An Evaluation of Possible Next-Generation High Temperature Molten-Salt Power Towers

Since completion of the Solar Two molten-salt power tower demonstration in 1999, the solar industry has been developing initial commercial-scale projects that are 3 to 14 times larger. Like Solar Two, these initial plants will power subcritical steam-Rankine cycles using molten salt with a temperature of 565 °C. The main question explored in this study is whether there is significant economic benefit to develop future molten-salt plants that operate at a higher receiver outlet temperature. Higher temperatures would allow the use of supercritical steam cycles that achieve an improved efficiency relative to today's subcritical cycle (~50% versus ~42%). The levelized cost of electricity (LCOE) of a 565 °C subcritical baseline plant was compared with possible future-generation plants that operate at 600 or 650 °C. The analysis suggests that ~8% reduction in LCOE can be expected by raising salt temperature to 650 °C. However, most of that benefit can be achieved by raising the temperature to only 600 °C. Several other important insights regarding possible next-generation power towers were also drawn: (1) the evaluation of receiver-tube materials that are capable of higher fluxes and temperatures, (2) suggested plant reliability improvements based on a detailed evaluation of the Solar Two experience, and (3) a thorough evaluation of analysis uncertainties.

14 SOLAR ENERGY↗

Atmospheric Transmittance Model Validation for CSP Tower Plants

In yield analysis and plant design of concentrated solar power (CSP) tower plants, increased uncertainties are caused by the mostly unknown solar attenuation between the concentrating heliostat field and the receiver on top of the tower. This attenuation is caused mainly by aerosol particles and water vapor. Various on-site measurement methods of atmospheric extinction in solar tower plants have been developed during recent years, but during resource assessment for distinct tower plant projects in-situ measurement data sets are typically not available. To overcome this lack of information, a transmittance model (TM) has been previously developed and enhanced by the authors to derive the atmospheric transmittance between a heliostat and receiver on the basis of common direct normal irradiance (DNI), temperature, relative humidity and barometric pressure measurements. Previously the model was only tested at one site. In this manuscript, the enhanced TM is validated for three sites (CIEMAT’s Plataforma Solar de Almería (PSA), Spain, Missour, Morocco (MIS) and Zagora, Morocco (ZAG)). As the strongest assumption in the TM is the vertical aerosol particle profile, three different approaches to describe the vertical profile are tested in the TM. One approach assumes a homogeneous aerosol profile up to 1 kilometer above ground, the second approach is based on LIVAS profiles obtained from Lidar measurements and the third approach uses boundary layer height (BLH) data of the European Centre for Medium-Range Weather Forecasts (ECMWF). The derived broadband transmittance for a slant range of 1 km (T 1$km$ ) time series is compared with a reference data set of on-site absorption- and broadband corrected T 1$km$ derived from meteorological optical range (MOR) measurements for the temporal period between January 2015 and November 2017. The absolute mean bias error (MBE) for the TM’s T 1$km$ using the three different aerosol profiles lies below 5% except for ZAG and one profile assumption. The MBE is close to 0 for PSA and MIS assuming a homogeneous extinction coefficient up to 1 km above ground. The root mean square error (RMSE) is around 5–6% for PSA and ZAG and around 7–8% for MIS. The TM performs better during summer months, during which more data points have been evaluated. This validation proves the applicability of the transmittance model for resource assessment at various sites. It enables the identification of a clear site with high T 1$km$ with a high accuracy and provides an estimation of the T 1$km$ for hazy sites. Thus it facilitates the decision if on-site extinction measurements are necessary. The model can be used to improve the accuracy of yield analysis of tower plants and allows the site adapted design.

14 SOLAR ENERGY↗

Leveraging Energy Storage in a Solar-Tower and Combined Cycle Hybrid Power Plant

A method is presented to enhance solar penetration of a hybrid solar-combined cycle power plant integrated with a packed-bed thermal energy storage system. The hybrid plant is modeled using Simulink and employs systems-level automation. Feedback control regulates net power, collector temperature, and turbine firing temperature. A base-case plant is presented, and plant design is systematically modified to improve solar energy utilization. A novel recycling configuration enables robust control of collector temperature and net power during times of high solar activity. Recycling allows for improved solar energy utilization and a yearly solar fraction over 30%, while maintaining power control. During significant solar activity, excessive collector temperature and power setpoint mismatch are still observed with the proposed recycling configuration. A storage bypass is integrated with recycling, to lower storage charging rate. This operation results in diverting only a fraction of air flow to storage, which lowers the storage charging rate and improves solar energy utilization. Recycling with a storage bypass can handle larger solar inputs and a solar fraction over 70% occurs when following a drastic peaking power load. The novel plant configuration is estimated to reduce levelized cost of the plant by over 4% compared to the base-case plant.

14 SOLAR ENERGY↗

Advanced Electric Propulsion for Space Solar Power Satellites

The sun tower concept of collecting solar energy in space and beaming it down for commercial use will require very affordable in-space as well as earth-to-orbit transportation. Advanced electric propulsion using a 200 kW power and propulsion system added to the sun tower nodes can provide a factor of two reduction in the required number of launch vehicles when compared to in-space cryogenic chemical systems. In addition, the total time required to launch and deliver the complete sun tower system is of the same order of magnitude using high power electric propulsion or cryogenic chemical propulsion: around one year. Advanced electric propulsion can also be used to minimize the stationkeeping propulsion system mass for this unique space platform. 50 to 100 kW class Hall, ion, magnetoplasmadynamic, and pulsed inductive thrusters are compared. High power Hall thruster technology provides the best mix of launches saved and shortest ground to Geosynchronous Earth Orbital Environment (GEO) delivery time of all the systems, including chemical. More detailed studies comparing launch vehicle costs, transfer operations costs, and propulsion system costs and complexities must be made to down-select a technology. The concept of adding electric propulsion to the sun tower nodes was compared to a concept using re-useable electric propulsion tugs for Low Earth Orbital Environment (LEO) to GEO transfer. While the tug concept would reduce the total number of required propulsion systems, more launchers and notably longer LEO to GEO and complete sun tower ground to GEO times would be required. The tugs would also need more complex, longer life propulsion systems and the ability to dock with sun tower nodes.

Oleson, Steve↗

Design of a novel carbon/carbon composite microvascular solar receiver

Solar thermal power tower systems are the primary technology being proposed for solar electricity from thermal energy. Operational limits on these towers are often driven by mechanical properties under significant thermal loads, particularly at the receiver where incoming flux is converted to thermal energy. While the solar receiver’s efficiency is largely driven by its optical properties, thermomechanical stresses on the receiver limits the operational envelope. One pathway to higher efficiency is greater allowable solar fluxes on the receiver but novel materials are required. The present study uses computational fluid dynamics to describe a parametric design space for a microvascular carbon/carbon composite solar receiver as a new material option for high flux solar receivers. Simulations are conducted for different microvascular geometries considering the role of material properties and heat transfer fluids, for the impact on thermal efficiency, and allowable strain. Results show that microscale receiver modules made of the proposed carbon/carbon composite could achieve thermal efficiencies over 90% and full-scale receivers can achieve up to 85% thermal efficiency for the design explored considering realistic strain limits, flux levels, and material properties. These values are highly dependent on the heat transfer fluid pairing, the through plane thermal conductivity of the carbon/carbon composite, the path architecture of the microscale receiver, and the incident solar flux profiles.

14 SOLAR ENERGY↗

Technical - Coal Gasification Technologies Subtopic d: Hybrid Integrated Concepts for IGCC (with CCS) and Non-Biomass Renewable Energy (e.g. Solar, Wind)

Currently in the United States, there are more than five hundred coal-fired power plants producing a total of 1.5 billion tons of carbon dioxide emissions per year. 1 The total annual CO 2 sequestration and transportation cost for the five hundred coal-fired power plants in the United States can surmount $98.6 billion per year. 2 Therefore, power generation technologies that utilize domestic coal resources while reducing carbon emissions are heavily sought in order to maintain energy security while decreasing greenhouse gas (GHG) emissions. Coal gasification can convert domestic coal resources into syngas which can be used in a combined cycle power block to generate power while reducing GHG emissions. In addition, carbon capture and sequestration technologies are more economical in gasification processes than in direct combustion, which reduces capital and maintenance costs for power generation. Under a Department of Energy (DOE) Small Business Innovative Research (SBIR) program entitled “Hybrid Solar Coal Gasifier”, (Contract number: DE-SC0008355) Advanced Cooling Technologies, Inc. (ACT) designed and developed an innovative, indirectly heated, fuel flexible, heat pipe driven gasification reactor that can be hybridized with concentrated solar power (CSP) towers to further reduce the carbon emissions over current gasification processes. This hybridization of solar and coal gasification technologies helps to bridge the transition from traditional fossil fuel power generation towards systems based on more sustainable, renewable energy resources. The nine month program started on May 28, 2012 and ended March 27, 2013.

01 COAL, LIGNITE, AND PEAT↗

Demonstrating SolarPILOT’s Python API Through Heliostat Optimal Aimpoint Strategy Use Case

SolarPILOT is a software package that generates solar field layouts and characterizes the optical performance of concentrating solar power (CSP) tower systems. SolarPILOT was developed by the National Renewable Energy Laboratory (NREL) as a stand-alone desktop application but has also been incorporated into NREL’s1 System Advisor Model (SAM) in a simplified format. Prior means for user interaction with SolarPILOT have included the application’s graphical interface, the SAM routines with limited configurability, and through a built-in scripting language called “LK.” This paper presents a new, full-featured, Python-based application programmable interface (API) for SolarPILOT, which we hereafter refer to as CoPylot. CoPylot provides access to all SolarPILOT’s capabilities to generate and characterize power tower CSP systems seamlessly through Python. Supported capabilities include (i) creating and destroying a model instance with message reporting tools; (ii) accessing and setting any SolarPILOT variable including custom land boundaries for field layouts; (iii) programmatically managing receiver and heliostat objects with varied attributes for systems with multiple receiver or heliostat types; (iv) generating, assigning, and modifying solar field layouts including the ability to set individual heliostat locations, aimpoints, soiling rates, and reflectivity levels; (v) simulating solar field performance; (vi) returning detailed results describing performance of individual heliostats, the aggregate field, and receiver flux distribution; and, (vii) exporting Python-based model instances to multiple file formats. CoPylot enables Python users to perform detailed CSP tower analysis utilizing either the Hermite expansion technique (analytical) or the SolTrace ray-tracing engine. In addition to CoPylot’s functionality, Python users have access to the over 100,000 open-source libraries to develop, analyze, optimize, and visualize power tower CSP research. This enables CSP researchers to perform analysis that was previously not possible through SolarPILOT’s existing interfaces. This paper discusses the capabilities of CoPylot and presents a use case wherein we demonstrate optimal solar field aiming strategies.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Impact of Temperature and Optical Error on the Combined Optical and Thermal Efficiency of Solar Tower Systems for Industrial Process Heat: Preprint

Concentrating solar thermal (CST) power towers can provide high flux concentrations at commercial scale. As a result, CST towers exhibit potential for high-temperature solar industrial process heat (SIPH) applications. However, at higher operating temperatures, thermal radiation losses can be significant. This study explores the trade-off between thermal and optical losses for SIPH applications using a collection of three case studies at operating temperatures that range from 900-1,550 degrees C. We assume blackbody radiation to represent the thermal losses at the receiver and we use ray tracing to estimate the optical losses. The results show the impact of process temperature on the maximum attainable system efficiency, as well as the higher flux concentration requirements as the temperature increases.

concentrating solar power↗

Status Quo and Gap Analysis of Heliostat Field Deployment Processes for Concentrating Solar Tower Plants

In this study, deployment of the solar field of a concentrating solar power plant is one of many factors that are integral to the success of a project. Knowledge transfer from outside the industry is limited due to the unique nature of heliostats, which redirect sunlight to a receiver with high precision while maintaining a high level of reflectivity. Moreover, learning from project to project can be limited due to the site-specific nature of projects, as the market includes several developers, each with their own unique design. In this paper, we discuss the state of the art in heliostat field deployment. We cover all the key aspects of deployment from project assessment to a fully functioning system, which include site selection, layout development, supply chain, assembly, site preparation and construction, calibration, and operations and maintenance. We then perform a gap analysis on field deployment and recommend priorities for future research.

14 SOLAR ENERGY↗

Optimizing the CSP Tower Air Brayton Cycle System to Meet the SunShot Objectives - Final Technical Report

The objective of this project is to increase Concentrated Solar Power (CSP) tower air receiver and gas turbine temperature capabilities to 1,000ºC by the development of a novel gas turbine combustor, which can be integrated on a megawatt-scale gas turbine, such as the Solar Turbines Mercury 50™. No combustor technology currently available is compatible with the CSP application target inlet air temperature of 1,000°C. Autoignition and flashback at this temperature prevent the use of conventional lean pre-mix injectors that are currently employed to manage NOx emissions. Additional challenges are introduced by the variability of the high-temperature heat source provided by the field of solar collectors, the heliostat in CSP plants. For optimum energy generation from the power turbine, the turbine rotor inlet temperature (TRIT) should remain constant. As a result of changing heat load provided to the solar collector from the heliostat, the amount of energy input required from the combustion system must be adjusted to compensate. A novel multi-bank lean micro-mix injector has been designed and built to address the challenges of high-temperature combustion found in CSP applications. The multi-bank arrangement of the micro-mix injector selectively injects fuel to meet the heat addition requirements to maintain constant TRIT with changing solar load. To validate the design, operation, and performance of the multi-bank lean micro-mix injector, a novel combustion test facility has been designed and built at Southwest Research Institute® (SwRI®) in San Antonio, TX. This facility, located in the Turbomachinery Research Facility, provides in excess of two kilograms per second of compressed air at nearly eight bar pressure. A two-megawatt electric heater raises the inlet temperature to 800°C while a secondary gas-fired heater extends the operational temperature range of the facility to 1,000°C. A combustor test rig connected to the heater has been designed and built to test the multi-bank lean micro-mix injector over the range of CSP operating conditions. The fuel is controlled and selectively delivered to the banks of the injector based on combustor inlet conditions that correspond to turbine operating points. The combustor rig is equipped with a data acquisition system and a suite of instrumentation for measuring temperature, pressure, and species concentration. This unique test facility has been built and commissioned and a prototype of the multi-bank lean micro-mix injector design has been tested. Operation of the combustor and injector has been demonstrated over the full range of CSP inlet conditions and for the range of turbine load conditions specified. The multi-bank operation of the injector has been proven to be an effective design for managing the variable flow rates of air and fuel due to changing inlet conditions from the solar field and turbine loads.

14 SOLAR ENERGY↗

A non-intrusive optical approach to characterize heliostats in utility-scale power tower plants: Flight path generation/optimization of unmanned aerial systems

A newly developed in situ non-intrusive optical (NIO) approach has been developed to survey various types of heliostat optical errors for a concentrating solar power (CSP) tower plant. To measure mirror surface slope error, facet canting error, and heliostat tracking error at a sub-milliradian accuracy, NIO requires several reflection images scanned over each individual heliostat. For a utility-scale plant that typically includes more than 10,000 heliostats, an unmanned aerial system (UAS) is crucial for efficient implementation of the NIO method. Here, we develop a flight path generation/optimization algorithm to plan more efficient UAS paths to collect NIO data over a utility-scale heliostat field. The algorithm considers NIO data requirements, all potential constraints, optimization within each subfield, and operational flexibility. Case studies are presented to illustrate the feasibility and robustness of the developed flight path algorithm. The path planning algorithm may also find applications elsewhere, such as drone-driven imaging under extreme conditions.

14 SOLAR ENERGY↗

Demonstrating SolarPILOT's Python API Through Heliostat Optimal Aimpoint Strategy Use Case: Preprint

SolarPILOT is a software package that generates heliostat field layouts and characterizes the optical performance of concentrating solar power (CSP) tower systems. SolarPILOT was developed by the National Renewable Energy Laboratory (NREL) as a stand-alone desktop application but has also been incorporated into NREL's System Advisor Model (SAM) in a simplified format. Prior means for user interaction with SolarPILOT have included the application's graphical interface, the SAM routines with limited configurability, and through a built-in scripting language called "LK." This paper presents a new, full-featured Python-based application programmable interface (API) for SolarPILOT, which we hereafter refer to as CoPylot. CoPylot provides access to all SolarPILOT's capabilities to generate and characterize power tower CSP systems seamlessly through Python. Supported capabilities include (i) creating and destroying a model instances with message reporting tools; (ii) accessing and setting any SolarPILOT variable including custom land boundaries for field layout; (iii) programmatically managing receiver and heliostat objects with varied attributes for systems with multiple receiver or heliostat types; (iv) generating, assigning, and modifying heliostat field layouts including the ability to set individual heliostat locations, aimpoints, soiling rates, and reflectivity levels; (v) simulating heliostat field performance; (vi) returning detailed results describing performance of individual heliostats, the aggregate field, and receiver flux; and, (vii) exporting Python-based model instances to multiple file formats. CoPylot enables Python users to perform detailed tower CSP analysis utilizing either the Hermite expansion technique (analytical) or the SolTrace ray-tracing engine. In addition to CoPylot's functionality, Python users have access to the over 100,000 open-source libraries to develop, analyze, optimize, and visualize CSP tower research.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Dispatch optimization of concentrating solar power with utility-scale photovoltaics

Concentrating solar power (CSP) tower technologies capture thermal radiation from the sun utilizing a field of solar-tracking heliostats. When paired with inexpensive thermal energy storage (TES), CSP technologies can dispatch electricity during peak-market-priced hours, day or night. The cost of utility-scale photovoltaic (PV) systems has dropped significantly in the last decade, resulting in inexpensive energy production during daylight hours. The hybridization of PV and CSP with TES systems has the potential to provide continuous and stable energy production at a lower cost than a PV or CSP system alone. Hybrid systems are gaining popularity in international markets as a means to increase renewable energy portfolios across the world. Typically, CSP-PV hybrid systems have been evaluated using either monthly averages of hourly PV production or scheduling algorithms that neglect the time-of-production value of electricity in the market. To more accurately evaluate a CSP-PV-battery hybrid design, we develop a profit-maximizing mixed-integer linear program ($\mathcal{H}$) that determines a dispatch schedule for the individual sub-systems with a sub-hourly time fidelity. We introduce the mathematical formulation of such a model and show that it is computationally expensive to solve. To improve model tractability and reduce solution times, we offer techniques that: (1) reduce the problem size, (2) tighten the linear programming relaxation of ($\mathcal{H}$) via reformulation and the introduction of cuts, and (3) implement an optimization-based heuristic (that can yield initial feasible solutions for (($\mathcal{H}$) and, at any rate, yields near-optimal solutions). Applying these solution techniques results in a 79% improvement in solve time, on average, for our 48-h instances of (($\mathcal{H}$); corresponding solution times for an annual model run decrease by as much as 93%, where such a run consists of solving 365 instances of (($\mathcal{H}$), retaining only the first 24 h' worth of the solution, and sliding the time window forward 24 h. We present annual system metrics for two locations and two markets that inform design practices for hybrid systems and lay the groundwork for a more exhaustive policy analysis. A comparison of alternative hybrid systems to the CSP-only system reflects that hybrid models can almost double capacity factors while resulting in a 30% improvement related to various economic metrics.

14 SOLAR ENERGY↗

A non-intrusive optical (NIO) approach to characterize heliostats in utility-scale power tower plants: Methodology and in-situ validation

No reliable in-situ optical characterization tool is available that can efficiently and accurately measure various optical errors of individual heliostats in a utility-scale power-tower plant. Here, an innovative non-intrusive optical (NIO) approach is proposed to measure mirror surface slope error, mirror facet canting error, and heliostat tracking error based on reflection images using the natural target—the tower—in a heliostat field. The NIO approach adopts various techniques in photogrammetry, reflectometry, and geometrical optics to first determine the camera position and the actual tower position with respect to the heliostat. Then, Snell’s law is applied to find the surface normal at the reflection point or line of a reflection image and derive the surface slope error, mirror facet canting error, and heliostat tracking error accordingly. In addition, an in-situ validation is performed to demonstrate the feasibility of the NIO approach. Analysis with multiple sets of reflection images on one single heliostat of interest demonstrates that the NIO method can achieve a measurement uncertainty of 0.22 mrad for mirror facet slope error (root-mean-square) at the given test conditions. The sensitivity of measurement uncertainty to various parameters will be presented in a separate work. In the future, state-of-the-art unmanned aerial systems (UAS) are planned to perform the efficient image collection with a goal to complete the survey across a utility-scale field of over 10,000 heliostats within one or a few days depending on the number of UASs. The development of the NIO approach is expected to fill the critical gap for successful solar-field operation and maintenance, which is necessary for the global growth of the solar power-tower technology. The NIO approach can also be applied to any relevant industry requiring high-precision mirror surface shape characterization.

14 SOLAR ENERGY↗

AATTENUATION—The Atmospheric Attenuation Model for CSP Tower Plants: A Look-Up Table for Operational Implementation

Attenuation of solar radiation between the receiver and the heliostat field in concentrated solar power (CSP) tower plants can reduce the overall system performance significantly. The attenuation varies strongly with time and the average attenuation at different sites might also vary strongly from each other. If no site specific attenuation data is available, the optimal plant design cannot be determined and rough estimations of the attenuation effect are required leading to high uncertainties of yield analysis calculations. The attenuation is caused mainly by water vapor content and aerosol particles in the lower atmospheric layer above ground. Although several on-site measurement systems have been developed during recent years, attenuation data sets are usually not available to be included during the plant project development. An Atmospheric Attenuation (AATTENUATION) model to derive the atmospheric transmittance between a heliostat and receiver on the basis of common direct normal irradiance (DNI), temperature, relative humidity, and barometric pressure measurements was developed and validated by the authors earlier. The model allows the accurate estimation of attenuation for sites with low attenuation and gives an estimation of the attenuation for less clear sites. However, the site-dependent coefficients of the AATTENUATION model had to be developed individually for each site of interest, which required time-consuming radiative transfer simulations, considering the exact location and altitude, as well as the pre-dominant aerosol type at the location. This strongly limited the application of the model despite its typically available input data. In this manuscript, a look-up table (LUT) is presented which enables the application of the AATTENUATION model at the site of interest without the necessity to perform the according complex radiative transfer calculations for each site individually. This enables the application of the AATTENUATION model for virtually all resource assessments for tower plants and in an operational mode in real time within plant monitoring systems around the world. The LUT also facilitates the generation of solar attenuation maps on the basis of long-term meteorological data sets which can be considered during resource assessment for CSP tower plant projects. The LUTs are provided together with this manuscript as supplementary files. The LUT for the AATTENUATION model was developed for a solar zenith angle (SZA) grid of 1°, an altitude grid of 100 m, 7 different standard aerosol types and the standard AFGL atmospheres for mid-latitudes and the tropics. The LUT was tested against the original version of the AATTENUATION model at 4 sites in Morocco and Spain, and it was found that the additional uncertainty introduced by the application of the LUT is negligible. With the information of latitude, longitude, altitude above mean sea level, DNI, relative humidity (RH), ambient temperature (Tair), and barometric pressure (bp), the attenuation can be now derived easily for each site of interest.

14 SOLAR ENERGY↗

Demonstrating solarpilot ’s Python Application Programmable Interface Through Heliostat Optimal Aimpoint Strategy Use Case

solarpilot is a software package that generates solar field layouts and characterizes the optical performance of concentrating solar power (CSP) tower systems. solarpilot was developed by the National Renewable Energy Laboratory (NREL) as a stand-alone desktop application but has also been incorporated into NREL’s System Advisor Model (SAM) in a simplified format. Prior means for user interaction with solarpilot have included the application’s graphical interface, the SAM routines with limited configurability, and through a built-in scripting language called “LK.” This article presents a new, full-featured, python-based application programmable interface (API) for solarpilot, which we hereafter refer to as CoPylot. CoPylot enables python users to perform detailed CSP tower analysis utilizing either the Hermite expansion technique (analytical) or the SolTrace ray-tracing engine. CoPylot’s enables CSP researchers to perform analysis that was previously not possible through solarpilot’s existing interfaces. This article discusses the capabilities of CoPylot and presents a use case wherein we populate a model that obtains optimal solar field aiming strategies.

14 SOLAR ENERGY↗

Evaluation of external tubular configurations for a high-temperature chloride molten salt solar receiver operating above 700°C

Next-generation concentrating solar power (CSP) tower technologies target operating temperatures exceeding 700°C to increase the thermal-to-electric conversion efficiency. Molten chloride salts are one possible alternative to current commercial molten nitrate salts to enable the higher operating temperature. This paper analyzes the predicted optical, thermal-fluids, and structural performance of traditional external tubular solar receiver configurations applied with a chloride salt heat transfer fluid (HTF) and inlet/outlet temperatures of 500°C/735°C, and considers sensitivity analysis and optimization relative to receiver sizing, tube sizing, number of panels, flow circuit configurations, and solar flux concentration under constraints on internal velocity, pressure drop, wall thickness, and required creep-fatigue lifetime. The high temperature conditions increase the significance of inelastic deformation mechanisms such as creep relative to that expected in commercial 565°C nitrate salt designs. High-temperature creep and creep-fatigue damage in the metal alloy tubes are the key factors that limit allowable solar flux concentration and achievable receiver thermal efficiency at the near-800°C wall temperature conditions. For a traditional external cylindrical receiver configuration, the design parameters and conditions capable of satisfying all constraints produced, at best, a design point receiver efficiency of 78.2%, or 80.5% when excluding receiver intercept efficiency. Variation in the optimal receiver performance relative to uncertainty in the binding maximum velocity, minimum wall thickness, and minimum lifetime constraints is presented.

14 SOLAR ENERGY↗

Case Studies and Parametric Analysis of Heliostat Performance With a Tradeoff-Informed Technoeconomic Analysis Metric

The Heliostat Consortium (HelioCon) was launched in 2021 to advance heliostat technology. Here this work presents a collection of baseline case studies for the technoeconomic analysis (TEA) of candidate heliostat improvements for concentrating solar power (CSP) and concentrated solar thermal (CST) systems that employ central receivers. The case studies we develop include a large-scale CSP plant, a smaller, modular CSP plant, and a small CST plant used for industrial process heat. In this work, we also propose a novel metric for TEA of a plant component technology that recasts relative changes in levelized system costs into component-specific capital cost budgets. This measure, which we refer to as the equivalent breakeven installed cost, is the maximum budget for the technology component that leads to improved levelized costs. Finally, we perform a parametric analysis to show the impact of candidate technologies on the levelized cost of heat and, by extension, equivalent breakeven installed cost.