Search NASA⌕ Search

SEARCH · Search NASA

Results for “Single Family Homes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

LA100 Equity Strategies. Chapter 6: Universal Access to Safe and Comfortable Home Temperatures

The LA100 Equity Strategies project integrates community guidance with robust research, modeling, and analysis to identify strategy options that can increase equitable outcomes in Los Angeles' clean energy transition. This chapter focuses on housing weatherization and cooling technologies as means to increase access to safe and comfortable home temperatures. Lack of cooling access and use can have severe health impacts on building occupants during heat waves. Specifically, NREL developed and used a residential building stock model to simulate the energy use of 50,000 dwellings representing the diversity of housing types, appliances, climate zones, and household incomes across Los Angeles. We compared a baseline scenario with seven upgrade scenarios. Five scenarios cooled the entire household and featured cooling systems at varying efficiency levels with various improvements to the envelope, roof, and shading, and two scenarios cooled a single room in a household with no prior cooling using either a room air-conditioning or a heat pump system. For each scenario, we evaluated impacts on utility bills, payback periods, and changes in energy burdens, as well as ability to achieve safe and comfortable temperatures. We also examined the effects of building types (multifamily vs. single-family) on indoor air temperatures. Based on the results of modeling, analysis, and community guidance, we identified six short-term and two long-term strategies for improving access to building envelope upgrades and cooling strategies that could save lives and maintain safe home temperatures for Los Angeles' low-income households during heat waves. Research was guided by input from the community engagement process, and associated equity strategies are presented in alignment with that guidance.

air conditioning↗

Technology Utilization House Study Report

The objectives of Project TECH are: (1) to construct a single family detached dwelling for demonstrating the application of advanced technology and minimizing the requirement for energy and utility services, and (2) to help influence future development in home construction by defining the interaction of integrated energy and water management systems with building configuration and construction materials. Components and methods expected to be cost effective over a 20 year span were studied. Emphasis was placed on the utilization of natural heating and cooling characteristics. Orientation and location of windows, landscaping, natural ventilation, and characteristics of the local climate and microclimate were intended to be used to best advantage. Energy conserving homes are most efficient when design for specific sites, therefore project TECH should not be considered a prototype design suitable for all locations. However, it does provide ideas and analytical methods which can be applied to some degree in all housing.

Source record↗

Solar-heating and cooling system design package

Package of information includes design data, performance specifications, drawings, hazard analysis, and spare parts list for commercially produced system installed in single-family dwelling in Akron, Ohio. System uses air flat-plate collectors, 12000 kg rock storage and backup heat pump. Solar portion requires 0.7 kW, and provides 35% of average total heating load including hot water. Information aids persons considering installing solar home-heating systems.

Source record↗

Reducing the cost of home energy upgrades in the US: An industry survey

Decarbonizing the US residential building stock requires a substantial acceleration in home energy upgrades. Numerous barriers exist to accelerating adoption of efficient and electric building technologies, but foremost among these is high upfront costs. This study uses an industry survey delivered to a sample of home energy professionals to examine promising cost reduction strategies across a range of project types, including HVAC, water heating, and envelope/insulation projects. The survey included quantitative and qualitative questions to collect evidence on the estimated cost reduction potential of these strategies and their likelihood of use in the construction industry. The 167 survey respondents included contractors, energy consultants, architects, manufacturers, and others with experience in delivering energy upgrades in single-family and multifamily buildings in the US. Results show that significant cost reductions are achievable by minimizing additional infrastructure costs (such as replacing electric panels), streamlining project planning/management, and deploying innovations that simplify installation. We find that for a typical deep retrofit project, including heat pumps for space and water heating in addition to envelope upgrades, the strategies could result in a total installed cost reduction of nearly 50%, dramatically improving the customer economics of such a project. This research makes a novel contribution to the literature on strategies to reduce the costs of residential retrofits. We discuss how our study's insights on the highest-value cost reduction strategies for home energy upgrades can further accelerate their uptake in the US housing stock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Oregon Residential Energy Code Field Study

A research project in the state of Oregon identified opportunities to reduce homeowner utility bills in residential single-family new construction by increasing compliance with the state energy code. The study was initiated in November 2019; data collection began in November 2019 and continued through February 2020. Analysis of the data has led to a better understanding of the energy features present in homes and identified over $600,000 in potential annual savings to Oregon homeowners that could result from increased compliance with the 2017 Oregon Residential Specialty Code (2017 ORSC).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Potential impact of work from home jobs on residential energy bills: A case study in phoenix, AZ, USA

Nearly one-third of U.S. households face challenges paying energy bills. During the day, many residents have routine access to cooled environments provided by others—employers, shopping centers, and other public buildings. The COVID-19 pandemic, however, has significantly shifted the cost burden of air conditioning in hot cities. Specifically, during the pandemic, many companies either laid off employees or put them in work-from-home (WFH) assignments. Large tech companies are already promoting WFH as a long-term option for their employees, even after the pandemic. This change in the nature of the workforce might reduce daily travel expenses for workers, but could also significantly increase residential energy bills, particularly during summer in very hot climates. Here, this study uses building energy simulations to quantify the potential residential energy bill penalties resulting from WFH for typical residences in Phoenix. Four building archetypes are used in this study to represent variations in building vintage, occupancy, and characteristics. The results show that, for some single-family residences in Phoenix, WFH can increase annual energy bills by more than $1100 (up to a 70% increase). The study also demonstrates that building performance enhancement retrofit measures have the potential to reduce this WFH energy bill penalty for the existing buildings substantially.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Waffle Homes: Utilizing Aerial Imagery of Unfinished Buildings to Determine Average Room Size

A primary function of the Population Density Tables Project (PDT) at Oak Ridge National Laboratory is to produce residential population densities per 1000 sq. ft. for each country and their associated first-level administrative units. This is accomplished by utilizing the average size of different types of dwelling areas (urban, rural, single-family, multi-family, etc.) and the average household size provided by a country’s Census or statistical bureau records. This data is available for the majority of Europe, North America, and large swathes of Asia, but is less easily found in Africa and South America. In these regions, Censuses generally report dwelling area by number of rooms, which poses the challenging question of how we can translate number of rooms to dwelling size when no dwelling size areas are available with which to compare. Using sub-meter resolution satellite imagery of Accra, Ghana, this challenge can be tackled using imagery of roofless buildings currently under construction that show the interior floor plan of the dwelling. A sample of buildings from the different neighborhoods of Accra can be digitized to provide an estimate and range of average room sizes of dwellings. This average room size can then be translated to a total dwelling area using the "number of rooms occupied by a household" variable from the Ghanaian Census. This intermediate step between average dwelling size and number of rooms occupied, fills the missing link that prevents PDT from continually producing new population densities for countries where dwelling size is unavailable through any official means.

Woody, Carson↗

Performance Evaluation of Drain Water Heat Recovery Exchangers for Heat Pump Water Heaters

Water heating constitutes approximately 18% of energy consumption and is the second largest energy expenses in United States homes. Heat pump water heaters (HPWHs) are energy efficient technologies with lower carbon footprints as compared to conventional water heating technologies, such as gas and electrical resistance heaters. The performance of water-source HPWHs can be improved by recovering heat from blackwater using drain heat recovery heat exchangers. Depending on water draw patterns of single family and multifamily residences, the operation and heat transfer performance of these heat exchangers are highly transient. This paper examines the thermo-hydraulic performance of a drain heat recovery heat exchanger during its transient and steady-state operations. The heat recovery performance of the exchanger was evaluated at different inlet temperatures and flow rates ranging from 9°C to 36°C and 0.03 kg/s to 0.28 kg/s, respectively. The obtained effectiveness varies from 45%–85% depending on the operating conditions. The test facility, steady-state and transient experimental procedures are reported in detail. Further, the effect of operating conditions on the effectiveness is discussed. The experimental approach and results of the study will provide insights into the transient operation of drain recovery heat exchangers as well as, guide sizing for various steady state conditions.

Krishnan, Easwaran↗

A high-fidelity residential building occupancy detection dataset

Abstract This paper describes development of a data acquisition system used to capture a range of occupancy related modalities from single-family residences, along with the dataset that was generated. The publicly available dataset includes: grayscale images at 32-by-32 pixels, captured every second; audio files, which have undergone processing to remove personally identifiable information; indoor environmental readings, captured every ten seconds; and ground truth binary occupancy status. The data acquisition system, coined the mobile human presence detection (HPDmobile) system, was deployed in six homes for a minimum duration of one month each, and captured all modalities from at least four different locations concurrently inside each home. The environmental modalities are available as captured, but to preserve the privacy and identity of the occupants, images were downsized and audio files went through a series of processing steps, as described in this paper. This dataset adds to a very small body of existing data, with applications to energy efficiency and indoor environmental quality.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Heat Pumps and Energy Recovering Ventilators in Northern Alaska

The intended purpose of this project was to bring alternative heat and ventilation options to rural communities off the road system in Northwestern Alaska. Most of the residents of these communities are reliant upon kerosene or other fossil fuels to provide heat to their homes. Our intention was to offer an alternative to using those sources by providing heat pumps to 45 homes in the communities of Elim and Koyuk. When projecting energy use for these units based on the fuel prices at the time, it was discovered that energy costs for heat pumps would equal or slightly exceed the costs of existing kerosene units. Secondly, as part of our E&l grant we installed 45 energy recovery ventilators (ERV’s) in those same homes. This was important given our experience over the years with moisture and comfort issues in most homes within this region. Exhaust-only systems are rarely used due to the high heating costs. Additionally, exhaust-only systems have a potential risk of back drafting due to tight building construction. Balanced systems like this eliminate that risk while improving indoor air quality. Another benefit to these types of systems is the fact that they help transfer heat from a single heat source equally throughout the building. Our overall goal was to offer new technology options to improve these structures and the families that reside in them where, given their location and extreme seasonal temperature swings, they have historically never been offered.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Operations of the Optical Communications Demonstration for the Orion EM-2 Mission

The GSFC implementation of an Optical Communication System to demonstrate an operational optical communication link for Orion EM-2. It will serve as a base for providing an operational optical communications capability for future Orion missions. GSFC plans to maintain a development path for the optical communication flight terminal to allow commercialization and implementation on future Orion missions. The Orion optical module part of the optical communications flight terminal and its control electronics have a common architecture with the ILLUMA-T optical terminal provided by GSFC for use on the ISS. The plan is to flow data from Orion through the Optical Communication Fight Terminal to the Optical Communication Ground Terminal and reverse. NASA's Orion spacecraft is an exploratory vehicle designed for longer-duration flights beyond the Moon. Following Orion's Exploration Mission-1 (EM-1), during which the spacecraft will travel beyond the Moon, enter a distant retrograde orbit around the Moon and return to Earth unmanned, Exploration Mission-2 (EM-2) will see a crewed spacecraft complete a slightly different flight path. First crewed test flight of the Orion spacecraft, currently targeting a June 30, 2022 launch. The mission involves: One revolution in Low Earth Orbit (LEO) parking orbit to verify basic Orion systems functionality and deploy solar arrays. A single 42-hour Highly Elliptical Orbit (HEO) intermediate checkout orbit allows characterization of the Orion vehicle system performance prior to committing to a cis-lunar flight. Trans Lunar Injection (TLI) burn using Orion Service Module (SM) main engine, which sends Orion on a lunar flyby and free return. Skip reentry at lunar return velocities to splashdown off the coast of San Diego. Total mission duration is approximately 10 days. EM-2 is the first crewed mission of the Orion Spacecraft that crew brings more video up/downloads, file transfers, and real-time chats with family back home and high-rate communications enables live HD streaming for Crew conferences, Public Affairs Office (PAO) events, and significant mission events. Also still collecting vehicle data on numerous Orion subsystems via Development Flight Instrumentation (DFI) allows large data volume returns sooner for DFI and future science payloads, as opposed to waiting for end-of-mission. O2O is a demonstration of operational utility system tested as a Developmental Test Objective (DTO) and not required to meet mission requirements/success/ Flight Test Objectives (FTO). EM-2 architecture is as close to future mission operational architecture as possible.Orion subsystems (video, DFI, etc.) expected to generate ~250 GB of data in the first 24 hours of flight. Total data generated over the mission estimated to be more than 400 GBUsing S-Band alone, Orion limited to ~ 6GB of data downlink per day. Because of this limitation, Orion is planning to limit live video downlinks on EM-1 in order to downlink high priority fileswith 1 hour/day of Optical Communication, Orion could downlink ~6x more data per day (~ 36GB/day).The optical communication system is capable of multiple data rates up to at least 80 Mbps downlink for the transfer of Orion data to Earth while Orion is operating in the lunar vicinity.

Optical Communication↗

Evaluating Building Energy Code Compliance and Savings Potential through Large-Scale Simulation with Models Inferred by Field Data

Building energy code compliance is the crucial link between the actual energy savings and the efficiency prescribed in energy codes. A research project aiming to identify opportunities to reduce energy consumption in new single-family residential construction by increasing compliance with the building energy code was conducted in several states of the United States. The study was comprised of three phases: (1) a baseline study to document typical practice and identify opportunities for improvement based on empirical data gathered from the field; (2) an education and training phase targeting the opportunities identified; and (3) a post-study to assess whether a reduction in average state-wide energy use could be achieved following the education and training phase. We proposed a novel methodology based on large-scale building energy simulation inferred by limited field data to assess the performance of a large population of homes. This paper presents the methodology, findings, and results of this study. The state-wide average energy consumption decreased at Phase III from Phase I for five of the seven states involved in the analysis. The measure-level savings potential analysis shows an overall reduction. Overall, the training and education phase plays a recognizable role in improving compliance with building energy codes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Metrics and Analytical Frameworks for Valuing Energy Efficiency and Distributed Energy Resources in the Built Environment: Preprint

This paper summarizes efforts to develop new—and enhance existing—analytical frameworks and metrics to quantify the value that grid-interactive efficient homes with solar (GEB-solar homes) can provide. Industry is working to characterize and understand these capabilities and benefits, but existing analytical frameworks for evaluating energy efficiency (EE) are often siloed from those that evaluate distributed energy resources (DERs). Five metrics were adapted from an extensive literature review and applied to case studies of a modeled home in Riverside, California: ramp up/down, cover factor demand/supply, and curtailable load. Eight different technology scenarios were analyzed using a more tightly connected suite of building-to-grid models (BEopt, REopt, ReEDS, and PLEXOS). Additionally, an initial version of the Cambium tool was developed, characterizing the marginal prices and emissions from NREL’s 2018 Standard Scenarios. These grid costs were extended to a time-varying proxy retail rate and applied as part of a new grid alignment metric. In the results, a more integrated combination of GEB-solar technologies led to a higher cover factor demand—the percentage of gross home load covered by on-site solar—however, a benchmark was required to determine what range of cover factor was “best” for given grid conditions. To that end, a grid alignment cost metric was applied to the case study scenarios. The average cost to serve the net load of the home decreased from a median of ~$0.24/kWh to ~$0.10/kWh when the most integrated technology scenario was optimized towards the grid pricing proxy versus the time-of-use (TOU) rate.

41 EE - Solar Energy Technologies Office (EE-4S)↗

There's No Place Like Home: Residential Parking, Electrical Access, and Implications for the Future of Electric Vehicle Charging Infrastructure

In March 2021, the cumulative sale of plug-in electric vehicles (PEVs), including plug-in hybrid electric vehicles (PHEV) and battery electric vehicles (BEV), reached 1.8 million in the United States (Argonne National Laboratory 2021). However, PEV adoption is still in its infancy; its market share has just reached around 3% of new light-duty vehicle (LDV) sales by the end of 2020 (Alliance for Automotive Innovation 2021). Current trends suggest that PEV market share in the United States is increasing. The U.S. Energy Information Administration's (EIA's) 2020 Annual Energy Outlook forecasts PEV registrations to exceed 8 million vehicles by 2030 (AEO 2020). PEV adoption is expected to be led by states that are regulating the sale of zero emission vehicles (ZEVs) (California Air Resources Board). California continues to push for more aggressive ZEV regulations; the state recently issued an executive order aimed at 100% of LDV sales being ZEVs by 2035 (Office of Governor Newsom). At the federal level, the Biden administration has shown great ambition in encouraging broader electric vehicle (EV) adoption, including setting the goal of installing 500,000 new chargers nationwide (The White House 2021). Access to charging infrastructure is consistently cited as one of the primary barriers to the increased sale of PHEVs and BEVs (Carley et al. 2019). In the United States, PEV charging options are often described using a pyramid structure, with residential charging as the foundation, workplace charging in the middle, and public charging on top (Figure 1). The existing electricity system, which generates, transmits, and distributes electric fuel to residential households, has helped PEVs partially overcome the "chicken and egg" conundrum that has haunted other alternative fuels. Viable home access to electric charging is also an important equity issue, because non-residential PEV charging options (e.g., workplace or public charging stations) are generally more expensive. Households without residential charging access may experience higher total cost of PEV ownership if non-residential charging options are more costly.

33 ADVANCED PROPULSION SYSTEMS↗

Field Evaluations of Sampling, Interviewing, and Flight Tracking of NASA's Low Boom Flight Demonstrator Aircraft

The first year’s effort identified sampling and interviewing as the principal risks to assessment of prompt reactions to overflights producing low-amplitude sonic booms. It also 1) established the utility of geo-information system-based route planning for LBFD flight missions, 2) developed and demonstrated a prototype of a geographically-distributed, Internet-enabled instrumentation system capable of wide-area tracking of LBFD aircraft in near-real time. The latter system permits synchronizing the conduct of interviews in multiple overflown communities with arrival times of shock waves at interviewing sites; and of measuring, archiving, and processing their acoustic signatures. Means were also recommended for constructing representative, telephone-based samples of eligible respondents living in households within carpet boom corridors adjacent to LBFD flight tracks, and for conducting interviews with cross-sectional (independent) samples of such respondents about their prompt reactions to exposure to low-amplitude sonic booms. A detailed study design was prepared and accepted by NASA for a set of single-contact attempt telephone interviews with a nationally representative sample of households. The study design focused on testing automated and live agent interview completion rates obtainable without callbacks. A minimal (two monitoring station) version of the aircraft tracking system was built and installed near a civil airport in a successful demonstration of the system’s ability to detect and track aircraft movements. The field exercise also demonstrated the ability of the system to capture the acoustic emissions of departing aircraft, and to serve aircraft position and sound level information to remote, geographically-distributed analysts in near-real time. Upon approval of OMB and IRB of the detailed study plan, a stratified, nationally representative sample of landline and wireless telephone-subscribing households was constructed. A total of 12,734 telephone interview contact attempts of the sort required by a straightforward cross-sectional study design were then made. These contact attempts demonstrated the impracticality of conducting a time-critical, cross-sectional study of prompt community response to low-amplitude sonic booms by means of “independent” (single contact attempt per respondent for each LBFD flight mission) telephone samples of respondents. The observed interview completion rates for these single telephone contact attempts were so low (~ 1% to 3% for automated and live agent interviews, respectively) that: 1) the representativeness of collected opinions would be susceptible to intuitive challenge as inadequate, even absent conclusive evidence of non-representativeness. Refuting challenges to representativeness would have to demonstrate that the composition of the actual sample did not differ from that of the target population, a task that is tantamount to proving a negative; 2) the information required to refute allegations of non-representativeness would require a questionnaire considerably lengthier than that required simply to determine the prevalence of boom-induced startle and annoyance. Such a questionnaire would have to inquire about potentially sensitive and intrusive matters, including respondents’ age, gender, education, employment, home ownership, income, ethnicity, family size, and other demographic factors; and 3) unreasonable numbers of attempts would be required to re-contact households with unsuccessful initial contact attempts, given the limited time available for doing so. For example, if about 500 completed interviews were desired in a supersonically overflown community, approximately 50,000 automated interview attempts would have to be made within ten to fifteen minutes of each LBFD overflight. Such large numbers of contact attempts could well exceed the numbers of households available for interview in areas of similar boom exposure levels in some communities near LBFD flight tracks. Such large numbers of interviews could be cost-effectively undertaken only by means of automated (i.e., outgoing interactive voice response) interviewing, a data collection method ill-suited for complex and sensitive questionnaire items. The infeasibility of independent sampling for evaluating prompt responses to LBFD overflights in a cross-sectional study is due in large part to simple non-response: that is, potential respondents – particularly those contacted on wireless telephones – refusing to answer calls with unfamiliar caller IDs. It is also due in part, however, to 1) the lack of time to attempt to contact the same respondent more than once within a few minutes after the arrival of a shock wave at the respondent’s location; and 2) the need to place calls during weekday/daytime hours, when response rates are notably lower than during evenings and weekends. Despite the poor interview completion rates achieved under the above constraints, cross sectional assessments of delayed reactions to LBFD overflights could still be feasible, if multiple attempts could be made to contact respondents during evening and weekend time periods, over extended time periods. Detailed plans for a longitudinal (panel) sample were developed as an alternative to a cross sectional sample design.

Fidell, Sanford↗

Understanding the Costs and Barriers of Residential Electrical Panel and Service Upgrades

Upgrading electrical panels and services in U.S. homes represents a significant barrier to building modernization, imposing considerable costs, delays, and procedural uncertainties on homeowners, contractors, utilities, and building departments. Although cost databases document individual infrastructure activities, they rarely capture the integrated, whole-project perspective required to understand how electrical upgrades are planned, executed, and regulated. Existing research is often geographically constrained, narrowly scoped, or derived from limited samples, leaving significant knowledge gaps unaddressed. This study examines the timelines and costs associated with residential electrical panel and service upgrades using data from a national cross- sectional survey conducted in summer 2025. The survey captured responses from 140 stakeholders across 34 states, including building industry professionals, utility staff, and building department staff. Findings indicate that project duration and cost increase substantially with building size though patterns vary by infrastructure type. Most single-family and small multifamily projects were completed within 30 days, whereas medium and large multifamily buildings show longer and less predictable timelines. Service rating increases modestly extend project duration, but building type and size were the primary determinants of delays. Cost patterns were similar: customer-side equipment and panel replacements scale predictably with building size, while utility-side costs are highly variable, often triggered by threshold-driven infrastructure upgrades such as transformer replacements. Permit fees vary considerably between jurisdictions but generally represent a minor proportion of total project costs. These findings identify electrical upgrades as a significant barrier to residential building costs and highlight the need for improved stakeholder coordination, streamlined permitting, and strategies that reduce upgrade requirements while maintaining safety and code compliance.

Casquero-Modrego, Nuria↗

Urban microclimate and its impact on building performance: A case study of San Francisco

Urban microclimate exerts an increasing influence on urban buildings, energy, and sustainability. This study uses 10-year measured hourly weather data at 27 sites in San Francisco, California, to (1) analyze and visualize the urban microclimate patterns and urban heat island effect; (2) simulate annual energy use and peak electricity demand of typical large office buildings and large hotels to investigate the influence of urban microclimate on building performance; (3) simulate indoor air temperature of a single-family house without air-conditioning during the record three-day heatwave of 2017, to quantify the divergence of climate resilience due to urban microclimate effect. Results show significant microclimate effects in San Francisco with up to 11 °C outdoor air temperature difference between the coastal and downtown areas on September 1, 2017, during the record three-day heatwave. The simulated energy results of the prototype large office and large hotel buildings using the 2017 weather data show over 100% difference in annual heating energy use and 65% difference in annual cooling energy use across different stations; as well as up to 30% difference in peak cooling electricity demand. The impacts on annual site or source energy use are minimal (less than 5%) as cooling and heating in a mild climate are a relatively small portion of overall building energy use in San Francisco. Results also show the microclimate effects influence indoor air temperature of unconditioned homes by up to 5 °C. Newer buildings and homes are much less affected by microclimate effects due to more stringent performance requirements of the building envelope and energy systems. Furthermore, these findings inform that San Francisco microclimate variations should be considered in urban energy planning, building energy codes and standards, as well as heat resilience policymaking.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Framework to select robust energy retrofit measures for residential communities

Residential building energy retrofits are essential for enhancing environmental sustainability and reducing energy costs. The selection of retrofit measures is influenced by factors such as building systems, occupant behavior, government policy, weather variability, and climate change, all of which can significantly impact energy performance. Compared to retrofitting individual homes, evaluating and selecting optimal retrofit solutions for an entire community is challenging due to diverse residential compositions and variability present. Therefore, engineering robustness is crucial for ensuring consistent energy performance and resilience across different conditions. In this context, robustness refers to the ability of a retrofit measure to maintain its functionality and remain an optimal choice despite external disturbances or changes in inputs and conditions. This study presents a framework for evaluating the robustness of multiple retrofit measures across various building systems, occupant behaviors, and environmental scenarios at the community level. The framework comprises five key steps: scenario model development, integration of the National Residential Efficiency Measures database, energy performance simulation, cost-benefit aggregation, and retrofit solution selection. Each step enhances the framework’s robustness by incorporating the diversity of building characteristics, occupant behaviors, environmental conditions, retrofit options, and evaluation criteria. The framework’s effectiveness is demonstrated through a case study in southern Michigan in the United States, which includes 63 one-story single-family houses, 121 two-story single-family houses, and 8 townhouses. The study identifies furnace retrofits as the most robust solution for the entire community, consistently achieving source energy reductions of 4.7 %–8.0 % and payback period of 10–20 years across various scenarios. These findings are consistent with previous research, indicating the framework’s potential for broader applications in optimizing community-scale residential energy retrofits.

Shu, Lei↗