Search NASA⌕ Search

SEARCH · Search NASA

Results for “Single use”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Predicting ptychography probe positions using single-shot phase retrieval neural network

Ptychography is a powerful imaging technique that is used in a variety of fields, including materials science, biology, and nanotechnology. However, the accuracy of the reconstructed ptychography image is highly dependent on the accuracy of the recorded probe positions which often contain errors. These errors are typically corrected jointly with phase retrieval through numerical optimization approaches. When the error accumulates along the scan path or when the error magnitude is large, these approaches may not converge with satisfactory result. We propose a fundamentally new approach for ptychography probe position prediction for data with large position errors, where a neural network is used to make single-shot phase retrieval on individual diffraction patterns, yielding the object image at each scan point. The pairwise offsets among these images are then found using a robust image registration method, and the results are combined to yield the complete scan path by constructing and solving a linear equation. We show that our method can achieve good position prediction accuracy for data with large and accumulating errors on the order of 10 2 pixels, a magnitude that often makes optimization-based algorithms fail to converge. For ptychography instruments without sophisticated position control equipment such as interferometers, our method is of significant practical potential.

47 OTHER INSTRUMENTATION↗

Evaluation of bearing configurations using the single bearing tester in liquid nitrogen

Various bearing configurations were tested using the Marshall Space Flight Center single bearing tester with LN2 as the cryogenic coolant. The baseline was one Rocketdyne phase one high pressure oxidizer turbopump (HPOTP) pump end 45-mm bore bearing. The bearing configurations that were tested included a Salox/M cage configuration, a silicon nitride ball configuration, an elongated cage configuration, and a Bray 601 grease configuration.

Jett, T.↗

A Method for Producing a Shaped Contour Radiation Pattern Using a Single Shaped Reflector and a Single Feed

Eliminating the corporate feed network in shaped contour beam antennas will reduce the expense, weight, and RF loss of the antenna system. One way of producing a shaped contour beam without using a feed network is to use a single shaped reflector with a single feed element. For a prescribed contour beam and feed, an optimization method for designing the reflector shape is given. As a design example, a shaped reflector is designed to produce a continental U.S. coverage (CONUS) beam. The RF performance of the shaped reflector is then verified by physical optics.

Cherrette, A. R.↗

A method for producing a shaped contour radiation pattern using a single shaped reflector and a single feed

Eliminating the corporate feed network in shaped contour beam antennas will reduce the expense, weight, and RF loss of the antenna system. One way of producing a shaped contour beam without using a feed network is to use a single shaped reflector with a single feed element. For a prescribed contour beam and feed, an optimization method for designing the reflector shape is given. As a design example, a shaped reflector is designed to produce a continental U.S. coverage (CONUS) beam. The RF performance of the shaped reflector is then verified by physical optics.

Cherrette, Alan R.↗

Using Single-Scattering Albedo Spectral Curvature to Characterize East Asian Aerosol Mixtures

Spectral dependence of aerosol single-scattering albedo (SSA) has been used to infer aerosol composition. In particular, aerosol mixtures dominated by dust absorption will have monotonically increasing SSA with wavelength while that dominated by black carbon absorption has monotonically decreasing SSA spectra. However, by analyzing SSA measured at four wavelengths, 440, 675, 870, and 1020 nm from the Aerosol Robotic Network data set, we find that the SSA spectra over East Asia are frequently peaked at 675 nm. In these cases, we suggest that SSA spectral curvature, defined as the negative of the second derivative of SSA as a function of wavelength, can provide additional information on the composition of these aerosol mixtures. Aerosol SSA spectral curvatures for East Asia during fall and winter are considerably larger than those found in places primarily dominated by biomass burning or dust aerosols. SSA curvature is found to increase as the SSA magnitude decreases. The curvature increases with coarse mode fraction (CMF) to a CMF value of about 0.4, then slightly decreases or remains constant at larger CMF. Mie calculations further verify that the strongest SSA curvature occurs at approx. 40% dust fraction, with 10% scattering aerosol fraction. The nonmonotonic SSA spectral dependence is likely associated with enhanced absorption in the shortwave by dust, absorption by black carbon at longer wavelengths, and also the flattened absorption optical depth spectral dependence due to the increased particle size.

curvature↗

Characterizing Face Sheet/Core Disbonding Using the Single Cantilever Beam Test: Results from an International Round Robin

Test results from an international round robin are presented. The single cantilever beam (SCB) test was used to characterize face sheet/core disbonding in sandwich components in an effort to help standardization. Each of the seven participating laboratories performed a set of five baseline tests using the same protocol, however, using their own specific equipment. In addition, each laboratory performed two sets of tests with altered tests conditions which included using a test fixture with a translating carriage and performing the tests with different loading and unloading speeds. The orientation of the disbond front with respect to the honeycomb core cells was varied and the effect on the fracture toughness was also studied. Additional factors that could influence test results were investigated, such as the use of a saw cut starter disbond as an alternative to Teflon® release film, and the effects of using a face sheet doubler to increase the bending stiffness. For each set of tests, summary results such as load/displacements plots, observed disbond growth location and calculated energy release rates are reported and a comparison of results between labs is presented. Critical strain energy release rate measurements from SCB tests are also compared with measurements made from an alternative test, namely the double cantilever beam with uneven bending moments (DCB-UBM) test, which has been studied extensively at the Technical University of Denmark and proposed as a mixed-mode test standard. A set of recommendations are made with respect to improving the SCB test and a path to standardization is presented.

Ronald Krueger↗

Estimation of lift losses of hovering vehicles using a single jet

This paper discusses the development of handbook techniques for the preliminary assessment of V/STOL aircraft performance while hovering in the proximity of the ground. In particular, the suckdown forces due to entrainment are described for configurations using a single jet. Corrections to current methods are suggested from an analysis of recent large-scale test data.

Christiansen, R. S.↗

Do Coordinated Knowledge Translation Campaigns Persuade Radiation Oncologists to Use Single-Fraction Radiation Therapy Compared With Multiple-Fraction Radiation Therapy for Bone Metastases?

Although level 1 evidence supports the use of single-fraction radiation therapy (SFRT) compared with multiple-fraction radiation therapy (MFRT) for the palliative management of bone metastases, SFRT is underused. In early 2017, the Canadian Partnership Against Cancer and CancerCare Manitoba undertook a comprehensive knowledge translation campaign in Manitoba, Canada featuring educational outreach visits, local consensus meetings, and audit and feedback interventions to encourage greater use of SFRT. This study assessed the impact of this campaign on SFRT use and identified variables associated with MFRT usage.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Determining valence band offsets in heterojunctions using a single core-level x-ray photoelectron spectrum

The behavior and functionality of semiconductor heterojunctions depend critically on the alignments of the valence and conduction bands at the various interfaces. Traditionally band alignment has been measured by x-ray photoelectron spectroscopy using pairs of distinct core levels, one from each side of the interface, to track the valence band maxima in the two materials. Here, we demonstrate that it is possible to determine band alignment using a single core-level photoelectron spectrum for an element that is common to both materials. The energy splitting between the photoemission features originating in the two materials is shown to be dominated by the difference in electrostatic potential across the interface, leading to a reliable determination of the band alignment.

Wang, Le↗

Assessment of the Damage Tolerance of Postbuckled Hat-Stiffened Panels Using Single-Stringer Specimens

A procedure is proposed for the assessment of the damage tolerance and collapse of stiffened composite panels using a single-stringer compression specimen. The dimensions of the specimen are determined such that the specimen s nonlinear response and collapse are representative of an equivalent multi-stringer panel in compression. Experimental tests are conducted on specimens with and without an embedded delamination. A shell-based finite element model with intralaminar and interlaminar damage capabilities is developed to predict the postbuckling response as well as the damage evolution from initiation to collapse.

Bisagni, Chiara↗

Fiber coupled laser ultrasound system using a single mode hollow core fiber for excitation laser: Theory and demonstration for on-machine thickness gauging

Laser ultrasound (LU) is a technique that uses a pump laser and a probe laser to optically generate and detect elastic waves in a material. Despite its advantages over traditional contact transducer-based ultrasound, industrial adoption has been limited by complex optical setups and the inability of multi-mode fibers to deliver a stable Gaussian profile for the pump laser. Here, we report a fully fiber-coupled thermoelastic LU system that uses an anti-resonant hollow-core single-mode fiber to deliver 1 mJ nanosecond pulses of 1064 nm light, while preserving the fundamental Gaussian mode (pump laser). When combined with a fiber-coupled interferometer (probe laser), a small, flexible, and environmentally robust sensor capable of optically generating and detecting high frequency broadband ultrasound is realized. We demonstrate such an LU system implemented in situ on a four-axis precision lathe. High-resolution thickness gauging is performed, before and after precision cutting, by exciting and measuring a zero-group velocity guided wave mode. The measurements are verified with ex-situ traceable coordinate measuring machine data. Mean absolute deviations of 0.1%, of nominal thickness, before cutting, and 0.2% and 0.3%, after stepped and tapered cuts, respectively, are reported. A theoretical background for thermoelastic ultrasound generation in an elastic waveguide is also presented. Attention is given to the effect of the pump laser profile on wave generation to elucidate the importance of using single-mode laser light. The fiber-coupled system demonstrated is well-suited for use in scientific and engineering sensing applications and facilitates the adoption of LU for industrial non-destructive testing.

Engineering↗

A 200 GHz tripler using a single barrier varactor

The GaAs Schottky varactor diode is the nonlinear device most commonly used for submillimeter wave harmonic generation. Output power adequate to serve as a local oscillator source for SIS tunnel junctions has been demonstrated with whisker-contacted GaAs Schottky varactor multipliers in waveguide mounts up to about 800 GHz. In this paper, we present results for a tripler to 200 GHz using a new multiplier device, the single barrier varactor (SBV). This new varactor has potential advantages such as stronger nonlinearities or special symmetry, which make it attractive for submillimeter wave frequency multiplication. The performance of a tripler using a SBV over a output frequency range from 186 to 207 GHz has been measured in a crossed waveguide mount. The theoretical performance of the device has been calculated using large signal analysis. A comparison of theoretical and measured results and a discussion of various losses in the mount and the varactor have also been presented.

Choudhury, Debabani↗

Temperature and Dynamic Strain Measurements Using a Single SAWR Sensor

Dynamic strain sensing is relevant in numerous applications involving structural health monitoring, condition-based maintenance, operation efficiency preservation, and work environment safety. These sensors are particularly critical for high-temperature (HT) harsh-environment (HE) industries such as aerospace, automotive, power plants, and advanced manufacturing. In HT/HE, sensor implementation and measurement present challenges such as maintaining sensor stability, accounting for temperature cross-sensitivity, providing HT attachment, and packaging of the sensors and system. Surface acoustic wave resonator (SAWR) sensors can address these needs and offer additional benefits such as compact size and wireless interrogation capability. The SAWR sensitivity to dynamic strain is temperature dependent, making it necessary to measure the sensor temperature in order to use the correct dynamic strain calibration curve. In this work, a method for determining the temperature, dynamic strain magnitude, and dynamic strain spectral components using a single SAWR sensor is presented. Here, the established technique for determining operational temperature and dynamic strain magnitude/spectral components using only one SAWR simplifies the sensor measurement system, thus being very attractive for HT /HE applications.

47 OTHER INSTRUMENTATION↗

Component pose reconstruction using a single robotic total station for panelized building envelopes

The construction industry can benefit greatly from increased automation in construction processes in terms of precision, time, and labor costs. This is especially true for prefabricated construction for either new buildings or envelope retrofits. Here, prefabricated components are manufactured offsite according to design specifications and installed onsite. Accurate information on the component’s position and orientation (pose) is needed to achieve this. A tool named “Real-Time Evaluator” (RTE), designed to autonomously track prefabricated components as they are being installed and provide real-time installation instructions, is currently under development using a single robotic total station. This is challenging since at least three points are needed to determine the pose of an object in space. To achieve this goal with a single robotic total station, two key algorithms were developed: the “resection” algorithm aligns the digital twin with the physical twin regardless of the location of the total station, and the “transformation” algorithm gives instructions of translations and rotations to installers to achieve the desired installation pose. The algorithms were evaluated experimentally on a lab-scale demonstration. Results show that the resection algorithm achieved an average error of < 3.1 mm, while the transformation algorithm predicted the rotation angle along a single axis with an error of < 0.5◦.

Tang, Mengjia↗

Time-stamping and counting of single photons using fast camera

I will discuss fast optical cameras based on the back-illuminated silicon sensor and Timepix3 ASIC. The sensor has high quantum efficiency, and the chip provides nanosecond scale time resolution and data-driven readout with 80Mpix/sec bandwidth. The intensified version of the camera is single photon sensitive and since recently has been used for registration of single photons in a variety of quantum information science and quantum imaging experiments as well as for other applications. We briefly review the camera and describe recent experiments with a Hong-Ou-Mandel interferometer to characterize its photon counting capabilities.

79 ASTRONOMY AND ASTROPHYSICS↗

Interleaved dual-species arrays of single atoms using a passive optical element and one trapping laser

We demonstrate trapping of individual rubidium (Rb) and cesium (Cs) atoms in an interleaved array of bright tweezers and dark bottle-beam traps, using a microfabricated optical element illuminated by a single-laser beam and a 4f system with spatial filtering. Our approach exploits the opposite-sign dynamic polarizabilities of Rb and Cs, ensuring that each species is exclusively trapped in either bright or dark sites. The passive optical mask creates optimal trap depths for both species using three transmittance levels while minimizing the optical phase difference, implemented using a variable-thickness absorbing layer of amorphous germanium. This trapping architecture achieves atom loading rates close to 50% while reducing system complexity compared to conventional methods using active optoelectronic components and/or multiple-laser wavelengths.

Fang, Chengyu [Univ. of Wisconsin, Madison, WI (Un↗

Radiation Protection Using Single-Wall Carbon Nanotube Derivatives

This invention is a means of radiation protection, or cellular oxidative stress mitigation, via a sequence of quenching radical species using nano-engineered scaffolds, specifically single-wall carbon nanotubes (SWNTs) and their derivatives. The material can be used as a means of radiation protection by reducing the number of free radicals within, or nearby, organelles, cells, tissue, organs, or living organisms, thereby reducing the risk of damage to DNA and other cellular components (i.e., RNA, mitochondria, membranes, etc.) that can lead to chronic and/or acute pathologies, including but not limited to cancer, cardiovascular disease, immuno-suppression, and disorders of the central nervous system. In addition, this innovation could be used as a prophylactic or antidote for accidental radiation exposure, during high-altitude or space travel where exposure to radiation is anticipated, or to protect from exposure from deliberate terrorist or wartime use of radiation- containing weapons.

Tour, James M.↗

Utilizing GPS to Determine Ionospheric Delay over the Ocean

Several spaceborne altimeters have been built and flown, and others are being developed to provide measurements of ocean and ice sheet topography. Until the launch of TOPEX, altimeters were single frequency systems incapable of removing the effects of ionospheric delay on the radar pulse. With the current state of the art in satellite altimetry, the ionosphere causes the largest single error when using single frequency altimeters. Ionospheric models provide the only recourse short of adding a second frequency to the altimeter. Unfortunately, measurements of the ionosphere are lacking over the oceans or ice sheets where they are most needed. A possible solution to the lack of data density may result from an expanded use of the Global Positioning System (GPS). This paper discusses how the reflection of the GPS signal from the ocean can be used to extend ionospheric measurements by simply adding a GPS receiver and downward-pointing antenna to satellites carrying single frequency altimeters. This paper presents results of a study assessing the feasibility and effectiveness of adding a GPS receiver and downward-pointing antenna to satellites carrying single frequency altimeters.

Katzberg, Stephen J.↗