Search NASA⌕ Search

SEARCH · Search NASA

Results for “Solar Band”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Comparison of MODIS Solar Diffuser Stability Monitor Calibration Results for Different Operational Configurations

The MODIS instruments on the Terra and Aqua spacecraft use a sunlit solar diffuser (SD), with an optional SD attenuation screen (SDS), to calibrate the reflective solar bands. A solar diffuser stability monitor (SDSM) is used to track the SD reflectance degradation on orbit, by taking a ratio of the detector response when viewing the SD compared to the response when viewing the sun. The MODIS SDSMs have been operated both with and without the SDS in place. The SDSMs have also been operated in both a fixed and an alternating mode. In the alternating mode, the SDSM detectors view the SD, sun, and a dark background in an alternating pattern with the view changing on every MODIS scan within a single orbit. In the fixed mode, the SDSM detectors are fixed on the sun view for one orbit, and then are fixed on the SD view for the following orbit. This paper reviews the history of the SDSM operational configurations used throughout the MODIS missions and discusses the differences in the SD degradation results, which may be due to differences in sun-satellite geometry, SD signal level, and stray light effects. We highlight Aqua SDSM results from two recent dates in October 2017 and July 2019, where both the fixed and alternating mode calibrations were run on the same day, providing clear examples of the calibration differences. Additionally, we show how mixing the results from calibrations done with and without the SDS for Aqua MODIS can provide more stable results.

Twedt, Kevin A.↗

Degradation of MODIS Optics During the First Year of On-Orbit Operation

The MODIS (Moderate Resolution Imaging Spectroradiometer) sensor on the NASA EOS (Earth Observing System) Terra spacecraft has completed more than one year of on-orbit operation since the instrument opened its Nadir door for the scene data collection on 24 February 2000. Its 20 reflective solar bands, from VIS (visible) to SWIR (shortwavelength infrared) (0.41 to 2.1 micron), are calibrated on-orbit by a solar diffuser (SD) and a solar diffuser stability monitor (SDSM). Degradation in the reflective solar bands has been observed in the reflectance of the on board solar diffuser and for the MODIS optics. Variations in degradation of up to 3% are evident between the two sides of the MODIS scan mirror. Degradation of the SD is tracked with the solar diffuser stability monitor, and degradation of the entire MODIS system is tracked by SD observations, adjusted for SD changes. Overall degradation at the shortest wavelengths (near 400 nm) are up to 3% for SD, and in excess of 10% for the MODIS system. Degradation of the SD and full MODIS system for the sensor's reflective solar bands will be described in this report.

Guenther, B.↗

Theoretical optimization and parametric study of n-on-p Al/x/Ga/1-x/As-GaAs graded band-gap solar cell

A comprehensive theoretical model of the graded band-gap Al(x)Ga(1-x)As-GaAs solar cell is used to optimize the n-on-p cell. The model includes power losses due to surface, bulk, and junction minority-carrier recombination, series resistance, and photon reflection from an SiO antireflection coating of optimum thickness. The optimized cell has a junction depth/graded band-gap layer thickness of 1.0 micron, respective donor and acceptor concentrations of 4 x 10 to the 17th power and 2 x 10 to the 17th power per cu cm, and a surface AlAs mode fraction of x = 0.35. The optimized graded band-gap cell has an air-mass-zero efficiency of 17.7% (not corrected for a 13% front surface contact area) and is shown to be less sensitive than a similar n-on-p GaAs cell to material degradation in the form of decreased minority-carrier diffusion lengths and increased surface-recombination velocity

Hutchby, J. A.↗

Theoretical analysis of Al/x/Ga/1-x/As-GaAs graded band-gap solar cell

A practical theoretical analysis of an n/p graded band-gap Al(x)Ga(1-x)As-GaAs solar cell indicates that the presence of a built-in electric field acting on holes in the surface layer increases the hole collection efficiency of a nearly optimum cell to a maximum of 97.8%. The electric field is created by the band-gap gradient and serves to reduce the surface hole recombination by 97% and reduce the bulk hole recombination by 80%, compared to a similar GaAs cell. These reduced losses increase cell response substantially for wavelengths less than 0.59 micron and yield a maximum air-mass-zero efficiency of 17.7% (not corrected for a 13% front-surface contact). The model includes an optimized antireflection coating, series resistance, and junction-recombination current.

Hutchby, J. A.↗

Deconvolution of SNPP VIIRS Solar Diffuser Bidirectional Reflectance Distribution Function On-orbit Change Factor

The Earth-observing Visible Infrared Imaging Radiometer Suite (VIIRS) on the Suomi National Polar-orbiting Partnership satellite regularly calibrates its reflective solar bands (RSBs), primarily through observing an onboard sunlit solar diffuser (SD). The on-orbit change of the value of the SD bidirectional reflectance distribution function (BRDF) is quantified by a numerical factor, called the H-factor, and is determined by the onboard SD stability monitor (SDSM). Because the spectral response function of an SDSM detector spreads in wavelength, the directly measured H-factor is the true H-factor convolved with the spectral response function. To find the true H-factor, we use the traditional direct method and an innovative iterative approach to separately deconvolve the measured H-factor. Our iterative approach relies on two properties of the SDSM detector spectral response function: the central peak width is narrow enough so that the H-factor does not change much over the peak width, and the dominance of the spectral response function’s integral with respect to the wavelength over the width. The iterative approach is more accurate, of a smaller noise impact, much more flexible in terms of interpolation and extrapolation of function values, and faster. We have used deconvolved H-factors to calibrate the NASA SNPP VIIRS RSB Collections 1 and 2 Level-1B products.

SNPP VIIRS↗

Positional Dependence of SNPP VIIRS Solar Diffuser BRDF Change Factor: An Empirical Approach

The Earth-observing Visible Infrared Imaging Radiometer Suite (VIIRS) on the Suomi National Polar-orbiting Partnership satellite regularly performs on-orbit radiometric calibration of its reflective solar bands (RSBs), primarily through observations of an onboard sunlit solar diffuser (SD). The on-orbit change of the SD bidirectional reflectance distribution function (BRDF) value, quantified by a numerical factor called the H-factor, is determined by the onboard SD stability monitor. Our previous study showed that the H-factor is solar angle and view direction dependent. In this study, we determine the dependence of the H-factor on the detector SD view footprint location. We fit an empirical model to the NASA Collection 1 SNPP VIIRS Level 1B (L1B) spectral reflectance difference across the detectors in an RSB over uniform Earth scenes of the Libya 4 desert and deep convective clouds. We apply the model predicted SD positional dependent H-factor to calibrate the RSBs. Under this new calibration scheme, the original unreal striping is removed from the homogeneous Libya 4 desert and the deep convective cloud images, as well as the original unreal striping from the Dunhuang desert image. The SD positional dependent H-factor has been used to calculate the SNPP VIIRS RSB radiometric correction factor for the NASA Collection 2.0 SNPP VIIRS L1B products.

SNPP VIIRS↗

Status of Aqua MODIS On-orbit Calibration and Characterization

The MODIS Flight Model 1 (FM1) has been in operation for more than two years since its launch onboard the NASA's Earth Observing System (EOS) Aqua spacecraft on May 4, 2002. The MODIS has 36 spectral bands: 20 reflective solar bands (RSB) with center wavelengths from 0.41 to 2.2 micron and 16 thermal emissive bands (TEB) from 3.7 to 14.5 micron. It provides the science community observations (data products) of the Earth's land, oceans, and atmosphere for a board range of applications. Its primary on-orbit calibration and characterization activities are performed using a solar diffuser (SD) and a solar diffuser stability monitor (SDSM) system for the RSB and a blackbody for the TEB. Another on-board calibrator (OBC) known as the spectro-radiometric calibration assembly (SRCA) is used for the instrument's spatial (TEB and RSB) and spectral (RSB only) characterization. We present in this paper the status of Aqua MODIS calibration and characterization during its first two years of on-orbit operation. Discussions will be focused on the calibration activities executed on-orbit in order to maintain and enhance the instrument's performance and the quality of its Level 1B (L1B) data products. We also provide comparisons between Aqua MODIS and Terra MODIS (launched in December, 1999), including their similarity and difference in response trending and optics degradation. Existing data and results show that Aqua MODIS bands 8 (0.412 micron) and 9 (0.443 micron) have much smaller degradation than Terra MODIS bands 8 and 9. The most noticeable feature shown in the RSB trending is that the mirror side differences in Aqua MODIS are extremely small and stable (<0.1%) while the Terra MODIS RSB trending has shown significant mirror side difference and wavelength dependent degradation. The overall stability of the Aqua MODIS TEB is also better than that of the Terra MODIS during their first two years of on-orbit operation.

Aqua↗

Summary of Terra and Aqua MODIS On-orbit Calibration and Characterization Results

The Moderate Resolution Imaging Spectroradiometer (MODIS) onboard NASA's EOS Terra spacecraft has been in operation for more than seven years since its launch in December 1999 and the MODIS onboard Aqua spacecraft has been in operation for more than 4.5 years since its launch in May 2002. Compared to its heritage sensors, such as AVHRR, CZCS, SeaWiFS, HIRS, and Landsat TM, the MODIS instrument was developed with improved spectral and spatial resolutions, and temporal scale or global coverage frequency. The two MODIS instruments are nearly identical with each collecting data in 36 spectral bands: 20 reflective solar bands (RSB) with center wavelengths from 0.41 to 2.2jm and 16 thermal emissive bands (TEB) from 3.7 to 4.4 microns. MODIS makes the Earth view observations with a scan angle range of +/-55 degree relative to instrument nadir and at three nadir spatial resolutions: 0.25km for bands 1-2.05km for bands 3-7, and 1km for bands 8-36, thus enabling complete global coverage of the Earth in less than 2 days. Both Terra and Aqua MODIS observations have been routinely used to generate a broad range of science data products that are widely distributed and extensively applied for the studies of the Earth's land, oceans, and atmosphere and for the monitoring of climate and environmental changes. It is obvious that the MODIS science data product quality strongly relies on sensor on-orbit performance and its capability of continuously tracking sensor response changes over time. Because of this, each MODIS was built with a comprehensive set of on-board calibrators (OBC) that include a solar diffuser (SD) for the RSB calibration, a blackbody (BB) for the TEB calibration, and a spectro-radiometric calibration assembly (SRCA) for the spatial (RSB and TEB) and spectral (RSB only) characterization. Most importantly, extensive and dedicated sensor calibration and characterization efforts have been constantly made by the MODIS Characterization Support Team (MCST) at NASA/GSFC. In this presentation, we will provide an overview of MODIS sensor operations since 1aunh and the onorbit calibration and characterization methodologies with emphasis on the differences between Terra and Aqua MODIS characteristics. We will summarize both Terra and Aqua MODIS onorbit calibration and characterization results, including their RSB and TEB detector noise characterization, the sensor response changes, and the corrections to the optics degradation. In addition to radiometric calibration performance, we will illustrate both sensors' spectral and spatial characterization results in terms of their band-to-band registrations and spectral band center wavelength shifts.

Xiong, X.↗

MODIS Radiometric Calibration and Uncertainty Assessment

Since launch, Terra and Aqua MODIS have collected more than II and 9 years of datasets for comprehensive studies of the Earth's land, ocean, and atmospheric properties. MODIS observations are made in 36 spectral bands: 20 reflective solar bands (RSB) and 16 thermal emissive bands (TEB). Compared to its heritage sensors, MODIS was developed with very stringent calibration and uncertainty requirements. As a result, MODIS was designed and built with a set of state of the art on-board calibrators (OBC), which allow key sensor performance parameters and on-orbit calibration coefficients to be monitored and updated if necessary. In terms of its calibration traceability, MODIS RSB calibration is reflectance based using an on-board solar diffuser (SD) and the TEB calibration is radiance based using an on-board blackbody (BB). In addition to on-orbit calibration coefficients derived from its OBC, calibration parameters determined from sensor pre-launch calibration and characterization are used in both the RSB and TEB calibration and retrieval algorithms. This paper provides a brief description of MODIS calibration methodologies and discusses details of its on-orbit calibration uncertainties. It assesses uncertainty contributions from individual components and differences between Terra and Aqua MODIS due to their design characteristics and on-orbit periormance. Also discussed in this paper is the use of MODIS LIB uncertainty index CUI) product.

Xiong, Xiaoxiong↗

Aqua MODIS Thermal Emissive Band On-Orbit Calibration, Characterization, and Performance

The NASA's Earth Observing System Aqua Moderate Resolution Imaging Spectroradiometer (MODIS) has continued to operate with satisfactory performance since its launch in May 2002, exceeding its nominal six-year design lifetime. Its continuous Earth observations have been used to generate many science data products for studies of the Earth's, system. MODIS has 36 spectral bands; 20 reflective solar bands and 16 thermal emissive bands (TEBs). All TEB observations are made at 1-km nadir spatial resolution with spectral wavelengths from 3.7 to 14.4 pm. Primary applications of MODIS TEB 'include surface, cloud, and atmospheric temperatures, water vapor, and cloud top altitude. MODIS TEB on-orbit calibration uses a quadratic algorithm with its calibration coefficients derived using an onboard blackbody (BB). This paper will present Aqua MODIS TEB on-orbit calibration, characterization, and performance over its six-year mission. Examples of instrument thermal behavior, BB temperature stability, detector short-term stability, and changes in long-term response (or system gain) will be presented. Comparisons will also be made with Terra MODIS, launched in December 1999. On-orbit results show that Aqua MODIS and its focal plane temperatures have behaved normally. BB temperature has remained extremely stable with typical scan -to-scan variations of less than +/-0.15 mK. Most TEB detectors continue to exceed their specified signal-to-noise ratio requirements, exhibiting excellent short-term stability and calibration accuracy. Excluding a few noisy detectors, either identified prelaunch or occurring postlaunch, on-orbit changes in TEB responses have been less than 0.5% on an annual basis. By comparison; the overall Aqua TEB performance has been better than that of Terra MODIS,

Xiong, Xiaoxiong↗

Aqua MODIS 8-Year On-Orbit Operation and Calibration

Launched in May 2002, the NASA EOS Aqua MODIS has successfully operated for more than 8 years. Observations from Aqua MODIS and its predecessor, Terra MODIS, have generated an unprecedented amount of data products and made significant contributions to studies of changes in the Earth s system of land, oceans, and atmosphere. MODIS collects data in 36 spectral bands: 20 reflective solar bands (RSB) and 16 thermal emissive bands (TEB). It has a set of on-board calibrators (OBC), providing sensor on-orbit radiometric, spectral, and spatial calibration and characterization. This paper briefly summarizes Aqua MODIS on-orbit operation and calibration activities and illustrates instrument on-orbit performance from launch to present. Discussions are focused on OBC functions and changes in detector radiometric gains, spectral responses, and spatial registrations. With ongoing calibration effort, Aqua MODIS will continue serving the science community with high quality data products

Xiong, Xiaoxiong↗

Improvements of VIIRS and MODIS Solar Diffuser and Lunar Calibration

Both VIIRS and MODIS instruments use solar diffuser (SD) and lunar observations to calibrate their reflective solar bands (RSB). A solar diffuser stability monitor (SDSM) is used to track the SD on-orbit degradation. On-orbit observations have shown similar wavelength-dependent SD degradation (larger at shorter VIS wavelengths) and SDSM detector response degradation (larger at longer NIR wavelengths) for both VIIRS and MODIS instruments. In general, the MODIS scan mirror has experienced more degradation in the VIS spectral region whereas the VIIRS rotating telescope assembly (RTA) mirrors have seen more degradation in the NIR and SWIR spectral region. Because of this wavelength dependent mirror degradation, the sensor's relative spectral response (RSR) needs to be modulated. Due to differences between the solar and lunar spectral irradiance, the modulated RSR could have different effects on the SD and lunar calibration. In this paper, we identify various factors that should be considered for the improvements of VIIRS and MODIS solar and lunar calibration and examine their potential impact. Specifically, we will characterize and assess the calibration impact due to SD and SDSM attenuation screen transmission (uncertainty), SD BRF uncertainty and onorbit degradation, SDSM detector response degradation, and modulated RSR resulting from the sensor's optics degradation. Also illustrated and discussed in this paper are the calibration strategies implemented in the VIIRS and MODIS SD and lunar calibrations and efforts that could be made for future improvements.

VIIRS↗

On Orbit Measurement of Response vs. Scan Angle for the Infrared Bands on TRMM/VIRS

The Visible and Infrared Scanner on the Tropical Rainfall Measuring Mission (TRMM/VIRS) is a whiskbroom imaging radiometer with two reflected solar bands and three emissive infrared bands. All five detectors are on a single cooled focal plane. This configuration necessitated the use of a paddlewheel scan mirror to avoid the effects of focal plane rotation that arise when using a scan mirror that is inclined to its axis of rotation. System radiometric requirements led to the need for protected silver as the mirror surface. Unfortunately, the SiO(x) coatings currently used to protect silver from oxidation introduce a change in reflectance with angle of incidence (AOI). This AOI dependence results in a modulation of system level response with scan angle. Measurement of system response vs. scan angle (RVS) was not difficult for the VIRS reflected solar bands, but attaining the required accuracy for the IR bands in the laboratory was not possible without a large vacuum chamber and a considerable amount of custom designed testing apparatus. Therefore, the decision was made to conduct the measurement on-orbit. On three separate occasions, the TRMM spacecraft was rotated about its pitch axis and, after the nadir view passed over the Earth's limb, the VIRS performed several thousand scans while viewing deep space. The resulting data has been analyzed and the RVS curves generated for the three IR bands are being used in the VIRS radiometric calibration algorithm. This, to our knowledge, the first time this measurement has been made on-orbit. Similar measurements are planned for the EOS-AM and EOS-PM MODIS sensors and are being considered for several systems under development. The VIRS on-orbit results will be compared to VIRS and MODIS system level laboratory measurements, MODIS scan mirror witness sample measurements and modeled data.

Barnes, William L.↗

Pre-Launch Algorithm and Data Format for the Level 1 Calibration Products for the EOS AM-1 Moderate Resolution Imaging Spectroradiometer (MODIS)

The Moderate Resolution Imaging Spectroradiometer (MODIS) radiometric calibration product is described for the thermal emissive and the reflective solar bands. Specific sensor design characteristics are identified to assist in understanding how the calibration algorithm software product is designed. The reflected solar band software products of radiance and reflectance factor both are described. The product file format is summarized and the MODIS Characterization Support Team (MCST) Homepage location for the current file format is provided.

Guenther, Bruce W.↗

Above-Cloud Precipitable Water Retrievals using the MODIS 0.94 micron Band with Applications for Multi-Layer Cloud Detection

In order to perform satellite retrievals of cloud properties, it is important to account for the effect of the above-cloud atmosphere on the observations. The solar bands used in the operational MODIS Terra and Aqua cloud optical and microphysical algorithms (visible, NIR, and SWIR spectral windows) are primarily affected by water vapor, and to a lesser extent by well-mixed gases. For water vapor, the above-cloud column amount, or precipitable water, provides adequate information for an atmospheric correction; details of the vertical vapor distribution are not typically necessary for the level of correction required. Cloud-top pressure has a secondary effect due to pressure broadening influences. For well- mixed gases, cloud-top pressure is also required for estimates of above-cloud abundances. We present a method for obtaining above-cloud precipitable water over dark Ocean surfaces using the MODIS 0.94 pm vapor absorption band. The retrieval includes an iterative procedure for establishing cloud-top temperature and pressure, and is useful for both single layer water and ice clouds. Knowledge of cloud thermodynamic phase is fundamental in retrieving cloud optical and microphysical properties. However, in cases of optically thin cirrus overlapping lower water clouds, the concept of a single unique phase is ill- defined and depends, at least, on the spectral region of interest. We will present a method for multi-layer and multi-phase cloud detection which uses above-cloud precipitable water retrievals along with several existing MODIS operational cloud products (cloud-top pressure derived from a C02 slicing algorithm, IR and SWIR phase retrievals). Results are catagorized by whether the radiative signature in the MODIS solar bands is primarily that of a water cloud with ice cloud contamination, or visa-versa. Examples in polar and mid-latitude regions will be shown.

Platnick, S.↗

SNPP VIIRS RSB on-orbit radiometric calibration algorithms Version 2.0 and the performances. Part II: The performances

In Part I (Lei et. al, submitted to J. of Appl. Rem. Sens.),we gave detailed reviews of the algorithms Version 2.0 used for the on-orbit radiometric calibration of the reflective solar bands (RSBs) of the first Visible Infrared Imaging Radiometer Suite instrument. These algorithms improve the accuracy of the measured on-orbit change factor of the solar diffuser bidirectional reflectance distribution function, the H-factor, and reveal that the H-factor is angle dependent. With the help of lunar observations and the improved H-factor, the algorithms give more accurate values for the RSB detector on-orbit F-factor changes (F-factor is a correction factor to the initially retrieved scene spectral radiance). In this paper we review the RSB radiometric calibration performances. We show the H-factor temporal trend, the estimated uncertainty of the retrieved H-factor, and the F-factor temporal trend. Additionally we show the detector signal-to-noise ratio (SNR), the estimated uncertainty of the top-of-the-atmosphere solar spectral reflectance, the reflectance temporal trend for the Libya 4 desert, and the differences in the reflectances among the SNPP and the NOAA-20 VIIRS, and the Aqua MODIS. Our results show that although the SNRs trend downwards, they exceed the requirements by large margins. The reflectances from the Libya 4 desert show that the SNPP VIIRS’ reflectance is higher than those of the Aqua MODIS and the NOAA-20 VIIRS.

on-orbit calibration↗

Characterization of MODIS VIS/NIR Spectral Band Detector-to-Detector Difference

MODIS has 36 spectral bands with wavelengths in the visible (VIS), near-infrared (NIR), shortwave infrared (SWTR), mid-wave infrared (MWIR), and long-wave infrared (LWIR). It makes observations at three nadir spatial resolutions: 0,25km for bands 1-2 with 40 detectors per band, 0.5km for bands 3-7 with 20 detectors per band, and 1km for bands 8-36 with 10 detectors per band. The VIS, NIR, and S\VIR spectral bands are the reflective solar bands (RSB), which are calibrated on-orbit by a solar diffuser (SD). In addition, MODIS lunar observations are used to track the RSB calibration stability. In this study, we examine detector-to-detector calibration difference for the VIStNIR spectral bands using the SD and lunar observations. The results will be compared with an independent analysis with additional information, such as polarization correction, derived from standard ocean color data products. The current MODIS RSB calibration approach only carries a band-averaged RVS (response versus scan angle) correction. The results from this study suggest that a detector-based RVS correction should be used to improve the L1B data quality, especially for several VIS bands in Terra MODIS due to large changes of the scan mirror's optical properties in recent years.

Xiong, X.↗

Analysis of the on-orbit Response-Versus-Scan-angle for the MODIS SWIR Bands Derived from Lunar Observations

The Moderate Resolution Imaging Spectroradiometer (MODIS) on board the Terra and Aqua platforms is a multi-spectral, whiskbroom scanning radiometer with 36 spectral bands covering wavelengths from 0:4 - 14:2 μm. Among these bands, the 20 reflective solar bands (RSB, 0:4 - 2:1 μm) use an on-board solar difuser (SD) and SD stability monitor (SDSM) to track the detector gain changes on orbit. In addition to this, lunar and Earth-view (EV) observations are used in order to characterize the scan-mirror response versus scan angle (RVS), which improves the Earth-view retrieval over the full width of each scan. For the short-wave infrared bands (SWIR, 1:2 - 2:1 μm), the prelaunch RVS has been used for both Aqua and Terra MODIS throughout each mission. While these bands are not expected to have a significant change in the RVS on-orbit, issues such as electronic crosstalk and an out-of-band optical leak have prevented the use of the Moon for deriving the on-orbit RVS for validation. However, recent improvements to the MODIS lunar calibration for the SWIR bands allow us to mitigate the electronic crosstalk impact and derive the RVS for the SWIR bands. In this work, we will assess the impact of this newly derived RVS on the EV data compared to MODIS Collection 6.1. By comparing to EV data obtained from pseudo-invariant calibration sites at different angles-of-incidence on the scan mirror, we can assess the effectiveness of the newly derived RVS from the Moon. We find that while the change in the RVS on-orbit for the SWIR bands is relatively small, applying a correction to the RVS based on the Moon and SD data can provide an improvement for some bands.

MODIS↗