Search NASA⌕ Search

SEARCH · Search NASA

Results for “Surface sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

TRITIUM UNCERTAINTY ANALYSIS FOR SURFACE WATER SAMPLES AT THE SAVANNAH RIVER SITE

Radiochemical analyses of surface water samples, in the framework of Environmental Monitoring, have associated uncertainties for the radioisotopic results reported. These uncertainty analyses pertain to the tritium results from surface water samples collected at five locations on the Savannah River near the U.S. Department of Energy's Savannah River Site (SRS). Uncertainties can result from the field-sampling routine, can be incurred during transport due to the physical properties of the sample, from equipment limitations, and from the measurement instrumentation used. The uncertainty reported by the SRS in their Annual Site Environmental Report currently considers only the counting uncertainty in the measurements, which is the standard reporting protocol for radioanalytical chemistry results. The focus of this work is to provide an overview of all uncertainty components associated with SRS tritium measurements, estimate the total uncertainty according to ISO 17025, and to propose additional experiments to verify some of the estimated uncertainties. The main uncertainty components discovered and investigated in this paper are tritium absorption or desorption in the sample container, HTO/H{sub 2}O isotopic effect during distillation, pipette volume, and tritium standard uncertainty. The goal is to quantify these uncertainties and to establish a combined uncertainty in order to increase the scientific depth of the SRS Annual Site Environmental Report.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Analysis of Tank 38H (HTF-38-17-52, -53) and Tank 43H (HTF-43-17-54, -55) Samples for Support of the Enrichment Control and Corrosion Control Programs

SRNL analyzed samples from Tank 38H and Tank 43H to support ECP and CCP. The total uranium in the Tank 38H surface sample was 41.3 mg/L while the sub-surface sample was 43.5 mg/L. The Tank 43H samples contained total uranium concentrations of 28.5 mg/L in the surface sample and 28.1 mg/L in the sub-surface sample. The U-235 percentage ranged from 0.62% to 0.63% for the Tank 38H samples and Tank 43H samples. The total uranium and percent U-235 results in the table appear slightly lower than recent Tank 38H and Tank 43H uranium measurements. The plutonium results in the table show a large difference between the surface and sub-surface sample concentrations for Tank 38H. The Tank 43H plutonium results closely match the range of values measured on previous samples. The Cs-137 results for the Tank 38H surface and sub-surface samples show similar concentrations slightly higher than the concentrations measured in recent samples. The Cs-137 results for the two Tank 43H samples also show similar concentrations within the range of values measured on previous samples. The four samples show silicon concentrations somewhat lower than the previous samples with values ranging from 124 to 168 mg/L.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

ARM Carbon Cycle Gases Flasks at SGP Site

Data from flasks are sampled at the Atmospheric Radiation Measurement Program ARM, Southern Great Plains Site and analyzed by the National Oceanic and Atmospheric Administration NOAA, Earth System Research Laboratory ESRL. The SGP site is included in the NOAA Cooperative Global Air Sampling Network. The surface samples are collected from a 60 m tower at the ARM SGP Central Facility, usually once per week in the afternoon. The aircraft samples are collected approximately weekly from a chartered aircraft, and the collection flight path is centered over the tower where the surface samples are collected. The samples are collected by the ARM and LBNL Carbon Project.

54 ENVIRONMENTAL SCIENCES↗

SRS Tank 38H and 43H Supernate Foaming Studies and Tank 38H Reel Tape Solids Characterization

Radioactive waste samples retrieved from Savannah River Site (SRS) Tanks 38H and 43H (concentrate receipt and feed tanks, respectively, for the 2H Evaporator system) were evaluated with regard to their tendency to form foams during air sparging. This work was conducted due to recent processing issues and outages in the evaporator that were believed to have resulted from sample foaming. The samples evaluated for foam formation included supernate collected in April of 2014 (near the time of the evaporator outage) as well as historical samples available within the SRNL shielded cells facility. The April samples included one Tank 43H surface sample (HTF-43-14-42), one Tank 43H sub-surface sample (HTF-43-14-43), and one Tank 38H (HTF-38-14-41) surface sample. In addition, two Tank 43H samples (HTF-43-14-8 and HTF-43-14-9) and one Tank 38H sample (HTF-38-14-6) were also evaluated along with a blended sample of various historical Tank 38H and 43H samples. Characterization results for the April samples are also provided. The composition of the samples was similar to historical evaporator system samples received at SRNL.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Distributed Fiber Optics Measurements of Rock Deformation and Failure in Triaxial Tests

The implementation of distributed strain measurement methods in triaxial and uniaxial tests have demonstrated the development of strain localization, even at early stages. This implies that single point measurement methods are location dependent. The use of distributed methods is required not only to improve the interpreted constitutive parameters obtained from triaxial tests, but also to understand the implications of strain localization in the failure process. Here, this work uses optical fibers in triaxial tests. The developed distributed measurement method was implemented on granite, gabbro, and sandstone samples and tested under different confining pressures, reaching 200 MPa on the granite sample. Using a temporal resolution of 0.25 Hz and 5 mm of spatial resolution, the strain evolution at over 300 locations at the sample surface was measured during testing. When compared to point sensing methods, the use of optical fiber greatly increases the number of measurements at the surface of the sample, and their interpolation provides the entire deformation of the sample surface. In all the tests performed, strain localizations were revealed before failure. A three-dimensional interpretation of a test, combining an optical scan of the sample and the distributed measurements, show good correlation between the fractures and the strain localization.

58 GEOSCIENCES↗

Analysis of Tank 38H (HTF-38-16-80, 81) and Tank 43H (HTF-43-16-82, 83) Samples for Support of the Enrichment Control and Corrosion Control Programs

SRNL analyzed samples from Tank 38H and Tank 43H to support ECP and CCP. The total uranium in the Tank 38H surface sample was 57.6 mg/L, while the sub-surface sample was 106 mg/L. The Tank 43H samples ranged from 50.0 to 51.9 mg/L total uranium. The U-235 percentage was consistent for all four samples at 0.62%. The total uranium and percent U-235 results appear consistent with recent Tank 38H and Tank 43H uranium measurements. The Tank 38H plutonium results show a large difference between the surface and sub-surface sample concentrations and somewhat higher concentrations than previous samples. The Pu-238 concentration is more than forty times higher in the Tank 38H sub-surface sample than the surface sample. The surface and sub-surface Tank 43H samples contain similar plutonium concentrations and are within the range of values measured on previous samples. The four samples analyzed show silicon concentrations somewhat higher than the previous sample with values ranging from 104 to 213 mg/L.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of tank 7 surface supernatant sample (FTF-7-15-26) in support of corrosion control program

This report provides the results of analyses on Savannah River Site Tank 7 surface supernatant liquid sample in support of the Corrosion Control Program (CCP). The measured nitrate, nitrite and free-hydroxide concentrations for the Tank 7 surface sample averaged, 3.74E-01 ± 1.88E-03, 4.17E-01 ± 9.01E-03 and 0.602 ± 0.005 M, respectively. The Tank 7 surface cesium-137, sodium and silicon concentrations were, respectively, 3.99E+08, ± 3.25E+06 dpm/mL, 2.78 M and <3.10 mg/L. The measured aluminum concentration in the Tank 7 surface sample averaged 0.11 M.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

System and method for liquid extraction electrospray-assisted sample transfer to solution for chemical analysis

A system for sampling a surface includes a surface sampling probe comprising a solvent liquid supply conduit and a distal end, and a sample collector for suspending a sample collection liquid adjacent to the distal end of the probe. A first electrode provides a first voltage to solvent liquid at the distal end of the probe. The first voltage produces a field sufficient to generate electrospray plume at the distal end of the probe. A second electrode provides a second voltage and is positioned to produce a plume-directing field sufficient to direct the electrospray droplets and ions to the suspended sample collection liquid. The second voltage is less than the first voltage in absolute value. A voltage supply system supplies the voltages to the first electrode and the second electrode. The first electrode can apply the first voltage directly to the solvent liquid. A method for sampling for a surface is also disclosed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Laser ablation sampling system and method

A method and system for sampling a solid sample material can include the step of mounting the sample material on a support. A sample surface is coated with a surface treatment composition in a dry deposition process. A solvent supply conduit for supplying solvent to the sample surface and a solvent exhaust conduit for withdrawing solvent from the sample surface can be provided. Solvent is flowed from the solvent supply conduit to the surface treatment composition and the sample surface such that the solvent contacts the surface treatment composition. A laser beam is directed from a laser source to the sample and the surface treatment composition. The laser beam will ablate the sample and the surface treatment composition in portions intersected by the laser beam. Ablated sample material enters the solvent liquid and will be transported with the solvent away from the sample surface through the solvent exhaust conduit.

Kertesz, Vilmos↗

Laser ablation sampling system and method

A method and system for sampling a solid sample material can include the step of mounting the sample material on a support. A sample surface is coated with a surface treatment composition in a dry deposition process. A solvent supply conduit for supplying solvent to the sample surface and a solvent exhaust conduit for withdrawing solvent from the sample surface can be provided. Solvent is flowed from the solvent supply conduit to the surface treatment composition and the sample surface such that the solvent contacts the surface treatment composition. A laser beam is directed from a laser source to the sample and the surface treatment composition. The laser beam will ablate the sample and the surface treatment composition in portions intersected by the laser beam. Ablated sample material enters the solvent liquid and will be transported with the solvent away from the sample surface through the solvent exhaust conduit.

Kertesz, Vilmos↗

Analysis of Tank 38H (HTF-38-22-31, -32) and Tank 43H (HTF-43-22-33, -34) Samples for Support of the Enrichment Control and Corrosion Control Programs

SRNL analyzed samples from Tank 38H and Tank 43H to support ECP and CCP. The results indicate the concentrations of most soluble species in the Tank 38H surface sample increased from the previous surface sample. The Tank 38H sub-surface sample shows changes in concentration for soluble species in the solution with some increasing and some decreasing. The current Tank 38H sub-surface sample contains less sludge solids than the previous sample based on visual appearance. The small differences in the concentrations of major components between the Tank 38H surface and sub-surface samples indicate only minimal stratification of solution species within the tank.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Tank 38H (HTF-38-20-7, -8) and tank 43H (HTF-43-20-9, -10) samples for Support of the Enrichment Control and Corrosion Control Programs

SRNL analyzed samples from Tank 38H and Tank 43H to support ECP and CCP. The results indicate the concentrations of most species in the Tank 38H surface sample decreased significantly from the previous surface sample. The Tank 38H sub-surface sample shows only small changes in concentration for most major species in the solution from the previous sample. The large differences in the concentrations of major components between the Tank 38H surface and sub-surface samples indicate significant stratification of solution species within the tank. The Tank 38H sub-surface sample contained a small amount of sludge solids (<1 wt%).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Data Validation Package - April and July 2015 Groundwater and Surface Water Sampling at the Gunnison, Colorado, Processing Site

This event included annual sampling of groundwater and surface water locations at the Gunnison, Colorado, Processing Site. Sampling and analyses were conducted as specified in Sampling and Analysis Plan for U.S. Department of Energy Office of Legacy Management Sites. Samples were collected from 28 monitoring wells, three domestic wells, and six surface locations in April at the processing site as specified in the 2010 Ground Water Compliance Action Plan for the Gunnison, Colorado, Processing Site. Domestic wells 0476 and 0477 were sampled in July because the homes were unoccupied in April, and the wells were not in use. Duplicate samples were collected from locations 0113, 0248, and 0477. One equipment blank was collected during this sampling event. Water levels were measured at all monitoring wells that were sampled. No issues were identified during the data validation process that requires additional action or follow-up.

54 ENVIRONMENTAL SCIENCES↗

Data Validation Package, April and June 2016 Groundwater and Surface Water Sampling at the Gunnison, Colorado, Processing Site, October 2016

This event included annual sampling of groundwater and surface water locations at the Gunnison, Colorado, Processing Site. Sampling and analyses were conducted as specified in Sampling and Analysis Plan for US Department of Energy Office of Legacy Management Sites (LMS/PRO/S04351, continually updated, http://energy.gov/lm/downloads/sampling-and­ analysis-plan-us-department-energy-office-legacy-management-sites). Samples were collected from 28 monitoring wells, three domestic wells, and six surface locations in April at the processing site as specified in the draft 2010 Ground Water Compliance Action Plan for the Gunnison, Colorado, Processing Site. Planned monitoring locations are shown in Attachment 1, Sampling and Analysis Work Order. Domestic wells 0476 and 0477 were sampled in June because the homes were unoccupied in April, and the wells were not in use. Duplicate samples were collected from locations 0126, 0477, and 0780. One equipment blank was collected during this sampling event. Water levels were measured at all monitoring wells that were sampled. See Attachment 2, Trip Reports for additional details. The analytical data and associated qualifiers can be viewed in environmental database reports and are also available for viewing with dynamic mapping via the GEMS (Geospatial Environmental Mapping System) website at http://gems.lm.doe.gov/#. No issues were identified during the data validation process that requires additional action or follow-up. An assessment of anomalous data is included in Attachment 3. Interpretation and presentation of results, including an assessment ofthe natural flushing compliance strategy, will be reported in the upcoming 2016 Verification Monitoring Report. U.S.

54 ENVIRONMENTAL SCIENCES↗

Data Validation Package - June 2016 Groundwater and Surface Water Sampling at the Green River, Utah, Disposal Site

This event included annual sampling of groundwater and surface water locations at the Green River, Utah, Disposal Site. Sampling and analyses were conducted as specified in Sampling and Analysis Plan for US. Department of Energy Office of Legacy Management Sites (LMS/PRO/S04351, continually updated, http://energy.gov/lrnldownloads/sampling-and- analysis-plan-us-department-energy-office-legacy-management-sites). Samples were collected from 15 monitoring wells and two surface locations at the disposal site as specified in the draft 2011 Ground Water Compliance Action Plan for the Green River, Utah, Disposal Site. Planned monitoring locations are shown in Attachment 1, Sampling and Analysis Work Order. A duplicate sample was collected from location 0179. One equipment blank was collected during this sampling event. Water levels were measured at all monitoring wells that were sampled. See Attachment 2, Trip Reports for additional details. The analytical data and associated qualifiers can be viewed in environmental database reports and are also available for viewing with dynamic mapping via the GEMS (Geospatial Environmental Mapping System) website at http://gems.lm.doe.gov/#. No issues were identified during the data validation process that requires additional action or follow-up.

54 ENVIRONMENTAL SCIENCES↗

Reliability of Copper Inverse Opal Surfaces for Extreme-Heat-Flux Micro-Coolers in Low-Global-Warming-Potential Refrigerant R-1233zd Pool Boiling Experiments

This presentation provides a brief snapshot of the InterPACK paper InterPACK2023-113781. The paper explores copper inverse opal (CIO) surface reliability in pool boiling experiments in water and a new, low-global-warming-potential (GWP = 1) hydrofluoroolefin (HFO) refrigerant R-1233zd. The CIO-based structure is intended to develop enhanced two-phase heat transfer surfaces for extreme-heat-flux (approximately 1 kW/cm2) micro-coolers. In this study, a limited number of pool boiling experiments were performed using water and HFO-1233zd fluid, and the reliability of the CIO-based surfaces was evaluated. Critical heat flux (CHF) values in HFO-1233zd at 40 Degrees Celsius to 45 Degrees Celsius saturation temperatures and the corresponding saturation pressures were also measured. The CHF values with the refrigerant are significantly lower compared to those with water, but the refrigerant allows for a wider usable temperature range in the end application of the micro-coolers and is not limited to data centers with controlled ambient conditions. Reliability experiments with CIO surface samples - involving pool boiling with water on the CIO surfaces for approximately 48 hours and with HFO-1233zd for 144 hours - showed no structural degradation of the enhanced surface or any significant performance drop in heat transfer coefficients. The CIO surface samples in water were oxidized, most likely due to the presence of air in water and in the experimental vessel.

critical heat flux↗

Analysis of Tank 38H (HTF-38-19-18, -19) and Tank 43H (HTF-43-19-20, -21) Samples for Support of the Enrichment Control and Corrosion Control Programs

SRNL analyzed samples from Tank 38H and Tank 43H to support ECP and CCP. Overall, the results of the analysis indicate the concentrations of species in the Tank 38H surface sample increased significantly from the previous sample with the sodium concentration increasing from 1.09 M in the previous sample to 3.19 M in the current sample. However, it should be noted that the previous Tank 38H surface sample was very dilute compared with typical Tank 38H samples of the recent past. The Tank 38H sub-surface sample shows a composition fairly similar to the previous sample’s composition. Both the Tank 43H surface and sub-surface samples appear slightly more dilute than the previous samples based on the sodium concentrations. For both Tank 38H and Tank 43H, the subsurface samples appear slightly more concentrated for most species than the surface samples. These results indicate some success in increasing the salt solution concentration and reducing stratification in Tank 38H, but some stratification is still evident in both Tank 38H and Tank 43H.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Tank 38H (HTF-38-20-103, -104) and Tank 43H (HTF-43-20-105, -106) Samples for Support of the Enrichment Control and Corrosion Control Programs

SRNL analyzed samples from Tank 38H and Tank 43H to support ECP and CCP. The results indicate the concentrations of most species in the Tank 38H surface sample decreased from the previous surface sample. The Tank 38H sub-surface sample shows only minor changes in concentration for soluble species in the solution (e.g., Na, Al, Cs-137) but a large drop in concentrations for species typically associated with sludge solids (e.g., U, Pu, Fe, Si) likely because of a decrease in sludge solids from the previous sample. The large differences in the concentrations of major components between the Tank 38H surface and sub-surface samples indicate significant stratification of solution species within the tank.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗