Search NASA⌕ Search

SEARCH · Search NASA

Results for “Space cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Identifying Regions Favorable for Geothermal Heating and Cooling Storage

Space heating and cooling represents the single largest category of in building energy use for U.S. residential and commercial buildings, with heating representing 61% of residential and 46% commercial energy consumption. Building heating technologies are dominated by natural gas technologies, and are an important opportunity for building electrification to enable a transition to a low CO 2 energy system. FLXenabler study is a joint analysis effort among multiple analysis teams at NREL and focused on examining the role of geothermal heating and cooling (GHC) system with thermal energy storage (TES) providing flexibility. Utilizing information from ResStock the amount of energy consumption associated with heating and cooling by state was calculated. We applied adjusted load shapes to estimate the a maximum grid savings potential of using TES to address building space conditioning. Normalizing grid, fuel, and emissions impacts locations with higher favorability for further study in FLXenabler were identified.

15 GEOTHERMAL ENERGY↗

Staying cool: The development of India's pioneering energy efficiency policy for chillers

Abstract Chillers are the key energy‐consuming piece of equipment in most large space cooling systems. They can account for more than 40% of total energy consumption in any typical commercial building and in specific industrial building installations depending on the product and process. With climate change driving rapidly rising demand for commercial and industrial cooling, especially in emerging economies, energy efficiency policies for chillers are crucial to moderate future electricity demand and thereby minimize greenhouse gas emissions. However, most developing and emerging economies lack energy efficiency policies for this significant and growing cooling equipment sector. India recently announced new energy efficiency policies for chillers, projected to avoid 28 TWh of electricity consumption and 23 million tons of CO 2 emissions cumulatively through 2030. This article presents a case study of the unique challenges and solutions required to design a new energy efficiency policy for chillers in India. First, the energy consumed in chiller systems is sensitive to building occupancy, load changes, seasonal variations, operation and maintenance, and climatic conditions. In order to address these sensitivities, the chiller testing standard in India factors local weather and temperature conditions into energy performance ratings to account for these sensitivities. Further, every large chiller is a customized product, therefore developing a viable policy and implementation process required collaboration with international and national experts in standardization, manufacturers, building consultants, and testing laboratories. This article is categorized under: Energy Efficiency > Economics and Policy Solar Energy: Thermal ‐‐> Climate and Environment

Mukherjee, P. K.↗

The AstroBiology Explorer (ABE) MIDEX Mission: Using Infrared Spectroscopy to Identify Organic Molecules in Space

The AstroBiology Explorer (ABE) mission is one of four selected for Phase A Concept Study in NASA's current call for MIDEX class missions. ABE is a cooled space telescope equipped with spectrographs covering the 2.5-20 micron spectral range. The ABE mission is devoted to the detection and identification of organic and related molecular species in space. ABE is currently under study at NASA's Ames Research Center in collaboration with Ball Aerospace.

Sandford, S. A.↗

The development of a solar residential heating and cooling system

The MSFC solar heating and cooling facility was assembled to demonstrate the engineering feasibility of utilizing solar energy for heating and cooling buildings, to provide an engineering evaluation of the total system and the key subsystems, and to investigate areas of possible improvement in design and efficiency. The basic solar heating and cooling system utilizes a flat plate solar energy collector, a large water tank for thermal energy storage, heat exchangers for space heating, and an absorption cycle air conditioner for space cooling. A complete description of all systems is given. Development activities for this test system included assembly, checkout, operation, modification, and data analysis, all of which are discussed. Selected data analyses for the first 15 weeks of testing are included, findings associated with energy storage and the energy storage system are outlined, and conclusions resulting from test findings are provided. An evaluation of the data for summer operation indicates that the current system is capable of supplying an average of 50 percent of the thermal energy required to drive the air conditioner. Preliminary evaluation of data collected for operation in the heating mode during the winter indicates that nearly 100 percent of the thermal energy required for heating can be supplied by the system.

Source record↗

Performance Analysis of a Membrane-based Ionic Liquid Desiccant (ILD) Dehumidifier

Air dehumidification through cooling is an energy-intensive process, which consumes about 20-40% of the overall energy for air-conditioning. Liquid desiccant dehumidification can separate dehumidification from space cooling and has potential to improve the cooling efficiency and reduce the overall energy consumption for air-conditioning. However, the drawbacks such as liquid carryover and corrosion, membrane contamination and blocking, limit its application. To eliminate these problems, a new dehumidifier using nonporous membrane and ionic liquid desiccant (ILD) was developed. The dehumidification performance of the new dehumidifier was characterized through a series of lab tests. Test results indicate that the new dehumidifier can achieve a moisture removal rate up to 180.3 g/h and a dehumidification effectiveness up to 12.7%. A parametric study found that the dehumidification performance is sensitive to the flowrates of the air and the ILD solution. A higher mass flow ratio between the ILD solution and the air could result in better dehumidification performance.

Wang, Lingshi↗

Resilient cooling strategies – A critical review and qualitative assessment

The global effects of climate change will increase the frequency and intensity of extreme events such as heatwaves and power outages, which have consequences for buildings and their cooling systems. Buildings and their cooling systems should be designed and operated to be resilient under such events to protect occupants from potentially dangerous indoor thermal conditions. This study performed a critical review on the state-of-the-art of cooling strategies, with special attention to their performance under heatwaves and power outages. We proposed a definition of resilient cooling and described four criteria for resilience—absorptive capacity, adaptive capacity, restorative capacity, and recovery speed —and used them to qualitatively evaluate the resilience of each strategy. The literature review and qualitative analyses show that to attain resilient cooling, the four resilience criteria should be considered in the design phase of a building or during the planning of retrofits. The building and relevant cooling system characteristics should be considered simultaneously to withstand extreme events. A combination of strategies with different resilience capacities, such as a passive envelope strategy coupled with a low-energy space-cooling solution, may be needed to obtain resilient cooling. Finally, a further direction for a quantitative assessment approach has been pointed out.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Feasibility Analysis for the Use of Retrofitted Air-Conditioners Using Thermal Energy Storage (TES) for High Ambient Temperature (HAT) Countries

In high ambient temperature (HAT) countries, summer temperatures exceed 35℃, degrading the performance of air-conditioning systems and straining power grids. In this paper, a feasibility analysis was conducted to investigate potential savings during the peak using latent Thermal Energy Storage (TES) at near room phase-change temperatures, replacing condensers, thus, minimizing temperature lifts. Weather data, building loads, and baseline air-conditioning systems data were gathered for Dubai. A transient vapor-compression model in Modelica was used to compare the COP, total power input and cooling capacity of the air-conditioner at peak hours when ambient temperatures range between 35 – 45 ⁰C versus the TES-Phase-Change Material (PCM) melting temperatures from 22 – 28⁰C. The results indicate that the TES-PCM can enhance the system COP at the peak by a factor 1.4 and 2 for during for outdoor temperatures of 35 – 40⁰C, and 40 – 45⁰C, respectively. Lower melting temperature PCMs were able to reduce the required power input by 30-50%, with more savings occurring at higher temperature days. On the other hand, higher temperature PCMs enhancements were minimal especially at outdoor ambient temperatures ranging between 35 – 40⁰C. Improvements to the cooling capacity range from 8 – 18 % for the outdoor temperature range of 35 – 45 ⁰C. An economic analysis was conducted to find the potential saving in utility costs for 30%, 60%, and 90% of the space cooling demands of Dubai, and find the trade-off points between utility savings and cost of PCM-TES implementation. If the peak loads are to be shifted by 6 hours daily, the percentage utility savings for the city is 18%. Using estimated costs of the PCM-TES, ranging from $200-500/kWh, the daily load shifting hours were estimated to range from 4 hours at the lowest cost systems to 2.5 hours at the highest costs.

25 ENERGY STORAGE↗

Subcontracted activities related to TES for building heating and cooling

The subcontract program elements related to thermal energy storage for building heating and cooling systems are outlined. The following factors are included: subcontracts in the utility load management application area; life and stability testing of packaged low cost energy storage materials; and development of thermal energy storage systems for residential space cooling. Resistance storage heater component development, demonstration of storage heater systems for residential applications, and simulation and evaluation of latent heat thermal energy storage (heat pump systems) are also discussed. Application of thermal energy storage for solar application and twin cities district heating are covered including an application analysis and technology assessment of thermal energy storage.

Martin, J.↗

BASG thermomechanical pump helium 2 transfer tests

The purpose of the effort described was to perform experiments and calculations related to using a thermomechanical pump in the space-based resupply of the Space Infrared Telescope Facility (SIRTF) with Helium 2. Thermomechanical (fountain effect) pumps have long been suggested as a means for pumping large quantities of Helium 2. The unique properties of Helium 2 have made it useful for cooling space instruments. Several space science missions, including SIRTF, are now being planned which would benefit greatly from on-orbit resupply of Helium 2. A series of experiments were performed to demonstrate that large volumes of Helium 2 can be transferred with a thermomechanical pump at high flow rates and at high efficiency from one dewar to another through valves and lines that are similar to the plumbing arrangement that would be necessary to accomplish such a transfer on-orbit. In addition, temperature, pressure, and flow rate data taken during the tests were used to verify and refine a computer model which was developed.

Mills, G. L.↗

Self-driven cooling loop for a large superconducting magnet in space

Pressurized cooling loops in which superfluid helium circulation is driven by the heat being removed have been previously demonstrated in laboratory tests. A simpler and lighter version which eliminates a heat exchanger by mixing the returning fluid directly with the superfluid helium bath was analyzed. A carefully designed flow restriction must be used to prevent boiling in this low-pressure system. A candidate design for Astromag is shown that can keep the magnet below 2.0 K during magnet charging. This gives a greater margin against accidental quench than approaches that allow the coolant to warm above the lambda point. A detailed analysis of one candidate design is presented.

Mord, A. J.↗

Photoinjector Generation of High-Charge Magnetized Beams for Electron-Cooling Applications

The recently announced Electron-Ion Collider (EIC), to be built at Brookhaven National Laboratory, will collide high-energy ion-beams and electron beams to pursue nuclear physics research on quark-gluon plasma's. The facility performances (luminosity) would be improved if the ion-beam emittance degradation is mitigated via a phase-space-cooling technique. One potential cooling method uses a bright electron beam to cool the ion beams. The cooling rate for this electron-cooling method depends on the transverse emittance of the cooling electron beam and could benefit from using a beam with significant canonical angular momentum dubbed as a magnetized beam. This research focuses on simulation and experimental generation and characterization of high charge magnetized electron beams with parameters comparable to those required for electron cooling at an electron-ion collider. The experiment uses the 50-MeV photo-injector available at the Fermilab Accelerator Science and Technology (FAST) Facility. The measurements are benchmarked against simulations.

43 PARTICLE ACCELERATORS↗

Solar energy system performance evaluation report for Solaron-Duffield, Duffield, Virginia

The Solaron Duffield Solar Energy System was designed to provide 51 percent of the space heating, and 49 percent of the domestic hot water (DHW) to a two story 1940 square foot area residence using air as the transport medium. The system consists of a 429 square foot collector array, a 265 cubic foot rock thermal storage bin, heat exchangers, an 80 gallon DHW preheat tank, pumps, blowers, controls, air ducting and associated plumbing. A air-to-liquid heat pump coupled with a 1,000gallon water storage tank provides for auxiliary space heating and can also be used for space cooling. A 52 gallon electric DHW tank using the solar preheated water provides domestic hot water to the residence. The solar system, which became operational July 1979, has the following modes of operation: First Stage: (1) collector to storage and DHW; (2)collector to space heating; (3) storage to load. Second Stage: (4) heat pump auxiliary direct; (5) auxiliary heat from heat pump storage. Third Stage: (6) electrical resistance (strip) heat.

Source record↗

The "Very Cool" James Webb Space Telescope!

For over twenty years, scientists, engineers, technicians, and other personnel have been working on the next generation space telescope. As a partnership between NASA (National Aeronautics and Space Administration), CSA (Canadian Space Agency), and ESA (European Space Angency), the James Webb Space Telescope will complement the previous research performed by the Hubble by utilizing a larger primary mirror, which will also be optimized for infrared wavelengths. This combination will allow JWST to collect data and take images of light having traveled over 13.7 billion light years. This presentation will focus on the mission, as well as the contamination control challenges during the integration and testing in the NASA Goddard Spacecraft Systems Development and Integration Facility (SSDIF), one of the largest cleanrooms in the world. Additional information will be presented regarding space simulation testing down to a cool 20 degrees Kelvin [-424 degrees Fahrenheit] that will occur at Johnson Space Center in Houston, TX, and more testing and integration to happen at Northrop Grumman Corp., in Redondo Beach, CA. Launch of the JWST is currently scheduled for the spring of 2019 at Ariane Spaceport in French Guiana, South America.

space sciences↗

Internally cooled membrane-based absorber for dehumidification and water heating: Validated model and simulation study

This report presents a comprehensive model for advanced membrane-based absorber components accounting for three separate fluid streams, one of them providing internal cooling, with complex flow patterns. The model was implemented with various liquid desiccants and their properties (including LiCl, CaCl 2 , and [emim][OMS] ionic liquid [IL]). The model has been validated using data from two laboratory prototype absorbers, one with CaCl 2 as the working fluid and one with an IL as the working fluid. Entropy analysis was further carried out to verify the model and understand effect of internal cooling on the entropy variation of three fluid streams. The developed model and codes are expected to enable detailed configuration optimization and provide in-depth understanding of three-fluid heat and mass exchanger (HMX) performance. The paper also describes parametric studies of the HMX components in utilizing the latent heat removed in space cooling to heat water and numerically explores the unique benefit of its application in a semi-open absorption heat pump water heater. The results show that a single three-fluid HMX has the potential to achieve simultaneous dehumidification and water heating efficiently at cost effectiveness, particularly in hot and humid climates.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Zero-g experiments with a He II active phase separator for space application

An active phase separator (APS) for temperature control of He II space cooling systems was tested in a zero-g environment during a series of parabolic flights on a NASA KC 135 aircraft. The APS provides for liquid-gas separation and features an annular gap, a downstream heat exchanger and an upstream ball closure. The apparatus was operated during acceleration and floating and in two different heat load situations. The tests confirmed that adequate mass flow rates could be maintained using a vacuum pump to simulate space vacuum and that residual liquid could be evaporated from the heat exchanger after closing a ball valve to seal off flows.

Denner, H. D.↗

Novel Modular Residential CCHP for Space Conditioning and Water Heating

This presentation will first describe the design of a novel modular residential cold-climate heat pump for both space conditioning and water heating that can be coupled with thermal energy storage (TES) to maximize system efficiency and load flexibility. Among some of the novel operating modes of the proposed design include: 1) simultaneous outdoor coil defrost while still providing space heating or water heating; 2) simultaneous water heating and space cooling 3) using the TES as the heat source during cold climate operation to improve efficiency and 4) compressorless charging of the TES module during days with high temperature swings between night and day. Then, initial simulation results will be presented describing system performance in key operating modes in climate region 5.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Towards COP27: Decarbonization patterns of residential building in China and India

As the two largest emerging emitters with the highest growth in operational carbon emissions from residential buildings, the historical emission patterns and decarbonization efforts of China and India warrant further exploration. This study aims to be the first to present a carbon intensity model considering end-use performances, assessing the operational decarbonization progress of residential building in India and China over the past two decades using the newest decomposing structural decomposition approach. Results indicate (1) the annual operational carbon intensity increased by 1.4% and 2.5% in China and India, respectively, between 2000 and 2020. Household expenditure-related energy intensity and emission factors were crucial in decarbonizing residential buildings. (2) Building electrification played a significant role in decarbonizing space cooling (–87.7 in China and – 130.2 kg of carbon dioxide (kgCO 2 ) per household in India) and appliances (~ –169.7 in China and ~ –43.4 kgCO 2 per household in India). (3) China and India collectively decarbonized 1498.3 and 399.7 M-tons of CO 2 in residential building operations, respectively. In terms of decarbonization intensity, India (164.8 kgCO 2 per household) nearly caught up with China (182.5 kgCO 2 per household) in 2020 and is expected to surpass China in the upcoming years, given the country's robust annual growth rate of 7.3%. Overall, this study provides an effective data-driven tool for investigating the building decarbonization potential in China and India, and offers valuable insights for other emerging economies seeking to decarbonize residential buildings in the forthcoming COP28 1 age.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗