Search NASA⌕ Search

SEARCH · Search NASA

Results for “Structured scintillator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Enhanced light extraction of scintillator using large-area photonic crystal structures fabricated by soft-X-ray interference lithography

Soft-X-ray interference lithography is utilized in combination with atomic layer deposition to prepare photonic crystal structures on the surface of Bi{sub 4}Ge{sub 3}O{sub 12} (BGO) scintillator in order to extract the light otherwise trapped in the internal of scintillator due to total internal reflection. An enhancement with wavelength- and emergence angle-integration by 95.1% has been achieved. This method is advantageous to fabricate photonic crystal structures with large-area and high-index-contrast which enable a high-efficient coupling of evanescent field and the photonic crystal structures. Generally, the method demonstrated in this work is also suitable for many other light emitting devices where a large-area is required in the practical applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Dense Plasma Globule in the Solar Neighborhood

The radio source J1819+3845 underwent a period of extreme interstellar scintillation between circa 1999 and 2007. The plasma structure responsible for this scintillation was determined to be just 1–3 pc from the solar system and to posses a density of n{sub e}∼10{sup 2} cm{sup −3}, which is three orders of magnitude higher than the ambient interstellar density. Here we present radio-polarimetric images of the field toward J1819+3845 at wavelengths of 0.2, 0.92, and 2 m. We detect an elliptical plasma globule of approximate size 1{sup ∘}×≳2{sup ∘} (major-axis position angle of ≈−40{sup ∘}), via its Faraday-rotation imprint (≈15 rad m{sup −2}) on the diffuse Galactic synchrotron emission. The extreme scintillation of J1819+3845 was most likely caused at the turbulent boundary of the globule (J1819+3845 is currently occulted by the globule). The origin and precise nature of the globule remain unknown. Our observations represent the first time that plasma structures which likely cause extreme scintillation have been directly imaged.

79 ASTRONOMY AND ASTROPHYSICS↗

Near-Sun solar wind consequences of solar structure and dynamic phenomena observed by radio scintillation measurements

Since radio propagation measurements using either natural or spacecraft radio signals are used for probing the solar wind in the vicinity of the sun, they represent a key tool for studying the interplanetary consequences of solar structure and dynamic phenomena. New information on the near sun consequences was obtained from radio scintillation observations of coherent spacecraft signals. The results covering density fluctuations, fractional density fluctuations, coronal streamers, heliospheric current sheets, coronal mass ejections and interplanetary shocks are reviewed. A joint ICE S-band (13 cm wavelength) Doppler scintillation measurement with the SOHO white-light coronograph (LASCO) is described.

Woo, Richard↗

Single scattering estimates for the scintillation function of waves in random media

The energy density of high frequency waves propagating in highly oscillatory random media is well approximated by solutions of deterministic kinetic models. The scintillation function determines the statistical instability of the kinetic solution. This paper analyzes the single scattering term in the scintillation function. This is the term of the scintillation function that is linear in the power spectrum of the random fluctuations. We show that the structure of the scintillation function is already quite complicated in this simplified setting. It strongly depends on the singularity of the initial conditions for the wave field and on the correlation properties of the random medium. We obtain limiting expressions for the scintillation function as the correlation length of the random medium tends to zero.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The sun and the heliosphere in three dimensions; Proceedings of the Nineteenth ESLAB Symposium, Les Diablerets, Switzerland, June 4-6, 1985

Papers are presented on coronal magnetic fields, the heliospheric energy source, stereoscopic measurement of hard solar X-rays, and OVI diagnostics of solar-wind generation. Also considered are coronal transients at high heliospheric latitudes, the solar-cycle dependence of coronal mass ejections, comets and three-dimensional wind structure, and interplanetary scintillation observations of the solar wind at high latitudes. Other topics include three-dimensional coronal and heliospheric structure from radio observations, multispacecraft observations of Type III radio bursts, the acceleration of energetic particles at solar-wind shocks, and a spatially confined, long-lived stream of solar particles.

Marsden, R. G.↗

Ionizing-radiation beam monitoring system

Embodiments are directed generally to an ionizing-radiation beam monitoring system that includes an enclosure structure with at least one ultra-thin window to an incident ionizing-radiation beam. Embodiments further include at least one scintillator within the enclosure structure that is substantially directly in an incident ionizing-radiation beam path and at least one ultraviolet illumination source within the enclosure structure and facing the scintillator. At least one pixelated imaging system within the enclosure structure is located out of an incident ionizing-radiation beam path and includes at least one pixelated photosensor device optically coupled to an imaging lens.

Friedman, Peter S.↗

Ionizing-radiation beam monitoring system

A transmissive ionizing-radiation beam monitoring system includes an enclosure structure with at least one ultra-thin window to an incident ionizing-radiation beam, where the ultra-thin window is highly transmissive to ionizing-radiation. Embodiments include at least one thin or ultra-thin scintillator within the enclosure structure that is substantially directly in an incident ionizing-radiation beam path and transmissive to the incident radiation beam, and at least one ultraviolet (UV) illumination source within the enclosure structure facing the scintillator. Embodiments include at least one machine vision camera within the enclosure structure located out of an incident ionizing-radiation beam path and including a camera body and lens having a projection of its optical axis oriented at an angle of incidence of 45±35 degrees to a surface of the scintillator.

Friedman, Peter S.↗

Investigation of the neutron response anisotropy in crystalline organic scintillators.

An anisotropy in the response of crystalline organic scintillators such as anthracene to neutron elastic scattering interactions has been known for some time. Both the amplitude and the time structure of the scintillation light pulse vary with the direction of the proton recoil with respect to the crystalline axes. In principle, this effect could be exploited to develop compact, high-efficiency fast neutron detectors that have directional sensitivity via a precise measurement of the pulse shape. We are investigating the feasibility and sensitivity of such a detector, particularly for neutrons in the fission energy spectrum. Here we will report new measurements of the pulse shape dependence on proton recoil angle in anthracene and stilbene single crystals, for proton energies in the few MeV range. Digital pulse acquisition and processing are used to allow an exploration of different pulse shape analysis techniques.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

CsMgCl{sub 3}: A promising cross luminescence material

Full-potential linearized augmented plane wave method has been used to study the cross luminescence of halide scintillators. The electronic structure and optical properties of alkali halides such as CsMgCl{sub 3}, CsCaCl{sub 3}, and CsSrCl{sub 3} are presented. One of the major criteria for the cross luminescence to happen is the energy difference between valence band and next deeper core valence band being lesser when compared to energy gap of the compound, so that radiative electronic transition may occur between core valence band and valence band which might lead to fast scintillation. We found this criterion to be satisfied in these compounds leading to cross luminescence. The presence of high energy peaks in the absorption spectra indicates the creation of holes in the core valence band, which is an essential criterion for the occurrence of cross luminescence. The electronic structure, and optical properties studies clearly indicate CsMgCl{sub 3}, CsCaCl{sub 3}, and CsSrCl{sub 3} to be cross luminescence materials comparable to CsCl which is one of the well known fast scintillators. In addition, CsMgCl{sub 3} is found to be better among the studied compounds with optical isotropy though the compound is structurally anisotropic. - Graphical abstract: Absorption spectra of CsMCl{sub 3} (M=Mg, Ca, and Sr) along with CsCl, indicating both the spectra are similar in the lower energy region. - Highlights: • These are cross valence luminescence (CVL) materials with short day time of the order of nanosecond. • Chemical bonding of these compounds studied observed the ionic nature. • These are fast scintillators comparable to their binary halide. • CsMgCl{sub 3} good scintillator with optically isotropic nature.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

MICROSTRUCTURED OPTICAL FIBER FOR X-RAY DETECTION

A novel scintillating optical fiber is presented using a composite micro-structured quartz optical fiber. Scintillating materials are introduced into the multiple inclusions of the fiber. This creates a composite optical fiber having quartz as a cladding with an organic scintillating material core. X-ray detection using these fibers is compared to a collimated cadmium telluride (CdTe) detector over an energy range from 10 to 40 keV. Results show a good correlation between the fiber count rate trend and that of the CdTe detector.

36 MATERIALS SCIENCE↗

Scintillation light from cosmic-ray muons in liquid argon

This paper reports the results of an experiment to directly measure the time-resolved scintillation signal from the passage of cosmic-ray muons through liquid argon. Scintillation light from these muons is of value to studies of weakly-interacting particles in neutrino experiments and dark matter searches. The experiment was carried out at the TallBo dewar facility at Fermilab using prototype light guide detectors and electronics developed for the Deep Underground Neutrino Experiment. Two models are presented for the time structure of the scintillation light, a phenomenological model and a physically-motivated model. Both models find tT = 1:52 ms for the decay time constant of the Ar 2 triplet state. These models also show that the identification of the “early” light fraction in the phenomenological model, FE 25% of the signal, with the total light from singlet decays is an underestimate. The total fraction of singlet light is FS 36%, where the increase over FE is from singlet light emitted by the wavelength shifter through processes with long decay constants. The models were further used to compute the experimental particle identification parameter Fprompt, the fraction of light coming in a short time window after the trigger compared with the light in the total recorded waveform. The models reproduce quite well the typical experimental value 0.3 found by dark matter and double b-decay experiments, which suggests this parameter provides a robust metric for discriminating electrons and muons from more heavily ionizing particles.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Microstructured Optical Fiber for X-ray Detection

A novel scintillating optical fiber is presented using a composite micro-structured quartz optical fiber. Scintillating materials are introduced into the multiple inclusions of the fiber. This creates a composite optical fiber having quartz as a cladding with an organic scintillating material core. X-ray detection using these fibers is compared to a collimated cadmium telluride (CdTe) detector over an energy range from 10 to 40 keV. Results show a good correlation between the fiber count rate trend and that of the CdTe detector.

DeHaven, Stanton L.↗

Toward Scintillator High‐Gain Avalanche Rushing Photoconductor Active Matrix Flat Panel Imager ( SHARP ‐ AMFPI ): Initial fabrication and characterization

Purpose We present the first prototype Scintillator High‐Gain Avalanche Rushing Photoconductor Active Matrix Flat Panel Imager ( SHARP ‐ AMFPI ). This detector includes a layer of avalanche amorphous Selenium (a‐Se) ( HARP ) as the photoconductor in an indirect detector to amplify the signal and reduce the effects of electronic noise to obtain quantum noise‐limited images for low‐dose applications. It is the first time avalanche a‐Se has been used in a solid‐state imaging device and poses as a possible solution to eliminate the effects of electronic noise, which is crucial for low‐dose imaging performance of AMFPI . Methods We successfully deposited a solid‐state HARP structure onto a 24 × 30 cm 2 array of thin‐film transistors ( TFT array) with a pixel pitch of 85 μm. The HARP layer consists of 16 μm of a‐Se with a hole‐blocking and electron‐blocking layer to prevent charge injection from the high‐voltage bias and pixel electrodes, respectively. An electric field ( E S e ) up to 105 V μm −1 was applied across the a‐Se layer without breakdown. A 150 μm thick‐structured CsI:Tl scintillator was used to form SHARP ‐ AMFPI . The x‐ray imaging performance is characterized using a 30 kV p Mo/Mo beam. We evaluate the spatial resolution, noise power, and detective quantum efficiency at zero frequency of the system with and without avalanche gain. The results are analyzed using cascaded linear system model ( CLSM ). Results An avalanche gain of 76 ± 5 was measured at E S e = 105 V μm −1 . We demonstrate that avalanche gain can amplify the signal to overcome electronic noise. As avalanche gain is increased, image quality improves for a constant (0.76 mR ) exposure until electronic noise is overcome. Our system is currently limited by poor optical transparency of our high‐voltage electrode and long integrating time which results in dark current noise. These two effects cause high‐spatial frequency noise to dominate imaging performance. Conclusions We demonstrate the feasibility of a solid‐state HARP x‐ray imager and have fabricated the largest active area HARP sensor to date. Procedures to reduce secondary quantum and dark noise are outlined. Future work will improve optical coupling and charge transport which will allow for frequency DQE and temporal metrics to be obtained.

Scheuermann, James R.↗

Data-driven exploration of the ionization-phonon partitioning in scintillating radiation detector materials

An information-based approach to scintillating materials development has been applied to ranking the alkali halide and alkali earth halide series in terms of their energy conversion efficiency. The efficiency of scintillating radiation detection materials can be viewed as the product of a consecutive series of electronic processes (energy conversion, transfer, and luminescence) as outlined by Lempicki and others. Relevant data are relatively sparse, but sufficient for the development of forward mapping of materials properties through materials signatures. These mappings have been used to explore the limits of the K ratio in the Lempicki model with chemical composition, and examine its relationship with another common design objective, density. The alkali halides and alkali earth halide compounds separate themselves into distinct behavior classes favoring heavier cations and anions for improved K ratio. While the coupling of ionization is strongly related to the optical phonon modes, both dielectric and band gap contributions cannot be ignored. When applied within a candidate screen, the resulting model for K imposes design rules—simple structural restrictions—on scintillating radiation detector materials.

36 MATERIALS SCIENCE↗