Properties of Heavy Cosmic Nuclei Phosphorus, Chlorine, Argon, Potassium, and Calcium: Results from the Alpha Magnetic Spectrometer

We report the unique properties of cosmic phosphorus (P), chlorine (Cl), argon (Ar), potassium (K), and calcium (Ca) fluxes in the GV to TV rigidity range collected by the Alpha Magnetic Spectrometer (AMS) on the International Space Station. With a total of one million events collected over 13.5 years, we observed that the rigidity dependencies of the five fluxes are well described by the sums of a primary cosmic ray component and a secondary cosmic ray component. The abundance ratios of all five elements to Si at the source are accurately determined independent of cosmic ray propagation. The source abundance of Ar and Ca (even-𝑍 elements) is larger than P, Cl, and K (odd-𝑍 elements). The secondary components of the P and the Cl fluxes are each ∼1/3 of the F flux, and the secondary components of the Ar, K, and Ca fluxes are each ∼1/2 of the F flux. The twenty elements measured by AMS, from He to Ca and Fe, can be categorized into four classes, two primary and two secondary, based on their rigidity dependence.

cosmic ray acceleration

Longitudinal spin transfer to Λ hyperons in semi-inclusive deep inelastic scattering with the CLAS12 spectrometer

The polarization of Λ hyperons is preserved in the angular distribution of their decay products. This property allows one to study the spin structure of the Λ. In semi-inclusive deep inelastic scattering where a high energy lepton interacts with a nucleon target and one or more hadrons and the scattered lepton are detected in the final state, the probability for a struck quark to impart the polarization of the lepton to the Λ may be measured. In particular, in electron-proton scattering this quantity may be related to the longitudinal light quark polarization of the Λ. Currently, limited experimental data cannot discriminate between different models of Λ spin structure. This work reports on the measurement of the longitudinal spin transfer 𝐷$^{Λ}_{𝐿⁢𝐿′}$ to the Λ using data taken by the CLAS12 spectrometer at Jefferson Lab with a 10.6 GeV longitudinally polarized electron beam and an unpolarized hydrogen target. This measurement is the most precise to date, and, in comparison with theory predictions, it offers valuable insight into the relative dominance of current and target fragmentation in Λ production.

deep inelastic scattering

Reconstruction of beam parameters and betatron radiation spectra measured with a Compton spectrometer

The photon flux resulting from high-energy electron beam interactions with high-field systems, such as those found in the upcoming FACET-II experiments at the SLAC National Accelerator Laboratory, yields deep insight into the electron beam’s underlying dynamics during the interaction. However, extracting this information is an intricate process. To demonstrate how to approach this challenge using modern methods, this paper utilizes simulated data that models plasma wakefield acceleration-derived betatron radiation in experiments to determine reliable methods of reconstructing key beam and beam-plasma interaction properties. For betatron radiation measurements, translating the observed 200⁢ keV to 30⁢ MeV photon double-differential energy-angle spectra obtained from an advanced Compton spectrometer requires testing multiple methods to optimize the pipeline from its response to incident electron beam information. The paper compares maximum likelihood estimation and machine learning to refine the translation of photon spectra into precise electron beam metrics, such as spot size, energy, and emittance, enhancing the understanding of beam behavior within these dense, high-field environments. We also introduce machine learning and the expected maximization algorithm to reconstruct the primary photon spectrum, employing a multilayer neural network for regression analysis of the energy and angle spectra. With appropriate modifications, the advanced methods reproduce relevant incident beam parameters with high accuracy, even for beam sizes in the <10 μ⁢m range. This capacity is critical to understanding intense beam propagation and its optimization in plasma.

Beam code development & simulation techniques

Decay studies of the 𝛽-delayed neutron emitters 87 Br and 88 Br measured by means of the Modular Total Absorption Spectrometer at ORNL HRIBF

The β decays of 87 Br, 88 Br, and 87 Kr were measured with the Modular Total Absorption Spectrometer (MTAS) at Oak Ridge National Laboratory’s Holifield Radioactive Ion Beam Facility (HRIBF). Both bromine isotopes are β-delayed neutron emitters that have large cumulative fission yields and were identified as top-priority cases for total absorption study by the Nuclear Energy Agency in 2007. Our investigations corroborate that the decay schemes of 87 Br and 88 Br suffer from the so-called pandemonium effect. Unique MTAS properties enable direct neutron measurements. Here, we present MTAS-derived β-delayed neutron spectra, β-delayed neutron emission probabilities of P n ( 87 Br) = 2.36(24)%, and P n ( 88 Br) = 6.4(6)%, and the β-delayed neutron transitions intensity of 4(2)% to the first excited 87 Kr state, populated in the β-neutron decay of 88Br. Incorporating new data into calculations of the electromagnetic decay heat component emitted during thermal neutron fission of 235 U and 239 Pu improves agreement with experimental data up to approximately 80 s after fission. The estimation of the nuclear reactor $\bar{ν}_e$ flux results in changes of up to 1% in the expected $\bar{ν}_e$ interactions with the detector material for 235 U, 238 U, 239Pu, and 241 Pu.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

Properties of Cosmic Deuterons Measured by the Alpha Magnetic Spectrometer

Precision measurements by the Alpha Magnetic Spectrometer (AMS) on the International Space Station of the deuteron (𝐷) flux are presented. The measurements are based on 21 × 10 6 𝐷 nuclei in the rigidity range from 1.9 to 21 GV collected from May 2011 to April 2021. We observe that over the entire rigidity range the 𝐷 flux exhibits nearly identical time variations with the 𝑝, 3 He, and 4 He fluxes. Above 4.5 GV, the 𝐷/ 4 He flux ratio is time independent and its rigidity dependence is well described by a single power law ∝𝑅 Δ with Δ 𝐷/ 4 He = −0.108 ± 0.005. This is in contrast with the 3 He/ 4 He flux ratio for which we find Δ 3 He/ 4 He = −0.289 ± 0.003. Above ∼13 GV we find a nearly identical rigidity dependence of the 𝐷 and 𝑝 fluxes with a 𝐷/𝑝 flux ratio of 0.027 ± 0.001. These unexpected observations indicate that cosmic deuterons have a sizable primarylike component. With a method independent of cosmic ray propagation, we obtain the primary component of the 𝐷 flux equal to 9.4 ± 0.5% of the 4 He flux and the secondary component of the 𝐷 flux equal to 58 ± 5% of the 3 He flux.

cosmic ray acceleration

Properties of Cosmic Lithium Isotopes Measured by the Alpha Magnetic Spectrometer

We present the first measurement of cosmic-ray fluxes of 6 Li and 7 Li isotopes in the rigidity range from 1.9 to 25 GV. The measurements are based on 9.7 × 10 5 6 Li and 1.04 × 10 6 7 Li nuclei collected by the Alpha Magnetic Spectrometer on the International Space Station from May 2011 to October 2023. We observe that over the entire rigidity range the 6 Li and 7 Li fluxes exhibit nearly identical time variations and, above ∼4 GV, the time variations of 6 Li , 7 Li , He, Be, B, C, N, and O fluxes are identical. Above ∼7 GV, we find an identical rigidity dependence of the 6 Li and 7 Li fluxes. This shows that they are both produced by collisions of heavier cosmic-ray nuclei with the interstellar medium and, in particular, excludes the existence of a sizable primary component in the 7 Li flux.

cosmic ray acceleration

Single-shot hard X-ray spectrometer with uniform spatial and spectral response

We demonstrate a single-shot hard X-ray spectrometer based on small-angle scattering from glassy carbon that is insensitive to XFEL beam-dependent spatial and spectral variations. Comparison with established X-ray Thomson scattering diagnostics using stochastic correlation X-ray spectroscopy demonstrates full-bandwidth coverage with meV-scale spectral resolution, enabling reliable single-shot spectroscopic measurements.

47 OTHER INSTRUMENTATION

Magnetic Field Mapping Design for the MOLLER Spectrometer Magnets at Jefferson Lab

The Thomas Jefferson National Accelerator Facility (JLab) has developed a unique spectrometer system to study the weak interaction between electrons. The "Measurement of Lepton-Lepton Electroweak Reaction" (MOLLER) experiment, utilizing JLab's recent 12 GeV electron beam upgrade, is scheduled to operate for three years. Central to the MOLLER experiment are five water-cooled toroidal magnets, each with a unique geometry and seven-fold symmetry, designed to focus the particles. These magnets generate the magnetic field needed to separate incident beam electrons scattered from target electrons (Møller scattering) and protons (elastic e-p scattering) within a liquid hydrogen target. Here, this paper details the magnet field measuring technique developed to map all five MOLLER toroidal magnets at multiple locations inside and along the bore. It covers the design, mounting, and operation of the probe, along with the calibration procedure to determine the field and to prepare a field map for GEANT4 analysis. Additionally, the paper addresses the challenges of accurately measuring low magnetic fields.

Ghoshal, Probir K. [Thomas Jefferson National Acce

Initial in-orbit operation of the soft X-ray spectrometer Resolve onboard the X-ray imaging and spectroscopy mission satellite

The X-Ray Imaging and Spectroscopy Mission satellite was launched on September 6, 2023 (UT). Its Resolve instrument is a high-resolution X-ray spectrometer enabled by a microcalorimeter array thermally anchored to a 50-mK heat sink. Many sensitive, critical sub-systems comprise Resolve, including a multistage cryogenic cooling system, thin-film aperture filters, low-noise electronics, on-board signal processing, and several sources of X-rays for calibration. We summarize the initial on-orbit power-on and checkout of Resolve that commenced immediately after launch. Soon after launch, the cryocoolers were activated, and their operation was successfully established. On October 9, 2023, the first cycle of the adiabatic demagnetization refrigerator was carried out, bringing the sensors to their steady-state operational temperatures. Following this, the energy resolution at 5.9 keV was successfully measured. The energy scale of the system is highly sensitive to the thermal environment surrounding both the sensors and their analog electronics. Gain correction was performed using reference X-ray lines from onboard calibration sources. To optimize cooler frequency settings, noise spectra were collected across a range of frequencies, and the most suitable frequency pair was selected based on the in-orbit environment. During the final phase of the checkout, an attempt was made to open the gate valve, which is designed to protect the Dewar’s interior from external pressure during ground operations and launch. Unfortunately, this attempt was unsuccessful. As a result, the checkout process was temporarily paused, and a stable operational strategy was subsequently developed to enable Resolve to function effectively with the gate valve remaining closed.

X-ray micro-calorimeter

Strategies for the in-orbit gain tracking using the modulated X-ray sources for the Resolve microcalorimeter spectrometer on the X-ray Imaging and Spectroscopy Mission

Accurate and precise correction of the gain drift is the key to achieve the required energy resolution of the Resolve microcalorimeter spectrometer on the X-ray Imaging and Spectroscopy Mission (XRISM). Therefore, Resolve is equipped with highly configurable X-ray sources called the modulated X-ray source (MXS). The pulsed nature allows us to separate calibration and astrophysical X-rays by time interval selections. However, undesirable characteristics of the MXS, such as the afterglow X-rays, restrict the allowed configuration range. Moreover, the nonlinear and discontinuous behaviors of the calibration line count rate make the determination of the optimal setting highly complex. The MXS count rate model has been established using measurements in the spacecraft thermal vacuum test with the flight detector and MXS. A trade-off study using the model enables us to choose a few settings for the continuous use of the MXS optimized for different ranges of target gain tracking intervals. An alternative approach, where the MXS is used only intermittently, has also been developed and implemented. This new mode enables us to reconstruct the drift without having most of the undesirable effects in science data. This also forms the basis of the gain tracking under the current Resolve configuration with the closed gate valve.

Astronomy and AstroPhysics

Core line spread function calibration of the X-ray Imaging and Spectroscopy Mission Resolve X-ray calorimeter spectrometer

The Resolve X-ray imaging spectrometer onboard the X-ray Imaging and Spectroscopy Mission consists of a 36 pixel array of high-resolution X-ray calorimeters each with ∼ 5 eV full-width-at-half-maximum (FWHM) spectral resolution in the 0.3 to 12 keV band. The response to monochromatic X-rays (line spread function, LSF) is composed of a narrow Gaussian core and weak extended components caused by energy loss during thermalization. We report on the characterization of the Gaussian core LSF in an extensive ground calibration campaign. We also discuss the characterization of on-orbit resolution, which shows slightly higher FWHM than that obtained on the ground.

Astronomy and AstroPhysics

Ground calibration plan for the Athena/X-IFU microcalorimeter spectrometer

The X-ray Integral Field Unit is the X-ray imaging spectrometer on board one of ESA’s next large missions, Athena. Athena is set to investigate the theme of the Hot and Energetic Universe, with a launch planned in the late-2030s. Based on a high-sensitivity transition edge sensor (TES) detector array operated at very low temperature (50 mK), X-IFU will provide spatially resolved high-resolution spectroscopy of the X-ray sky in the 0.2 to 12 keV energy band, with an energy resolution goal of 4 eV up to 7 keV [3 eV design goal]. This work presents the current calibration plan of the X-IFU. It provides the requirements applicable to the X-IFU calibration, describes the overall calibration strategy, and details the procedure and sources needed for the ground calibration of each parameter or characteristics of the X-IFU.

47 OTHER INSTRUMENTATION

Coupling of high-resolution mass spectrometer and photosynthesis system for comprehensive leaf volatile metabolite profiling

Background Leaf-level biogenic volatile organic compounds (BVOCs) emissions represent a major source of organic gases in the atmosphere, influencing both climate and air quality. These emissions are strongly driven by environmental perturbations, which affect individual plant- to ecosystem-level processes. Uncovering all the BVOCs and understanding how their emissions respond to altered environmental conditions provide critical insights into vegetation-driven changes in atmospheric chemistry. We developed a tandem instrumentation setup that integrates a proton transfer reaction time-of-flight mass spectrometer (PTR-ToF-MS) with parts-per-trillion detection limits and a photosynthetic infrared gas exchange system for the untargeted survey of all the BVOCs. This novel system enables simultaneous, real-time monitoring of BVOC emissions and photosynthetic parameters at the leaf level, offering new opportunities to disentangle the physiological and environmental drivers of VOC release. Furthermore, we established the VOC Analysis and Processing Optimization Resource (VAPOR), an open-access software tool designed for rapid data post-processing and the analysis of the variability of hundreds of BVOCs. We assessed the performance of the tandem system under varying background conditions, using standard gas mixtures and a range of environmental factors. Results Blank emissions were substantially lower for major BVOCs (e.g., isoprene) compared to those observed in plant emissions. Despite this, the observation of background-level VOCs highlights the importance of routinely acquiring and accounting for blank measurements in analyses using the coupled instrumentation. Introduction of known VOC concentrations to the system demonstrated a linear response across different compounds with varying molecular compositions, indicating minimal gas loss regardless of chemical moieties within the coupled instrumentation. We applied the optimized system to investigate the physiological mechanisms driving BVOC emissions across different genotypes of poplar and pennycress. The high mass resolution capabilities of the PTR-ToF-MS, coupled with comprehensive VAPOR-driven data analysis, enabled the identification of several important BVOCs, including methanol and methanethiol; these BVOCs displayed substantial variation across pennycress genotypes and showed concentrations ~ 100–350% higher than the blank. Moreover, isoprene emissions varied significantly among poplar genotypes grown in different potting media. Conclusions Tandem instrumentation offers a powerful tool for profiling volatile molecular markers and elucidating their genetic and environmental underpinnings. This approach enhances our ability to predict BVOC emissions in response to genotype by environmental interactions and contributes to a deeper understanding of vegetation responses to environmental changes.

Biogenic volatile organic compounds

Dataset for First Full Dalitz Plot Measurement in Neutron β-Decay using the Nab Spectrometer and Implications for New Physics

The Nab apparatus at the Fundamental Neutron Physics Beamline at the Spallation Neutron Source was designed to measure key observations in neutron beta decay, test the Standard Model's description of the weak interaction, and search for new physics. This data was collected using the Nab apparatus and are presented in the article "First Full Dalitz Plot Measurement in Neutron β-Decay using the Nab Spectrometer and Implications for New Physics." This data publication includes CSV (comma-separated values) files which are used to generate Figures 3 - 11 in the linked journal article.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS

Fast data-driven spectrometer with direct measurement of time and frequency for multiple single photons

We present a single-photon-sensitive spectrometer based on a linear array of 512 single-photon avalanche diode detectors with 0.04 nm spectral and 40 ps temporal resolutions. We employ a fast data-driven operation that allows direct measurement of time and frequency for simultaneous single photons, time- and frequency-stamping each single-photon detection. Our results combine excellent temporal and spectral resolution. This work opens numerous applications in quantum photonics, especially when both spectral and temporal properties of single photons can be exploited.

79 ASTRONOMY AND ASTROPHYSICS

Milestone report for MRT 8504: Commission EXAFS spectrometer with spectral range of 17.95-18.6 keV design to obtain EXAFS data for Pu L shell experiments

This milestone describes the development and fielding of EXAFS Phase II spectrometer designed to provide high quality (SNR>=5) EXAFS spectra for Plutonium measurements at the National Ignition facility (NIF). Benefits: the EXAFS data will be used by the High Energy Density (HED) Physics and more specifically the Focused Material Science program to measure the thermal state of compressed materials with good temperature sensitivity (~100-1000 Kelvin). Data with good signal to noise ratio (SNR>=5) and good spectral resolution allows the FMS program to fill a gap in diagnosing temperature to completely constrain material properties for weapon physics and Stockpile Stewardship applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Continued Evaluation of the Use of a Raman Spectrometer for H-Canyon Dissolver Monitoring

Remote monitoring of dissolver activities in H-Canyon can help operators avoid delays associated with excessive levels of fuel fragments remaining after a run. SRNL has proposed that effective monitoring can be achieved by using a Raman spectrometer to measure NO 2 concentrations in the offgas stream sampled from the facility stack. Prior work (SRNL-STI-2021-00451) measuring the offgas from one dissolution batch of High Flux Isotope Reactor (HFIR) fuel suggested a relationship between %NO 2 levels and fragment height. Herein, we report the results of monitoring and analysis of the dissolution of four batches of Material Test Reactor (MTR) fuel. A rigorous quantitative relationship between %NO 2 measurements and fragment heights could not be established, due to high uncertainties associated with both measurements. Uncertainties with gas measurements are associated with the %NO 2 levels in the offgas being close to the detection limit for the analyzer. Alternative gas measurement strategies are discussed which could improve sensitivity and reduce uncertainty. Limitations to the precision of the probe measurements are also discussed. It is also noted that the offgas is an average of the products from simultaneous dissolution of elements in multiple wells. Detection of a high fragment height level in an individual well may be hindered by low levels in other wells.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W

Characterization of the Multi-Coincident Bismuth Germanate Oxide Spectrometer at the Nuclear Counting Facility

A multi-detector γ-ray spectroscopy system including 3 high-purity germanium (HPGe) detectors has been developed at the Nuclear Counting Facility at Lawrence Livermore National Laboratory. This system operates not only in conventional singles γ-ray detection mode but also incorporates features like coincidence and anti-coincidence techniques. These advanced detection modes can significantly enhance the system’s sensitivity, making it a powerful tool for isotope identification and quantification, especially for complex samples with high background and overlapping peaks. In this re port, we present a comprehensive performance characterization of the Multi-Coincident Bismuth Oxide Spectrometer (MCBOS) using a variety of sample types, including 60 Co, 48 Sc, and mixed fission product samples. Each sample provides unique tests for the MCBOS capabilities. Additionally, a GEANT4 model of the MCBOS has been generated to aid with the characterization of the system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND