Search NASA⌕ Search

SEARCH · Search NASA

Results for “Simulation Radiological Data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

A Technique for Generating Volumetric Cine-Magnetic Resonance Imaging

Purpose: The purpose of this study was to develop a techique to generate on-board volumetric cine-magnetic resonance imaging (VC-MRI) using patient prior images, motion modeling, and on-board 2-dimensional cine MRI. Methods and Materials: One phase of a 4-dimensional MRI acquired during patient simulation is used as patient prior images. Three major respiratory deformation patterns of the patient are extracted from 4-dimensional MRI based on principal-component analysis. The on-board VC-MRI at any instant is considered as a deformation of the prior MRI. The deformation field is represented as a linear combination of the 3 major deformation patterns. The coefficients of the deformation patterns are solved by the data fidelity constraint using the acquired on-board single 2-dimensional cine MRI. The method was evaluated using both digital extended-cardiac torso (XCAT) simulation of lung cancer patients and MRI data from 4 real liver cancer patients. The accuracy of the estimated VC-MRI was quantitatively evaluated using volume-percent-difference (VPD), center-of-mass-shift (COMS), and target tracking errors. Effects of acquisition orientation, region-of-interest (ROI) selection, patient breathing pattern change, and noise on the estimation accuracy were also evaluated. Results: Image subtraction of ground-truth with estimated on-board VC-MRI shows fewer differences than image subtraction of ground-truth with prior image. Agreement between normalized profiles in the estimated and ground-truth VC-MRI was achieved with less than 6% error for both XCAT and patient data. Among all XCAT scenarios, the VPD between ground-truth and estimated lesion volumes was, on average, 8.43 ± 1.52% and the COMS was, on average, 0.93 ± 0.58 mm across all time steps for estimation based on the ROI region in the sagittal cine images. Matching to ROI in the sagittal view achieved better accuracy when there was substantial breathing pattern change. The technique was robust against noise levels up to SNR = 20. For patient data, average tracking errors were less than 2 mm in all directions for all patients. Conclusions: Preliminary studies demonstrated the feasibility of generating real-time VC-MRI for on-board localization of moving targets in radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

UAVs for Radiological Monitoring: Determining Ideal Operational Parameters From GEANT4 Simulations - 18025

Owing in no small part to the enormous advances in radiation detector technology (size, sensitivity and spectral-resolution), there has been an increased drive and requirement to accurately map both the spatial extent and magnitude of radiological contamination at the greatest possible spatial resolutions. To undertake this, a range of different methods have been devised and include the use of cars and human, but also planes (and more recently) unmanned aerial vehicles (UAVs). However, critical to the remote sensing using such UAVs in contrast to ground-based sensing, is (i) the selection of the ideal operational parameters to attain the best on-ground resolution in addition to, (ii) understanding the correct normalisation procedures and other influences on results that surveys at these reduced altitudes might present. Resulting from earlier works, through employing combined modelling and experimental data, the optimal height for a UAV survey using the more realistic 'area' radioactive source term (opposed to an infinitely-small 'point-source') is determined to be approximately 5 m - suitably maximizing cross detector counts. At greater altitudes than this, the influence of variations in neighboring topology / topography and nearby structures are observed to be negligible. However, at this and further-reduced altitudes (where optimal count-rates exists), small height-related variations are observed to result, and impact considerably on the complexity of the data normalisation. Whilst not occurring as a tool to entirely replace ground-based surveys, UAV systems are able to perform in challenging or dangerous environments, inadvisable or problematic to send humans. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

RADAI: A Large-Scale Realistic Dataset for Radiation Detection Algorithm Development

Open, realistic datasets are essential for developing and benchmarking radiation detection algorithms, yet they remain scarce. The Radiological Anomaly Detection and Identification (RADAI) project was develop to create datasets that meet the training and testing needs for sophisticated radiation detection algorithms. The RADAI dataset is a large-scale synthetic resource that integrates high-fidelity Monte Carlo simulations with realistic urban scenarios to capture both background variability and source signatures. RADAI models construction-material NORM, people and vehicles, urban clutter, and dynamic environmental effects such as cosmic-ray and rain-induced transients, and they provide list-mode detector data with motion and response modeling suitable for algorithm training and evaluation. The RADAI project resulted in three publicly-released complementary datasets together with an online scoring portal for standardized performance assessment and an open software toolkit that supports data access, augmentation, model development, and evaluation. These resources enable reproducible comparisons across methods and promote rigorous studies at the scale required by contemporary machine learning. By grounding algorithm development in realistic, well-documented conditions, RADAI supports progress toward more robust detection, identification, and localization in complex urban environments.

Ghawaly, James M. [Division of Computer Science an↗

Evaluating Machine Learning-Based MRI Reconstruction Using Digital Image Quality Phantoms

Quantitative and objective evaluation tools are essential for assessing the performance of machine learning (ML)-based magnetic resonance imaging (MRI) reconstruction methods. However, the commonly used fidelity metrics, such as mean squared error (MSE), structural similarity (SSIM), and peak signal-to-noise ratio (PSNR), often fail to capture fundamental and clinically relevant MR image quality aspects. To address this, we propose evaluation of ML-based MRI reconstruction using digital image quality phantoms and automated evaluation methods. Our phantoms are based upon the American College of Radiology (ACR) large physical phantom but created in k-space to simulate their MR images, and they can vary in object size, signal-to-noise ratio, resolution, and image contrast. Our evaluation pipeline incorporates evaluation metrics of geometric accuracy, intensity uniformity, percentage ghosting, sharpness, signal-to-noise ratio, resolution, and low-contrast detectability. We demonstrate the utility of our proposed pipeline by assessing an example ML-based reconstruction model across various training and testing scenarios. The performance results indicate that training data acquired with a lower undersampling factor and coils of larger anatomical coverage yield a better performing model. The comprehensive and standardized pipeline introduced in this study can help to facilitate a better understanding of the performance and guide future development and advancement of ML-based reconstruction algorithms.

47 OTHER INSTRUMENTATION↗

Development of computational small animal models and their applications in preclinical imaging and therapy research

The development of multimodality preclinical imaging techniques and the rapid growth of realistic computer simulation tools have promoted the construction and application of computational laboratory animal models in preclinical research. Since the early 1990s, over 120 realistic computational animal models have been reported in the literature and used as surrogates to characterize the anatomy of actual animals for the simulation of preclinical studies involving the use of bioluminescence tomography, fluorescence molecular tomography, positron emission tomography, single-photon emission computed tomography, microcomputed tomography, magnetic resonance imaging, and optical imaging. Other applications include electromagnetic field simulation, ionizing and nonionizing radiation dosimetry, and the development and evaluation of new methodologies for multimodality image coregistration, segmentation, and reconstruction of small animal images. This paper provides a comprehensive review of the history and fundamental technologies used for the development of computational small animal models with a particular focus on their application in preclinical imaging as well as nonionizing and ionizing radiation dosimetry calculations. An overview of the overall process involved in the design of these models, including the fundamental elements used for the construction of different types of computational models, the identification of original anatomical data, the simulation tools used for solving various computational problems, and the applications of computational animal models in preclinical research. The authors also analyze the characteristics of categories of computational models (stylized, voxel-based, and boundary representation) and discuss the technical challenges faced at the present time as well as research needs in the future.

61 RADIATION PROTECTION AND DOSIMETRY↗

Induced Radioactivity in Lead Shielding at the National Synchrotron Light Source

The National Synchrotron Light Source (NSLS) at Brookhaven National Laboratory was shut down in September 2014. Lead bricks used as radiological shadow shielding within the accelerator were exposed to stray radiation fields during normal operations. The FLUKA code, a fully integrated Monte Carlo simulation package for the interaction and transport of particles and nuclei in matter, was used to estimate induced radioactivity in this shielding and stainless steel beam pipe from known beam losses. The FLUKA output was processed using MICROSHIELD® to estimate on-contact exposure rates with individually exposed bricks to help design and optimize the radiological survey process. This entire process can be modeled using FLUKA, but use of MICROSHIELD® as a secondary method was chosen because of the project’s resource constraints. Due to the compressed schedule and lack of shielding configuration data, simple FLUKA models were developed in this paper. FLUKA activity estimates for stainless steel were compared with sampling data to validate results, which show that simple FLUKA models and irradiation geometries can be used to predict radioactivity inventories accurately in exposed materials. During decommissioning 0.1% of the lead bricks were found to have measurable levels of induced radioactivity. Finally, post-processing with MICROSHIELD® provides an acceptable secondary method of estimating residual exposure rates.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

SU-D-209-05: Sensitivity of the Diagnostic Radiological Index of Protection (DRIP) to Procedural Factors in Fluoroscopy

Purpose: To evaluate the sensitivity of the Diagnostic Radiological Index of Protection (DRIP) to procedural factors in fluoroscopy in an effort to determine an appropriate set of scatter-mimicking primary beams (SMPB) to be used in measuring the DRIP. Methods: A series of clinical and factorial Monte Carlo simulations were conducted to determine the shape of the scattered X-ray spectra incident on the operator in different clinical fluoroscopy scenarios. Two clinical evaluations studied the sensitivity of the scattered spectrum to gantry angle and patient size while technical factors were varied according to measured automatic dose rate control (ADRC) data. Factorial evaluations studied the sensitivity of the scattered spectrum to gantry angle, field of view, patient size and beam quality for constant technical factors. Average energy was the figure of merit used to condense fluence in each energy bin to a single numerical index. Results: Beam quality had the strongest influence on the scattered spectrum in fluoroscopy. Many procedural factors affected the scattered spectrum indirectly through their effects on primary beam quality through ADRC, e.g., gantry angle and patient size. Lateral C-arm rotation, common in interventional cardiology, increased the energy of the scattered spectrum, regardless of the direction of rotation. The effect of patient size on scattered radiation depended on ADRC characteristics, patient size, and procedure type. Conclusion: The scattered spectrum striking the operator in fluoroscopy, and therefore the DRIP, is most strongly influenced by primary beam quality, particularly kV. Use cases for protective garments should be classified by typical procedural primary beam qualities, which are governed by the ADRC according to the impacts of patient size, anatomical location, and gantry angle. These results will help determine an appropriate set of SMPB to be used for measuring the DRIP.

60 APPLIED LIFE SCIENCES↗

SU-G-201-10: Experimental Determination of Modified TG-43 Dosimetry Parameters for the Xoft Axxent® Electronic Brachytherapy Source

Purpose: The establishment of an air kerma rate standard at NIST for the Xoft Axxent{sup ®} electronic brachytherapy source (Axxent{sup ®} source) motivated the establishment of a modified TG-43 dosimetry formalism. This work measures the modified dosimetry parameters for the Axxent{sup ®} source in the absence of a treatment applicator for implementation in Xoft’s treatment planning system. Methods: The dose-rate conversion coefficient (DRCC), radial dose function (RDF) values, and polar anisotropy (PA) were measured using TLD-100 microcubes with NIST-calibrated sources. The DRCC and RDF measurements were performed in liquid water using an annulus of Virtual Water™ designed to align the TLDs at the height of the anode at fixed radii from the source. The PA was measured at several distances from the source in a PMMA phantom. MCNP-determined absorbed dose energy dependence correction factors were used to convert from dose to TLD to dose to liquid water for the DRCC, RDF, and PA measurements. The intrinsic energy dependence correction factor from the work of Pike was used. The AKR was determined using a NIST-calibrated HDR1000 Plus well-type ionization chamber. Results: The DRCC was determined to be 8.6 (cGy/hr)/(µGy/min). The radial dose values were determined to be 1.00 (1cm), 0.60 (2cm), 0.42 (3cm), and 0.32 (4cm), with agreement ranging from (5.7% to 10.9%) from the work of Hiatt et al. 2015 and agreement from (2.8% to 6.8%) with internal MCNP simulations. Conclusion: This work presents a complete dataset of modified TG-43 dosimetry parameters for the Axxent{sup ®} source in the absence of an applicator. Prior to this study a DRCC had not been measured for the Axxent{sup ®} source. This data will be used for calculating dose distributions for patients receiving treatment with the Axxent{sup ®} source in Xoft’s breast balloon and vaginal applicators, and for intraoperative radiotherapy. Sources and partial funding for this work were provided by Xoft Inc. (a subsidiary of iCAD). This work was also supported by the Radiological Sciences T32 Training Grant through the University of Wisconsin-Madison Medical Physics department (5T32CA009206-37).

60 APPLIED LIFE SCIENCES↗

Mapping Patterns of Ipsilateral Supraclavicular Nodal Metastases in Breast Cancer: Rethinking the Clinical Target Volume for High-risk Patients

Purpose: To map the location of metastatic supraclavicular (SCV) lymph nodes (LNMs) in breast cancer patients with SCV node involvement and determine whether and where the radiation therapy clinical target volume (CTV) of this region could be modified in high-risk subsets. Methods and Materials: Fifty-five patients with metastatic SCV LNMs were eligible for geographic mapping and atlas coverage analysis. All LNMs and their epicenters were registered proportionally by referencing the surrounding landmarks onto simulation computed tomography images of a standard patient. CTVs based on selected SCV atlases, including the one by the Radiation Therapy Oncology Group (RTOG) were contoured. A modified SCV CTV was tried and shown to have better involved-node coverage and thus theoretically improved prophylaxis in this setting. Results: A total of 50 (91%) and 45 (81.8%) patients had LNMs in the medial and lateral SCV subregions, respectively. Also, 36 patients (65.5%) had LNMs located at the junction of the jugular-subclavian veins. All nodes were covered in only 25.5% to 41.8% of patients by different atlases. The RTOG atlas covered all nodes in 25.5% of patients. Stratified by the nodes in all the patients as a whole, 49.2% to 81.3% were covered, and the RTOG atlas covered 62.6%. The lateral and posterior borders were the most overlooked locations. Modification by extending the borders to natural anatomic barriers allowed the new CTV to cover all the nodes in 81.8% of patients and encompass 96.1% of all the nodes. Conclusions: According to the distribution of SCV LNMs, the extent of existing atlases might not be adequate for potential metastatic sites in certain groups of patients. The extension of the lateral and posterior CTV borders in high-risk or recurrent patients might be a reasonable approach for increasing coverage. However, additional data in more homogeneous populations with localized disease are needed before routine application.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-671: Range-Modulation Effects of Carbon Ion Beams in Lung Tissue

Purpose: When particles traversing inhomogeneous materials like lung they show a characteristic range modulation which cannot be observed in homogeneous materials. It is possible to describe the range modulation by a convolution of an unperturbed Bragg-Curve and a normal distribution. The sigma of the normal distribution is a parameter for the strength of the modulation effect. A new material parameter (modulation power, P-mod) is introduced which is independent of the material thickness. It is defined as the square of sigma divided by the mean water equivalent thickness of the target (µ). Methods: The modulation power of lung tissue was determined by actual Bragg-peak measurements after traversing an ex-vivo porcine lung and by Monte-Carlo simulations with micro-CT data of human lung tissue. The determined modulation powers were used to show the effect of range modulation effects in a simplified treatment situation. A four centimeter spread-out Bragg-peak after traversing eight centimeter of lung tissue was simulated in FLUKA. The SOBP with and without consideration of range modulation effects were compared. Results: As well in the measurements as in the MC simulations range modulation effects of lung tissue were observed. The determined modulation powers showed a great range from 0.05 mm, in the micro-CT data, to 0.7 mm in the lung measurements. The SOBP comparison showed that range modulation effects Result in over- and underdosages at the distal and proximal edge of the SOBP. In the investigated case, the last 0.5 cm of the SOBP showed an underdosage of up to 50% at the distal edge, while 0.5 cm distal to the SOBP an overdosage of up to 50% was observed. Conclusion: Range modulation effects occur in inhomogeneous materials like lung. These modulation effects may Result in clinically relevant over- and underdosages but are currently not considered in commercially available treatment planning systems.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Biomathematical Model of Lymphopoiesis and Its Application to Acute and Chronic Irradiation Assessment

After the events of September 11, 2001, there is an increasing concern of the occurrence of radiological terrorism that may result in significant casualties in densely populated areas. Much effort has been made to establish various biomarkers to rapidly assess radiation dose in mass-casualty and population-monitoring scenarios, which are demanded for effective medical management and treatment of the exposed victims. Among these the count of lymphocytes in peripheral blood and their depletion kinetics are the most important early indicators of the severity of the radiation injury. In this study, we examine a biomathematical model of lymphopoiesis which has been successfully utilized to simulate and interpret experimental data of acute and chronic irradiations on rodents [1]. With revised parameters for humans, we find this model can reproduce several sets of clinical lymphocyte data of accident victims over a wide range of absorbed doses. In addition, the absolute lymphocyte counts and the depletion rate constants calculated by this model also show good correlation with the Guskova formula and the Goans model, the two empirical tools which have been widely recognized for early estimation of the exposed dose after radiation accidents [2]. We also use the model to analyze the hematological data of the Techa River residents which were exposed to chronic low-dose irradiation during 1950-1956 [3]. This model can serve as a computational tool in radiation accident management, military operations involving nuclear warfare, radiation therapy, and space radiation risk assessment.

Hu, Shaowen↗

Source function from two-particle correlation function through entropy-regularized Richardson-Lucy deblurring

Source functions are obtained from p – p and d – α correlation functions by applying the Richardson-Lucy (RL) deblurring to the Koonin-Pratt (KP) equation. To prevent fitting of noise in the correlation function, total-variation (TV) regularization is employed that has been effective in ordinary image restoration. TV alone cannot ensure normalization of the source functions. To ensure the latter, we propose a maximum-entropy regularized RL algorithm (MEM-RL). We outline the MEM-RL formalism and optimization strategy for the KP equation, demonstrating its effectiveness on both simulated and experimental data, including the p – p and d – α correlation functions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Threat Sources for Creating Synthetic Urban Search Data

Equivalent point source energy emission distributions were computed for various threat sources for use in simulating the detector responses for urban search scenarios. The sources include standard isotopic sources used in detector testing, medical and industrial sources occasionally encountered in urban searches, and several types of special nuclear materials. Most of the equivalent point source distributions represent small sources inside some amount of shielding, but the special nuclear material sources represent volumetrically distributed sources in spheres of metal. Text-based inputs for emission distributions are available for the Monte Carlo transport codes Monte Carlo N-Particle, SCALE/MAVRIC, and Omnibus/Shift, any of which can easily be converted to other formats. These sources were developed for use in the Radiological Anomaly Detection and Identification (RADAI) project and the follow-on project, the RADAI-Extended project, sponsored by the National Nuclear Security Administration Office of Defense Nuclear Nonproliferation Research and Development.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-648: Quality Assurance Using the RADPOS System for 4D Radiotherapy with CyberKnife

Purpose: The CyberKnife robotic radiosurgery system uses Synchrony respiratory motion compensation, which requires independent performance verification. In this work, the RADPOS 4D dosimetry system’s motion measurements are compared with internal fiducial position measurements. In addition, RADPOS measurements are compared with Synchrony’s predictive correlation model, which is based on internal fiducial and external LED marker position measurements. Methods: A treatment plan was created for a lung insert containing fiducials, RADPOS detector, and Solid Water tumor phantom. Two Quasar Respiratory Motion Phantoms (Q1 and Q2) and two RADPOS detectors (R1 and R2) were used: Q1 simulated lung motion with a lung insert moving in the superior/inferior direction, while Q2 simulated chest motion with a chest platform moving in the anterior/posterior direction. Before treatment, R1 was secured inside of the tumor phantom within Q1, while LED markers and R2 were positioned on the chest platform of Q2. Two treatment delivery cases were studied: isocentric plan (I) and non-isocentric patient plan (P). Four motion cases were studied: no motion (0), sinusoidal and in-phase (1), sinusoidal and out-of-phase (2), patient waveform and out-of-phase (3). A coordinate alignment algorithm was implemented, allowing RADPOS and model position data to be compared within the fiducial coordinate system. Results: The standard deviation of the differences between RADPOS and fiducial position measurements was below 0.6 mm for all experimental cases. The standard deviation of the differences between RADPOS and model position data was 1.0, 1.5, and 1.6 mm along the primary direction of motion for case I1, I2, and P3, respectively. Conclusion: Our work demonstrates that RADPOS is a useful tool for independent quality assurance of CyberKnife treatment with Synchrony respiratory compensation. RADPOS and fiducial position measurement closely match, and RADPOS confirms the effectiveness of CyberKnife’s Synchrony motion tracking. This work was supported by OCAIRO (Ontario Consortium for Adaptive Interventions in Radiation Oncology) grant.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Population of 224 realistic human subject-based computational breast phantoms

Purpose: To create a database of highly realistic and anatomically variable 3D virtual breast phantoms based on dedicated breast computed tomography (bCT) data. Methods: A tissue classification and segmentation algorithm was used to create realistic and detailed 3D computational breast phantoms based on 230 + dedicated bCT datasets from normal human subjects. The breast volume was identified using a coarse three-class fuzzy C-means segmentation algorithm which accounted for and removed motion blur at the breast periphery. Noise in the bCT data was reduced through application of a postreconstruction 3D bilateral filter. A 3D adipose nonuniformity (bias field) correction was then applied followed by glandular segmentation using a 3D bias-corrected fuzzy C-means algorithm. Multiple tissue classes were defined including skin, adipose, and several fractional glandular densities. Following segmentation, a skin mask was produced which preserved the interdigitated skin, adipose, and glandular boundaries of the skin interior. Finally, surface modeling was used to produce digital phantoms with methods complementary to the XCAT suite of digital human phantoms. Results: After rejecting some datasets due to artifacts, 224 virtual breast phantoms were created which emulate the complex breast parenchyma of actual human subjects. The volume breast density (with skin) ranged from 5.5% to 66.3% with a mean value of 25.3% ± 13.2%. Breast volumes ranged from 25.0 to 2099.6 ml with a mean value of 716.3 ± 386.5 ml. Three breast phantoms were selected for imaging with digital compression (using finite element modeling) and simple ray-tracing, and the results show promise in their potential to produce realistic simulated mammograms. Conclusions: This work provides a new population of 224 breast phantoms based on in vivo bCT data for imaging research. Compared to previous studies based on only a few prototype cases, this dataset provides a rich source of new cases spanning a wide range of breast types, volumes, densities, and parenchymal patterns.

61 RADIATION PROTECTION AND DOSIMETRY↗

Free-moving Quantitative Gamma-ray Imaging

The ability to map and estimate the activity of radiological source distributions in unknown three-dimensional environments has applications in the prevention and response to radiological accidents or threats as well as the enforcement and verification of international nuclear non-proliferation agreements. Such a capability requires well-characterized detector response functions, accurate time-dependent detector position and orientation data, a digitized representation of the surrounding 3D environment, and appropriate image reconstruction and uncertainty quantification methods. We have previously demonstrated 3D mapping of gamma-ray emitters with free-moving detector systems on a relative intensity scale using a technique called Scene Data Fusion (SDF). Here we characterize the detector response of a multi-element gamma-ray imaging system using experimentally benchmarked Monte Carlo simulations and perform 3D mapping on an absolute intensity scale. We present experimental reconstruction results from hand-carried and airborne measurements with point-like and distributed sources in known configurations, demonstrating quantitative SDF in complex 3D environments.

47 OTHER INSTRUMENTATION↗

Experimental evaluation of neural probe’s insertion induced injury based on digital image correlation method

Purpose: The application of neural probes in clinic has been challenged by probes’ short lifetime when implanted into brain tissue. The primary goal is to develop an evaluation system for testing brain tissue injury induced by neural probe’s insertion using microscope based digital image correlation method. Methods: A brain tissue phantom made of silicone rubber with speckle pattern on its surface was fabricated. To obtain the optimal speckle pattern, mean intensity gradient parameter was used for quality assessment. The designed testing system consists of three modules: (a) load module for simulating neural electrode implantation process; (b) data acquisition module to capture micrographs of speckle pattern and to obtain reactive forces during the insertion of the probe; (c) postprocessing module for extracting tissue deformation information from the captured speckle patterns. On the basis of the evaluation system, the effects of probe wedge angle, insertion speed, and probe streamline on insertion induced tissue injury were investigated. Results: The optimal quality speckle pattern can be attained by the following fabrication parameters: spin coating rate—1000 r/min, silicone rubber component A: silicone rubber component B: softener: graphite = 5 ml: 5 ml: 2 ml: 0.6 g. The probe wedge angle has a significant effect on tissue injury. Compared to wedge angle 40° and 20°, maximum principal strain of 60° wedge angle was increased by 40.3% and 87.5%, respectively; compared with a relatively higher speed (500 μm/s), the maximum principle strain within the tissue induced by slow insertion speed (100 μm/s) was increased by 14.3%; insertion force required by probe with convex streamline was smaller than the force of traditional probe. Based on the experimental results, a novel neural probe that has a rounded tip covered by a biodegradable silk protein coating with convex streamline was proposed, which has both lower insertion and micromotion induced tissue injury. Conclusions: The established evaluation system has provided a simulation environment for testing brain tissue injury produced by various insertion conditions. At the same time, it eliminates the adverse effect of biological factors on tissue deformation during the experiment, improving the repeatability of measurement results. As a result, the evaluation system will provide support on novel neural probe design that can reduce the acute tissue injury during the implantation of the probe.

61 RADIATION PROTECTION AND DOSIMETRY↗

Transfer functions for Q A /Q B international regulatory limits for the safe transport of radioactive materials

This paper presents a proposed revision of the International Atomic Energy Agency transport regulations, related to the A 1 and A 2 limit values used to determine the radioactive transport classification. Based on the 'Q system', a novel methodology was introduced to derive Q A and Q B values related to scenarios involving external exposure from a distant source. These values are key parameters that respectively represent the total effective dose and total equivalent dose to the skin, from all primary and secondary particles contributing to radiation exposure. The International Working Group (WG A 1 /A 2 ) is established and associated with the TRANSSC Technical Expert Group on Radiation Protection. A review of the A 1 and A 2 values is performed in response to identified limitations within the existing Q system. The followed approach is based on Monte Carlo simulations that enabled the development of transfer functions aimed at reducing computational time and increasing the flexibility of dose evaluations for any radionuclide with known particle emission spectra. This method allows updating the Q A and Q B values to account for future data evolutions (decay data, fluence-to-dose conversion coefficients) and standardizing the calculation of regulation limits across all referenced radionuclides and scenarios related to external exposure. The transfer functions are established using three Monte Carlo simulation codes—FLUKA, Geant4, and MCNP—and address the previous limitations of the 'Q system', reflecting the latest International Commission for Radiation Protection recommendations and improvements in calculation techniques. The results of the WG show consistent agreement across the codes, with minor discrepancies observed at low primary energies due to statistical uncertainties and different handling of stopping power for electrons/positrons in the codes. This revised approach aligns with current standards and recommendations, ensuring that the radiological consequences of transport accidents are acceptable for the new A 1 and A 2 limits from a radiological protection perspective.

61 RADIATION PROTECTION AND DOSIMETRY↗