Search NASA⌕ Search

SEARCH · Search NASA

Results for “Soft Error Detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

SU-E-I-72: First Experimental Study of On-Board CBCT Imaging Using 2.5MV Beam On a Radiotherapy Linac

Purpose: Varian TrueBeam version 2.0 comes with a new inline 2.5MV beam modality for image guided patient setup. In this work we develop an iterative volumetric image reconstruction technique specific to the beam and investigate the possibility of obtaining metal artifact free CBCT images using the new imaging modality. Methods: An iterative reconstruction algorithm with a sparse representation constraint based on dictionary learning is developed, in which both sparse projection and low dose rate (10 MU/min) are considered. Two CBCT experiments were conducted using the newly available 2.5MV beam on a Varian TrueBeam linac. First, a Rando anthropomorphic head phantom with and without a copper bar inserted in the center was scanned using both 2.5MV and kV (100kVp) beams. In a second experiment, an MRI phantom with many coils was scanned using 2.5MV, 6MV, and kV (100kVp) beams. Imaging dose and the resultant image quality is studied. Results: Qualitative assessment suggests that there were no visually detectable metal artifacts in MV CBCT images, compared with significant metal artifacts in kV CBCT images, especially in the MRI phantom. For a region near the metal object in the head phantom, the 2.5MV CBCT gave a more accurate quantification of the electron density compared with kV CBCT, with a ∼50% reduction in mean HU error. As expected, the contrast between bone and soft-tissue in 2.5MV CBCT decreased compared with kV CBCT. Conclusion: On-board CBCT imaging with the new 2.5MV beam can effectively reduce metal artifacts, although with a reduced softtissue contrast. Combination of kV and MV scanning may lead to metal artifact free CBCT images with uncompromised soft-tissue contrast.

60 APPLIED LIFE SCIENCES↗

THE SWIFT BURST ALERT TELESCOPE PERSPECTIVE ON NON-THERMAL EMISSION IN HIFLUGCS GALAXY CLUSTERS

The search for diffuse non-thermal, inverse Compton (IC) emission from galaxy clusters at hard X-ray energies has been underway for many years, with most detections being either of low significance or controversial. In this work, we investigate 14-195 keV spectra from the Swift Burst Alert Telescope (BAT) all-sky survey for evidence of non-thermal excess emission above the exponentially decreasing tail of thermal emission in the flux-limited HIFLUGCS sample. To account for the thermal contribution at BAT energies, XMM-Newton EPIC spectra are extracted from coincident spatial regions so that both thermal and non-thermal spectral components can be determined simultaneously. We find marginally significant IC components in six clusters, though after closer inspection and consideration of systematic errors we are unable to claim a clear detection in any of them. The spectra of all clusters are also summed to enhance a cumulative non-thermal signal not quite detectable in individual clusters. After constructing a model based on single-temperature fits to the XMM-Newton data alone, we see no significant excess emission above that predicted by the thermal model determined at soft energies. This result also holds for the summed spectra of various subgroups, except for the subsample of clusters with diffuse radio emission. For clusters hosting a diffuse radio halo, a relic, or a mini-halo, non-thermal emission is initially detected at the {approx}5{sigma} confidence level-driven by clusters with mini-halos-but modeling and systematic uncertainties ultimately degrade this significance. In individual clusters, the non-thermal pressure of relativistic electrons is limited to {approx}< 10% of the thermal electron pressure, with stricter limits for the more massive clusters, indicating that these electrons are likely not dynamically important in the central regions of clusters.

79 ASTRONOMY AND ASTROPHYSICS↗

A Tale of Two Transients: GW 170104 and GRB 170105A

We present multi-wavelength follow-up campaigns by the AstroSat CZTI and GROWTH collaborations in search of an electromagnetic counterpart to the gravitational wave event GW 170104. At the time of the GW 170104 trigger, the AstroSat CZTI field of view covered 50.3% of the sky localization. We do not detect any hard X-ray (>100 keV) signal at this time, and place an upper limit of ≈4.5×10{sup −7} erg cm{sup −2} s{sup −1}, for a 1 s timescale. Separately, the ATLAS survey reported a rapidly fading optical source dubbed ATLAS17aeu in the error circle of GW 170104. Our panchromatic investigation of ATLAS17aeu shows that it is the afterglow of an unrelated long, soft GRB 170105A, with only a fortuitous spatial coincidence with GW 170104. We then discuss the properties of this transient in the context of standard long GRB afterglow models.

79 ASTRONOMY AND ASTROPHYSICS↗

A Possible Cyclotron Line Signature from Quiescent Gamma-Ray Burst Counterparts

If gamma-ray bursts are associated with isolated, magnetized neutron stars in the Galaxy, they may be accreting directly from the interstellar medium after the burst event. In addition to a soft thermal component (T(sub e) approx. 100 eV), we predict that the faint quiescent emission spectra from these sources will possess a unique nonthermal signature: for magnetic field strengths B approx. equal to(0.7-7) x 10(exp 12) G, approx. 0.5-5% of the total luminosity could be emitted in a narrow (E/Delta E approx. 2-4) cyclotron emission line which peaks between approx. 5-20 keV below the cyclotron resonance energy (E(sub B) = 11.6(B/10(exp 12) G) keV). Unlike the soft thermal emission, this hard cyclotron component will not be strongly absorbed by the intervening H I gas. For stars with B approx. 10(exp 12) G, this nonthermal feature should be detectable by the instruments onboard ASCA and on the next generation of X-ray satellites (e.g., ASTRO-E). We therefore propose that deep X-ray images be taken on gamma-ray burst sources with excellent positions (error boxes less than or approx. equal to l') such as is being planned for GRB920501 to look for this feature. A positive detection would strongly suggest that at least some of the gamma-ray bursters are associated with isolated, magnetized neutron stars in the Galaxy.

Wang, John C. L.↗

Computing in the presence of soft bit errors

It is shown that single-event-upsets (SEUs) due to cosmic rays are a significant source of single bit error in spacecraft computers. The physical mechanism of SEU, electron hole generation by means of Linear Energy Transfer (LET), it discussed with reference made to the results of a study of the environmental effects on computer systems of the Galileo spacecraft. Techniques for making software more tolerant of cosmic ray effects are considered, including: reducing the number of registers used by the software; continuity testing of variables; redundant execution of major procedures for error detection; and encoding state variables to detect single-bit changes. Attention is also given to design modifications which may reduce the cosmic ray exposure of on-board hardware. These modifications include: shielding components operating in LEO; removing low-power Schottky parts; and the use of CMOS diodes. The SEU parameters of different electronic components are listed in a table.

Rasmussen, R. D.↗

The accreting black hole Swift J1753.5–0127 from radio to hard X-ray

We report on multiwavelength measurements of the accreting black hole Swift J1753.5–0127 in the hard state at low luminosity (L ∼ 2.7 × 10{sup 36} erg s{sup −1} assuming a distance of d = 3 kpc) in 2014 April. The radio emission is optically thick synchrotron, presumably from a compact jet. We take advantage of the low extinction (E(B−V)=0.45 from earlier work) and model the near-IR to UV emission with a multitemperature disk model. Assuming a black hole mass of M{sub BH} = 5 M{sub ⊙} and a system inclination of i = 40°, the fits imply an inner radius for the disk of R{sub in}/R{sub g} > 212d{sub 3}(M{sub BH}/5 M{sub ⊙}){sup −1}, where R{sub g} is the gravitational radius of the black hole and d{sub 3} is the distance to the source in units of 3 kpc. The outer radius is R{sub out}/R{sub g}=90,000 d{sub 3}(M{sub BH}/5 M{sub ⊙}){sup −1}, which corresponds to 6.6 × 10{sup 10} d{sub 3} cm, consistent with the expected size of the disk given previous measurements of the size of the companion's Roche lobe. The 0.5–240 keV energy spectrum measured by Swift/X-ray Telescope (XRT), Suzaku (XIS, PIN, and GSO), and Nuclear Spectroscopic Telescope Array is relatively well characterized by an absorbed power law with a photon index of Γ = 1.722 ± 0.003 (90% confidence error), but a significant improvement is seen when a second continuum component is added. Reflection is a possibility, but no iron line is detected, implying a low iron abundance. We are able to fit the entire (radio to 240 keV) spectral energy distribution (SED) with a multitemperature disk component, a Comptonization component, and a broken power law, representing the emission from the compact jet. The broken power law cannot significantly contribute to the soft X-ray emission, and this may be related to why Swift J1753.5–0127 is an outlier in the radio/X-ray correlation. The broken power law (i.e., the jet) might dominate above 20 keV, which would constrain the break frequency to be between 2.4 × 10{sup 10} and 3.6 × 10{sup 12} Hz. Although the fits to the full SED do not include significant thermal emission in the X-ray band, previous observations have consistently seen such a component, and we find that there is evidence at the 3.1σ level for a disk-blackbody component with a temperature of kT{sub in}=150{sub −20}{sup +30} eV and an inner radius of 5R{sub g}–14R{sub g}. If this component is real, it might imply the presence of an inner optically thick accretion disk in addition to the strongly truncated (R{sub in}> 212R{sub g}) disk. We also perform X-ray timing analysis, and the power spectrum is dominated by a Lorentzian component with ν{sub max} = 0.110 ± 0.003 Hz and ν{sub max} = 0.16 ± 0.04 Hz as measured by XIS and XRT, respectively.

79 ASTRONOMY AND ASTROPHYSICS↗

Refinement of Treatment Setup and Target Localization Accuracy Using Three-Dimensional Cone-Beam Computed Tomography for Stereotactic Body Radiotherapy

Purposes: To quantitatively compare two-dimensional (2D) orthogonal kV with three-dimensional (3D) cone-beam CT (CBCT) for target localization; and to assess intrafraction motion with kV images in patients undergoing stereotactic body radiotherapy (SBRT). Methods and Materials: A total of 50 patients with 58 lesions received 178 fractions of SBRT. After clinical setup using in-room lasers and skin/cradle marks placed at simulation, patients were imaged and repositioned according to orthogonal kV/MV registration of bony landmarks to digitally reconstructed radiographs from the planning CT. A subsequent CBCT was registered to the planning CT using soft tissue information, and the resultant 'residual error' was measured and corrected before treatment. Posttreatment 2D kV and/or 3D CBCT images were compared with pretreatment images to determine any intrafractional position changes. Absolute averages, statistical means, standard deviations, and root mean square (RMS) values of observed setup error were calculated. Results: After initial setup to external marks with laser guidance, 2D kV images revealed vector mean setup deviations of 0.67 cm (RMS). Cone-beam CT detected residual setup deviations of 0.41 cm (RMS). Posttreatment imaging demonstrated intrafractional variations of 0.15 cm (RMS). The individual shifts in three standard orthogonal planes showed no obvious directional biases. Conclusions: After localization based on superficial markings in patients undergoing SBRT, orthogonal kV imaging detects setup variations of approximately 3 to 4 mm in each direction. Cone-beam CT detects residual setup variations of approximately 2 to 3 mm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analysis of a GaN-Based CRM Totem-Pole PFC Converter Considering Current Sensing Delay

High-frequency soft-switched gallium-nitride (GaN) based critical conduction mode (CRM) totem-pole power factor correction (PFC) converter is one of the most potential candidates in data center power supplies. However, the high-speed cycle-by-cycle zero current detection (ZCD) brings challenges to zero-voltage-switching (ZVS) control. Current sensing delay (CSD) exists, and the ZCD circuit is sensitive to high di/dt switching noise. In this paper, mechanisms of the ZCD time error are elaborated, and impacts of the current sensing delay on converter switching frequency, inductor current, input current third harmonic distortion (THD), and power loss are analyzed. Qualification time is added within the controller for immunity to the swiching noise, and a CSD embedded converter model is proposed to compensate the ZCD time delay. Also, loss modeling of the CRM totem-pole PFC is conducted to aid in analysis of the proposed theory. A 1.5 kW single-phase CRM totem-pole PFC prototype is tested. Experimental results validiate the analysis, modeling, and the proposed compensation method for current sensing delay.

Sun, Jingjing↗

INTEGRAL Detection of the First Prompt Gamma-Ray Signal Coincident with the Gravitational-wave Event GW170817

We report the INTernational Gamma-ray Astrophysics Laboratory ( INTEGRAL ) detection of the short gamma-ray burst GRB 170817A (discovered by Fermi -GBM) with a signal-to-noise ratio of 4.6, and, for the first time, its association with the gravitational waves (GWs) from binary neutron star (BNS) merging event GW170817 detected by the LIGO and Virgo observatories. The significance of association between the gamma-ray burst observed by INTEGRAL and GW170817 is 3.2σ, while the association between the Fermi -GBM and INTEGRAL detections is 4.2σ. GRB 170817A was detected by the SPI-ACS instrument about 2 s after the end of the GW event. We measure a fluence of (1.4 ± 0.4 ± 0.6) × 10{sup −7} erg cm{sup −2} (75–2000 keV), where, respectively, the statistical error is given at the 1σ confidence level, and the systematic error corresponds to the uncertainty in the spectral model and instrument response. We also report on the pointed follow-up observations carried out by INTEGRAL , starting 19.5 hr after the event, and lasting for 5.4 days. We provide a stringent upper limit on any electromagnetic signal in a very broad energy range, from 3 keV to 8 MeV, constraining the soft gamma-ray afterglow flux to <7.1 × 10{sup −11} erg cm{sup −2} s{sup −1} (80–300 keV). Exploiting the unique capabilities of INTEGRAL , we constrained the gamma-ray line emission from radioactive decays that are expected to be the principal source of the energy behind a kilonova event following a BNS coalescence. Finally, we put a stringent upper limit on any delayed bursting activity, for example, from a newly formed magnetar.

79 ASTRONOMY AND ASTROPHYSICS↗

Soft Decision Analyzer

The Soft Decision Analyzer (SDA) is an instrument that combines hardware, firmware, and software to perform realtime closed-loop end-to-end statistical analysis of single- or dual- channel serial digital RF communications systems operating in very low signal-to-noise conditions. As an innovation, the unique SDA capabilities allow it to perform analysis of situations where the receiving communication system slips bits due to low signal-to-noise conditions or experiences constellation rotations resulting in channel polarity in versions or channel assignment swaps. SDA s closed-loop detection allows it to instrument a live system and correlate observations with frame, codeword, and packet losses, as well as Quality of Service (QoS) and Quality of Experience (QoE) events. The SDA s abilities are not confined to performing analysis in low signal-to-noise conditions. Its analysis provides in-depth insight of a communication system s receiver performance in a variety of operating conditions. The SDA incorporates two techniques for identifying slips. The first is an examination of content of the received data stream s relation to the transmitted data content and the second is a direct examination of the receiver s recovered clock signals relative to a reference. Both techniques provide benefits in different ways and allow the communication engineer evaluating test results increased confidence and understanding of receiver performance. Direct examination of data contents is performed by two different data techniques, power correlation or a modified Massey correlation, and can be applied to soft decision data widths 1 to 12 bits wide over a correlation depth ranging from 16 to 512 samples. The SDA detects receiver bit slips within a 4 bits window and can handle systems with up to four quadrants (QPSK, SQPSK, and BPSK systems). The SDA continuously monitors correlation results to characterize slips and quadrant change and is capable of performing analysis even when the receiver under test is subjected to conditions where its performance degrades to high error rates (30 percent or beyond). The design incorporates a number of features, such as watchdog triggers that permit the SDA system to recover from large receiver upsets automatically and continue accumulating performance analysis unaided by operator intervention. This accommodates tests that can last in the order of days in order to gain statistical confidence in results and is also useful for capturing snapshots of rare events.

Steele, Glen↗

EUV emission from a sample of Active Galactic Nuclei

Active Galactic Nuclei (AGN) emit a substantial fraction of their total radiated power in the EUV passband, because spectroscopically this band is situated at or near the peak of the 'big blue bump,' which is bounded on either side by the UV and soft X-ray excesses. Owing to the lack of observational data, the shape of AGN spectra in the EUV is not well known. This paper presents broad band (65-190 eV) count rates of 11 AGN detected by the Extreme Ultraviolet Explorer (EUVE). Assuming a power law spectral shape for the EUV and soft X-ray energies, we demonstrate that the photon indices of the sources are considerably steeper than typical AGN indices. For 6 sources where ROSAT data are available to provide a more precise determination of their spectral parameters in the 0.1-2.5 keV range, we have used these parameters to compute predicted EUVE count rates and compared them with the observed values. The two sets of quantities agree to within experimental error. We conclude that there is no evidence of spectral steepening or turn-over of the soft X-ray excess at EUV wavelengths for a sample of AGN which covers a wide range of brightness.

Lieu, R.↗

A method for correcting aspect solution errors in ROSAT HRI observations of compact sources

X-ray point sources observed with the ROSAT High Resolution Imager (HRI) often appear elongated over scales of approximately 5 sec-10 sec from the image core. This elongation has been attributed to errors in the attitude correction as the satellite is wobbled during the observations, and affects sources with both soft and hard X-ray spectra. In this paper, I report the results of an attempt to rid a high signal-to-noise observation of the soft X-ray point source HZ 43 of its characteristic elongation. I divided the observation into 181 separate images, each containing photons from only a small region on the detector through which the source passed during the satellite's wobble. By measuring the positions of the individual image centroids, I found clear evidence for systematic offsets from a common mean by up to approximately +/- 3 sec in both right ascension and declination as a function of phase in the satellite wobble. Shifting the subimages to a common center and then restacking them into a single image measurably improved the symmetry of the point-spread function. HRI observations are wobbled primarily to smooth out variations in the pixel-to-pixel sensitivity of the detector and also to extend the lifetime of the microchannel plates in the detector since these decay at a given location as a function of the number of photons detected. However, the elongations introduced by the aspect errors inhibit the identification of possible extended X-ray emission associated with sources such as pulsars and active galactic nuclei. In light of these results, I suggest that until the aspect errors are understood, observations of compact sources, where this effect may be important, should not be wobbled.

Morse, Jon A.↗

Radiation-Tolerant Intelligent Memory Stack - RTIMS

This innovation provides reconfigurable circuitry and 2-Gb of error-corrected or 1-Gb of triple-redundant digital memory in a small package. RTIMS uses circuit stacking of heterogeneous components and radiation shielding technologies. A reprogrammable field-programmable gate array (FPGA), six synchronous dynamic random access memories, linear regulator, and the radiation mitigation circuits are stacked into a module of 42.7 42.7 13 mm. Triple module redundancy, current limiting, configuration scrubbing, and single- event function interrupt detection are employed to mitigate radiation effects. The novel self-scrubbing and single event functional interrupt (SEFI) detection allows a relatively soft FPGA to become radiation tolerant without external scrubbing and monitoring hardware

Ng, Tak-kwong↗

Elemental-sensitive Detection of the Chemistry in Batteries through Soft X-ray Absorption Spectroscopy and Resonant Inelastic X-ray Scattering

Energy storage has become more and more a limiting factor of today's sustainable energy applications, including electric vehicles and green electric grid based on volatile solar and wind sources. The pressing demand of developing high-performance electrochemical energy storage solutions, i.e., batteries, relies on both fundamental understanding and practical developments from both the academy and industry. The formidable challenge of developing successful battery technology stems from the different requirements for different energy-storage applications. Energy density, power, stability, safety, and cost parameters all have to be balanced in batteries to meet the requirements of different applications. Therefore, multiple battery technologies based on different materials and mechanisms need to be developed and optimized. Incisive tools that could directly probe the chemical reactions in various battery materials are becoming critical to advance the field beyond its conventional trial-and-error approach. Here, we present detailed protocols for soft X-ray absorption spectroscopy (sXAS), soft X-ray emission spectroscopy (sXES), and resonant inelastic X-ray scattering (RIXS) experiments, which are inherently elemental-sensitive probes of the transition-metal 3d and anion 2p states in battery compounds. We provide the details on the experimental techniques and demonstrations revealing the key chemical states in battery materials through these soft X-ray spectroscopy techniques.

25 ENERGY STORAGE↗

FERMI Observations of Gamma -Ray Emission From the Moon

We report on the detection of high-energy γ -ray emission from the Moon during the first 24 months of observations by the Fermi Large Area Telescope (LAT). This emission comes from particle cascades produced by cosmicray (CR) nuclei and electrons interacting with the lunar surface. The differential spectrum of the Moon is soft and can be described as a log-parabolic function with an effective cutoff at 2-3 GeV, while the average integral flux measured with the LAT from the beginning of observations in 2008 August to the end of 2010 August is F(greater than100 MeV) = (1.04 plus or minus 0.01 [statistical error] plus or minus 0.1 [systematic error]) × 10(sup −6) cm(sup −2) s(sup −1). This flux is about a factor 2-3 higher than that observed between 1991 and 1994 by the EGRET experiment on board the Compton Gamma Ray Observatory, F(greater than100 MeV)≈5×10(sup −7) cm(sup −2) s(sup −1), when solar activity was relatively high. The higher gamma -ray flux measured by Fermi is consistent with the deep solar minimum conditions during the first 24 months of the mission, which reduced effects of heliospheric modulation, and thus increased the heliospheric flux of Galactic CRs. A detailed comparison of the light curve with McMurdo Neutron Monitor rates suggests a correlation of the trends. The Moon and the Sun are so far the only known bright emitters of gamma-rays with fast celestial motion. Their paths across the sky are projected onto the Galactic center and high Galactic latitudes as well as onto other areas crowded with high-energy gamma-ray sources. Analysis of the lunar and solar emission may thus be important for studies of weak and transient sources near the ecliptic.

fermi↗

Improving the performance of soft decision Viterbi decoding in a non-Gaussian environment through non-linear quantization

The performance of Viterbi decoding in a non-Gaussian environment is investigated using a nonlinear quantization strategy. The channel model consists of a convolutionally encoded BPSK signal transmitted to a satellite where it is corrupted with additive white Gaussian noise and pulsed radio frequency interference (RFI). The resultant signal is then passed through a satellite nonlinearity and transmitted to a ground station where it is coherently detected. Interleaving is assumed in order to make the channel memoryless. The presence of RFI makes the channel statistics non-Gaussian, leading to a nonlinear log-likelihood function. A near optimum quantization scheme is found by maximizing a channel parameter, or by matching the quantizer to the log-likelihood function in a mean square error sense. Bit error rate performance improvement is achieved by using such nonlinear quantization.

Mcgregor, D. N.↗

Discovery of soft X-ray flux from 2A 1102+384 = Markarian 421

During April 1976 a soft X-ray flux was detected with SAS 3 from the vicinity of 2A 1102+384. The average flux densities were 4.3 x 10 to the -11th and 14 x 10 to the -11th erg/sq cm per sec in the energy bands 0.1-0.28 keV and 1-6 keV, respectively. There is an indication of variability over about 0.5 day in the lowest energy band. An upper limit of 3 x 10 to the 20th H atoms per sq cm is found for the gas column density to the X-ray source. In May 1978, observations with the modulation collimators of SAS 3 yielded an accurate (40 arcsec error radius) position for the X-ray source (2-6 keV) at right ascension 11 h 1 m 39.7 s, declination + 38 deg 28 min 51 sec (equinox 1950). The earlier tentative identification by Ricketts et al. (1976) with the BL Lacertae object B2 1101+38 = Markarian 421 is thus confirmed.

Hearn, D. R.↗

Extended soft X-ray emission in Seyfert galaxies: ROSAT HRI observations of NGC 3516, NGC 4151, and Markarian 3

We have used the ROSAT High Resolution Imager (HRI) to examine the distribution of soft X-rays in three nearby Seyfert galaxies with approximately 4 to 5 arcsecs FWHM spatial resolution. A feature of our analysis is an attempt to remove errors in the aspect solution using a method developed by one of us (J.M.). NGC 4151 shows resolved X-ray emission that is spatially correlated with the optical extended narrow-line region (ENLR), confirming the results obtained with the Einstein HRI by Elvis, Briel, & Henry. NGC 3516 is elongated along a position angle of approximately 40 to 220 deg, similar to the direction of the Z-shaped narrow-line region. MRK 3 is very faint in our HRI image and is probably spatially unresolved. We detect the faint X-ray source approximately 2 arcmins west of the MRK 3 nucleus previously found by Turner, Urry, & Mushotzky. We also detected the BL Lac object BL 1207 + 39 approximately 5 arcmins north-northwest of NGC 4151. This object appears spatially unresolved, but some excess X-ray emission may be observed in the azimuthally averaged radial brightness profile of BL 1207 + 39 between radii of 10 arcsecs and 30 arcsecs when compared to a calibration source. A much deeper image is necessary to confirm this result.

Morse, Jon A.↗