Search NASA⌕ Search

SEARCH · Search NASA

Results for “Soft thresholding”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

THE IBIS SOFT GAMMA-RAY SKY AFTER 1000 INTEGRAL ORBITS

Here we report an all-sky soft gamma-ray source catalog based on IBIS observations performed during the first 1000 orbits of INTEGRAL. The database for the construction of the source list consists of all good-quality data available, from the launch in 2002, up to the end of 2010. This corresponds to ∼110 Ms of scientific public observations, with a concentrated coverage on the Galactic Plane and extragalactic deep exposures. This new catalog includes 939 sources above a 4.5σ significance threshold detected in the 17–100 keV energy band, of which 120 sources represent previously undiscovered soft gamma-ray emitters. The source positions are determined, mean fluxes are provided in two main energy bands, and these are both reported together with the overall source exposure. Indicative levels of variability are provided, and outburst times and durations are given for transient sources. A comparison is made with previous IBIS catalogs and catalogs from other similar missions.

79 ASTRONOMY AND ASTROPHYSICS↗

Soft syndrome iterative decoding of quantum LDPC codes and hardware architectures

In practical quantum error correction implementations, the measurement of syndrome information is an unreliable step—typically modeled as a binary measurement outcome flipped with some probability. However, the measured syndrome is in fact a discretized value of the continuous voltage or current values obtained in the physical implementation of the syndrome extraction. In this paper, we use this “soft” or analog information to benefit iterative decoders for decoding quantum low-density parity-check (QLDPC) codes. Syndrome-based iterative belief propagation decoders are modified to utilize the soft syndrome to correct both data and syndrome errors simultaneously. We demonstrate the advantages of the proposed scheme not only in terms of comparison of thresholds and logical error rates for quasi-cyclic lifted-product QLDPC code families but also with faster convergence of iterative decoders. Additionally, we derive hardware (FPGA) architectures of these soft syndrome decoders and obtain similar performance in terms of error correction to the ideal models even with reduced precision in the soft information. The total latency of the hardware architectures is about 600 ns (for the QLDPC codes considered) in a 20 nm CMOS process FPGA device, and the area overhead is almost constant—less than 50% compared to min-sum decoders with noisy syndromes.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Ultrafast photoionization dynamics at high laser intensities in the xuv regime

We study the ionization dynamics in the soft-x-ray regime for high intensities and short pulses for excitations near the ionization threshold. Using a one-dimensional helium atom model, we compare exact numerical solutions with time-dependent Hartree-Fock results in order to identify the role of electron-electron correlations. At moderate intensities but still in the x-ray and short-pulse regime, we find that the Hartree-Fock theory reproduces well the dynamics of the ground-state occupation, while at high intensities strong correlation effects occur for excitations close to the threshold. From their characteristic momentum distributions, we can identify contributions to the double ionization from sequential three-photon and nonsequential or sequential two-photon processes. At elevated intensities these contributions deviate from their usual intensity scaling due to saturation effects, even though the total double-ionization probability stays below 10%. Furthermore, analysis of the time evolution of the momentum distribution reveals signatures of the energy-time uncertainty which indicate a coherent regime of the dynamics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Impulsive phase Fe K-alpha emission in a flare of 1989 March

Evidence for enhanced Fe K-alpha line emission that is coincident (to within 15 s) of an intense hard X-ray (greater than 50 keV) burst is presented on the basis of observations of the Fe K-alpha soft X-ray line made with the SMM. Three different models for explaining the K-alpha enhancement are investigated, namely, photoexcitation by soft X-ray thermal bremsstrahlung radiation from an isothermal source, collisional excitation by nonthermal thick-target electrons, and photoexcitation by a nonthermal hard X-ray flux distribution which extends with a power-law spectrum down to the Fe K-alpha ionization threshold at 7.1 keV. It is found that, to within the limits of isothermal temperature and emission measure set by soft X-ray observations, the thermal photoexcitation model cannot reproduce satisfactorily the intensity of enhanced K-alpha emission during the hard X-ray impulsive phase. The impulsive phase K-alpha flux exceeds that predicted by the thermal photoexcitation model by about 3 sigma. The implications of these results for the nonthermal interpretation of impulsive hard X-ray bursts in solar flares are discussed.

Zarro, D. M.↗

How Can The SN-GRB Time Delay Be Measured?

The connection between SNe and GRBs, launched by SN 1998bw / GRB 980425 and clinched by SN 2003dh / GRB 030329-with the two GRBs differing by a factor of approximately 50000 in luminosity-so far suggests a rough upper limit of approximately 1-2 days for the delay between SN and GRB. Only four SNe have had nonnegligible coverage in close coincidence with the initial explosion, near the W shock breakout: two Qpe II, and two Type IC, SN 1999ex and SN 1998bw. For the latter, only a hint of the minimum between the UV maximum and the radioactivity bump served to help constrain the interval between SN and GRB. Swift GRB alerts may provide the opportunity to study many SNe through the UV breakout phase: GRB 980425 look dikes -apparently nearby, low- luminosity, soft-spectrum, long-lag GRBs-accounted for half of BATSE bursts near threshold, and may dominate the Swift yield near threshold, since it has sensitivity to lower energies than did BATSE. The SN to GRB delay timescale should be better constrained by prompt UV/optical observations alerted by these bursts. Definitive delay measurements may be obtained if long-lag bursters are truly nearby: The SNe/GRBs could emit gravitational radiation detectable by LIGO-II if robust non-axisymmetric bar instabilities develop during core collapse, and/or neutrino emission may be detectable as suggested by Meszaros et al.

Norris, J. P.↗

X-ray diffraction gratings: Precise control of ultra-low blaze angle via anisotropic wet etching

Diffraction gratings are used from micron to nanometer wavelengths as dispersing elements in optical instruments. At shorter wavelengths, crystals can be used as diffracting elements, but due to the 3D nature of the interaction with light are wavelength selective rather than wavelength dispersing. There is an urgent need to extend grating technology into the x-ray domain of wavelengths from 1 to 0.1 nm, but this requires the use of gratings that have a faceted surface in which the facet angles are very small, typically less than 1°. Small facet angles are also required in the extreme ultra-violet and soft x-ray energy ranges in free electron laser applications, in order to reduce power density below a critical damage threshold. In this work, we demonstrate a technique based on anisotropic etching of silicon designed to produce very small angle facets with a high degree of perfection.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A finite viscoelastic constitutive model for low to high strain rate response of elastomers with application of strain rate-induced glass transition

Amorphous elastomers exhibit significant rate-stiffening and unique viscous flow characteristics across a wide range of strain rates, often undergoing glass transition above a strain rate threshold. We have developed a thermodynamically-consistent and micromechanically-inspired constitutive model for soft elastomeric materials to capture the rate-dependent stress-strain behavior and hysteresis when subjected to low to high strain rates. Here, our proposed constitutive model encapsulates the viscous flow of materials through molecular motion at low strain rates and local rearrangement and alignment of the molecules trying to overcome the intermolecular resistance at high strain rates, essentially covering the glass transition. We applied our constitutive model to uniaxial compression experiments performed at low and high strain rates for polyborosiloxane (PBS) to identify the material parameters, and subsequently, performed numerical simulations of single and multi-cycle compression, stress relaxation, and small amplitude oscillatory tension-compression. Our analyses indicate that the model predicts higher total energy dissipation with increasing strain rate; however, dissipation associated with molecular relaxation decreases (forming a cusp) because, beyond a crossover strain rate, intermolecular rearrangement and alignment become dominant, which is consistent with the onset of the glass transition. For cyclic loading-unloading, we observed that dissipation over a cycle remains constant at low strain rates but decreases non-monotonically at high strain rates before becoming constant, with the peak stress over the cycle becoming higher, which can be interpreted as more loading being carried elastically by the polymer network as the intermolecular rearrangement process occurs. Additionally, our model was able to predict the qualitative nature of the storage modulus and loss modulus in the limit of small strain over a wide range of frequency sweeps.

36 MATERIALS SCIENCE↗

Impact of composition and symmetry energy on the temperature of quasiprojectiles simulated with antisymmetrized molecular dynamics

The equation of state describes the emergent physical properties of matter. Experimental data is needed to help constrain the equation of state for nuclear matter. These constraints can help distinguish between an “asy-stiff” and an “asy-soft” equation of state, which has astrophysical implications. One path to help constrain the models is to analyze the nuclear caloric curve; some experiments have shown dependence on neutron excess, and may thus be sensitive to the asymmetry. A difference in the caloric curve based on the asymmetry of the reconstructed quasiprojectile (QP) had been observed using 70 Zn on 70 Zn at 35 MeV/nucleon taken with the NIMROD array. Antisymmetrized molecular dynamics calculations were performed for the same system and deexcited with gemini++. Both Gogny (asy-soft) and Gogny-as (asy-stiff) data sets were generated. The particles were then filtered based on detector geometric acceptance and thresholds. From the accepted particles, the excitation energy and temperature were calculated in the same way as for experimental data. Additionally, filter effects on the observed nuclear caloric curves were investigated. A tendency for the asy-stiff nuclear caloric curves to have higher temperatures than their asy-soft counterparts was observed for a number of probes. In addition, some probes may show sensitivity to the reconstructed composition of the QP, but this is inconclusive due to high statistical fluctuations and a large dependence on the exact method of event selection.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Soft Syndrome Decoding of Quantum LDPC Codes for Joint Correction of Data and Syndrome Errors

Quantum errors are primarily detected and corrected using the measurement of syndrome information which itself is an unreliable step in practical error correction implementations. Typically, such faulty or noisy syndrome measurements are modeled as a binary measurement outcome flipped with some probability. However, the measured syndrome is in fact a discretized value of the continuous voltage or current values obtained in the physical implementation of the syndrome extraction. In this paper, we use this "soft" or analog information without the conventional discretization step to benefit the iterative decoders for decoding quantum low-density parity-check (QLDPC) codes. Syndrome-based iterative belief propagation (BP) decoders are modified to utilize the syndrome-soft information to successfully correct both data and syndrome errors simultaneously, without repeated measurements. We demonstrate the advantages of extracting the soft information from the syndrome in our improved decoders, not only in terms of comparison of thresholds and logical error rates for quasi-cyclic lifted-product QLDPC code families, but also for faster convergence of iterative decoders. In particular, the new BP decoder with noisy syndrome performs as good as the standard BP decoder under ideal syndrome.

97 MATHEMATICS AND COMPUTING↗

Design calculations for a xenon plasma x-ray shield to protect the NIF optical Thomson scattering diagnostic

An Optical Thomson Scattering (OTS) diagnostic is currently being developed for the National Ignition Facility (NIF) at Lawrence Livermore National Laboratory. This diagnostic is designed to make measurements of the hohlraum plasma parameters, such as the electron temperature and the density, during inertial confinement fusion (ICF) experiments. NIF ICF experiments present a very challenging environment for optical measurements; by their very nature, hohlraums produce intense soft x-ray emission, which can cause “blanking” (radiation induced opacity) of the radiation facing optical components. The soft x-ray fluence at the surface of the OTS blast shield, 60 cm from the hohlraum, is estimated to be ∼8 J cm{sup −2}. This is significantly above the expected threshold for the onset of “blanking” effects. A novel xenon plasma x-ray shield is proposed to protect the blast shield from x-rays and mitigate “blanking.” Estimates suggest that an areal density of 10{sup 19} cm{sup −2} Xe atoms will be sufficient to absorb 99.5% of the soft x-ray flux. Two potential designs for this shield are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Computation of the soft anomalous dimension matrix in coordinate space

We complete the coordinate space calculation of the three-parton correlation in the two-loop massive soft anomalous dimension matrix. The full answer agrees with the result found previously by a different approach. The coordinate space treatment of renormalized two-loop gluon exchange diagrams exhibits their color symmetries in a transparent fashion. We compare coordinate space calculations of the soft anomalous dimension matrix with massive and massless eikonal lines and examine its nonuniform limit at absolute threshold.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

RHESSI OBSERVATIONS OF THE PROPORTIONAL ACCELERATION OF RELATIVISTIC >0.3 MeV ELECTRONS AND >30 MeV PROTONS IN SOLAR FLARES

We analyze all RHESSI measurements from 2002 to 2005 (29 flare events) of the 2.223 MeV neutron-capture {gamma}-ray line and >0.3 MeV electron bremsstrahlung continuum emissions, produced by >30 MeV accelerated protons (depending on assumptions) and >0.3 MeV accelerated electrons, respectively. We find a close proportionality between the two emissions over >3 orders of magnitude in fluence, from the largest flares down to the limits of detectability. This implies that the processes in flares that accelerate electrons above 0.3 MeV and protons above 30 MeV are closely related, and that the relative acceleration of these two populations is roughly independent of flare size. We find an overall weak correlation between the 2.223 MeV fluence and the peak GOES 1-8 A soft X-ray (SXR) flux, but with a close proportionality for flares with 2.223 MeV fluence above a threshold of 50 ph cm{sup -2} (equivalent to {approx}2 x 10{sup 31} protons >30 MeV). Below this threshold the flares usually have large (M-class or higher) but generally uncorrelated excess SXR emission. Thus, above this threshold it appears that flares reach a maximum efficiency for >30 MeV proton and relativistic (>0.3 MeV) electron acceleration, with proportionate amounts of energy going to flare SXR thermal emission and to >50 keV electrons. Finally, we find that the electron-to-proton ratios-J{sub e} (0.5 MeV)/J{sub p} (10 MeV)-in these flares, obtained from the {gamma}-ray observations, are about 2 orders of magnitude larger than the ratios in gradual solar energetic particle (SEP) events, but are comparable with ratios in impulsive SEP events.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Dielectrophoretic bending of directly printed free-standing ultra-soft nanowires

Electrohydrodynamic printing has shown superior resolution compared to conventional ink-jet printing, but the use of electrically charged liquid commonly leads to unwanted repulsion effects posing a threshold to resolution capabilities. However, a recently demonstrated controlled dripping process of nanoscale, particle-laden droplets, could circumvent such resolution obstacles even on insulating substrates. Here, we show that so-printed free-standing nanostructures can be autonomously deformed, and mechanically characterized due to the presence of the electrified nozzle, or, after voltage termination, due to transient charge residuals on the structures themselves. Dielectrophoretic forces, arising between two subsequently printed nanopillars lead to their contactless bending and to the formation of out-of-plane arc structures arising from the connection of the pillar apexes. Once connected, the ultra-soft nanopillars are found to be tightly merged and could, for example, serve in electronics as out of plane nanobonds.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Constraints on the emission region of 3C 279 during strong flares in 2014 and 2015 through VHE γ -ray observations with H.E.S.S.

The flat spectrum radio quasar 3C 279 is known to exhibit pronounced variability in the high-energy (100 MeV < E < 100 GeV) γ-ray band, which is continuously monitored with Fermi-LAT. During two periods of high activity in April 2014 and June 2015 target-of-opportunity observations were undertaken with the High Energy Stereoscopic System (H.E.S.S.) in the very-high-energy (VHE, E> 100 GeV) γ-ray domain. While the observation in 2014 provides an upper limit, the observation in 2015 results in a signal with 8.7σ significance above an energy threshold of 66 GeV. No VHE variability was detected during the 2015 observations. The VHE photon spectrum is soft and described by a power-law index of 4.2 ± 0.3. The H.E.S.S. data along with a detailed and contemporaneous multiwavelength data set provide constraints on the physical parameters of the emission region. The minimum distance of the emission region from the central black hole was estimated using two plausible geometries of the broad-line region and three potential intrinsic spectra. The emission region is confidently placed at r≳1.7 × 10 17 cm from the black hole, that is beyond the assumed distance of the broad-line region. Time-dependent leptonic and lepto-hadronic one-zone models were used to describe the evolution of the 2015 flare. In conclusion, neither model can fully reproduce the observations, despite testing various parameter sets. Furthermore, the H.E.S.S. data were used to derive constraints on Lorentz invariance violation given the large redshift of 3C 279.

79 ASTRONOMY AND ASTROPHYSICS↗

Material separation in x-ray CT with energy resolved photon-counting detectors

Purpose: The objective of the study was to demonstrate that, in x-ray computed tomography (CT), more than two types of materials can be effectively separated with the use of an energy resolved photon-counting detector and classification methodology. Specifically, this applies to the case when contrast agents that contain K-absorption edges in the energy range of interest are present in the object. This separation is enabled via the use of recently developed energy resolved photon-counting detectors with multiple thresholds, which allow simultaneous measurements of the x-ray attenuation at multiple energies. Methods: To demonstrate this capability, we performed simulations and physical experiments using a six-threshold energy resolved photon-counting detector. We imaged mouse-sized cylindrical phantoms filled with several soft-tissue-like and bone-like materials and with iodine-based and gadolinium-based contrast agents. The linear attenuation coefficients were reconstructed for each material in each energy window and were visualized as scatter plots between pairs of energy windows. For comparison, a dual-kVp CT was also simulated using the same phantom materials. In this case, the linear attenuation coefficients at the lower kVp were plotted against those at the higher kVp. Results: In both the simulations and the physical experiments, the contrast agents were easily separable from other soft-tissue-like and bone-like materials, thanks to the availability of the attenuation coefficient measurements at more than two energies provided by the energy resolved photon-counting detector. In the simulations, the amount of separation was observed to be proportional to the concentration of the contrast agents; however, this was not observed in the physical experiments due to limitations of the real detector system. We used the angle between pairs of attenuation coefficient vectors in either the 5-D space (for non-contrast-agent materials using energy resolved photon-counting acquisition) or a 2-D space (for contrast agents using energy resolved photon-counting acquisition and all materials using dual-kVp acquisition) as a measure of the degree of separation. Compared to dual-kVp techniques, an energy resolved detector provided a larger separation and the ability to separate different target materials using measurements acquired in different energy window pairs with a single x-ray exposure. Conclusions: We concluded that x-ray CT with an energy resolved photon-counting detector with more than two energy windows allows the separation of more than two types of materials, e.g., soft-tissue-like, bone-like, and one or more materials with K-edges in the energy range of interest. Separating material types using energy resolved photon-counting detectors has a number of advantages over dual-kVp CT in terms of the degree of separation and the number of materials that can be separated simultaneously.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Single-pulse resonant magnetic scattering using a soft x-ray free-electron laser

We report on single-pulse resonant magnetic scattering experiments using soft x-ray pulses generated by the free-electron laser FLASH at DESY. We could record a magnetic diffraction pattern from a Co/Pt multilayer sample at the Co M{sub 2,3} edge with a single 30-fs-long FEL pulse. The analysis of the magnetic small-angle scattering signal for subsequent pulses indicates a threshold energy density below which there is no indication that the magnetic properties of the sample might be altered.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

THE CHANDRA DEEP FIELD-SOUTH SURVEY: 4 Ms SOURCE CATALOGS

We present source catalogs for the 4 Ms Chandra Deep Field-South (CDF-S), which is the deepest Chandra survey to date and covers an area of 464.5 arcmin{sup 2}. We provide a main Chandra source catalog, which contains 740 X-ray sources that are detected with WAVDETECT at a false-positive probability threshold of 10{sup -5} in at least one of three X-ray bands (0.5-8 keV, full band; 0.5-2 keV, soft band; and 2-8 keV, hard band) and also satisfy a binomial-probability source-selection criterion of P < 0.004 (i.e., the probability of sources not being real is less than 0.004); this approach is designed to maximize the number of reliable sources detected. A total of 300 main-catalog sources are new compared to the previous 2 Ms CDF-S main-catalog sources. We determine X-ray source positions using centroid and matched-filter techniques and obtain a median positional uncertainty of {approx}0.''42. We also provide a supplementary catalog, which consists of 36 sources that are detected with WAVDETECT at a false-positive probability threshold of 10{sup -5}, satisfy the condition of 0.004 < P < 0.1, and have an optical counterpart with R < 24. Multiwavelength identifications, basic optical/infrared/radio photometry, and spectroscopic/photometric redshifts are provided for the X-ray sources in the main and supplementary catalogs. Seven hundred sixteen ({approx}97%) of the 740 main-catalog sources have multiwavelength counterparts, with 673 ({approx}94% of 716) having either spectroscopic or photometric redshifts. The 740 main-catalog sources span broad ranges of full-band flux and 0.5-8 keV luminosity; the 300 new main-catalog sources span similar ranges although they tend to be systematically lower. Basic analyses of the X-ray and multiwavelength properties of the sources indicate that >75% of the main-catalog sources are active galactic nuclei (AGNs); of the 300 new main-catalog sources, about 35% are likely normal and starburst galaxies, reflecting the rise of normal and starburst galaxies at the very faint flux levels uniquely accessible to the 4 Ms CDF-S. Near the center of the 4 Ms CDF-S (i.e., within an off-axis angle of 3'), the observed AGN and galaxy source densities have reached 9800{sup +1300}{sub -1100} deg{sup -2} and 6900{sup +1100}{sub -900} deg{sup -2}, respectively. Simulations show that our main catalog is highly reliable and is reasonably complete. The mean backgrounds (corrected for vignetting and exposure-time variations) are 0.063 and 0.178 counts Ms{sup -1} pixel{sup -1} (for a pixel size of 0.''492) for the soft and hard bands, respectively; the majority of the pixels have zero background counts. The 4 Ms CDF-S reaches on-axis flux limits of {approx}3.2 x 10{sup -17}, 9.1 x 10{sup -18}, and 5.5 x 10{sup -17} erg cm{sup -2} s{sup -1} for the full, soft, and hard bands, respectively. An increase in the CDF-S exposure time by a factor of {approx}2-2.5 would provide further significant gains and probe key unexplored discovery space.

79 ASTRONOMY AND ASTROPHYSICS↗

Three-loop soft function for energetic electroweak boson production at hadron colliders

We calculate the three-loop soft function for the production of an electroweak boson (Higgs, γ , W ± , Z ) with large transverse momentum at a hadron collider. It is the first time a soft function for a three-parton process is computed at next-to-next-to-next-to-leading order (N 3 LO). As a technical novelty, we perform the calculation in terms of forward-scattering-type loop diagrams rather than evaluating phase space integrals. Our three-loop result contains color-tripole contributions and explicitly confirms predictions on the universal infrared structure of QCD scattering amplitudes with three massless parton legs. The soft function is a central ingredient in the factorized cross section for electroweak boson production near the kinematic endpoint (threshold), where the invariant mass of the recoiling hadronic radiation is small compared to its transverse momentum. Our result is required for predictions of the near-threshold cross sections at N 3 LO and for the resummation of threshold logarithms at primed next-to-next-to-next-to-leading logarithmic (N 3 LL') accuracy.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗