Search NASA⌕ Search

SEARCH · Search NASA

Results for “Storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Mycorrhizal associations of temperate forest seedlings mediate rhizodeposition, but not soil carbon storage, under elevated nitrogen availability

Abstract Tree‐mycorrhizal associations are associated with patterns in nitrogen (N) availability and soil organic matter storage; however, we still lack a mechanistic understanding of what tree and fungal traits drive these patterns and how they will respond to global changes in soil N availability. To address this knowledge gap, we investigated how arbuscular mycorrhizal (AM)‐ and ectomycorrhizal (EcM)‐associated seedlings alter rhizodeposition in response to increased seedling inorganic N acquisition. We grew four species each of EcM and AM seedlings from forests of the eastern United States in a continuously 13 C‐labeled atmosphere within an environmentally controlled chamber and subjected to three levels of 15 N‐labeled fertilizer. We traced seedling 15 N uptake from, and 13 C‐labeled inputs (net rhizodeposition) into, root‐excluded or ‐included soil over a 5‐month growing season. N uptake by seedlings was positively related to rhizodeposition for EcM‐ but not AM‐associated seedlings in root‐included soils. Despite this contrast in rhizodeposition, there was no difference in soil C storage between mycorrhizal types over the course of the experiment. Instead root‐inclusive soils lost C, while root‐exclusive soils gained C. Our findings suggest that mycorrhizal associations mediate tree belowground C investment in response to inorganic N availability, but these differences do not affect C storage. Continued soil warming and N deposition under global change will increase soil inorganic N availability and our seedling results indicate this could lead to greater belowground C investment by EcM‐associated trees. This potential for less efficient N uptake by EcM‐trees could contribute to AM‐tree success and a shift toward more AM‐dominated temperate forests.

Fitch, Amelia A.↗

SMART Task 6: Evaluation of the Costs of Geologic CO2 Storage for the Illinois Basin Decatur Project Site Using the NRAP/SMART Technoeconomic and Liability Evaluation for Storage (TALES) Model

This is a presentation featuring an analysis related to SMART Task 6 in which CO2 storage costs are presented. The National Energy Technology Laboratory has developed the NRAP/SMART Technoeconomic and Liability Evaluation for Storage (TALES) model to provide quantitative cost-based insights to support developers planning CO2 injection and storage projects. TALES calculates the revenues, costs, and financial performance of candidate CO2 saline storage project based on site-specific activity costs and financial parameters. TALES is being integrated as a module pertaining to storage cost as part of the broader SMART Visualization and Decision Support Platform (SVDSP). In this study, the TALES model was applied using real activity cost data associated with the development and operations at the Illinois Basin Decatur Project (IBDP) CO2 storage project site. Scenario analysis was implemented in which crucial operational and cost attributes were varied and the associated cost implications observed. Key results data and project cost summary metrics like first-year breakeven price of CO2 ($/tonne) and net present value (NPV) are presented in similar fashion to how they will appear in the SVDSP.

Vikara, Derek↗

Storage management in Ada. Three reports. Volume 1: Storage management in Ada as a risk to the development of reliable software. Volume 2: Relevant aspects of language. Volume 3: Requirements of the language versus manifestations of current implementations

The risk to the development of program reliability is derived from the use of a new language and from the potential use of new storage management techniques. With Ada and associated support software, there is a lack of established guidelines and procedures, drawn from experience and common usage, which assume reliable behavior. The risk is identified and clarified. In order to provide a framework for future consideration of dynamic storage management on Ada, a description of the relevant aspects of the language is presented in two sections: Program data sources, and declaration and allocation in Ada. Storage-management characteristics of the Ada language and storage-management characteristics of Ada implementations are differentiated. Terms that are used are defined in a narrow and precise sense. The storage-management implications of the Ada language are described. The storage-management options available to the Ada implementor and the implications of the implementor's choice for the Ada programmer are also described.

Auty, David↗

Energy storage systems including thermal storage tanks

Energy storage systems include a heat source and a thermal energy storage system to store thermal energy produced by the heat source. The thermal energy storage system includes a first tank containing a first salt having a first melting temperature and a second tank containing a second salt having a second melting temperature. At least one input conduit is configured for transferring thermal energy from the heat source to the first tank and second tank. A first output conduit is in thermal communication with the first tank. A second output conduit is in thermal communication with the second tank. Additional energy storage systems include a heat booster positioned and configured to add thermal energy to a heated heat transfer fluid prior to reaching a tank containing at least one thermal storage material. Methods include transferring thermal energy from a thermal energy source to a plurality of thermal energy storage tanks.

McKellar, Michael G.↗

Storage Futures Study: Economic Potential of Diurnal Storage in the U.S. Power Sector

We model the evolution of the U.S. electricity sector from 2020 through 2050 and find significant market potential (>125 GW) for diurnal energy storage across all 19 scenarios considered. Most of this storage has 4-6 hours of duration. We find that storage deployment is driven primarily by the combination of capacity value and energy time-shifting value, and that the combination of these value streams is needed for optimal storage deployment to be realized. We also find a strong correlation of PV penetration and storage market potential. Cost and performance metrics in this study focus on Li-ion batteries because the technology has more market maturity than other emerging technologies but results from this study can be generalized to any technologies that meet the cost and performance projections assumed.

25 ENERGY STORAGE↗

Storage Futures Study: Grid Operational Impacts of Widespread Storage Deployment

This report, the fifth in the Storage Futures Study series, uses cost-driven scenarios from the ReEDS model as a starting point to examine the operational impacts of grid-scale storage deployment and relationships between this deployment and the contribution of variable renewable energy. We use commercial production cost modeling software to evaluate hourly operation of five scenarios that reach between 210 gigawatts (GW) and 930 GW of installed storage by 2050. We find that storage plays an important role in these power systems between now and 2050 - by storing the lowest-marginal cost generation (often, overgeneration from solar or wind plants) and generating energy during the highest net load periods of the day and year. Storage helps with the integration of variable renewable energy and by providing an important resource to provide continued reliable power.

25 ENERGY STORAGE↗

Storage Futures Study: Grid Operational Impacts of Widespread Storage Deployment

This report, the fifth in the Storage Futures Study series, uses cost-driven scenarios from the ReEDS model as a starting point to examine the operational impacts of grid-scale storage deployment and relationships between this deployment and the contribution of variable renewable energy. We use commercial production cost modeling software to evaluate hourly operation of five scenarios that reach between 210 gigawatts (GW) and 930 GW of installed storage by 2050. We find that storage plays an important role in these power systems between now and 2050 - by storing the lowest-marginal cost generation (often, overgeneration from solar or wind plants) and generating energy during the highest net load periods of the day and year. Storage helps with the integration of variable renewable energy and by providing an important resource to provide continued reliable power.

battery↗

Storage Futures Study: The Challenge of Defining Long-Duration Energy Storage

This document explores the definition of "long duration" as applied to energy storage. Given the growing use of this term, a uniform definition could aid in communication and consistency among various stakeholders. There is large and growing use of the ARPA-E definition of greater than 10 hours. However, the term "long-duration energy storage" is often used as shorthand for storage with sufficient duration to provide firm capacity and support grid resource adequacy. The actual duration needed for this application varies significantly from as little as a few hours to potentially multiple days. This leads to the unsatisfying conclusion that there cannot be a simple, uniform, and static definition of long duration storage that captures its ability to provide firm capacity and also aids consistent communication.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Screening of alkali-assisted storage conditions to define the operational window of deacetylation within storage systems in the bioenergy supply chain

Overcoming biomass heterogeneity and associated recalcitrance to thermal, chemical, and enzymatic depolymerization is a necessary but challenging aspect of valorizing lignocellulosic biomass to fuels and chemicals. Here, this study explores how this recalcitrance can be reduced during the supply chain unit operation of storage, which is required for seasonally harvested agricultural residues to maintain constant throughput at a biorefinery. In this work, partial alkali pretreatment was performed just prior to corn stover entering storage, which had the benefit of providing a high pH environment entering storage such that soluble sugars were preserved and saponified acetyl groups in hemicellulose. This work investigated a range of viable conditions where saponification and preservation occur simultaneously by varying the moisture content (40% and 60%) and concentrations of sodium hydroxide (low and high) during aerobic and anaerobic storage. Anaerobic conditions preserved overall dry matter below 5% in the three scenarios evaluated, and the highest alkali loading solubilized up to 15% lignin, 18% xylan, and 50% of acetate, meanwhile doubling the extractable components. Scanning electron microscopy images highlighted potential physical impacts including cell-wall disruption near vascular bundles, pitting within parenchyma cells, and cell-wall distortion. Techno-economic assessment indicated that this storage approach and associated logistics system is economically competitive with a conventional approach using low-moisture bales.

09 BIOMASS FUELS↗

Determining the profitability of energy storage over its life cycle using levelized cost of storage

Levelized cost of storage (LCOS) can be a simple, intuitive, and useful metric for determining whether a new energy storage plant would be profitable over its life cycle and to compare the cost of different energy storage technologies. However, researchers and industry decision makers still use conflicting definitions of LCOS. For example, some include charging cost, while others only include round trip efficiency (RTE) losses. Additionally, inputs to the existing formulations are not specific enough to generate repeatable results across studies, which reduces trust in the metric. To push for standardization in economic assessment of batteries and other energy storage devices, the authors review existing definitions of LCOS and identify the desired characteristics for a standard. They then propose a new definition and demonstrate that it fits these characteristics very well relative to other prominent options. Unit analysis is applied to this proposed definition to provide a deeper understanding of the equations and to demonstrate its effectiveness. Finally, the sensitivity of LCOS to different input parameters is investigated to help users understand how to compare analyses from literature to their own. The authors also provide a spreadsheet and a Python script to streamline adoption of the proposed definition.

25 ENERGY STORAGE↗

Pumped-Storage Hydropower using Abandoned Underground Mines (PSH-AUM) as an Innovative Energy Storage Technology for Fossil-Integrated Systems

Pumped-storage hydropower (PSH) provides around 95% of all utility-scale energy storage in the U.S. and globally. Additional deployment of PSH is hampered by excessively long permitting and commissioning requirements and is constrained to locations for which natural topography provides suitable elevation relief between the upper and lower reservoirs (the ΔH challenge). The purpose of this research was to evaluate Pumped-Storage Hydropower using Abandoned Underground Mines (PSH-AUM) as a means to solve the ΔH challenge and initiate the commercialization pathway for a promising new energy storage technology. Four primary tasks were conducted: Screening and ranking of candidate sites for project development; multiphase reservoir modeling to evaluate mine performance; techno-economic analysis and preliminary designs for PSH-AUM systems integrated with fossil-fuel power units; and stakeholder engagement to identify pathways to commercialization of this new technology. Key results were achieved in each of the four primary tasks. Candidate site screening determined that nearly 10,000 underground mines were spatially locatable, of which more than 100 sites appear suitable for integration with existing fossil power plants that are expected to remain in longer-term operation. Mine reservoir models were developed using PNNL’s STOMP simulator and parameterized using candidate site data to evaluate interactions with the surrounding groundwater system and confirm the potential for some mines to accommodate inflows and outflows on the order of 100 m3/s over 8-hour durations (1.6 GWh system) without excessive aqueous pressures. Techno-economic analysis resulted in a project cost optimization scheme to identify key sensitivities and the development of preliminary designs that can minimize overall costs of deployment. Finally, stakeholder engagement with industry, state government, and local economic development leaders confirmed the viability of PSH-AUM as a promising new technology. Our Phase I project results suggest that PSH-AUM technology has a domestic market potential on the order of $100+ Billion with ample space for technology development to commercialization within the next decade.

13 HYDRO ENERGY↗

Interfacing HDF5 with a scalable object‐centric storage system on hierarchical storage

Summary Object storage technologies that take advantage of multitier storage on HPC systems are emerging. However, to use these technologies at present, applications have to be modified significantly from current I/O libraries. HDF5, a widely used I/O middleware on HPC systems, provides a virtual object layer (VOL) that allows applications to connect to different storage mechanisms transparently without requiring significant code modifications. We recently designed the proactive data containers (PDC) object‐centric storage system that provides the capabilities of transparent, asynchronous, and autonomous data movement taking advantage of multiple storage tiers—a decision that has so far been left upon the user on most current systems. To enable PDC's features through HDF5 without modifying application codes, we have developed an HDF5 VOL connector that interfaces with PDC. We present in this article the connector interface and evaluate its performance on Cori, a Cray XC40 supercomputer located at the National Energy Research Scientific Computing Center (NERSC). Our evaluation demonstrates up to an 8× improvement compared with HDF5 that has the most recent optimizations.

Mu, Jingqing↗

Ambient-Temperature Hydrogen Storage via Vanadium(II)-Dihydrogen Complexation in a Metal-Organic Framework

In this report, the widespread implementation of H 2 as a fuel is currently hindered by the high pressures or cryogenic temperatures required to achieve reasonable storage densities. In contrast, the realization of materials that strongly and reversibly adsorb hydrogen at ambient temperatures and moderate pressures could transform the transportation sector and expand adoption of fuel cells in other applications. To date, however, no adsorbent has been identified that exhibits a binding enthalpy within the optimal range of -15 to -25 kJ/mol for ambient-temperature hydrogen storage. Here, we report the hydrogen adsorption properties of the metal-organic framework (MOF) V 2 Cl 2.8 (btdd) (H 2 btdd, bis(1 H -1,2,3-triazolo[4,5- b ],[4',5'- i ])dibenzo[1,4]dioxin), which features exposed vanadium(II) sites capable of backbonding with weak π acids. Significantly, gas adsorption data reveal that this material binds H 2 with an enthalpy of -21 kJ/mol. This binding energy enables usable hydrogen capacities that exceed that of compressed storage under the same operating conditions. The Kubas-type vanadium(II)-dihydrogen complexation is characterized by a combination of techniques. From powder neutron diffraction data, a V-D 2 (centroid) distance of 1.966(8) Å is obtained, the shortest yet reported for a MOF. Using in situ infrared spectroscopy, the H-H stretch was identified, and it displays a red shift of 242 cm -1 . Electronic structure calculations show that a main contribution to bonding stems from the interaction between the vanadium d π and H 2 σ* orbital. Ultimately, the pursuit of MOFs containing high densities of weakly π-basic metal sites may enable storage capacities under ambient conditions that far surpass those accessible with compressed gas storage.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

CO2 Saline Storage: Costs and Storage Capacity

This document provides a brief description of the current state of CO2 saline storage. It then discusses factors determining the cost of storage and provides examples for two storage formations. It concludes by discussing the factors influencing CO2 storage capacity and provides cost supply cirves for CO2 storage.

Morgan, David↗

Performance Modeling of Network-Attached Storage Device Based Hierarchical Mass Storage Systems

Network attached storage devices improve I/O performance by separating control and data paths and eliminating host intervention during the data transfer phase. Devices are attached to both a high speed network for data transfer and to a slower network for control messages. Hierarchical mass storage systems use disks to cache the most recently used files and a combination of robotic and manually mounted tapes to store the bulk of the files in the file system. This paper shows how queuing network models can be used to assess the performance of hierarchical mass storage systems that use network attached storage devices as opposed to host attached storage devices. Simulation was used to validate the model. The analytic model presented here can be used, among other things, to evaluate the protocols involved in 1/0 over network attached devices.

Menasce, Daniel A.↗

Thermal energy storage apparatus, controllers and thermal energy storage control methods

Thermal energy storage apparatus, controllers and thermal energy storage control methods are described. According to one aspect, a thermal energy storage apparatus controller includes processing circuitry configured to access first information which is indicative of surpluses and deficiencies of electrical energy upon an electrical power system at a plurality of moments in time, access second information which is indicative of temperature of a thermal energy storage medium at a plurality of moments in time, and use the first and second information to control an amount of electrical energy which is utilized by a heating element to heat the thermal energy storage medium at a plurality of moments in time.

Hammerstrom, Donald J.↗