and det 11 and det 14 (silicon), using two data sets taken during early commissioning: dedicated Barium-133 calibration runs, which provide a known gamma ray energy reference at 356 keV, and low background runs, which record whatever background radiation the detectors see with no external source present. The Ba-133 data do not show a distinct, well localized line at the expected energy, and the low background data show a baseline that drifts and oscillates over time rather than remaining flat. This baseline instability appears consistently across multiple channels rather than being confined to one, suggesting a shared, detector wide cause rather than a single faulty channel. Together, these observations point to the detectors’ cryogenic support system as the likely source of the instability, since small temperature fluctuations introduced during normal operation of the cooling system could plausibly couple into the exquisitely temperature sensitive detectors. These results inform the ongoing commissioning effort by narrowing down where instability in the current data is originating from.

O'Hanlon, Viktoria M. [Skidmore Coll.; Fermilab]↗

Sensitive photodetection below silicon bandgap using quinoid-capped organic semiconductors

High-sensitivity organic photodetectors (OPDs) with strong near-infrared (NIR) photoresponse have attracted enormous attention due to potential applications in emerging technologies. However, few organic semiconductors have been reported with photoelectric response beyond ~1.1 μm, the detection limit of silicon detectors. Here, we extend the absorption of organic small-molecule semiconductors to below silicon bandgap, and even to 0.77 eV, through introducing the newly designed quinoid-terminals with high Mulliken-electronegativity (5.62 eV). The fabricated photodiode-type NIR OPDs exhibit detectivity (D*) over 10 12 Jones in 0.41 to 1.2 μm under zero bias with a maximum of 2.9 × 10 12 Jones at 1.02 μm, which is the highest D* for reported OPDs in photovoltaic-mode with response spectra beyond 1.1 μm. The high D* in 0.9 to 1.2 μm is comparable to those of commercial InGaAs photodetectors, despite the detection limit of our OPDs is shorter than InGaAs (~1.7 μm). A spectrometer prototype with a wide measurable region (0.4 to 1.25 μm) and NIR imaging under 1.2-μm illumination are demonstrated successfully in OPDs.

36 MATERIALS SCIENCE↗

Design and performance of the Fermilab Constant Fraction Discriminator ASIC

Here, we present the design and performance characterization results of the novel Fermilab Constant Fraction Discriminator ASIC (FCFD) developed to readout low gain avalanche detector (LGAD) signals by directly using a constant fraction discriminator (CFD) to measure signal arrival time. Silicon detectors with time resolutions less than 30ps will play a critical role in future collider experiments, and LGADs have been demonstrated to provide the required time resolution and radiation tolerance for many such applications. The FCFD has a specially designed discriminator that is robust against amplitude variations of the signal from the LGAD that normally requires an additional correction step when using a traditional leading edge discriminator. The application of the CFD directly in the ASIC promises to be more reliable and reduces the complication of evolving time-walk corrections throughout the operational lifetime of the detector system. We will present a summary of the measured performance of the FCFD for input signals generated by internal charge injection, LGAD signals from an infrared laser, and LGAD signals from minimum-ionizing particles. The mean time response for LGAD signals with charge ranging between 5 and 26 fC has been measured to vary no more than 10ps, orders of magnitude more stable than an uncorrected leading edge discriminator based measurement, and effectively removes the need for any additional time-walk correction. The measured contribution to the time resolution from the FCFD ASIC is found to be 10ps for signals with charge above 20fC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A method for estimating light quenching in inorganic scintillator detectors for radioactive ion beam experiments

In recent experiments, inorganic scintillators have been used to study the decays of exotic nuclei, providing an alternative to silicon detectors and enabling measurements that were previously impossible. However, proper use of these materials requires us to understand and quantify the scintillation process, specifically in response to very heavy nuclei. Here, in this work, we show a simplified method based on the models of Birks (1951) and Meyer and Murray (1962) to parametrize the light output of inorganic scintillators in response to beams of energetic heavy ions over a broad range of energies. We test the accuracy of our parametrization approach by calculating light output and quenching factors for various ions and comparing them with experimental data from Lutetium Yttrium Orthosilicate (LYSO:Ce), a common inorganic scintillator. The Meyer–Murray model suggests that, for sufficiently heavy ions at high energies, the majority of the light output is associated with the creation of delta electrons, which are induced by the passage of the beam through the material. These delta electrons dramatically impact the response of detection systems when subject to ions with velocities typical of beams in modern fragmentation facilities. To illustrate this, we also present a qualitative estimate of the effects of delta rays on overall light output using the Birks–Meyer–Murray parametrization. The approach presented herein will serve as a basic framework for further, more rigorous studies of scintillator response to heavy ions. This work is a crucial first step in planning future experiments where energetic exotic nuclei are interacting with scintillator detectors.

Heavy ion↗

Phonon-mediated high-voltage detector with background rejection for low-mass dark matter and reactor coherent neutrino scattering experiments

We report the first demonstration of a phonon-mediated silicon detector technology that provides a primary phonon measurement in a low-voltage region, and a simultaneous indirect measurement of the ionization signal through Neganov-Trofimov-Luke amplification in a high voltage region, both in a monolithic crystal. We present characterization of charge and phonon transport between the two stages of the detector and the resulting background discrimination capability at low energies. Furthermore, this new detector technology has the potential to significantly enhance the sensitivity of dark matter and coherent neutrino scattering experiments beyond the capabilities of current technologies that have limited discrimination at low energies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for Magnetic Monopole Pair Production in Ultraperipheral Pb + Pb Collisions at s NN = 5.36 TeV with the ATLAS Detector at the LHC

This Letter presents a search for highly ionizing magnetic monopoles in 262 μ b − 1 of ultraperipheral Pb + Pb collision data at s NN = 5.36 TeV collected by the ATLAS detector at the LHC. A new methodology that exploits the properties of clusters of hits reconstructed in the innermost silicon detector layers is introduced to study highly ionizing particles in heavy-ion data. No significant excess above the background, which is estimated using a data-driven technique, is observed. Using a nonperturbative semiclassical model, upper limits at 95% confidence level are set on the cross section for pair production of monopoles with a single Dirac magnetic charge in the mass range of 20–150 GeV. Depending on the model, monopoles with a single Dirac magnetic charge and mass below 80–120 GeV are excluded. © 2025 CERN, for the ATLAS Collaboration 2025 CERN

Aad, G. (ORCID:0000000266654934)↗

Even lighter particle dark matter

We report on recent progress in the search for dark matter particles with masses from 1 Mev c ^{-2} − 2 to 1 Gev c ^{-2} − 2 . Several dark matter candidates in this mass range are expected to generate measurable electronic-recoil signals in direct-detection experiments. We focus on dark matter particles scattering with electrons in semiconductor detectors since they have fundamentally the highest sensitivity due to their low ionization threshold. Charge-coupled device (CCD) silicon detectors are the leading technology, with significant progress expected in the coming years. We present the status of the CCD program and briefly report on other efforts.

Chavarria, Alvaro E.↗

Building the Eyes of Discovery

My presentation focuses on the development and enhancement of sensor modules that help particle detectors “see” particles invisible to the human eye, specifically the Compact Muon Shield detector, which is part of the High-Luminosity Large Hadron Collider. As a CCI intern at Fermilab’s Silicon Detector Facility, I worked on testing and visual inspection of different module parts before assembly and on testing the modules after assembly. My talk highlights how small sensors carry the capability to collect tiny particle signals within the detector and the reliability of control checks pre-assembly for scientists to produce reliable data for future discoveries.

Siddiqui, Hooriya [Fermilab] (ORCID:00090001510973↗

Ionization Yield in Silicon for eV-Scale Electron-Recoil Processes

The development of single charge resolving, macroscopic silicon detectors has opened a window into rare processes at the O(eV) scale. In order to reconstruct the energy of a given event, or model the charge signal obtained for a given amount of energy absorbed by the electrons in a detector, an accurate charge yield model is needed. In this paper we review existing measurements of charge yield in Silicon, focusing in particular on the region below 1 keV. We highlight a calibration gap between 12-50 eV (referred to as the "UV-gap") and employ a phenomenological model of impact ionization to explore the likely charge yield in this energy regime. Finally, we explore the impact of variations in this model on a test case, that of dark matter scattering off electrons, to illustrate the scientific impact of uncertainties in charge yield.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulating 50 keV X-ray Photon Detection in Silicon with a Down-Conversion Layer

Simulation results are presented that explore an innovative, new design for X-ray detection in the 20–50 keV range that is an alternative to traditional direct and indirect detection methods. Typical indirect detection using a scintillator must trade-off between absorption efficiency and spatial resolution. With a high-Z layer that down-converts incident photons on top of a silicon detector, this design has increased absorption efficiency without sacrificing spatial resolution. Simulation results elucidate the relationship between the thickness of each layer and the number of photoelectrons generated. Further, the physics behind the production of electron-hole pairs in the silicon layer is studied via a second model to shed more light on the detector’s functionality. Together, the two models provide a greater understanding of this detector and reveal the potential of this novel form of X-ray detection.

47 OTHER INSTRUMENTATION↗

The DAQ system of the 12,000 channel CMS high granularity calorimeter prototype

The CMS experiment at the CERN LHC will be upgraded to accommodate the 5-fold increase in the instantaneous luminosity expected at the High-Luminosity LHC (HL-LHC). Concomitant with this increase will be an increase in the number of interactions in each bunch crossing and a significant increase in the total ionising dose and fluence. One part of this upgrade is the replacement of the current endcap calorimeters with a high granularity sampling calorimeter equipped with silicon sensors, designed to manage the high collision rates. As part of the development of this calorimeter, a series of beam tests have been conducted with different sampling configurations using prototype segmented silicon detectors. In the most recent of these tests, conducted in late 2018 at the CERN SPS, the performance of a prototype calorimeter equipped with ≈12,000 channels of silicon sensors was studied with beams of high-energy electrons, pions and muons. This paper describes the custom-built scalable data acquisition system that was built with readily available FPGA mezzanines and low-cost Raspberry Pi computers.

47 OTHER INSTRUMENTATION↗

Direct cross section measurement of 102 Pd ⁢(𝛾,𝑝) and 102 Pd ⁢(𝛾,𝛼) for the astrophysical 𝑝 process

Background: A handful of neutron-deficient stable nuclei, known as the “p nuclei,” cannot be produced through astrophysical neutron capture processes. Instead, some of these nuclei are proposed to be produced by 𝛾-induced reactions on existing r- and s-process seeds. The specific astrophysical site or sites are not yet identified, however, with uncertainties in the cross sections of these 𝛾-induced reactions playing a role. Databases of reaction rates for astrophysical simulations often rely on theoretical statistical model calculations, such as Hauser-Feshbach, for rates where no experimental information is known. However, reasonable variations in the choice of parametrizations of various nuclear properties can create order-of-magnitude variations in the final predicted cross sections and reaction rates, which are then propagated through the models to the predicted final abundances. Purpose: To better constrain these statistical model calculations and ultimately reduce the uncertainties from the nuclear physics on our understanding of the p nuclei, a measurement of the cross sections of 𝛾-induced reactions on the p-nucleus 102 Pd was undertaken. This work represents the first measurement of its kind, using segmented silicon detectors to measure prompt charged particle emission from 𝛾-induced reactions. Methods: Quasimonoenergetic gamma beams from the High Intensity 𝛾 Source facility bombarded an enriched 102 Pd target. A segmented silicon array was arranged to detect the particles emitted from (𝛾,𝑝) and (𝛾,𝛼) reactions. Results: Reaction cross sections were deduced at multiple 𝛾-beam energies between 10 and 19 MeV, and compared to statistical model calculations using talys-1.96. The 102 Pd ⁢(𝛾,𝑝)⁢ 101 Rh reaction cross section was reasonably well reproduced by a subset of photon strength functions and level densities, though the strength to the ground state of 101 Rh was underestimated at higher incident gamma energies. The 102 Pd ⁢(𝛾,𝛼)⁢ 98 Ru was in general overpredicted by the various alpha-nucleus optical model potentials. Conclusions: While the theoretical cross sections used to model the (𝛾,𝑝) reactions for the p process may be reasonable, a more careful approach is needed in the case of (𝛾,𝛼). Further work to probe gamma-induced reaction cross sections at and near the p nuclei is warranted.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Performance of the Particle-Identification Silicon-Telescope Array coupled with the VAMOS++ magnetic spectrometer

The Particle-Identification Silicon-Telescope Array (PISTA) is a new detection system designed for high-resolution studies of fission process induced by multi-nucleon transfer in inverse kinematics. It is specifically optimized for experiments with the VAMOS++ magnetic spectrometer at GANIL (Grand Accélérateur National d’Ions Lourds). The array comprises eight trapezoidal ΔE-E silicon telescopes arranged in a lamp shade configuration. Each telescope integrates two single-sided stripped silicon detectors, enabling target-like recoil identification, energy loss measurements, and trajectory reconstruction. Positioned in close proximity to the target, PISTA’s compact geometry achieves high-efficiency tracking of target-like recoils produced in multi-nucleon transfer reactions at Coulomb barrier energies. The spatial segmentation of the array allows precise determination of the mass and charge of the target-like nucleus, and excitation energy of fissioning systems. This work presents the particle identification and excitation energy reconstruction performances for the interactions of 238 U beam with 12 C target. An excitation energy resolution of 800 keV (FWHM) was determined together with mass resolution of 1.1% (FWHM). The combination of PISTA and VAMOS++ magnetic spectrometer enables unprecedented investigations of the fission process as a function of the excitation energy of the fissioning nucleus, particularly for exotic systems produced in transfer-induced reactions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Synchrotron-based Characterization Techniques for Radiation Detection Materials and Devices: An Overview

High-performance room-temperature radiation detectors (high energy resolution for spectrometers, high spatial resolution for imaging devices, and low defect-density for high flux applications) are needed for photon energies (>20 keV) that are not well suited for silicon detectors. Applications for such radiation detectors include nonproliferation, synchrotron, medical, astrophysics, and homeland security. Material- and device- characterization to understand and solve the limiting factors of radiation detection materials and devices is a core element of a radiation detector development R&D program. This presentation will give an overview on the two main synchrotron-based characterization techniques that have been employed by the authors in the last ~20 years: (1) White Beam X-ray Diffraction Topography and (2) Micron-scale detector mapping. A perfect (one domain) crystal (radiation detection material) is a requirement to achieve a highperformance radiation detector. White Beam X-ray Diffraction Topography (WBXDT) allows the rapid screening of the crystallinity of the detector material. With WBXDT we can quickly screen CZT and other crystals to make sure they have only one domain, and to see the presence of extended defects and strain fields.

Camarda, Giuseppe S.↗