Control of a Three-Phase Grid-Connected Voltage-Sourced Converter Using Long Short-Term Memory Networks

With the rise of inverter-based resources (IBRs) within the power system, the control of grid-connected converters (GCCs) has become pertinent due to the fact they interface IBRs to the grid. The conventional method of control for a GCC such as the voltage-sourced converter (VSC) is through a decoupled control loop in the synchronous reference frame. However, this model-based control method is sensitive to parameter changes causing deterioration in controller performance. Data-driven approaches such as machine learning can be utilized to design controllers that are capable of operating GCCs in various system conditions. This work explores a deep learning-based control method for a three-phase grid-connected VSC, specifically utilizing a long short-term memory (LSTM) network for robust control. Simulations of a conventional controlled VSC are conducted using Simulink to collect data for training the LSTM-based controller. The LSTM model is built and trained using the Keras and TensorFlow libraries in Python and tested in Simulink. The performance of the LSTM-based controller is evaluated under different case studies and compared to the conventional method of control. Simulation results demonstrate the effectiveness of this approach by outperforming the conventional controller and maintaining stability under different system parameter changes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A dynamic model of once-through steam generator (OTSG) for prototypical advanced reactor - 374

new design of Small Modular Reactor, the Prototypical Advanced Reactor (PAR), features two sodium primary systems each connected to dedicated steam generators (SGs) and sharing a balance of plant (BOP) system. PAR adopts once-through steam generators (OTSG) for its compact structure. The existence of superheated steam in a OTSG improves turbine design by eliminating the need of bulky moisture separator in SG. The two cores and SGs' design enable PAR to adjust power flexibly, as a result, introduce more challenges to the control. Therefore, a fast simulation model with high accuracy OTSG model is needed. In this paper, a dynamic model is built for OTSG of PAR based on the conservation of mass, momentum, and energy. The OTSG is simulated as lumped pipe and divided into subcooled, evaporating, and superheated regions by moving boundaries. SIMULINK is adopted to this OTSG simulation to be merged into existing PAR system models easily. The steady state results show that key parameters are rational. The 5% step increase of feedwater enthalpy transient demonstrates that the model is capable to respond to the perturbations. Since the basic laws and algebraic method used in this paper are suitable for other fluids, the model can be easily applied to any other OTSG. Future work will also focus on model optimization, merging and improved control. The final aim is to perform full scope realtime simulations for PAR under normal operational transients. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Achieving Verifiable and High Integrity Instrumentation and Control Systems through Complexity Awareness and Constrained Design. Final Report

While most process control industries have been able to embrace digital Instrumentation and Control (I&C) technology to improve performance, reliability, maintainability, and efficiency of production, the nuclear industry has been relatively slow to adopt digital I&C for safety critical plant functions. There are a variety of reasons for this, but in general the nuclear industry takes a conservative stance that new technologies must mature before adoption. A deeper underlying reason for not fully realizing digital I&C and automation in nuclear power is associated with the complexity that can manifest in software-based systems that is different in nature from the complexity of their analog predecessors. Accordingly, this research pursued the development of innovative architectures and methods to “constrain complexity” to enhance verifiability of digital I&C devices. These constraints can positively impact the reduction of Software Common Cause Failures (SCCF) and other systematic errors. The architectural concept developed in this research effort is called SymPLe. SymPLe is specifically aimed at safety critical functions within Nuclear Power Plants and other critical infrastructure where constraining device complexity to support verifiability and safety case arguments is important. The SymPLe architecture is designed to promote “accessible verification” between OEM/utility engineers and the regulatory agencies who review and license nuclear power plant I&C systems. The major contributions of this work to the nuclear industry are: Demonstration of SymPLe as a viable approach to “complexity aware” I&C systems and Embedded Digital Devices.Comprehensive use of model-based design and engineering to produce verifiable I&C systems for the nuclear industry with clear findings on the usability of model-based engineering. Employ comprehensive use of model-based engineering, testing, and verification in an IEC 61508 workflow in support of design assurance. Gathered evidence of “difficult to find” design flaws found using model-based design and testing methods. Detailed the nature of these SCCFs including where they were introduced, the triggers, and how they were found. Gathered evidence on the synergistic use of practical formal methods and testing and how these methods can be used to significantly increase assurance of reduction and avoidance of design flaws.

Testing↗

PhotoVoltaic distributed generation for Lanai power grid real-time simulation and control integration scenario.

This paper discusses the modeling, analysis, and testing in a real-time simulation environment of the Lanai power grid system for the integration and control of PhotoVoltaic (PV) distributed generation. The Lanai Island in Hawaii is part of the Hawaii Clean Energy Initiative (HCEI) to transition to 30% renewable green energy penetration by 2030. In Lanai the primary loads come from two Castle and Cook Resorts, in addition to residential needs. The total peak load profile is 12470 V, 5.5 MW. Currently there are several diesel generators that meet these loading requirements. As part of the HCEI, Lanai has initially installed 1.2 MW of PV generation. The goal of this study has been to evaluate the impact of the PV with respect to the conventional carbon-based diesel generation in real time simulation. For intermittent PV distributed generation, the overall stability and transient responses are investigated. A simple Lanai 'like' model has been developed in the Matlab/Simulink environment (see Fig. 1) and to accommodate real-time simulation of the hybrid power grid system the Opal-RT Technologies RT-Lab environment is used. The diesel generators have been modelled using the SimPowerSystems toolbox swing equations and a custom Simulink module has been developed for the High level PV generation. All of the loads have been characterized primarily as distribution lines with series resistive load banks with one VAR load bank. Three-phase faults are implemented for each bus. Both conventional and advanced control architectures will be used to evaluate the integration of the PV onto the current power grid system. The baseline numerical results include the stable performance of the power grid during varying cloud cover (PV generation ramping up/down) scenarios. The importance of assessing the real-time scenario is included.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analysis of the Current Limiting Performance of a Novel DC-SFCL in the VSC-HVDC System

With increasing demand of the power load and the development of the new energy resources, voltage-sourced converter-based high-voltage direct current (VSC-HVDC) transmission system has been widely utilized. However, its development is seriously limited due to short circuit. To address this, high-temperature superconducting direct current fault current limiter (DC-SFCL) is designed. In this paper, a novel topology of DC-SFCL is firstly presented along with its principle and mathematical model. Secondly, the thermoelectric model of its superconducting current-limiting unit (SCLU) is established. In addition, simulation of VSC-HVDC system containing this novel DC-SFCL topology is analyzed using Simulink software. Finally, experimental measurements are designed and conducted to verify the correctness of the theoretical model.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Graphite Oxidation Simulation in HTR Accident Conditions (3 rd Year and Final Technical Report)

Massive air and water ingress, following a pipe break or leak in steam-generator tubes, is a design-basis accident for high-temperature reactors (HTRs). Analysis of these accidents in both prismatic and pebble bed HTRs requires state-of-the-art capability for predictions of: 1) oxidation kinetics, 2) air helium gas mixture stratification and diffusion into the core following the depressurization, 3) transport of multi-species gas mixture, and 4) graphite corrosion. This project will develop a multi-dimensional, comprehensive oxidation kinetics model of graphite in HTRs, with diverse capabilities for handling different flow regimes. The chemical kinetics/multi-species transport model for graphite burning and oxidation will account for temperature-related changes in the properties of graphite, oxidants (O 2 , H 2 O, CO), reaction products (CO, CO 2 , H 2 , CH 4 ) and other gases in the mixture (He and N2). The model will treat the oxidation and corrosion of graphite in geometries representative of HTR core component at temperatures of 900°C or higher. The developed chemical reaction kinetics model will be user-friendly for coupling to full core analysis codes such as MELCOR and RELAP, as well as computational fluid dynamics (CFD) codes such as CD-adapco. The research team will solve governing equations for the multi-dimensional flow and the chemical reactions and kinetics using Simulink, an extension of the MATLAB solver, and will validate and benchmark the model's predictions using reported experimental data. Researchers will develop an interface to couple the validated model to a commercially available CFD fluid flow and thermal-hydraulic model of the reactor , and will perform a simulation of a pipe break in a prismatic core HTR, with the potential for future application to a pebble-bed type HTR.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A Model-Free Frequency Control Approach for Diesel-Wind Powered Microgrids

Islanded microgrids usually consist of diesel generators and renewable energy sources (RES) to reduce the operating cost. Such microgrids have shown values for powering remote locations, but introduced unique challenges for frequency control of the grid due to the variability of renewable energy as well as the decoupled design of converter interface in RES. So, supportive control in RES becomes mandatory in such networks. This paper proposes a new dynamic control strategy, based on model-free control (MFC) approach, to support the primary frequency control of such islanded microgrids. The practical values of MFC have been discussed in various domains due to its control capability without modeling procedure and its efficient computation. In particular, we consider the diesel-wind system and the proposed MFC strategy is utilized as an online controller, which computes supplementary control signals for the rotor-side converter of the available wind turbine generators (WTGs). The calculated input signals allow WTGs to respond to frequency variations and improve the frequency response of the system. The controller is implemented and verified using the modified IEEE 33-bus full nonlinear model of the three-phase diesel-wind system in Simulink. Simulation results show the enhanced frequency response from the MFC strategy.

Park, Byungkwon↗

Real-Time Digital Simulation of Inertial Response with Hardware-in-the-Loop Implementation on the CART3 Wind Turbine at the National Wind Technology Center

With increasing penetrations of wind power on electric grids, the stability and reliability of interconnected power systems may be impacted. In some countries that have developed renewable energy sources and systems, grid codes have been revised to require wind power plants (WPPs) to provide ancillary services to support the power system frequency in case of severe grid events. To do this, wind turbine generators (WTGs) should be deloaded to reserve a certain amount of active power for primary frequency response; however, deloading curtails annual energy production, and the market for this type of service needs to be further developed. In this report, we focus on the temporary frequency support provided by WTGs through inertial response. WTGs have potential to provide inertial response, but appropriate control methods should be implemented. With the implemented inertial control methods, wind turbines are capable of increasing their active power output by releasing some of their stored kinetic energy when a frequency excursion occurs. Active power can be temporarily boosted above the maximum power points, after which the rotor speed decelerates, and subsequently an active power output reduction restores the kinetic energy. In this report, we develop two types of models for wind power systems: the first is common, based on the wind power aerodynamic equation, and the power coefficient can be regressed using nonlinear functions; the second is much more complicated, wherein the wind turbine system is modeled using the Fatigue, Aerodynamics, Structures, and Turbulence Modeling (FAST) tool with several degrees of freedoms. A nine-bus test power system is built in Simulink and the Real-Time Digital Simulator, respectively, which are used to evaluate the frequency support performance of the WPPs. We implement two distinct types of inertial control methods in the modeled wind turbines: frequency-based inertial control (FBIC) and stepwise inertial control (SIC). We compare the performances of the two methods in terms of their frequency nadirs, rates of change of frequency, and recovery times. We conclude the results under various wind speeds and penetration cases, which provide insight into designing the inertial response of WTGs. Further, we discuss the impact of the parameters on the performance of the inertial control methods. We evaluate both the scaling factors for the FBIC method and the slope values for the TLIC methods. The simulation work shows the characteristics of different inertial responses compared to conventional synchronous generators. Based on the simulation results, we modify, improve, and test the inertial control methods under a more realistic wind turbine model based on FAST. We then validate the inertial responses under highly turbulent wind conditions generated by TurbSim, and we examine their influences on the turbine mechanical components. The extensive simulation proves the effectiveness of the proposed inertial control methods as well as the nine-bus test power system. We then reconsider the parameters. We rebuild the same test power system using Real time Simulator Computer Aided Design (RSCAD), and we implement the inertial control methods in the real Controls Advanced Research Turbine (CART3), which is prepared for the hardware-in-the-loop field-test simulation. After the setups for the hardware and software hybrid simulation platform are complete, the inertial response is further tested on a real wind turbine for the first time, in which CART3 release the controlled inertial response against the emulated frequency excursion, provided by the real-time simulated power system test bed in RTDS.

17 WIND ENERGY↗

Optimization of Marine Energy Conversion Systems Through Modeling, Optimization, and CHIL Validation

The work aims to achieve optimal tidal energy conversion through a comprehensive approach of modeling, optimization, and control hardware-in-the-loop (CHIL) validation. By developing accurate models and employing optimization techniques, it seeks to identify efficient system configurations and control strategies. HIL validation will ensure the performance and reliability of the optimized tidal energy conversion system. The preparation of the present manual has been supported by the U.S. Department of Energy.

16 TIDAL AND WAVE POWER↗

Development of Tritium Permeation Analysis Code (TPAC)

Idaho National Laboratory developed the Tritium Permeation Analysis Code (TPAC) for tritium permeation in the Very High Temperature Gas Cooled Reactor (VHTR). All the component models in the VHTR were developed and were embedded into the MATHLAB SIMULINK package with a Graphic User Interface. The governing equations of the nuclear ternary reaction and thermal neutron capture reactions from impurities in helium and graphite core, reflector, and control rods were implemented. The TPAC code was verified using analytical solutions for the tritium birth rate from the ternary fission, the birth rate from 3He, and the birth rate from 10B. This paper also provides comparisons of the TPAC with the existing other codes. A VHTR reference design was selected for tritium permeation study from the reference design to the nuclear-assisted hydrogen production plant and some sensitivity study results are presented based on the HTGR outlet temperature of 750 degrees C.

99 GENERAL AND MISCELLANEOUS↗

Model Predictive Control of Integrated Gasification Combined Cycle Power Plants

The primary project objectives were to understand how the process design of an integrated gasification combined cycle (IGCC) power plant affects the dynamic operability and controllability of the process. Steady-state and dynamic simulation models were developed to predict the process behavior during typical transients that occur in plant operation. Advanced control strategies were developed to improve the ability of the process to follow changes in the power load demand, and to improve performance during transitions between power levels. Another objective of the proposed work was to educate graduate and undergraduate students in the application of process systems and control to coal technology. Educational materials were developed for use in engineering courses to further broaden this exposure to many students. ASPENTECH software was used to perform steady-state and dynamic simulations of an IGCC power plant. Linear systems analysis techniques were used to assess the steady-state and dynamic operability of the power plant under various plant operating conditions. Model predictive control (MPC) strategies were developed to improve the dynamic operation of the power plants. MATLAB and SIMULINK software were used for systems analysis and control system design, and the SIMULINK functionality in ASPEN DYNAMICS was used to test the control strategies on the simulated process. Project funds were used to support a Ph.D. student to receive education and training in coal technology and the application of modeling and simulation techniques.

01 COAL, LIGNITE, AND PEAT↗

2024 Incubator Final Report: Active Hybrid Mooring

This Incubator project has defined and developed a representation of an active hybrid mooring (AHM) system in Simulink to assess whether the speed and accuracy of AHM is sufficient to warrant further investigation in a larger project. We first built a representative mooring system for the VolturnUS-S 15MW floating offshore wind turbine (FOWT) in 1,000-meter water depth to provide baseline loads and displacements needed in the AHM system, with the results showing off-the-shelf actuators would be practical. We then defined model configurations for the numerical and physical substructures, using standalone MoorDyn v2 with a novel input strategy and chained hydraulic actuators represented in Simulink Simscape, respectively. The remainder of the project has focused on verifying the existing models for speed and accuracy against OpenFAST simulations, increasing their complexity to enable six degree of freedom (6DOF) operation, and connecting the numerical and physical substructures into a single holistic model. The verification phase of the project has shown promising results, though further refinement is needed to resolve accuracy discrepancies and for robust performance across a wider range of metocean conditions. The numerical model we developed is computationally stable and operates faster than real time using a time step of 0.01 seconds or shorter, indicating the model is likely fast enough for our AHM design to operate successfully. Additionally, the Simscape model of a hydraulic actuator operates with less than 0.3% relative error when actuating mooring loads from an OpenFAST simulation of the VolturnUS-S 1,000-meter mooring system. The aforementined refinements will be performed in the next year as a Continuing Incubator, with key remaining tasks include programming the predictor-corrector loop to minimize movement error, testing against more complex nonlinear wave cases, and expanding to enable loads from connected shared mooring lines.

17 WIND ENERGY↗

Multivariable Robust Control of a Simulated Hybrid Solid Oxide Fuel Cell Gas Turbine Plant

This work presents a systematic approach to the multivariable robust control of a hybrid fuel cell gas turbine plant. The hybrid configuration under investigation built by the National Energy Technology Laboratory comprises a physical simulation of a 300kW fuel cell coupled to a 120kW auxiliary power unit single spool gas turbine. The public facility provides for the testing and simulation of different fuel cell models that in turn help identify the key difficulties encountered in the transient operation of such systems. An empirical model of the built facility comprising a simulated fuel cell cathode volume and balance of plant components is derived via frequency response data. Through the modulation of various airflow bypass valves within the hybrid configuration, Bode plots are used to derive key input/output interactions in transfer function format. A multivariate system is then built from individual transfer functions, creating a matrix that serves as the nominal plant in an H{sub {infinity}} robust control algorithm. The controller’s main objective is to track and maintain hybrid operational constraints in the fuel cell’s cathode airflow, and the turbo machinery states of temperature and speed, under transient disturbances. This algorithm is then tested on a Simulink/MatLab platform for various perturbations of load and fuel cell heat effluence. As a complementary tool to the aforementioned empirical plant, a nonlinear analytical model faithful to the existing process and instrumentation arrangement is evaluated and designed in the Simulink environment. This parallel task intends to serve as a building block to scalable hybrid configurations that might require a more detailed nonlinear representation for a wide variety of controller schemes and hardware implementations.

30 DIRECT ENERGY CONVERSION↗

Flex Fuel Optimized SI and HCCI Engine

The central objective of the proposed work is to demonstrate an HCCI (homogeneous charge compression ignition) capable SI (spark ignited) engine that is capable of fast and smooth mode transition between SI and HCCI combustion modes. The model-based control technique was used to develop and validate the proposed control strategy for the fast and smooth combustion mode transition based upon the developed control-oriented engine; and an HCCI capable SI engine was designed and constructed using production ready two-step valve-train with electrical variable valve timing actuating system. Finally, smooth combustion mode transition was demonstrated on a metal engine within eight engine cycles. The Chrysler turbocharged 2.0L I4 direct injection engine was selected as the base engine for the project and the engine was modified to fit the two-step valve with electrical variable valve timing actuating system. To develop the model-based control strategy for stable HCCI combustion and smooth combustion mode transition between SI and HCCI combustion, a control-oriented real-time engine model was developed and implemented into the MSU HIL (hardware-in-the-loop) simulation environment. The developed model was used to study the engine actuating system requirement for the smooth and fast combustion mode transition and to develop the proposed mode transition control strategy. Finally, a single cylinder optical engine was designed and fabricated for studying the HCCI combustion characteristics. Optical engine combustion tests were conducted in both SI and HCCI combustion modes and the test results were used to calibrate the developed control-oriented engine model. Intensive GT-Power simulations were conducted to determine the optimal valve lift (high and low) and the cam phasing range. Delphi was selected to be the supplier for the two-step valve-train and Denso to be the electrical variable valve timing system supplier. A test bench was constructed to develop control strategies for the electrical variable valve timing (VVT) actuating system and satisfactory electrical VVT responses were obtained. Target engine control system was designed and fabricated at MSU for both single-cylinder optical and multi-cylinder metal engines. Finally, the developed control-oriented engine model was successfully implemented into the HIL simulation environment. The Chrysler 2.0L I4 DI engine was modified to fit the two-step vale with electrical variable valve timing actuating system. A used prototype engine was used as the base engine and the cylinder head was modified for the two-step valve with electrical VVT actuating system. Engine validation tests indicated that cylinder #3 has very high blow-by and it cannot be reduced with new pistons and rings. Due to the time constraint, it was decided to convert the four-cylinder engine into a single cylinder engine by blocking both intake and exhaust ports of the unused cylinders. The model-based combustion mode transition control algorithm was developed in the MSU HIL simulation environment and the Simulink based control strategy was implemented into the target engine controller. With both single-cylinder metal engine and control strategy ready, stable HCCI combustion was achived with COV of 2.1% Motoring tests were conducted to validate the actuator transient operations including valve lift, electrical variable valve timing, electronic throttle, multiple spark and injection controls. After the actuator operations were confirmed, 15-cycle smooth combustion mode transition from SI to HCCI combustion was achieved; and fast 8-cycle smooth combustion mode transition followed. With a fast electrical variable valve timing actuator, the number of engine cycles required for mode transition can be reduced down to five. It was also found that the combustion mode transition is sensitive to the charge air and engine coolant temperatures and regulating the corresponding temperatures to the target levels during the combustion mode transition is the key for a smooth combustion mode transition. As a summary, the proposed combustion mode transition strategy using the hybrid combustion mode that starts with the SI combustion and ends with the HCCI combustion was experimentally validated on a metal engine. The proposed model-based control approach made it possible to complete the SI-HCCI combustion mode transition within eight engine cycles utilizing the well controlled hybrid combustion mode. Without intensive control-oriented engine modeling and HIL simulation study of using the hybrid combustion mode during the mode transition, it would be impossible to validate the proposed combustion mode transition strategy in a very short period.

33 ADVANCED PROPULSION SYSTEMS↗

Equivalent-Circuit Models of Grid-Forming IBRs for Electromagnetic-Transient Simulations: Preprint

We derive equivalent-circuit models of control- and physical-layer subsystems of grid-forming (GFM) inverter-based resources (IBRs) for electromagnetic-transient (EMT) simulations. Three different primary controllers are considered: droop, virtual synchronous machine (VSM), and dispatchable virtual oscillator control (dVOC). In addition, the models include cascaded voltage- and current-control loops, and LCL output filters. Simulations for a single-inverter setup and for a network of five inverters in a modified IEEE 14-bus topology are presented. The equivalent-circuit models simulated with analog electronic circuit-simulator software (in our case, LTspice) offer the same accuracy with up to 150x lower computational burden compared to block-diagram-based implementations in commercial off-the-shelf EMT software (in our case, MATLAB-Simulink).

circuit-equivalent model↗

Simulation and Experimental Studies of a 2.45GHz Magnetron Source for an SRF Cavity with Field Amplitude and Phase Controls

Phase lock to an SRF cavity by using injection signal through output waveguide of a magnetron has been demonstrated [1, 3]. Amplitude control using magnetic field trimming and anode voltage modulation has been studied using MATLAB/Simulink simulations [2]. Based on these, we are planning to use an FPGA based digital LLRF system, which allows applying various types of control algorithms in order to achieve the required accelerating field stability. Since the 1497 MHz magnetron is still in the design stage, the proof of principle measurements of a commercial 2450 MHz magnetron are carried out to characterize the anode I-V curve, output power (the tube electronic efficiency), frequency dependence on the anode current (frequency pushing) and the Rieke diagram (frequency pulling by the reactive load). Based on early Simulink simulation, experimental data and extension of the Adler equation governing injection phase stability by Chen’s model, the specification of the new LLRF control chassis for both 2450 and 1497MHz systems are presented in this paper.

Wang, Haipeng↗

RPCSIM-SCO2 (Reactor Power and Control SIMulator for Supercritical CO2)

The RPCSIM-SCO2 code performs a dynamic simulation of a supercritical CO2 (carbon dioxide) Brayton cycle loop. The code is based on the MathLabTM program SimulinkTM from Mathworks. The Supercritical CO2 (S-CO2) model uses direct calls to the National Institute of Standards Refprop 9.0 Fortran library for the Equation-of-State (EOS) model for the CO2 working fluid (Lemmon, 2010). The calls to Refprop are made in the form of Simulink s-Functions that use a C interface to directly call the compiled Refprop fortran program library functions. Minor changes to the code can be made to use other working fluids. The code is intended to be used to perform many different types of dynamic cycle analysis for supercritical CO2 power producing systems. The code will calculate the transient temperature and pressure and all other thermodynamic properties at the inlet and outlet of each component given user supplied inputs such as rotor shaft speed, and heater power.

Wright, Steven A.↗

Equivalent-Circuit Models of Grid-Forming IBRs for Electromagnetic-Transient Simulations

We derive equivalent-circuit models of control- and physical-layer subsystems of grid-forming (GFM) inverter-based resources (IBRs) for electromagnetic-transient (EMT) simulations. Three different primary controllers are considered: Droop, Virtual Synchronous Machine (VSM), and dispatchable Virtual Oscillator Control (dVOC). In addition, the models include cascaded voltage- and current-control loops, and LCL output filters. Simulations for a single-inverter setup and for a network of five inverters in a modified IEEE 14-bus topology are presented. The equivalent-circuit models simulated with analog electronic circuit-simulator software (in our case, LTspice) offer the same accuracy, and with no explicit tuning of the solver, lower computational burden compared to block-diagram-based implementations in commercial off-the-shelf EMT software (in our case, MATLAB-Simulink).

electromagnetic transient simulation↗