Search NASA⌕ Search

SEARCH · Search NASA

Results for “Superconducting Detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Center for Applied Physics and Superconducting Technologies (CAPST)

Fermi Research Alliance, LLC, as operator of Fermi National Accelerator Laboratory (Fermilab) and Northwestern University (Northwestern) have a broad overlap in scientific interests and complementary state-of-the-art facilities in the area of applied physics and technology, in particular physics of superconductivity, materials science, and detector technology. The Center for Applied Physics and Superconducting Technology (CAPST) will provide a mechanism for cross-utilizing capabilities of the two institutions for advances in understanding key scientific problems of mutual interest and opening up broader educational opportunities for students and postdoctoral candidates (postdocs). Northwestern undergraduate students, graduate students and postdocs will be able to perform cutting edge science and technology research in accelerator and detector science and the physics of superconductivity at Fermilab and Northwestern under the joint direction of Fermilab researchers and Northwestern professors. Research program covers three thrusts below, with subtopics detailed in the CRADA: • Vortex dynamics in superconductors • Superconducting devices • New frontiers in microwave instrumentation/techniques.

47 OTHER INSTRUMENTATION↗

A superconducting nanowire binary shift register

We present a design for a superconducting nanowire binary shift register, which stores digital states in the form of circulating supercurrents in high-kinetic-inductance loops. Adjacent superconducting loops are connected with nanocryotrons, three-terminal electrothermal switches, and fed with an alternating two-phase clock to synchronously transfer the digital state between the loops. A two-loop serial-input shift register was fabricated with thin-film NbN and a bit error rate of less than 10 –4 was achieved, when operated at a maximum clock frequency of 83 MHz and in an out-of-plane magnetic field of up to 6 mT. A shift register based on this technology offers an integrated solution for low-power readout of superconducting nanowire single photon detector arrays and is capable of interfacing directly with room-temperature electronics and operating unshielded in high magnetic field environments.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The SAND detector for the DUNE experiment

The Deep Underground Neutrino Experiment (DUNE) is a next-generation project aiming to study several neutrino properties. It will feature two experimental setups: a near detector that will be installed at Fermilab, in proximity of the neutrino-production point, and a far detector at a distance of 1300 km and 1500 m underground, at the SURF laboratory. The DUNE design and configuration will allow the study of neutrino oscillation, astrophysical neutrinos, and beyond standard model physics. The near detector complex foresees three detectors to be installed. Among these, the System for on-Axis Neutrino Detection (SAND) will serve as on-axis beam monitor, reduce the systematic uncertainties for the oscillation analysis, and search for physics beyond the standard model. SAND will be composed of three sub-detectors, surrounded by a 0.6 T superconducting magnet. The outermost detector will be a lead/scintillating-fiber electromagnetic calorimeter while the inner volume will include a 1-ton liquid argon active target placed upstream followed by a target tracker system. The SAND detector and its goals will be shown in this poster.

Alemanno, Francesca [Salento U.; INFN, Lecce]↗

Improved microwave SQUID multiplexer readout using a kinetic-inductance traveling-wave parametric amplifier

We report on the use of a kinetic-inductance traveling-wave parametric amplifier (KITWPA) as the first amplifier in the readout chain of a microwave superconducting quantum interference device (SQUID) multiplexer (μmux). This μmux is designed to multiplex signals from arrays of low temperature detectors, such as superconducting transition-edge sensor microcalorimeters. When modulated with a periodic flux-ramp to linearize the SQUID response, the flux noise improves, on average, from 1.6 μ $\Phi$ 0 /$\sqrt{Hz}$ with the KITWPA off to 0.77 μ $\Phi$ 0 /$\sqrt{Hz}$ with the KITWPA on. When statically biasing the μmux to the maximally flux-sensitive point, the flux noise drops from 0.45 μ $\Phi$ 0 /$\sqrt{Hz}$ to 0.2 μ $\Phi$ 0 /$\sqrt{Hz}$⁠. We validate this new readout scheme by coupling a transition-edge sensor microcalorimeter to the μmux and detecting background radiation. In conclusion, the combination of μmux and KITWPA provides a variety of new capabilities including improved detector sensitivity and more efficient bandwidth utilization.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Improving wafer-scale Josephson junction resistance variation in superconducting quantum coherent circuits

Quantum bits, or qubits, are an example of coherent circuits envisioned for next-generation computers and detectors. A robust superconducting qubit with a coherent lifetime of O (100 µs) is the transmon: a Josephson junction functioning as a non-linear inductor shunted with a capacitor to form an anharmonic oscillator. In a complex device with many such transmons, precise control over each qubit frequency is often required, and thus variations of the junction area and tunnel barrier thickness must be sufficiently minimized to achieve optimal performance while avoiding spectral overlap between neighboring circuits. Simply transplanting our recipe optimized for single, stand-alone devices to wafer-scale (producing 64, 1x1 cm dies from a 150 mm wafer) initially resulted in global drifts in room-temperature tunneling resistance of ± 30%. Inferring a critical current variation from this resistance distribution, we present an optimized process developed from a systematic 38 wafer study that results in < 3.5% relative standard deviation (RSD) in critical current ( ) for 3000 Josephson junctions (both single-junctions and asymmetric SQUIDs) across an area of 49 cm 2 . Looking within a 1x1 cm moving window across the substrate gives an estimate of the variation characteristic of a given qubit chip. Our best process, utilizing ultrasonically assisted development, uniform ashing, and dynamic oxidation has shown = 1.8% within 1x1 cm, on average, with a few 1x1 cm areas having < 1.0% (equivalent to < 0.5%). Such stability would drastically improve the yield of multi-junction chips with strict critical current requirements.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Rutherford-in-Copper-Channel Conductor for the MARCO Solenoidal Detector Magnet

MARCO will be a superconducting solenoid for a new particle physics detector of the upcoming Electron Ion Collider (EIC) at Brookhaven National Laboratory (NY, USA). The design field at the interaction point is 2.0 T with a nominal current of about 4 kA at 4.5 K. For this magnet, an aluminumstabilized conductor was considered at the very preliminary design phase. After that, since the lack of manufacturers able to deal with aluminum extrusion, copper has been chosen as stabilizer. Thanks to a dedicated design effort, the copper stabilizer and accompanying material choices provided acceptable hadronic interaction length. The conductor is based on a NbTi Rutherford cable that is soldered in a U-shaped copper profile. Here, this paper goes through the definition of the conductor crosssection according to the project requirements and the supplier capabilities. Its characteristics will be detailed and discussed, in particular the RRR and the yield strength of the copper channel needed for protection and mechanics respectively. Finally, a proposal on how to make the joint between two conductors is presented.

Stacchi, Francesco [Commissariat a l'Energie Atomi↗

ADMX SLIC: Results from a Superconducting $\textit{LC}$ Circuit Investigating Cold Axions

Axions are a promising cold dark matter candidate. Haloscopes, which use the conversion of axions to photons in the presence of a magnetic field to detect axions, are the basis of microwave cavity searches such as the Axion Dark Matter eXperiment (ADMX). To search for lighter, low frequency axions in the sub-2 × 10 –7 eV (50 MHz) range, a tunable lumped-element $\textit{LC}$ circuit has been proposed. For the first time, through ADMX SLIC (Superconducting $\textit{LC}$ Circuit Investigating Cold Axions), a resonant $\textit{LC}$ circuit was used to probe this region of axion mass-coupling space. The detector used a superconducting $\textit{LC}$ circuit with piezoelectric driven capacitive tuning. The axion mass and corresponding frequency ranges 1.7498–1.7519 × 10 –7 eV (42.31–42.36 MHz), 1.7734–1.7738 × 10 –7 eV (42.88–42.89 MHz), and 1.8007–1.8015 × 10 –7 eV (43.54–43.56 MHz) were covered at magnetic fields of 4.5 T, 5.0 T, and 7.0 T, respectively. Exclusion results from the search data, for coupling below 10 –12 GeV –1 , are presented.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A nanocryotron memory and logic family

The development of superconducting electronics based on nanocryotrons has been limited so far to few device circuits, in part due to the lack of standard and robust logic cells. Here, we introduce and experimentally demonstrate designs for a set of nanocryotron-based building blocks that can be configured and combined to implement memory and logic functions. The devices were fabricated by patterning a single superconducting layer of niobium nitride and measured in liquid helium on a wide range of operating points. The tests show 10 - 4 bit error rates with above ± 20 % margins up to 50 MHz and the possibility of operating under the effect of an out-of-plane 36 mT magnetic field, with ± 30 % margins at 10 MHz. Additionally, we designed and measured an equivalent delay-flip-flop made of two memory cells to show the possibility of combining multiple building blocks to make larger circuits. These blocks may constitute a solid foundation for the development of nanocryotron logic circuits and finite-state machines with potential applications in the integrated processing and control of superconducting nanowire single-photon detectors.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Spontaneous generation of athermal phonon bursts within bulk silicon causing excess noise, low energy background events, and quasiparticle poisoning in superconducting sensors

Solid state phonon detectors used in the search for dark matter and coherent neutrino nucleus interactions (CE $v$ NS) require excellent energy resolution (eV-scale or below) and low backgrounds. An unknown source of phonon bursts, the low energy excess (LEE), dominates other above-threshold backgrounds and generates excess shot noise from subthreshold bursts. Here, in this paper, we measure these phonon bursts for 12 days after cooldown in two nearly identical 1 cm 2 silicon detectors that differ only in the thickness of their substrate (1 vs 4 mm thick). We find that both the channel-correlated shot noise and near-threshold shared LEE relax with time since cooldown. Additionally, both the correlated shot noise and LEE rates scale linearly with substrate thickness. When combined with previous measurements of other silicon phonon detectors with different substrate geometries and mechanical support strategies, these measurements strongly suggest that the dominant source of both above and below threshold LEE is the bulk substrate. By monitoring the relation between bias power and excess phonon shot noise, we estimate that the energy scale for subthreshold noise events is 0.68 ± 0.38 meV. In our final dataset, we report a world-leading energy resolution of 258.5 ± 0.4 meV in the 1 mm thick detector. Simple calculations suggest that these silicon substrate phonon bursts are likely a significant source of quasiparticle poisoning in superconducting qubits operated in well shielded and vibration free environments.

Chang, C. L. [Argonne National Laboratory 1 , 9700↗

Development of a novel bunch oscillation recorder with RFSoC technology

The SuperKEKB accelerator is designed to achieve unprecedented luminosity levels, but this goal is currently hindered by Sudden Beam Loss (SBL) events. These events not only obstruct luminosity improvement but also pose a significant risk to accelerator components, the Belle II detectors, and the superconducting focusing system, potentially leading to severe damage and quenching of the superconducting system. Here, to address this critical challenge, we have developed a novel Bunch Oscillation Recorder (BOR) based on RFSoC technology. The BOR has demonstrated high precision with a position resolution of 0.03 mm, making it a powerful tool for real-time beam monitoring. In its initial deployment, the BOR successfully recorded multiple SBL events, providing valuable data for further analysis. By strategically positioning BORs at the suspected points of SBL origin, we aim to directly identify sources of beam instability. We anticipate that this portable, high-speed BOR monitor will play a crucial role in resolving the SBL issue, ultimately helping achieve SuperKEKB's luminosity targets.

Beam diagnostics↗

Cryogenic Platforms at Fermilab: Recent Results and Outlook

The Cosmic Quantum group at Fermilab operates three cryogenic facilities dedicated to the development and calibration of superconducting low-threshold detectors and qubits. One of which (LOUD) is located at the surface, while the other two (NEXUS and QUIET) are located 100 m underground enabling low-background device characterization and rare event searches. Recently, we have demonstrated world-leading resolution in the quasiparticle channel for kinetic inductance phonon-mediated detectors as well as the lowest rate of spatially- and temporally- correlated errors ( charge jumps ) in superconducting qubit chips. We have additionally made significant progress in expanding the suite of tools for simulating signal production and readout of these devices. In this talk, I will review these recent results, discuss some nascent projects focused on enhancing sensitivity of these detectors to sub-GeV dark matter, and highlight activities in these facilities over the next year.

Temples, Dylan J.↗

A model for excess Johnson noise in superconducting transition-edge sensors

Transition-edge sensors (TESs) are two-dimensional superconducting films utilized as highly sensitive detectors of energy or power. These detectors are voltage biased in the superconducting-normal transition where the film resistance is both finite and a strong function of temperature. Unfortunately, the amount of electrical noise observed in TESs exceeds the predictions of existing noise theories. We describe a possible mechanism for the unexplained excess noise, which we term “mixed-down noise.” The source is Johnson noise, which is mixed down to low frequencies by Josephson oscillations in devices with a nonlinear current–voltage relationship. We derive an expression for the power spectral density of this noise and show that its predictions agree with measured data.

Wessels, Abigail (ORCID:0000000173918339)↗

Direct Measurement of the Be 7 L / K Capture Ratio in Ta-Based Superconducting Tunnel Junctions

We report a high-statistics measurement of the L / K orbital electron capture ratio in 7 Be embedded in cryogenic Ta. The thin Ta film formed part of a high-resolution superconducting tunnel junction radiation detector that was used to identify the signals from different decay channels. The measured L/K capture ratio of 0.070(7) is significantly larger than the only previous measurement of this quantity and the theoretical predictions that include in-medium effects. This value is a uniquely sensitive probe of the 1s and 2s orbital overlaps with the nucleus and is of relevance to nuclear and atomic physics, as well as Li production in novae and other astrophysical scenarios. Furthermore, this is the first experiment that uses superconducting tunnel junctions for nuclear-recoil detection, opening a new experimental avenue for low-energy precision measurements with rare isotopes.

6 ≤ A ≤ 19↗

Electromagnetic Properties of Aluminum-based Bilayers for Kinetic Inductance Detectors

The complex conductivity of a superconducting thin film is related to the quasiparticle density, which depends on the physical temperature and can also be modified by external pair breaking with photons and phonons. This relationship forms the underlying operating principle of Kinetic Inductance Detectors (KIDs), where the detection threshold is governed by the superconducting energy gap. We investigate the electromagnetic properties of thin-film aluminum that is proximitized with either a normal metal layer of copper or a superconducting layer with a lower T-C, such as iridium, in order to extend the operating range of KIDs. Using the Usadel equations along with the Nam expressions for complex conductivity, we calculate the density of states and the complex conductivity of the resulting bilayers to understand the dependence of the pair breaking threshold, surface impedance, and intrinsic quality factor of superconducting bilayers on the relative film thicknesses. The calculations and analyses provide theoretical insights in designing aluminum-based bilayer kinetic inductance detectors for detection of microwave photons and athermal phonons at the frequencies well below the pair breaking threshold of a pure aluminum film.

complex conductivity↗

Using Quantum Sensors to Probe the Quasiparticle Excess in Quantum Circuits due to Ionizing Radiation

This project quantified natural ionizing radiation as a source of excess quasiparticles in superconducting quantum circuits. Thermal Kinetic Inductance Detectors (TKIDs) were developed and deployed to measure event‑by‑event energy deposition in silicon substrates at millikelvin temperatures. Measurements and radiation transport simulations showed strong agreement across keV–MeV energies, providing validated background models and design guidance to mitigate radiation‑induced decoherence in superconducting qubits and detectors.

97 MATHEMATICS AND COMPUTING↗

BICEP Array: 150 GHz Detector Module Development

The Background Imaging of Cosmic Extragalactic Polarization (BICEP)/Keck (BK) collaboration is currently leading the quest for the highest-sensitivity measurements of the polarized cosmic microwave background (CMB) anisotropies on a degree scale with a series of cryogenic telescopes, of which BICEP Array (BA) is the latest Stage-3 upgrade with a total of ~ 32,000 detectors. The instrument comprises 4 receivers spanning 30–270 GHz, with the low-frequency 30/40 GHz deployed to the South Pole Station in late 2019. The full complement of receivers is forecast to set the most stringent constraints on the tensor-to-scalar ratio r. Building on these advances, the overarching small-aperture telescope concept is already being used as the reference for further Stage-4 experiment design. This paper describes the development of the BICEP Array 150 GHz detector module and its fabrication requirements, with highlights on the high-density time division multiplexing (TDM) design of the cryogenic circuit boards. The low-impedance wiring required between the detectors and the frst stage of superconducting quantum interference device amplifers is crucial to maintaining a stable bias current on the detectors. Here, a novel multilayer FR4 Printed Circuit Board with superconducting traces, capable of reading out up to 648 detectors, is detailed along with its validation tests. An ultra-high-density TDM detector module concept we developed for a CMB-S4-like experiment that allows up to 1920 detectors to be read out is also presented. TDM has been chosen as the detector readout technology for the Cosmic Microwave Background Stage-4 (CMB-S4) experiment based on its proven low-noise performance, predictable costs, and overall maturity of the architecture. The heritage for TDM is rooted in mm- and sub-mm-wave experiments dating back 20 years and has since evolved to support a multiplexing factor of 64x in Stage-3 experiments.

79 ASTRONOMY AND ASTROPHYSICS↗