Search NASA⌕ Search

SEARCH · Search NASA

Results for “Space Heating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

An assessment of existing barriers to market adoption of thermal energy storage in buildings based on interviews with stakeholders

The United States administration recently established a goal of reducing greenhouse gas emissions by half below 2005 levels by 2030 and becoming a carbon-neutral economy by 2050. The transition to renewable energy sources may be significantly aided by energy storage. Energy storage could smooth the delivery of variable or intermittent renewable energy sources such as wind, hydro, and sun by storing excess renewable energy when it’s available and delivering it back when renewable energy production is low. Thermal energy storage (TES) is a way that stores thermal energy by heating or cooling a storage medium, which is then used for space heating and cooling, industrial processes, or power generation purposes later. This TES operation could lessen the demand for electricity in both the winter's and the summer's peak hours of electricity. While there are various studies that focus on the advancements and successes of TES technology, less attention is placed on its market adoption. Therefore, the current study undertakes survey-based interview research to understand the existing market barriers hindering TES application in buildings. A series of interviews were performed in this study with individuals from various backgrounds, ranging from homeowners to market specialists who work for TES manufacturers and utility companies. According to the responses obtained during the interviews, they strongly believe that TES has a high potential to contribute to the nation's grid stability and decarbonization goals, however, there are several barriers that prevent homeowners and heat pump manufacturers from investing in TES applications. The current study divided the responses from various background groups into categories to better understand the current challenges for TES applications in buildings. These responses range from payback concerns from homeowners to the need to develop a new metric to represent the benefits of TES from the heat pump and TES manufacturers. The findings from this study can be used by policymakers, utility companies, and manufacturers to better understand present obstacles and develop strategies to overcome them.

Prem Anand Jayaprabha, Jyothis Anand↗

Ductless Heat Pump Energy Monitoring in a Cold Climate

In 2018, the City and Borough of Juneau, Alaska set the goal of reaching 80% renewable energy for heating and transportation by 2045. An important factor to help reach this goal is finding energy efficiency home heating technologies such as ductless air source heat pumps (DHPs), which rely on the local hydropower electric grid to provide space heating for an entire home or a main living area. To help residents reduce energy costs and move toward the community renewable energy goal, a team of local, state, and national partners joined to run Thermalize Juneau 2021, an energy campaign that provided education, a simplified installation process, and a bulk purchase discount. Overall, the campaign enrolled 165 participants, resulting in 75 DHP installations and over 30 energy efficiency improvements. To evaluate the reliability and energy use of the DHPs installed during the Thermalize Juneau campaign, researchers installed energy monitors on heat pumps of 14 participants and conducted interviews with homeowners. Data from two heating seasons (2021-2022 and 2022-2023) has allowed researchers to examine the accuracy of pre-campaign energy savings predictions, establish energy savings for a small group of households, and provide insights on the energy use and occupant satisfaction of DHPs which will help to inform future heat pump deployment efforts in the area.

air source heat pump↗

Ductless Heat Pump Energy Monitoring in a Cold Climate

In 2018, the City and Borough of Juneau, Alaska, set the goal of reaching 80% renewable energy for heating and transportation by 2045. An important factor to help reach this goal is energy-efficient home heating technologies such as ductless air- source heat pumps (DHPs), which rely on the local hydropower electric grid to provide space heating for an entire home or a main living area. To help residents reduce energy costs and move toward the community renewable energy goal, a team of local, state, and national partners joined together to run Thermalize Juneau 2021, an energy campaign that provided education, a simplified installation process, and a bulk purchase discount. Overall, the campaign enrolled 165 participants, resulting in 75 DHP installations and over 30 other energy efficiency improvements. To evaluate the reliability and energy use of the DHPs installed during the Thermalize Juneau campaign, researchers installed energy monitors on heat pumps of 14 participants and conducted interviews with homeowners. Data from two heating seasons (2021-2022 and 2022-2023) allowed researchers to examine the accuracy of pre-campaign energy savings predictions, establish energy savings for a small group of households, and provide insights on the energy use and occupant satisfaction of DHPs, which will help inform future heat pump deployment efforts in the area.

air source heat pump↗

Hybrid Solar Heat Generation Modelling and Cases: Preprint

Renewable thermal energy systems (RTES) harness renewable energy sources to provide services for space heating and cooling, district heating, domestic hot water, and industrial process heat (IPH). The use of low-pressure steam generated by the combustion of fossil fuels is common today to provide process heat for industrial facilities. Solar IPH (SIPH) technologies could economically replace the steam or heat needs at many industrial sites by providing high-temperature pressurized hot water, a heat transfer fluid (HTF) such as synthetic-oil, or direct steam (Kurup and Turchi, 2015). RTES could be hybridized with technology options or combined with the existing heat supply (e.g. fuels), to give options for targeted IPH application and the reduction of fuel consumption. This work has tested hybrid system modelling approaches. Initial results show when a natural gas (NG) burner that feeds an IPH application of 300°C, has both air and NG streams pre-heated with a solar field/RTES exit temperature of 180°C (via an HTF), a 13% NG offset is possible. NG offsets reach up to 26%, when the RTES exit temperatures are at 300°C for a given annual capacity factor of 24%. This can be even higher with addition of thermal energy storage (TES).

43 PARTICLE ACCELERATORS↗

A critical review of electrochemical heat pump technologies: Status, challenges, and perspectives

The development of advanced heat pump technologies is critical for reducing global energy consumption in the building sector, where space heating and cooling account for nearly 50% of energy use. Electrochemical heat pumps (EHPs) offer a promising alternative to vapor compression systems by enabling direct electrochemical-to-thermal energy conversion, often with environmentally benign working fluids that exhibit low or zero global warming potential (GWP). Prior literature has predominantly focused on chemically reactive heat pumps, while comprehensive assessments of electrochemical mechanisms remain limited. Here, this review addresses this gap by systematically evaluating the underlying principles, architectures, and performance metrics of EHP systems. Compared to conventional vapor compression systems, EHPs can achieve 10%-30% higher energy efficiency, with reported cooling coefficients of performance (COP c ) ranging from 3.5 to 14.3 under standard operating conditions. Despite these advantages, widespread adoption is hindered by challenges including membrane degradation, electrode fouling, sluggish redox kinetics, and elevated system-level capital costs. To address these limitations, the review outlines three research priorities: (i) the development of advanced membranes, catalysts, and electrode materials with enhanced chemical and mechanical stability; (ii) the application of molecular-level simulations for the rational design of high-performance redox-active working fluids; and (iii) the integration of advanced diagnostic techniques for real-time monitoring and sustained operation of EHPs. By consolidating recent advances and explicitly identifying technological and scientific gaps, this work uniquely contributes a comprehensive framework for guiding future electrochemical heat pump research and facilitating the transition to sustainable thermal management technologies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Benefits of Dual Fuel Heat Pump Grid-responsive Control: A Model-based Control Optimization Approach Using Building and Equipment Co-simulation

Conventional dual fuel heat pumps lack the intelligent control mechanisms to efficiently manage the switch between heat pump and furnace, leading to sub-optimal energy usage and, in some cases, increased operating costs. To resolve this gap, this study applies optimized control on hybrid heat pumps. With a focus on equipment control strategies, we compare the performances of five spacing heating equipment, including a conventional heat pump (HP), a conventional furnace, a dual fuel heat pump (DFHP) with conventional control, a dual fuel heat pump with smart control, and a novel seamlessly fuel flexible heat pump (SFFHP). While DFHP runs on either gas or electricity at any given moment, SFFHP concurrently consumes gas and electricity by continuously optimizing the proportion of each. In this research, a co-simulation framework is developed by integrating a building envelope model with a physics-based heat pump simulation model to analyze the benefits of grid-responsive controls of DFHP and SFFHP. The model-based optimal controls adjust the operation of the heat pump and gas furnace based on utility price signals and marginal grid emission to minimize utility cost and CO 2 emissions for multiple climate zones, different utility tariffs, and marginal grid emission scenarios. Case studies in Chicago and Los Angeles demonstrate that SFFHP and DFHP, with model-based optimal control, can deliver significant reductions in peak demand, utility cost, and CO 2 emission. In Chicago, SFFHP and smart controlled DFHP yield up to 64.7% and 61.7% utility cost reduction and up to 15.7% and 8.5% CO 2 emission reduction compared to the gas furnace. In Los Angeles, SFFHP and smart controlled DFHP achieve up to 43.6% and 40.1% utility cost reduction and up to 13.8% and 14.1% CO2 emission reduction compared to conventional heat pumps. In conclusion, by leveraging the fuel flexibility nature of dual fuel heat pumps, the model-based control optimization approach makes dual fuel heat pump an attractive option for demand response programs.

Control↗

A Numerical Modelling Study on Submerged Condensers for Heat Pump Water Heaters Using Low-GWP Refrigerants

Challenges to global warming require reduction of GHG emissions, and increased use of renewable energy. Heat pumps extract energy from renewable sources and convert them to more useable forms for space conditioning, space heating and for water heating. They can be powered by renewable sources of electricity and must be engineered to use low global warming potentials (GWP) refrigerants (e.g., propane, GWP = 3) for a sustainable economy. Therefore, an electric heat pump water heaters (HPWH) using propane as refrigerant are developed in Oak Ridge National Laboratory to replace water heaters using all electric resistance and natural gas. A submerged condenser directly contacting with water is employed in the HPWH, which eliminates heat transfer barrier of the tank wall, and also prevents heat loss from the condenser tubes to the surrounding air. In present work, a numerical model is developed to model the submerged condenser. A dynamic temperature distribution on the condenser tubes from experimental data is applied to the model to enhance the accuracy of the numerical model. The model is essential to guide the design of the submerged condenser to achieve the performance required by the HPWH.

Zhang, Mingkan↗

Techno-Economic Assessment of Residential Heat Pump Integrated with Thermal Energy Storage

Phase change material (PCM)-based thermal energy storage (TES) can provide energy and cost savings and peak demand reduction benefits for grid-interactive residential buildings. Researchers established that these benefits vary greatly depending on the PCM phase change temperature (PCT), total TES storage capacity, system configuration and location and climate of the building. In this study, preliminary techno-economic performance is reported for a novel heat pump (HP)-integrated TES system using an idealized approach. A simplified HP-TES was modeled for 1 year of space heating and cooling loads for a residential building in three different climates in the United States. The vapor compression system of the HP was modified to integrate with TES, and all heat transfer to and from the TES was mediated by the HP. A single PCM was used for heating and cooling, and the PCT and TES capacity were varied to observe their effects on the building’s energy consumption, peak load shifting and cost savings. The maximum reduction in electric consumption, utility cost and peak electric demand were achieved at a PCT of 30 °C for New York City and 20 °C for Houston and Birmingham. Peak energy consumption in Houston, New York City, and Birmingham was reduced by 47%, 53%, and 70%, respectively, by shifting peak load using a time-of-use utility schedule. TES with 170 MJ storage capacity allowed for maximum demand shift from on-peak to off-peak hours, with diminishing returns once the TES capacity equaled the daily building thermal loads experienced during the most extreme ambient conditions.

25 ENERGY STORAGE↗

Potential of Utilizing Thermal Energy Storage Integrated Ground Source Heat Pump System to Reshape Electricity Demand in the United States

Each year, more than 20% of electricity generated in the United States is consumed for meeting the thermal demands (e.g., space cooling, space heating, and water heating) in residential and commercial buildings. Integrating thermal energy storage (TES) with building’s HVAC systems has the potential to reshape the electric load profile of the building and mitigate the mismatch between the renewable generation and the demand of buildings. A novel ground source heat pump (GSHP) system integrated with underground thermal energy storage (UTES) has been proposed to level the electric demand of buildings while still satisfying their thermal demands. This study assessed the potential impacts of the proposed system with a bottom-up approach. The impacts on the electricity demand in various electricity markets were quantified. The results show that, within the capacity of the existing electric grids, the maximum penetration rate of the proposed system in different wholesale markets could range from 51% to 100%. Altogether, about 46 million single-family detached houses can be retrofitted into the proposed system without increasing the annual peak demand of the corresponding markets. By implementing the proposed system at its maximum penetration rate, the grid-level summer peak demand can be reduced by 9.1% to 18.2%. Meanwhile, at the grid level, the annual electricity consumption would change by –12% to 2%. The nationwide total electricity consumption would be reduced by 9%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multifunctional Heat Pump with Energy Storage Capability

Replacing gas furnaces with heat pumps on a large scale can pose challenges to the electrical grid. It will significantly increase the demand, strain the electrical grid, especially during peak usage times. To ensure that heat pumps contribute to reducing emissions, it's essential to increase the share of renewable energy in the grid. However, the supply of renewable energy is unstable. Large scale of electrification must address the concern of grid resilience to meet necessary heating/cooling demands and shift peak electric load. All these require future heat pumps having energy storage capability. These systems can store excess energy during low-demand periods and release it during high-demand periods, reducing stress on the grid. This paper will introduce an innovative configuration, control, and laboratory investigations of a multifunctional packaged heat pump. In addition to the original indoor and outdoor air coils, the heat pump has a parallel hydronic loop with a brazed plate heat exchanger (BHP). The hydronic loop circulates hot/chilled water to store heating/cooling energy in phase change material (PCM). It is capable of space cooling, space heating, cooling energy storage/defrosting, water heating/heating energy storage with outdoor air source or indoor air source, and cooling/heating energy free discharge. The laboratory studies and breadboard unit are presented. Additionally, building energy simulation demonstrates utility cost reduction potential via charging PCM panels/ceilings during off-peak hours and releasing the energy during peak hours to mitigate the peak power consumption.

Shen, Bo↗

Assessing the impacts of air-sealing on the sizing, operation, and economic feasibility of ground-source heat pumps for electrifying single-family houses in the US

According to recent studies and reports, in single-family houses (SFHs), air-sealing can significantly lower the thermal loads for space heating and cooling. Thus, air-sealing in SFHs could reduce the required size and cost of ground source heat pump (GSHP) systems for electrifying SFHs. Here, this study investigated the costs and benefits of integrating air-sealing with GSHPs for retrofitting existing SFHs when compared with air-source heat pumps. A whole building energy simulation tool integrated with an advanced design tool for modeling ground heat exchangers was used to calculate changes in required GSHP capacity, total borehole length, and building energy consumption with and without air-sealing in SFHs in 16 US climatic regions. The results from this study showed that reducing outdoor air infiltration from 0.8 air changes per hour (ACH) to the minimum ventilation requirement (0.35 ACH) can significantly reduce borehole length (up to 55 %), GSHP capacity (up to 48 %), and total heating electricity reduction, especially in cold climates (up to 44 %). The results also showed that for airtight homes (0.03 ACH infiltration) with a direct outdoor air system, the minimum required borehole length, GSHP capacity, and total heating electricity consumption can be reduced up to 70 %, 68 %, and 67 %, respectively, when compared with SFHs with 0.8 ACH infiltration. Moreover, the life cycle cost analysis showed that air-sealing in conjunction with a GSHP is more profitable than replacing the existing system with an air-source heat pump, even without any incentives for most climatic regions in the US (except for some hot regions).

15 GEOTHERMAL ENERGY↗

From models to reality: a systematic review on simulated and measured residential heat pump energy savings

High-performance HVAC solutions are central to residential energy management. A substantial share of these are electric, reversible-cycle systems, with heat pumps representing the largest portion of current and near-term adoption. This review synthesizes peer-reviewed and grey literature on residential space heating and cooling heat pumps. The academic literature is dominated by modeling (73.8%), with limited field measurement (13.1%). Grey literature from United States serve as a supplemental resource providing measured savings. Conversions from electric-resistance heating consistently show the largest site energy reductions, while oil/propane baselines yield moderate savings, and gas baseline scenario often deliver small and region-dependent savings. This study cross-checks the grey literature measured data with simulation data filtered from the ResStock dataset. The comparison indicates a discrepancy between simulations and measured data: simulated site EUIs are typically lower than measured EUIs, but percentage energy savings fall in similar ranges, implying simulations capture directional effects while underestimating energy use. Factors associated with variability and model–measurement differences include system characterization and control representation (e.g., backup heat engagement, thermostat/setpoint strategies, commissioning/installation quality), occupant behavior, weather normalization, metering scope, and envelope characterization. This paper also outlines the proposed methodology for comparing simulation and measured data for heat pumps. It emphasizes the metrics used for comparison and units harmonization, building characteristics matching, and compact metadata are needed for simulations to match measured data. The proposed methodology is expected to improve the credibility of simulated savings as measured evidence grows.

Yu, Lili↗

Overview of Building Electrification Technologies and Market Opportunities

This report provides an overview of building electrification drivers and select building electrification technologies and their markets and performance. Covered topics: Building Electrification Drivers and Context; Heat Pumps for Space Conditioning; Heat Pump Market Opportunities; Life Cycle GHG Emissions Impacts of Heat Pump Space Conditioning Technologies; Heat Pump Water Heaters; Electrification of Gas Loads: Commercial and Residential; Residential Panel Capacity; Electric Vehicle Impacts and Connections to Buildings; and Building Envelope Improvements and Thermal Energy Storage (TES) Opportunities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Perform Life Cycle Energy and GHG Emission Analysis, Select Candidate Refrigerant(s), Developing Heat Pump by Using Low-GWP Refrigerants and 5 mm Diameter Tubes

Reducing environmental impacts from the energy conversion systems has been an important research topic due to recent severe global climate changes. In residential buildings, the space heating and cooling are main energy consumers, which are relying on vapor compression based heat pumps. To mitigate the environmental impacts of residential systems, the heat pumps using low-GWP refrigerants and 5mm-tube heat exchangers are proposed to replace the conventional 9 mm or 7 mm tube heat exchangers. This research uses a simulation-based design method to optimize the refrigerant circuitries of a 5-ton low-GWP refrigerant heat pumps whose indoor and outdoor heat exchangers adopt 5 mm tubes. Heat pump systems using four commercially available low-GWP refrigerants (R454A, R454C, ARM20A and ARM20B) are optimized and compared with the baseline R410A system. The results indicate that directly replacing 9 mm tubes into 5mm tubes in the baseline systems induces heat pump performance degradation; by optimizing the 5 mm tube heat pumps with added tube rows, the system refrigerant charge is reduced up to 33% compared with the baseline; the optimized low-GWP 5 mm tube heat pumps offer the same or higher performance under both cooling and heating mode; that under cooling mode, the EER improvement is up to 10.7% and under heating mode the COP improvement is up to 3.4%; and a smart flow control device to maintain counter-flow circuitry pattern on both operating modes can improve the heating performance of 5 mm tube optimized system by up to 3.0%. In an effort to better understand the environmental impacts of these systems, life cycle climate performance (LCCP) evaluation method is used to assess the baseline and optimized systems. LCCP considers the direct and indirect emissions of the system over the course of its lifetime from manufacturing to disposal. Our analyses indicate that the optimized systems using 5mm tubes and low-GWP refrigerants can reduce life-cycle CO 2 emission significantly. And improving system efficiency is the most effective way to reduce the emission of low-GWP refrigerant systems. This report shows that using 5 mm diameter tubes in heat exchangers is a feasible approach to develop heat pumps with low-GWP refrigerants. Using the proposed design approach can yield higher system efficiency with lower environmental impact.

42 ENGINEERING↗

Carbon Mitigation Potential of Heat Pump Integrated with Thermal Storage for Grid-Interactive Residential Buildings

Residential buildings’ heating and cooling loads are associated with significant carbon emissions and peak electricity demand. Phase change material (PCM) based thermal energy storage (TES) can be used for space heating and cooling by embedding into the heat pump equipment. Past work on TES integrated with heat pumps (HP) has demonstrated significant load shifting and economic benefits. However, the potential for TES to reduce carbon emissions has not been widely explored. This study evaluates carbon mitigation potential of an ice-based TES coupled to HP (HP-TES) based on a simple rule-based control strategy accounting for electric grid emissions data. A vapor compression HP model using Engineering Equation Solver (EES). The modeled HP-TES system for single-family residential building demonstrates decreased carbon emissions with reduced peak utility cost.

Sultan, Sara↗

Impact on Cycle Efficiency of Small CHP Plants from Increasing Firing Temperature Enabled by AM of Turbine Blades

Combined Heat and Power (CHP) systems are gaining popularity because of their potential for high overall thermodynamic efficiency and increased need for distributed power generation. Most CHP systems include a gas turbine for electricity generation and a heat recovery steam generator (HRSG) for steam generation. The steam can be used to power a steam turbine for additional electricity generation or to drive rotating equipment, for space heating, for absorption chillers, etc. A CHP cycle configuration is often driven by the ‘principal’ utility for the facility that it services; steam or electricity. In either case, performance improvements in the gas turbine have the potential to increase the steam and power output from the cycle, which is a direct result of improvements in the gas turbine efficiency and power output. One possible opportunity to improve an existing gas turbine’s performance is to increase the firing temperature with improved turbine cooling and increased compression ratio.<br>In this study, the impact on CHP cycle performance from increasing the turbine firing temperature by 100 °C and improving the turbine blade cooling for a 6-MW scale gas turbine is estimated using an analytical cooled gas turbine model and a steam cycle model. A sensitivity analysis was performed to understand the impact of increasing the internal cooling effectiveness, thermal barrier coating performance and blade material upgrades on gas turbine and CHP cycle efficiency. The impacts of turbine blade cooling improvements were studied for three common CHP cycle configurations identified from the literature. Various definitions for CHP cycle efficiency from the literature are used in the comparisons. The results showed that a 100 °C increase in firing temperature can increase the gas turbine efficiency by 1 percentage point without improving cooling effectiveness and add 2 additional percentage points in efficiency by using advanced turbine blades with higher internal cooling efficiency. Studied engine upgrades showed potential for increasing the CHP cycle efficiency by 3 percentage points while increasing the steam generation rate by 8%.<br>

Uysal, Selcuk Can↗

Grid Cost and Total Emissions Reductions Through Mass Deployment of Geothermal Heat Pumps for Building Heating and Cooling Electrification in the United States

This report presents the results of a study on the potential grid impacts of national-scale mass deployment of geothermal heat pumps (GHPs) coupled with weatherization in single-family homes (SFHs) from 2022 to 2050. GHPs are a technology readiness level 10, commercially available technology across the United States. This study is an impact analysis only; installed costs and available land areas for installing GHPs are not accounted for in determining their estimated deployment. The three scenarios studied were (1) continuing to operate the grid as it is today (the Base scenario), (2) a scenario to reach 95% grid emissions reductions by 2035 and 100% clean electricity by 2050 (the Grid Decarbonization scenario), and (3) a scenario in which the Grid Decarbonization scenario is expanded to include the electrification of wide portions of the economy, including building heating (the Electrification Futures Study or EFS scenario). The analysis team modeled each of these three scenarios with and without GHP deployment to a large percentage of US building floor space. In all cases, deployment of approximately 5 million GHPs per year demonstrated system cost savings on the grid, consumer fuel cost savings through eliminated fuel combustion for space heating, and CO 2 emission reductions from avoided on-site fuel combustion—and, in the case of the Base scenario, CO 2 emissions reductions from the electric power sector. GHPs have traditionally been viewed as a building energy technology. The most notable result of this study, however, is the demonstration that GHPs coupled with weatherization in SFHs are primarily a grid cost reduction tool and technology that, when deployed at a national scale, also substantially reduces CO 2 emissions, even in the absence of any other decarbonization policy.

15 GEOTHERMAL ENERGY↗

PCM Selection for Heat Pump Integrated with Thermal Energy Storage for Demand Response in Residential Buildings

Phase Change Materials (PCM) based Thermal energy storage (TES) is a widespread solution to shift buildings’ peak energy demand and add stability to the grid. PCMs can be used for space heating and cooling applications in residential buildings by integrating into the heat pump equipment or building envelope via several possible configurations. The heat pump integrated active PCM storage can provide significant energy savings and reduce peak demand, but the benefits vary substantially depending on the system configuration, storage capacity, and the temperature range of the PCM used. It is critical to provide a review of the materials and their suitability in heat pump integrated PCM systems. This paper will present an analysis of the PCM material selection for heat pump integrated TES in various configurations. The comprehensive review will compare the phase change materials with different melting temperatures, and configurations, corresponding to the energy savings and demand impact reported in the literature. This work is significant to guide the design of high-performance heat pump integrated PCM systems.

Sultan, Sara↗