Search NASA⌕ Search

SEARCH · Search NASA

Results for “Space Medicine”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

78 records · Page 5

Initial Steps Towards a Clinical FLASH Radiotherapy System: Pediatric Whole Brain Irradiation with 40 MeV Electrons at FLASH Dose Rates

In this work, we investigated the delivery of a clinically acceptable pediatric whole brain radiotherapy plan at FLASH dose rates using two lateral opposing 40-MeV electron beams produced by a practically realizable linear accelerator system. The EGSnrc Monte Carlo software modules, BEAMnrc and DOSXYZnrc, were used to generate whole brain radiotherapy plans for a pediatric patient using two lateral opposing 40-MeV electron beams. Electron beam phase space files were simulated using a model of a diverging beam with a diameter of 10 cm at 50 cm SAD (defined at brain midline). The electron beams were collimated using a 10-cm-thick block composed of 5 cm of aluminum oxide and 5 cm of tungsten. For comparison, a 6-MV photon plan was calculated with the Varian AAA algorithm. Electron beam parameters were based on a novel linear accelerator designed for the PHASER system and powered by a commercial 6-MW klystron. Calculations of the linear accelerator's performance indicated an average beam current of at least 6.25 µA, providing a dose rate of 115 Gy/s at isocenter, high enough for cognition-sparing FLASH effects. The electron plan was less homogenous with a homogeneity index of 0.133 compared to the photon plan's index of 0.087. Overall, the dosimetric characteristics of the 40-MeV electron plan were suitable for treatment. In conclusion, Monte Carlo simulations performed in this work indicate that two lateral opposing 40-MeV electron beams can be used for pediatric whole brain irradiation at FLASH dose rates of >115 Gy/s and serve as motivation for a practical clinical FLASH radiotherapy system, which can be implemented in the near future.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Microbiome dynamics in the congregate environment of U.S. Army Infantry training

Within military training and operational environments, individuals from diverse backgrounds share common spaces, follow structured routines and diets, and engage in physically demanding tasks. While there has been interest in leveraging microbiome features to predict and improve military health and performance, the longitudinal convergence of microbiomes in such constrained environments has not been established. To assess the degree of microbiome convergence, we performed shotgun metagenomic sequencing on swab samples from a military trainee cohort. Samples were taken across four different body sites, three timepoints, and two spatially distinct platoons. We observed evidence of convergence in one platoon, whereby similarity in microbiome composition increased over time, with numerous differentially abundant species. We found no indication of strain transfer between individuals, suggesting that convergence was influenced by external environmental factors, diet, and lifestyle. Microbial shifts observed in the convergence process included a decrease in fungal species, such as Malassezia restricta in nasal cavities, and a decrease in Prevotella species at inguinal regions across time. Shifts in multiple Corynebacterium species were also observed with varying magnitudes depending on the body site. Overall, we provide preliminary evidence of convergence of host microbial communities in military-associated environments that were distinguishable using shotgun metagenomic sequencing approaches. The data presented here on microbiome convergence, dynamics, and stability may inform risk-based mitigation in congregate military settings facilitating development of targeted microbial, dietary, or other interventions to optimize health and performance of military populations.

Biological and medical sciences↗

Bayesian optimization to design a novel x-ray shaping device

In radiation therapy, x-ray dose must be precisely sculpted to the tumor, while simultaneously avoiding surrounding organs at risk. This requires modulation of x-ray intensity in space and/or time. Typically, this is achieved using a multi leaf collimator (MLC) - a complex mechatronic device comprising over one hundred individually powered tungsten ‘leaves’ that move in or out of the radiation field as required. Here, an all-electronic x-ray collimation concept with no moving parts is presented, termed “SPHINX”: Scanning Pencil-beam High-speed Intensity-modulated X-ray source. SPHINX utilizes a spatially distributed bremsstrahlung target and collimator array in conjunction with magnetic scanning of a high energy electron beam to generate a plurality of small x-ray “beamlets.” A simulation framework was developed in Topas Monte Carlo incorporating a phase space electron source, transport through user defined magnetic fields, bremsstrahlung x-ray production, transport through a SPHINX collimator, and dose in water. This framework was completely parametric, meaning a simulation could be built and run for any supplied geometric parameters. This functionality was coupled with Bayesian optimization to find the best parameter set based on an objective function which included terms to maximize dose rate for a user defined beamlet width while constraining inter-channel cross talk and electron contamination. Designs for beamlet widths of 5, 7, and 10 mm 2 were generated. Each optimization was run for 300 iterations and took approximately 40 h on a 24-core computer. For the optimized 7-mm model, a simulation of all beamlets in water was carried out including a linear scanning magnet calibration simulation. Finally, a back-of-envelope dose rate formalism was developed and used to estimate dose rate under various conditions. The optimized 5–, 7–, and 10-mm models had beamlet widths of 5.1 , 7.2 , and 10.1 mm 2 and dose rates of 3574, 6351, and 10 015 Gy/C, respectively. The reduction in dose rate for smaller beamlet widths is a result of both increased collimation and source occlusion. For the simulation of all beamlets in water, the scanning magnet calibration reduced the offset between the collimator channels and beam centroids from 2.9 ±1.9 mm to 0.01 ±0.03 mm. A slight reduction in dose rate of approximately 2% per degree of scanning angle was observed. Based on a back-of-envelope dose rate formalism, SPHINX in conjunction with next-generation linear accelerators has the potential to achieve substantially higher dose rates than conventional MLC-based delivery, with delivery of an intensity modulated 100 x 100 mm 2 field achievable in 0.9 to 10.6 s depending on the beamlet widths used. Bayesian optimization was coupled with Monte Carlo modeling to generate SPHINX geometries for various beamlet widths. A complete Monte Carlo simulation for one of these designs was developed, including electron beam transport of all beamlets through scanning magnets, x-ray production and collimation, and dose in water. These results demonstrate that SPHINX is a promising candidate for sculpting radiation dose with no moving parts, and has the potential to vastly improve both the speed and robustness of radiotherapy delivery. A multi-beam SPHINX system may be a candidate for delivering magavoltage FLASH RT in humans.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

First Time-Resolved Leader Spectra Associated With a Downward Terrestrial Gamma-Ray Flash Detected at the Telescope Array Surface Detector

Optical emissions associated with Terrestrial Gamma ray Flashes (TGFs) have recently become important subjects in space-based and ground-based observations as they can help us understand how TGFs are produced during thunderstorms. In this paper, we present the first time-resolved leader spectra of the optical component associated with a downward TGF. The TGF was observed by the Telescope Array Surface Detector (TASD) simultaneously with other lightning detectors, including a Lightning Mapping Array (LMA), an INTerFerometer (INTF), a Fast Antenna (FA), and a spectroscopic system. The spectroscopic system recorded leader spectra at 29,900 frames per second (33.44 μs time resolution), covering a spectral range from 400 to 900 nm, with 2.1 nm per pixel. The recordings of the leader spectra began 11.7 ms before the -18 kA return stroke and at a height of 2.37 km above the ground. These spectra reveal that optical emissions of singly ionized nitrogen and oxygen occur between 167 μs before and 267 μs after the TGF detection, while optical emissions of neutrals (H I, 656 nm; N I, 744 nm, and O I, 777 nm) occur right at the moment of the detection. The time-dependent spectra reveal differences in the optical emissions of lightning leaders with and without downward TGFs.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Frequentist cosmological constraints from full-shape clustering measurements in DESI DR1

We present a frequentist analysis of clustering measurements from Data Release 1 of the Dark Energy Spectroscopic Instrument (DESI) using the standard profile likelihood method. While Bayesian inferences for effective field theory models of galaxy clustering can be highly sensitive to prior choices for extended cosmological models, frequentist inferences are not susceptible to such effects. We compare frequentist and Bayesian constraints for the parameter set {σ 8 , H 0 , Ω m , w 0 , w a } using the full-shape power spectrum multipoles, post-reconstruction baryon acoustic oscillation (BAO) measurements, and external datasets from the CMB and type Ia supernovae measurements. The frequentist confidence intervals are significantly shifted relative to the Bayesian credible intervals for the w 0 w a CDM model, unless supernovae data are included. When DESI full-shape and BAO data are fit jointly, we obtain the following 1σ frequentist confidence intervals for ΛCDM (w 0 w a CDM): σ 8 = 0.863 +0.048 -0.040 , H 0 = 68.96 +0.81 -0.80 km s -1 Mpc -1 , Ω m = 0.3034 ± 0.0110 (σ 8 = 0.782 +0.060 -0.036 , H 0 = 63.7 +4.2 -2.0 km s -1 Mpc -1 , Ω m = 0.378 +0.024 -0.047 , w 0 = -0.16 +0.10 -0.50 , w a = -3.0 +1.7 ), corresponding to 0.8σ, 0.3σ, 0.7σ (2.1σ, 4.1σ, 6.5σ, 6.3σ, 6.6σ) shifts between the maximum likelihood estimate and the Bayesian posterior mean for ΛCDM (w 0 w a CDM) respectively.

Bayesian reasoning↗

Fiducial-cosmology-dependent systematics for the DESI 2024 full-shape analysis

We assess the impact of the fiducial cosmology choice on cosmological inference from full-shape (FS) fits of the galaxy power spectrum in the DESI 2024 Data Release 1 (DR1). Using a suite of AbacusSummit DR1 mock catalogues based on the Planck 2018 best-fit cosmology, we quantify potential systematic shifts introduced by analysing the data under five secondary cosmologies — featuring variations in matter density, thawing dark energy, higher effective number of neutrino species, reduced clustering amplitude, and the DESI DR1 BAO best-fit w 0 w a CDM cosmology — relative to DESI's baseline Planck 2018 cosmology. We investigate two complementary FS analysis approaches: full-modelling (FM) and ShapeFit (SF), each with distinct sensitivities to the assumed fiducial model. Across all tracers, we find for FM that systematic shifts induced by fiducial cosmology mismatches remain well below the DESI DR1 statistical uncertainties, with maximum deviations of 0.22σ DR1 in ΛCDM scenarios and 0.12σ DR1+SN when including SN Ia mock data in extended w 0 w a CDM fits. For SF, the shifts in the compressed parameters remain below 0.45σ DR1 for all tracers and cosmologies.

dark energy experiments↗