Search NASA⌕ Search

SEARCH · Search NASA

Results for “Surface assay”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Twisting integrin receptors increases endothelin-1 gene expression in endothelial cells

A magnetic twisting stimulator was developed based on the previously published technique of magnetic twisting cytometry. Using ligand-coated ferromagnetic microbeads, this device can apply mechanical stresses with varying amplitudes, duration, frequencies, and waveforms to specific cell surface receptors. Biochemical and biological responses of the cells to the mechanical stimulation can be assayed. Twisting integrin receptors with RGD (Arg-Gly-Asp)-containing peptide-coated beads increased endothelin-1 (ET-1) gene expression by >100%. In contrast, twisting scavenger receptors with acetylated low-density lipoprotein-coated beads or twisting HLA antigen with anti-HLA antibody-coated beads did not lead to alterations in ET-1 gene expression. In situ hybridization showed that the increase in ET-1 mRNA was localized in the cells that were stressed with the RGD-coated beads. Blocking stretch-activated ion channels with gadolinium, chelating Ca2+ with EGTA, or inhibiting tyrosine phosphorylation with genistein abolished twist-induced ET-1 mRNA elevation. Abolishing cytoskeletal tension with an inhibitor of the myosin ATPase, with an inhibitor of myosin light chain kinase, or with an actin microfilament disrupter blocked twisted-induced increases in ET-1 expression. Our results are consistent with the hypothesis that the molecular structural linkage of integrin-cytoskeleton is an important pathway for stress-induced ET-1 gene expression.

Non-NASA Center↗

Microbial Characterization of Solid-Wastes Treated with Heat Melt Compaction Technology

The research purpose of the project was to determine the fate of microorganisms in space-generated solid wastes after processing by a Heat Melt Compactor (HMC), which is a candidate solid waste treatment technology. Five HMC product disks were generated at Ames Research Center (ARC), Waste Management Systems element. The feed for two was simulated space-generated trash and feed for three was Volume F compartment wet waste returned on STS 130. Conventional microbiological methods were used to detect and enumerate microorganisms in HMC disks and in surface swab samples of HMC hardware before and after operation. Also, biological indicator test strips were added to the STS trash prior to compaction to test if HMC processing conditions, 150 C for approx 3 hr and dehydration, were sufficient to eliminate the test bacteria on the strips. During sample acquisition at KSC, the HMC disk surfaces were sanitized with 70% alcohol to prevent contamination of disk interiors. Results from microbiological assays indicated that numbers of microbes were greatly reduced but not eliminated by the 70% alcohol. Ten 1.25 cm diameter cores were aseptically cut from each disk to sample the disk interior. The core material was run through the microbial characterization analyses after dispersal in sterile diluent. Low counts of viable bacteria (5 to 50 per core) were found but total direct counts were 6 to 8 orders of magnitude greater. These results indicate that the HMC operating conditions might not be sufficient for complete waste sterilization, but the vast majority of microbes present in the wastes were dead or non-cultivable after HMC treatment. The results obtained from analyses of the commercial spore test strips that had been added fo the wastes prior to HMC operation further indicated that the HMC was sterilizing the wastes. Nearly all strips were recovered from the HMC disks and all of these were negative for spore growth when run through the manufacturer's protocol. The 10(exp 6) or so spores impregnated into the strips were no longer viable. Control test strips, i.e., not exposed to the HMC conditions, were all strongly positive. All isolates from the cultivable counts were identified, leading to one concern: several were identified as Staphylococcus aureus, a human pathogen. The project reported here provides microbial characterization support to the Waste Management Systems element of the Life Support and Habitation Systems program.

Strayer, Richard F.↗

The BioSensor Instrument Beyond LEIA: a Versatile Platform for Lunar Biology

Introduction: The BioSensor is a deep-space-compatible automated microfluidic culturing instrument. While originally designed to measure the effects of deep space radiation on yeast growth for the BioSentinel mission, it has the potential to host a diverse range of life science experiments with single- and/or multi-celled organisms and can be adapted to interface with a diverse range of platforms in both crewed and uncrewed settings. It is therefore a leading candidate for hosting life sciences experimentation associated with a lunar surface habitat. BioSensor design: The function of the BioSensor is to monitor the growth and metabolic activity of samples in batch fluidic culture, without the need for crew involvement. The current configuration houses organisms in 16 wells within 16 microfluidic cards, accommodating a total of 256 samples, replicates, and controls. Each well has an optical system including three LEDs and a photodiode detector to measure absorbance at three wavelengths, enabling measurement of optical density, color change in dyes such as alamarBlue, and bioproduction of pigmented compounds. Organisms are loaded into fluidic wells and air-dried for storage during integration, launch, and transit, then activated by the introduction of culture medium from storage bags via manifolds that fill one card at a time. Temperature is controlled by individual card heaters, and timing of all activities (fluidics fills, optical measurements, temperatures) is directed by an experiment script. The self-contained BioSensor payload is roughly 4U in volume; with electrical/mechanical/thermal interface, e.g. for operation on ISS or a lunar lander, as well as a linear energy-transfer (LET) charged-particle radiation spectrometer, the entire system is closer to 6U. BioSentinel and LEIA: Flown on the ISS and in a deep-space free flyer for BioSentinel, the BioSensor has been modified for use in the LEIA mission, including improvements to reduce the sensitivity to lengthy launch delays. LEIA will monitor yeast growth in the radiation and reduced-gravity environment of the lunar surface no earlier than 2026, on a CLPS lander [4]. Changes include accommodating additional culture media and an additional LED color for a new biological assay (bioproduction of carotenoids-- dietary antioxidants), as well as modifications to the housing to allow late-load biology changeout and improved isolation between fluidics and electronics. Future prospects: Future work with the BioSensor, beyond LEIA, will include expanding the range and diversity of organisms and assays accommodated. Preliminary work has demonstrated the growth of Arabidopsis seedlings in BioSensor fluidic cards, including optical measurements of growth rate over time. Minor modifications could allow measurement of phenotypes related to photosynthetic capacity in both plants and cyanobacteria. The experimental capabilities of the BioSensor could be dramatically increased by introducing the capability for fluorescence measurements, and/or the design of novel biological assays using luminescence. The BioSensor can also be adapted for new platforms and experiment settings; in addition to free-flyer, ISS, and CLPS lander, a preliminary design concept has been developed for crewed deployment directly to the lunar surface. The instrument could be accommodated inside a lunar habitat, where its automated operation would make it an excellent candidate for experiments from fundamental investigations into the response of organisms to lunar surface conditions to applied-science purposes such as screening engineered strains of various organisms for bioproduction capability.

J A Lee↗

Characterizing the Number of Kinesin Motors Bound to Microtubules in the Gliding Motility Assay Using FLIC Microscopy [Book Chapter]

Intracellular transport by kinesin motors moving along their associated cytoskeletal filaments, microtubules, is essential to many biological processes. This active transport system can be reconstituted in vitro with the surface-adhered motors transporting the microtubules across a planar surface. In this geometry, the kinesin-microtubule system has been used to study active self-assembly, to power microdevices, and to perform analyte detection. Fundamental to these applications is the ability to characterize the interactions between the surface tethered motors and microtubules. Further, Fluorescence Interference Contrast (FLIC) microscopy can illuminate the height of the microtubule above a surface, which, at sufficiently low surface densities of kinesin, also reveals the number, locations, and dynamics of the bound motors.

59 BASIC BIOLOGICAL SCIENCES↗

Total metal, carbon, anion, iron speciation, and sulfide concentrations; Slate River, East River, and Trail Creek surface water and floodplains, Crested Butte, CO; May 2023–August 2023

This data package comprises analytical results and metadata from stream and groundwater samples collected from the Slate River, East River, Trail Creek, and their respective floodplains. This dataset contains five files: (1) a samples file (2023_SFA_Field_samples.csv) that contains site information; (2) a chemical analysis data file (2023_FieldWaterSampleData_IC__ICPOES__ICPMS__TOC__Fe__S_chem_data.csv) that contains sample analysis values; (3) a file-level metadata file (flmd.csv) that lists each file contained in the dataset with associated metadata; (4) a data dictionary file (dd.csv) that contains column/row headers used throughout the files along with definitions, units, and data types; and (5) a methods file (methods.csv) that contains ID, type, description, instrument, and lab information for each method.The samples’ anion concentrations were measured using ion chromatography (IC), total metal concentrations using inductively coupled plasma emission spectrometry (ICP-OES) and inductively coupled plasma mass spectrometry (ICP-MS), non-purgeable organic carbon using total organic carbon (TOC) analysis, dissolved sulfide concentration using methylene blue spectrophotometry, and iron speciation using the ferrozine assay. To support bulk chemical analyses and colloid characterization, samples were collected from multiple depths ranging from the surface to 3.5 meters below ground.Update on 2024-10-18: Updates were made to the 2023_FieldWaterSampleData_IC__ICPOES__ICPMS__TOC__Fe__S_chem_data.csv and dd.csv files to correct units (ppb instead of ppm).

54 ENVIRONMENTAL SCIENCES↗

Epitope topography of agonist antibodies to the checkpoint inhibitory receptor BTLA

B and T lymphocyte attenuator (BTLA) is an attractive target for a new class of therapeutics that attempt to rebalance the immune system by agonizing checkpoint inhibitory receptors (CIRs). Herpesvirus entry mediator (HVEM) binds BTLA in both trans- and cis-orientations. We report here the development and structural characterization of three humanized BTLA agonist antibodies, 22B3, 25F7, and 23C8. We determined the crystal structures of the antibody-BTLA complexes, showing that these antibodies bind distinct and non-overlapping epitopes of BTLA. While all three antibodies activate BTLA, 22B3 mimics HVEM binding to BTLA and shows the strongest agonistic activity in functional cell assays and in an imiquimod-induced mouse model of psoriasis. 22B3 is also capable of modulating HVEM signaling through the BTLA-HVEM cis-interaction. The data obtained from crystal structures, biochemical assays, and functional studies provide a mechanistic model of HVEM and BTLA organization on the cell surface and informed the discovery of a highly active BTLA agonist.

59 BASIC BIOLOGICAL SCIENCES↗

Bats flying through a Y-maze are visually attracted to wind turbine surfaces

Wind energy’s rapid expansion has led to unintended consequences for wildlife, with migratory bats among the species most at risk. The behavioural mechanisms underlying collisions remain poorly understood, but one hypothesis is that bats are attracted to wind turbine structures. Vision is important to bat orientation and obstacle avoidance, yet it has been relatively understudied in the context of bat–turbine interactions. We hypothesize that light reflected off turbine surfaces could attract bats, acting as a sensory pollutant that may increase collision risk. To test whether reflective turbine surfaces elicit attraction, we flew 242 Lasiurus cinereus and 154 Lasionycteris noctivagans through Y-maze assays. Bats were at least twice as likely to fly towards white turbine blade sections compared to less reflective black ones. This attraction intensified when the alternative exit was a dark, empty flyway, with 74% of L. cinereus and 97% of L. noctivagans flying towards the white turbine blade. These findings provide evidence that visual sensory pollutants could underlie bat–turbine interactions, and if so, wind turbines could be ecological traps.

17 WIND ENERGY↗

Embossed Teflon AF Laminate Membrane Microfluidic Diaphragm Valves

A microfluidic system has been designed to survive spaceflight and to function autonomously on the Martian surface. It manipulates microscopic quantities of liquid water and performs chemical analyses on these samples to assay for the presence of molecules associated with past or present living processes. This technology lies at the core of the Urey Instrument, which is scheduled for inclusion on the Pasteur Payload of the ESA ExoMars rover mission in 2013. Fabrication processes have been developed to make the microfabricated Teflon-AF microfluidic diaphragm pumps capable of surviving extreme temperature excursions before and after exposure to liquid water. Two glass wafers are etched with features and a continuous Teflon membrane is sandwiched between them (see figure). Single valves are constructed using this geometry. The microfabricated devices are then post processed by heating the assembled device while applying pneumatic pressure to force the Teflon diaphragm against the valve seat while it is softened. After cooling the device, the embossed membrane retains this new shape. This solves previous problems with bubble introduction into the fluid flow where deformations of the membrane at the valve seat occurred during device bonding at elevated temperatures (100-150 C). The use of laminated membranes containing commercial Teflon AF 2400 sheet sandwiched between spun Teflon AF 1600 layers performed best, and were less gas permeable than Teflon AF 1600 membranes on their own. Spinning Teflon AF 1600 solution (6 percent in FLOURINERT(Registered TradeMark) FC40 solvent, 3M Company) at 500 rpm for 1.5 seconds, followed by 1,000 rpm for 3 seconds onto Borofloat glass wafers, results in a 10-micron-thick film of extremely smooth Teflon AF. This spinning process is repeated several times on flat, blank, glass wafers in order to gradually build a thick, smooth membrane. After running this process at least five times, the wafer and Teflon coating are heated under vacuum at 220 C for one hour in order to drive off any residual solvent present in the composite film. After this, a second blank, glass wafer is brought down from above and the stack is held under vacuum at 3 atm mechanical pressure for ten 10 hours.

Willis, Peter↗

The distinction of rock types on the basis of their mass spectra, with special reference to lunar-surface applications

It is shown that the rock types most commonly expected to be encountered on the lunar surface can for the most part be readily distinguished, chemically, by plotting their relative concentrations of Fe, Mg, and Al on a ternary variation diagram. The necessary data for characterizing as unknown as to rock type can be quite easily extracted from complete or partial mass spectra such as may be obtained by means of a robot mass spectrometer on the lunar surface. For most compositions, determination of only two nuclide or element rations will characterize the sample. Fo others, the determination of one additional ratio or comparison with a few standard spectra previously obtained in the laboratory may be necessary to clarify the unknown in terms of the chemistry of the terrestrial or meteoritic equivalents. No quantitative assay of element concentrations is necessary for such a first classification.

LUNAR SURFACE↗

Evaluation of various cleaning methods to remove bacillus spores from spacecraft hardware materials

A detailed study was made of the biological cleaning effectiveness, defined in terms of the ability to remove bacterial spores, of a number of methods used to clean hardware surfaces. Aluminum (Al 6061) and titanium (Ti 6Al-4V) were chosen for the study as they were deemed the two materials most likely to be used in spacecraft extraterrestrial sampler construction. Metal coupons (1 cm x 2.5 cm) were precleaned and inoculated with 5.8 x 10(3) cultivable Bacillus subtilis spores, which are commonly found on spacecraft surfaces and in the assembly environments. The inoculated coupons were subsequently cleaned using: (1) 70% isopropyl alcohol wipe; (2) water wipe; (3) multiple-solvent flight-hardware cleaning procedures used at the Jet Propulsion Laboratory (JPL); (4) Johnson Space Center-developed ultrapure water rinse; and (5) a commercial, semi-aqueous, multiple-solvent (SAMS) cleaning process. The biological cleaning effectiveness was measured by agar plate assay, sterility test (growing in liquid media), and epifluorescent microscopy. None of the cleaning protocols tested completely removed viable spores from the surface of the aluminum. In contrast, titanium was capable of being cleaned to sterility by two methods, the JPL standard and the commercial SAMS cleaning process. Further investigation showed that the passivation step employed in the JPL standard method is an effective surface sterilant on both metals but not compatible with aluminum. It is recommended that titanium (Ti 6Al-4V) be considered superior to aluminum (Al 6061) for use in spacecraft sampling hardware, both for its potential to be cleaned to sterilization and for its ability to withstand the most effective cleaning protocols.

Spores, Bacterial/metabolism↗

Structural and functional insights into the interaction between the bacteriophage T4 DNA processing proteins gp32 and Dda

Abstract Bacteriophage T4 is a classic model system for studying the mechanisms of DNA processing. A key protein in T4 DNA processing is the gp32 single-stranded DNA-binding protein. gp32 has two key functions: it binds cooperatively to single-stranded DNA (ssDNA) to protect it from nucleases and remove regions of secondary structure, and it recruits proteins to initiate DNA processes including replication and repair. Dda is a T4 helicase recruited by gp32, and we purified and crystallized a gp32–Dda–ssDNA complex. The low-resolution structure revealed how the C-terminus of gp32 engages Dda. Analytical ultracentrifugation analyses were consistent with the crystal structure. An optimal Dda binding peptide from the gp32 C-terminus was identified using surface plasmon resonance. The crystal structure of the Dda–peptide complex was consistent with the corresponding interaction in the gp32–Dda–ssDNA structure. A Dda-dependent DNA unwinding assay supported the structural conclusions and confirmed that the bound gp32 sequesters the ssDNA generated by Dda. The structure of the gp32–Dda–ssDNA complex, together with the known structure of the gp32 body, reveals the entire ssDNA binding surface of gp32. gp32–Dda–ssDNA complexes in the crystal are connected by the N-terminal region of one gp32 binding to an adjacent gp32, and this provides key insights into this interaction.

Biochemistry & Molecular Biology↗

Handheld Biosensor for COVID-19 Screening

We have made significant progress toward the development of an integrated nucleic acid amplification system for Autonomous Medical Devices Incorporated (AMDIs) Optikus handheld diagnostic device. In this effort, we developed a set of loop-mediated isothermal amplification (LAMP) primers for SARS-CoV-2 and then demonstrate amplification directly on a surface acoustic wave (SAW) sensor. We built associated hardware and developed a C-code to control the amplification process. The goal of this project was to develop a nucleic amplification assay that is compatible with SAW sensors to enable both nucleic and serological testing in a single handheld diagnostic device. Toward this goal, AMDI is collaborating Sandia National Laboratories to develop a rapid, portable diagnostic screening device that utilizes Sandias unique surface acoustic wave biosensor (SAW) for COVID-19 detection. Previously, the SANDIA- AMDI SAW sensor has successfully detected multiple high-profile bacteria viruses, including Ebola, HIV, Sin Nombre, and Anthrax. Over the last two years, AMDI and SANDIA have significantly improved the sensitivity and detection capability of the SAW biosensor and have also developed a modular hand-held, portable platform called the Optikus, which uses CD microfluidics and handheld instrumentation to automate all sample preparation, reagent introduction, sample delivery, and measurement for a number of different assay targets. We propose to use this platform for the development of a rapid (%3C30 minutes), point-of-care diagnostic test for detection of COVID-19 from nasal swab samples.

47 OTHER INSTRUMENTATION↗

Comprehensive Measurement of Microbial Burden in Nutrient-Deprived Cleanrooms

Spacecraft surfaces that are destined to land on potential life-harboring celestial bodies are required to be rigorously cleaned and continuously monitored for spore bioburden as a proxy for spacecraft cleanliness. The NASA standard spore assay (NSA), used for spacecraft bioburden estimates, specifically measures spores that are cultivable, aerobic, resistant to heat shock, and grow at 30˚C in a nutrient-rich medium. Since the vast majority of microorganisms cannot be cultivated using the NSA assay, it is necessary to utilize state-of-the art molecular techniques to better understand the presence of all viable microorganisms, not just those measured with the NSA. In this study, the nutrient-deprived low biomass cleanrooms, where spacecraft are assembled, were used as a surrogate to spacecraft surfaces to measure the ratio of NSA spores in relation to the total viable microorganism population to compare with a 2006 space studies report that estimates that for every 1 spore there is approximately 50,000 viable organisms. Ninety-eight surface wipe samples were collected from the spacecraft assembly facility (SAF) cleanroom at the Jet Propulsion Laboratory (JPL) over a 6-month period. The samples were processed and analyzed using classical microbiology along with molecular assays. Traditional microbiology plating methods were used to determine the cultivable bacterial, fungal, and spore populations. Molecular assays were used to determine the total organisms (TO, dead and live) and the viable organisms (VO, live). The TO was measured using adenine triphosphate (ATP) and quantitative polymerase chain reaction (qPCR) assays. The VO was measured using internal ATP, propidium monoazide (PMA)-qPCR, and flow cytometry (after staining for viable microorganisms) assays. Based on the results, it was possible to establish a ratio between spore counts and VO for each viability assay. The ATP based spore to VO ratio ranged from 149 – 746 and the bacterial PMA-qPCR assay based ratio ranged from 314 – 1491 VO. The most conservative estimate came from FACS, which estimated the ratio to be 12,091 VO per 1 NSA spore. Since archaeal (<1%) and fungal (~2%) populations were negligible, the spore to VO ratios were based on bacterial population estimates. The most conservative ratio from this study can be used as a replacement for the SSB estimate on nutrient-deprived (oligotrophic) desiccated spacecraft surfaces, to estimate the VO from NSA measurements without utilizing state-of-the art molecular methods that are costly and require more biomass than is typically found of spacecraft surfaces.

Venkateswaran, Kasthuri↗

Self-Assembly Interactions in Magnetite-Coated Cellulose Nanocrystals: Implications for Magnetic Hyperthermia Applications

Magnetic cellulose nanocrystal (MCNC) nanocomposites are promising sustainable and biocompatible platforms for magnetic hyperthermia; however, the molecular mechanisms governing Fe 3 O 4 adsorption and deposition onto CNCs remain poorly understood. Here, sulfated (S-CNC) and TEMPO-oxidized CNCs (T-CNC) were used to prepare nanocomposites at 1:2 and 1:4 CNC:Fe 3 O 4 mass ratios, enabling a systematic evaluation of how surface chemistry and nanoparticle loading dictate interfacial interactions and magneto-colloidal behavior. Bare magnetite nanoparticles were 21 ± 5 nm by TEM but grew to 144 ± 18 in the DLS measurement at pH 7. The S-CNC nanocomposites had hydrodynamic sizes between 144 and 210 nm, not much larger than the 140 nm long CNC rods, suggesting an enhanced dispersion stability compared to Fe3O4 alone. X-ray photoelectron spectroscopy combined with density functional theory revealed that −OH and −COOH groups drive electrostatic adsorption with charge transfer from Fe 3 O 4 to the CNC surface, while T-CNCs showed more favorable adsorption energies and evidence of covalent Fe−O bonding. Vibrating sample magnetometry demonstrated superparamagnetic behavior for all samples, with S-CNC/Fe 3 O 4 1:4 and 1:2 displaying saturation magnetizations of 78 and 77 emu/g-Fe 3 O 4 , close to the 83 emu/g of bare magnetite. The T-CNC composites showed lower (60 and 66 emu/g-Fe3O4) saturation magnetizations. Zero-field-cooled/field-cooled measurements resulted in a blocking temperature of 112 K for all samples, except T-CNC/Fe 3 O 4 1:2 (100 K). Magnetic hyperthermia studies revealed that specific absorption rate (SAR) increased with field strength and Fe 3 O 4 content; however, S-CNC/Fe 3 O 4 (1:2) achieved the highest intrinsic SAR per gram of Fe 3 O 4 (649 W/g-Fe 3 O 4 ) likely due to its anisotropy and fast magnetic relaxation. Cytotoxicity assays confirmed that all nanocomposites were nontoxic toward mammalian cells. These results establish quantitative structure−property relationships between CNC surface chemistry, interfacial bonding mechanisms, and magnetic heating performance, providing a foundation for rational design of biocompatible magnetic nanocomposites for hyperthermia and related applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Elemental and isotopic abundances in the solar wind

The use of collecting foils and lunar material to assay the isotopic composition of the solar wind is reviewed. Arguments are given to show that lunar surface correlated gases are likely to be most useful in studying the history of the solar wind, though the isotopic abundances are thought to give a good approximation to the solar wind composition. The results of the analysis of Surveyor material are also given. The conditions leading to a significant component of the interstellar gas entering the inner solar system are reviewed and suggestions made for experimental searches for this fraction. A critical discussion is given of the different ways in which the basic solar composition could be modified by fractionation taking place between the sun's surface and points of observation such as on the Moon or in interplanetary space. An extended review is made of the relation of isotopic and elemental composition of the interplanetary gas to the dynamic behavior of the solar corona, especially processes leading to fractionation. Lastly, connection is made between the subject of composition, nucleosynthesis and the convective zone of the sun, and processes leading to modification of initial accretion of certain gases on the Earth and Moon.

Geiss, J.↗

Genotypic & Phenotypic Diversity of Microbial Isolates from the Mars Exploration Rovers

Mars-bound rovers such as the Mars Exploration Rover (MER) endure strict planetary protection implementation campaigns to assess bioburden. The objective of this study is to identify cultivable microorganisms isolated by the NASA Standard Assay from spacecraft during pre-launch and evaluate their potential to survive conditions on the Martian surface. Of approximately 350 isolates collected from the MER spacecraft archive, 171 microorganisms were reconstituted for characterization via 16S rRNA fingerprinting. Alignment of 16S sequences revealed high levels of sequence similarity to spore-forming species, overwhelmingly of the genera Bacillus (73.7%) and Paenibacillus (14.0%). Samples underwent phenotype characterization employing multiple carbon sources and ion concentrations in an automated microarray format using the Omnilog system. Working and stock cultures were prepared to address the immediate needs for day-to-day culture utilization and long-term preservation, respectively. Results from this study produced details about the microbes that contaminate surfaces of spacecraft, as well as a preliminary evaluation of a rapid biochemical ID method that also provides a phenotypic assessment of contaminants. The overall outcome of this study will benefit emerging cleaning and sterilization technologies for preventing forward contamination that could negatively impact future life detection or sample return missions.

Mars Exploration Rovers↗

Volatility-resolved chemical characterization of airborne particles

A method and apparatus for evaluating the chemical composition of airborne particles by sequentially collecting and analyzing airborne particles in-situ. The method includes: collecting particles; enlarging the particles through water condensation; accelerating the enlarged particles onto a surface to collect enlarged particles; and analyzing the enlarged particles by: isolating the surface; passing a carrier gas over the surface; heating the surface to thermally desorb collected particles into the carrier gas; transporting this evolved vapor into detectors; and assaying the evolved vapor as a function of a desorption temperature. The apparatus includes: a sample flow inlet; a condensational growth tube; a collection and thermal desorption (CTD) cell; a carrier gas source; a heater coupled to the CTD; one or more gas detectors; and a controller configured to operate valves, the heater, the growth tube, and the CTD cell in at least an in-situ sequential collection mode and analysis mode.

Isaacman-VanWertz, Gabriel↗

Evaluation of antifouling surfaces using a method that employs mussel larvae settlement quantified by machine learning

Antifouling coating development requires extensive performance testing. Coatings that prevent aquatic larval settlement are of interest because many forms of macrofouling begin at the larval stage. However, field testing can be time consuming and poorly controlled. Herein is reported a screening tool, Settlement of Larvae Assay using Mussels (SLAM), for down-selecting materials prior to field testing. The method entails using a dense concentration of mussel larvae that are allowed to settle on submerged test surfaces. Settled larvae are then quantified to provide a measure of antifouling performance. The SLAM test differentiated coatings with only slight differences in formulation. To enable efficient quantification of dense larvae settlement, an automated counting method was developed that combines two analyses: a color thresholding identifies larvae clumps, and a machine learning algorithm identifies non-clumped larvae. Finally, this automated ‘hybrid’ approach rapidly quantifies settled larvae as effectively as manual counting but in a fraction of the time.

Mytilus↗