Search NASA⌕ Search

SEARCH · Search NASA

Results for “Spectral linewidths”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

88 records · Page 5

Observations of Low-degree Modes from the Solar Maximum Mission (extended Abstract)

Mean frequencies, amplitudes, and linewidths for the solar 5 min p mode oscillations of degree 0, 1, and 2 have been obtained from approx. 280 days of SMM-ACRIM total irradiance data. The frequencies are in good agreement with measurements obtained from velocity data. The amplitudes of the modes lie along a well defined envelope of power vs. frequency, which peaks at 3.1 mHz and has a width of 0.7 mHz (FWHM). The r.m.s. amplitude of the highest peak in the spectrum (n=21, l=1) is approx. 3 ppm of the total flux. The linewidths of the narrowest l=O modes are approx. 1 micro Hz (FWHM). A broad continuum of power caused both by solar surface granulation and by instrumental noise interferes with the analysis of 5 min modes. The continuum spectral power in a 1 micro Hz band near 3 mHz corresponds to an apparent r.m.s. variation of approx. 0.5 parts per million of the mean solar flux.

Woodard, M.↗

Semiconductor Reference Oscillator Development for Coherent Detection Optical Remote Sensing Applications

The NASA Earth Science Enterprise Advanced Technology Initiatives Program is supporting a program for the development of semiconductor laser reference oscillators for application to coherent optical remote sensing from Earth orbit. Local oscillators provide the frequency reference required for active spaceborne optical remote sensing concepts that involve heterodyne (coherent) detection. Two recent examples of such schemes are Doppler wind lidar and tropospheric carbon dioxide measurement by laser absorption spectrometry, both of which are being proposed at a wavelength of 2.05 microns. Frequency-agile local oscillator technology is important to such applications because of the need to compensate for large platform-induced Doppler components that would otherwise interfere with data interpretation. Development of frequency-agile local oscillator approaches has heretofore utilized the same laser material as the transmitter laser (Tm,Ho:YLF in the case of the 2.05-micron wavelength mentioned above). However, a semiconductor laser-based frequency-agile local oscillator offers considerable scope for reduced mechanical complexity and improved frequency agility over equivalent crystal laser devices, while their potentially faster tuning capability suggest the potential for greater scanning versatility. The program we report on here is specifically tasked with the development of prototype novel architecture semiconductor lasers with the power, tunability, and spectral characteristics required for coherent Doppler lidar. The baseline approach for this work is the distributed feedback (DFB) laser, in which gratings are etched into the semiconductor waveguide structures along the entire length of the laser cavity. However, typical DFB lasers at the wavelength of interest have linewidths that exhibit unacceptable growth when driven at the high currents and powers that are required for the Doppler lidar application. Suppression of this behavior by means of corrugation pitch-modulation (using a detuned central section to prevent intensity peaking in the center of the cavity) is currently under investigation to achieve the required performance goals.

distributed feedback (DFB) laser↗

Submillimeter heterodyne spectroscopy and remote sensing of the upper atmosphere

Submillimeter-wavelength heterodyne spectroscopy by microwave limb sounding (MLS) from orbiting satellite is a measurement technique for studying Earth's stratosphere, mesosphere and lowerr thermosphere on a global scale. Development and deployment of such tools are timely, as stratospheric ozone shileds life from solar ultraviolet radiation but is depleted by pollution from industrial activities. MLS experiments on NASA's Upper Atmosphere Research Satellite (UARS) and Earth Observing System (EOS) are now being developed and implementend for global monitoring. Atmospheric thermal-emission spectra at millimeter and submillimeter wave-lengths are measured as the instrument field of view (FOV) is scanned through the limb from above. Atmospheric profiles of molecular abundances, temperature, pressure, wind and magnetic field can be determined from the measured emission spectra. Intensity of the emission can provide abundance and temperature. Measured linewidths, and emission from temperature-insensitive O2 lines, can provide pressure. Differentitaion of measured pressure with repsect ot measured height differential (obtaiend from the instrument FOV scan encoder) can also provide temperature through atmospheric hydrostatic equilibrium (which relates temperature to pressure and height differential). Doppler shifts of spectral lines can provide wind, and Zeeman splitting of the magnetic-dipole lines of O2 can provide magnetic field.

Waters, J. W.↗

30 Hz-linewidth, diode-laser-pumped, Nd:GGG nonplanar ring oscillators by active frequency stabilisation

A heterodyne linewidth of less than 30 Hz for the beatnote between the outputs of two 282 THz Nd:GGG nonplanar ring oscillators (NPROs) is reported. The lasers were independently locked to adjacent axial modes of a high-finesse interferometer. The remnant frequency noise appears to be dominated by free spectral range fluctuations in the reference interferometer rather than by residual laser noise.

Day, T.↗

Differential absorption lidar measurements of atmospheric water vapor using a pseudonoise code modulated AlGaAs laser

Lidar measurements using pseudonoise code modulated AlGaAs lasers are reported. Horizontal path lidar measurements were made at night to terrestrial targets at ranges of 5 and 13 km with 35 mW of average power and integration times of one second. Cloud and aerosol lidar measurements were made to thin cirrus clouds at 13 km altitude with Rayleigh (molecular) backscatter evident up to 9 km. Average transmitter power was 35 mW and measurement integration time was 20 minutes. An AlGaAs laser was used to characterize spectral properties of water vapor absorption lines at 811.617, 816.024, and 815.769 nm in a multipass absorption cell using derivative spectroscopy techniques. Frequency locking of an AlGaAs laser to a water vapor absorption line was achieved with a laser center frequency stability measured to better than one-fifth of the water vapor Doppler linewidth over several minutes. Differential absorption lidar measurements of atmospheric water vapor were made in both integrated path and range-resolved modes using an externally modulated AlGaAs laser. Mean water vapor number density was estimated from both integrated path and range-resolved DIAL measurements and agreed with measured humidity values to within 6.5 percent and 20 percent, respectively. Error sources were identified and their effects on estimates of water vapor number density calculated.

Rall, Jonathan A. R.↗

Highly coherent long cavity GaAs/AlGaAs single-quantum-well lasers

The spectral properties of ridge-waveguide graded-index separate-confinement heterostructure single-quantum-well (SQW) GaAs/AlGaAs lasers are measured. Long-cavity lasers (800 microns) exhibit remarkably pure CW single-longitudinal-mode spectra in spite of the short cavity mode spacing. At output power 5 mW, the sidemode suppression exceeds 24 dB and the linewidth is 1.5 MHz. The linewidth-power product (LPP) is 6.4 MHz mW. Measurements of LPP as a function of cavity length L gives a 1/L-squared dependence, in agreement with theory. The results are used to deduce the linewidth enhancement factor alpha at the gain peak wavelength and its dependence on the excitation level. The sublinear gain-carrier density relation in the SQW results in an increase in alpha with increasing carrier density (decreasing cavity length). A decrease in alpha was observed for lasers operating at the second quantized state due to a recovery of the differential gain.

Larsson, Anders↗

Alexandrite laser transmitter development for airborne water vapor DIAL measurements

In the DIAL technique, the water vapor concentration profile is determined by analyzing the lidar backscatter signals for laser wavelengths tuned 'on' and 'off' a water vapor absorption line. Desired characteristics of the on-line transmitted laser beam include: pulse energy greater than or equal to 100 mJ, high-resolution tuning capability (uncertainty less than 0.25 pm), good spectral stability (jitter less than 0.5 pm about the mean), and high spectral purity (greater than 99 percent). The off-line laser is generally detuned less than 100 pm away from the water vapor line. Its spectral requirements are much less stringent. In our past research, we developed and demonstrated the airborne DIAL technique for water vapor measurements in the 720-nm spectral region using a system based on an alexandrite laser as the transmitter for the on-line wavelength and a Nd:YAG laser-pumped dye laser for the off-line wavelength. This off-line laser has been replaced by a second alexandrite laser. Diode lasers are used to injection seed both lasers for frequency and linewidth control. This eliminates the need for the two intracavity etalons utilized in our previous alexandrite laser and thereby greatly reduces the risk of optical damage. Consequently, the transmitted pulse energy can be substantially increased, resulting in greater measurement range, higher data density, and increased measurement precision. In this paper, we describe the diode injection seed source, the two alexandrite lasers, and the device used to line lock the on-line seed source to the water vapor absorption feature.

Chyba, Thomas H.↗

Effective gain measurements in chromium-doped forsterite

Effective gain cross section in tetravalent chromium-doped forsterite laser crystal was measured over the 1180-1330 nm spectral range. The experiment was performed using two collinear laser beams in a pump-and-probe arrangement. The peak-gain cross section from this measurement is estimated to be 1.9 x 10 to the -19th sq cm at 1215 nm, which is comparable to the value of about 2 x 10 to the -19th sq cm predicted by fluorescence linewidth and lifetime measurements. These results indicate that excited-state absorption is not a major loss mechanism in tetravalent chromium-doped forsterite.

Petricevic, V.↗

Theoretical and experimental analysis of injection seeding a Q-switched alexandrite laser

Injection seeding is a method for achieving linewidths of less than 500 MHz in the output of broadband, tunable, solid state lasers. Dye lasers, CW and pulsed diode lasers, and other solid state lasers have been used as injection seeders. By optimizing the fundamental laser parameters of pump energy, Q-switched pulse build-up time, injection seed power and mode matching, one can achieve significant improvements in the spectral purity of the Q-switched output. These parameters are incorporated into a simple model for analyzing spectral purity and pulse build-up processes in a Q-switched, injection-seeded laser. Experiments to optimize the relevant parameters of an alexandrite laser show good agreement.

Prasad, C. R.↗

Shifts of the spectral lines of He(+) produced by electron collisions

The shifts of the Ly-alpha, Ly-beta, and H-alpha lines of He(+) in a plasma, produced by electron scattering from radiating ions are calculated. Electron densities in the neighborhood of 10 to the 17th/cu cm and plasma temperatures from 1 to 6 eV are considered. The calculation is made in the impact approximation, and is based on a six-state close-coupling computation of the scattering matrices, into which an optical potential has been inserted. Small red shifts of the lines are obtained. The contribution of electron scattering to the linewidths is also considered.

Unnikrishnan, K.↗

Current status of quantitative rotational spectroscopy for atmospheric research

Remote sensing of rotational transitions in the Earth's atmosphere has become an important method for the retrieval of geophysical temperatures, pressures and chemical composition profiles that requires accurate spectral information. This paper highlights the current status of rotational data that are useful for atmospheric measurements, with a discussion of the types the rotational lineshape measurements that are not generally available in either online repository.

limb sounding↗

Quantitative PLIF Imaging in High-Pressure Combustion

This is the final report for a research project aimed at developing planar laser-induced fluorescence (PLIF) techniques for quantitative 2-D species imaging in fuel-lean, high-pressure combustion gases, relevant to modem aircraft gas turbine combustors. The program involved both theory and experiment. The theoretical activity led to spectroscopic models that allow calculation of the laser-induced fluorescence produced in OH, NO and 02 for arbitrary excitation wavelength, pressure, temperature, gas mixture and laser linewidth. These spectroscopic models incorporate new information on line- broadening, energy transfer and electronic quench rates. Extensive calculations have been made with these models in order to identify optimum excitation strategies, particularly for detecting low levels (ppm) of NO in the presence of large 02 mole fractions (10% is typical for the fuel-lean combustion of interest). A promising new measurement concept has emerged from these calculations, namely that excitation at specific wavelengths, together with detection of fluorescence in multiple spectral bands, promises to enable simultaneous detection of both NO (at ppm levels) and 02 or possibly NO, 02 and temperature. Calculations have been made to evaluate the expected performance of such a diagnostic for a variety of conditions and choices of excitation and detection wavelengths. The experimental effort began with assembly of a new high-pressure combustor to provide controlled high-temperature and high-pressure combustion products. The non-premixed burner enables access to postflame gases at high temperatures (to 2000 K) and high pressures (to 13 atm), and a range of fuel-air equivalence ratios. The chamber also allowed use of a sampling probe, for chemiluminescent detection of NO/NO2, and thermocouples for measurement of gas temperature. Experiments were conducted to confirm the spectroscopic models for OH, NO and 02.

Hanson, R. K.↗

Low SWaP Semiconductor Laser Transmitter Modules For ASCENDS Mission Applications

The National Research Council's (NRC) Decadal Survey (DS) of Earth Science and Applications from Space has identified the Active Sensing of CO2 Emissions over Nights, Days, and Seasons (ASCENDS) as an important atmospheric science mission. NASA Langley Research Center, working with its partners, is developing fiber laser architecture based intensity modulated CW laser absorption spectrometer for measuring XCO2 in the 1571 nm spectral band. In support of this measurement, remote sensing of O2 in the 1260 nm spectral band for surface pressure measurements is also being developed. In this paper, we will present recent progress made in the development of advanced transmitter modules for CO2 and O2 sensing. Advanced DFB seed laser modules incorporating low-noise variable laser bias current supply and low-noise variable temperature control circuit have been developed. The 1571 nm modules operate at >80 mW and could be tuned continuously over the wavelength range of 1569-1574nm at a rate of 2 pm/mV. Fine tuning was demonstrated by adjusting the laser drive at a rate of 0.7 pm/mV. Heterodyne linewidth measurements have been performed showing linewidth ~200 kHz and frequency jitter ~75 MHz. In the case of 1260 nm DFB laser modules, we have shown continuous tuning over a range of 1261.4 - 1262.6 nm by changing chip operating temperature and 1261.0 - 1262.0 nm by changing the laser diode drive level. In addition, we have created a new laser package configuration which has been shown to improve the TEC coefficient of performance by a factor of 5 and improved the overall efficiency of the laser module by a factor of 2.

Prasad, Narasimha S.↗

Generation of Optical Combs in a WGM Resonator from a Bichromatic Pump

Optical combs generated by a monolithic resonator with Kerrmedium can be used in a number of applications, including orbital clocks and frequency standards of extremely high accuracy, such as astronomy, molecular spectroscopy, and the like. The main difficulty of this approach is the relatively high pump power that has to be used in such devices, causing undesired thermorefractive effects, as well as stimulated Raman scattering, and limiting the optical comb quality and utility. In order to overcome this problem, this innovation uses a different approach to excitation of the nonlinear oscillations in a Kerr-nonlinear whispering gallery mode (WGM) resonator and generation of the optical comb. By coupling to the resonator two optical pump frequencies instead of just one, the efficiency of the comb source can be increased considerably. It therefore can operate in a lowerpower regime where the undesirable effects are not present. This process does not have a power threshold; therefore, the new optical component can easily be made strong enough to generate further components, making the optical comb spread in a cascade fashion. Additionally, the comb spacing can be made in an arbitrary number of the resonator free spectral ranges (FSR). The experimental setup for this innovation used a fluorite resonator with OMEGA= 13.56 GHz. This material has very low dispersion at the wavelength of 1.5 microns, so the resonator spectrum around this wavelength is highly equidistant. Light was coupled in and out of the resonator using two optical fibers polished at the optimal coupling angle. The gap between the resonator and the fibers, affecting the light coupling and the resonator loading, was controlled by piezo positioners. The light from the input fiber that did not go into the resonator reflected off of its rim, and was collected by a photodetector. This enabled observation and measurement of the (absorption) spectrum of the resonator. The input fiber combined light from two lasers centered at around 1,560 nanometers. Both laser frequencies were simultaneously scanned around the selected WGMs of the same family. However, they were separated by one, two, three, or ten FSRs. This was achieved by fine-tuning each laser frequency offset until the selected resonances overlap on the oscilloscope screen. The resonator quality factor Q = 7 x 10(exp 7) was relatively low to increase the linewidth and, therefore, the duty cycle of both lasers simultaneously coupled into their WGMs. The optical spectrum analyzer (OSA) connected to the output fiber was continuously acquiring data, asynchronously with the laser scan. The instrument was set to retain the peak power values; therefore, a trace recorded for a sufficiently long period of time reflected the situation with both lasers maximally coupled to the WGMs.

Strekalov, Dmitry V.↗