Search NASA⌕ Search

SEARCH · Search NASA

Results for “Surface sampling probe”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Electroreduction of Zirconia Using Embedded Electrodes

Disc-shaped samples of 8 mol.% Y 2 O 3 -stabilized zirconia (YSZ) with two embedded Pt + YSZ circular electrodes and contacting Pt wires were made by sintering in air at 1500°C. In one sample, four Pt probes were embedded for local electric potential measurements. Porous surface Pt electrodes were applied on the two exposed surfaces. The samples were heated in air over a temperature range from 800°C to 900°C. A DC voltage between 1 V and 1.7 V was applied across the surface electrodes and the embedded electrodes with the positive connected to the surface electrodes. Furthermore, this resulted in the formation of black zirconia between the two embedded electrodes by electrochemical pumping out oxygen. In the sample with embedded Pt probes, the local potential was measured as a function of time.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effect of the interaction conditions of the probe of an atomic-force microscope with the n-GaAs surface on the triboelectrization phenomenon

Triboelectrization as a result of the scanning of an atomic-force-microscope probe over an n-GaAs surface in the contact mode is investigated. The dependences of the local potential variation on the scanning rate and the pressing force of the probe are obtained. The results are explained by point-defect formation in the surface layers of samples under the effect of deformation of these layers during probe scanning. The charge localized at these defects in the case of equilibrium changes the potential of surface, which is subject to triboelectrization. It is shown that, for qualitative explanation of the observed dependences, it is necessary to take into account both the generation and annihilation of defects in the region experiencing deformation.

36 MATERIALS SCIENCE↗

System and method for laser assisted sample transfer to solution for chemical analysis

A system and method for laser desorption of an analyte from a specimen and capturing of the analyte in a suspended solvent to form a testing solution are described. The method can include providing a specimen supported by a desorption region of a specimen stage and desorbing an analyte from a target site of the specimen with a laser beam centered at a radiation wavelength (.lamda.). The desorption region is transparent to the radiation wavelength (.lamda.) and the sampling probe and a laser source emitting the laser beam are on opposite sides of a primary surface of the specimen stage. The system can also be arranged where the laser source and the sampling probe are on the same side of a primary surface of the specimen stage. The testing solution can then be analyzed using an analytical instrument or undergo further processing.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Direct measurement of transient electric fields induced by ultrafast pulsed laser irradiation of silicon

We use 30 kV electron pulses to probe transient electric fields above silicon surfaces by pump-probe. Electron beam deflection at 0.29 mm away from the sample surface on the order of 10{sup -2} degrees is measured as a function of time delay and used to measure the local electric fields. The measured field strength and direction change with time; at the pump laser fluence of 67.7 mJ/cm{sup 2}, the maximum field reaches 34 kV/m. We model the transient electric fields based on the propagation of electrons emitted from the Si surface and the percentage of electrons escaping from the surface.

36 MATERIALS SCIENCE↗

Combined Atomic Force Microscope-Based Topographical Imaging and Nanometer Scale Resolved Proximal Probe Thermal Desorption/Electrospray Ionization-Mass Spectrometry

Nanometer scale proximal probe thermal desorption/electrospray ionization mass spectrometry (TD/ESI-MS) was demonstrated for molecular surface sampling of caffeine from a thin film using a 30 nm diameter nano-thermal analysis (nano-TA) probe tip in an atomic force microscope (AFM) coupled via a vapor transfer line and ESI interface to a MS detection platform. Using a probe temperature of 350 C and a spot sampling time of 30 s, conical desorption craters 250 nm in diameter and 100 nm deep were created as shown through subsequent topographical imaging of the surface within the same system. Automated sampling of a 5 x 2 array of spots, with 2 m spacing between spots, and real time selective detection of the desorbed caffeine using tandem mass spectrometry was also demonstrated. Estimated from the crater volume (~2x106 nm3), only about 10 amol (2 fg) of caffeine was liberated from each thermal desorption crater in the thin film. These results illustrate a relatively simple experimental setup and means to acquire in automated fashion sub-micrometer scale spatial sampling resolution and mass spectral detection of materials amenable to TD. The ability to achieve MS-based chemical imaging with 250 nm scale spatial resolution with this system is anticipated.

atomic force microscope↗

Generation and detection of 50 GHz surface acoustic waves by extreme ultraviolet pulses

In this work, we use femtosecond extreme ultraviolet pulses derived from a free electron laser to excite and probe surface acoustic waves (SAWs) on the (001) surface of single crystal SrTiO 3 . SAWs are generated by a pair of 39.9 nm pulses crossed at the sample with the crossing angle defining the SAW wavelength at 84 nm. Detection of SAWs is performed via diffraction of a time-delayed 13.3 nm probe pulse by SAW-induced surface ripples. Despite the low reflectivity of the sample in the extreme ultraviolet range, the reflection mode detection is found to be efficient because of an increase in the diffraction efficiency for shorter wavelengths. We describe a methodology for extracting the SAW attenuation in the presence of a thermal grating, which is based on measuring the decay of oscillations at twice the SAW frequency. The proposed approach can be used to study ultrahigh frequency SAWs in a broad range of materials and will bridge the wave vector gap in surface phonon spectroscopy between Brillouin scattering and He atom scattering.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Probing Systematic Bias in Low-redshift Type Ia Supernova Measurements by Cross Analyzing Surface Brightness and Hubble Residuals

For low-redshift (z < 0.1) SN Ia samples used in several cosmological analyses over the past decade, we probe for systematic bias by looking for correlations between surface brightness (SB) measurements and Hubble residuals (HR). For 292 SNe Ia, we measure SB at the location of the SN Ia from publicly available Pan-STARRS (PS1) images. The Hubble residuals are from two recent measurements with low-z SNe Ia that overlap the PS1 footprint: (1) the DES 3 yr cosmology analysis, with 120 overlapping low-z SNe Ia from the Harvard-Smithsonian Center for Astrophysics surveys and Carnegie Supernova Project, and (2) the PS1 single-telescope analysis, with 172 overlapping low-z SNe Ia from the Foundation Supernova Survey. This study is motivated by previous reports of anomalous inefficiencies and flux scatter for transients on bright galaxies. Here, we compare HR distributions of the bright and faint halves of the SB distribution: the mean HR values differ by ${\rm{\Delta }}\overline{\mathrm{HR}}$ = 0.031 ± 0.018, consistent with no difference at the 2σ level. We also perform a Kolmogorov–Smirnov (KS) test for the bright and faint half HR distributions, and conclude that the two distributions are statistically consistent with a KS p-value of 0.07. However, if future studies with larger data sets find ${\rm{\Delta }}\overline{\mathrm{HR}}\sim 0.03$ with high significance, this difference would be a leading systematic uncertainty in measurements of the dark energy equation of state, w.

79 ASTRONOMY AND ASTROPHYSICS↗

Nanospray Desorption Electrospray Ionization: an Ambient Method for Liquid-Extraction Surface Sampling in Mass Spectrometry

A novel nanospray desorption electrospray ionization (nano-DESI) approach is presented and its analytical applications are demonstrated for trace analysis of complex organic analytes deposited on substrates. In this approach the analyte is probed by a micro-droplet of charged solvent formed at the junction between two capillaries. One primary capillary is used to create and maintain a charged micro-droplet of solvent on the substrate while a second capillary is used to create a self-aspirating nanospray that delivers solvent dissolved analyte to the inlet of a mass spectrometer. This approach enables efficient separation of desorption and ionization events, thus providing better control over transport and ionization of the analyte. In this letter we present the basics of the nano-DESI approach and demonstrate its analytical capabilities. Specifically, we demonstrate significant improvement of the limits of detection and the stability of the signal as compared to the traditional DESI and discuss imaging applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Time-of-Flight Neutron Diffraction (TOF-ND) Analyses of the Composition and Minting of Ancient Judaean “Biblical” Coins

TOF-ND elastic scattering of thermal neutrons offers some important advantages over X-ray diffraction (XRD), X-ray fluorescence (XRF), and metallography for the study of archaeological and numismatic problems. Traditional analytical methods are usually destructive and often probe only the surface. Neutrons deeply penetrate samples, simultaneously giving nondestructive bulk information about the crystal structure, composition, and texture (alignment of crystallites) from which thermomechanical manufacturing processes (e.g., cast, struck, or rolled) may be inferred. An analysis of the metal composition and minting processes used for making ancient Judaean bronze and leaded bronze coins from first century BCE and CE is used as a case study. One of the first ND analyses of the temperature used for striking bronze coins is also presented.

36 MATERIALS SCIENCE↗

Probing off-Hugoniot states in Ta, Cu, and Al to 1000 GPa compression with magnetically driven liner implosions

We report on a new technique for obtaining off-Hugoniot pressure vs. density data for solid metals compressed to extreme pressure by a magnetically driven liner implosion on the Z-machine (Z) at Sandia National Laboratories. In our experiments, the liner comprises inner and outer metal tubes. The inner tube is composed of a sample material (e.g., Ta and Cu) whose compressed state is to be inferred. The outer tube is composed of Al and serves as the current carrying cathode. Another aluminum liner at much larger radius serves as the anode. A shaped current pulse quasi-isentropically compresses the sample as it implodes. The iterative method used to infer pressure vs. density requires two velocity measurements. Photonic Doppler velocimetry probes measure the implosion velocity of the free (inner) surface of the sample material and the explosion velocity of the anode free (outer) surface. These two velocities are used in conjunction with magnetohydrodynamic simulation and mathematical optimization to obtain the current driving the liner implosion, and to infer pressure and density in the sample through maximum compression. This new equation of state calibration technique is illustrated using a simulated experiment with a Cu sample. Monte Carlo uncertainty quantification of synthetic data establishes convergence criteria for experiments. Results are presented from experiments with Al/Ta, Al/Cu, and Al liners. Symmetric liner implosion with quasi-isentropic compression to peak pressure ∼1000 GPa is achieved in all cases. These experiments exhibit unexpectedly softer behavior above 200 GPa, which we conjecture is related to differences in the actual and modeled properties of aluminum.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Machine-to-machine variability of roughness and corrosion in additively manufactured 316L stainless steel

Numerous studies on the corrosion response of metal AM have been conducted. Nonetheless, the specimens being tested are commonly ground or polished to remove the outer as-built surface. If metal AM is truly going to be employed as a transformative technology that can produce complex shapes that do not require traditional machining, then the material needs to be evaluated in the as-built state. The reality is that AM alloys have shown significant inconsistencies regarding as-built surface texture, topology, and residual stress. One metric that has shown significant unpredictability in the literature is the susceptibility to localized corrosion of typically passive alloys, such as stainless steel (SS). There are a large number of studies that have attempted to understand the corrosion response of metal AM materials, but these studies are typically performed on materials that have been printed on a single machine and often mechanically polished to a smooth finish. This study compares the corrosion response of as-built AM, laser-beam powder bed fusion (LB-PBF), 316L SS parts that have been fabricated on five different machines. The majority of this work focused on understanding the susceptibility to localized corrosion of AM metals with respect to machine-dependent variables, namely surface roughness, and build angle. Surface roughness data was collected using scanning white light triangulation, laser scanning confocal microscopy, and coherence scanning interferometry. The results show that there is significant variability (p two-tail < 0.05) in the susceptibility to local corrosion initiation of LB-PBF 316L SS samples built on different machines. Surface oxides were probed with electron dispersive spectroscopy and revealed that variations in local corrosion susceptibility likely arise from differences in the stability of the passive film caused by chemical segregation, unique microstructure, and tortuous roughness features at the as-built surfaces. The variability of roughness and corrosion properties from test samples printed on different machines was corroborated by property measurements performed at five different testing sites, proving reproducibility of the data. Most importantly, this study shows that if the as-built surface layer is removed through grinding or electropolishing the machine-to-machine variation observed in the corrosion susceptibility is reduced.

36 MATERIALS SCIENCE↗

Self-sensing cantilevers with integrated conductive coaxial tips for high-resolution electrical scanning probe metrology

The lateral resolution of many electrical scanning probe techniques is limited by the spatial extent of the electrostatic potential profiles produced by their probes. Conventional unshielded conductive atomic force microscopy probes produce broad potential profiles. Shielded probes could offer higher resolution and easier data interpretation in the study of nanostructures. Electrical scanning probe techniques require a method of locating structures of interest, often by mapping surface topography. As the samples studied with these techniques are often photosensitive, the typical laser measurement of cantilever deflection can excite the sample, causing undesirable changes electrical properties. In this work, we present the design, fabrication, and characterization of probes that integrate coaxial tips for spatially sharp potential profiles with piezoresistors for self-contained, electrical displacement sensing. With the apex 100 nm above the sample surface, the electrostatic potential profile produced by our coaxial tips is more than 2 times narrower than that of unshielded tips with no long tails. In a scan bandwidth of 1 Hz–10 kHz, our probes have a displacement resolution of 2.9 Å at 293 K and 79 Å at 2 K, where the low-temperature performance is limited by amplifier noise. We show scanning gate microscopy images of a quantum point contact obtained with our probes, highlighting the improvement to lateral resolution resulting from the coaxial tip.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Remote Raman - laser induced breakdown spectroscopy (LIBS) geochemical investigation under Venus atmospheric conditions

The extreme Venus surface temperatures ({approx}740 K) and atmospheric pressures ({approx}93 atm) create a challenging environment for surface missions. Scientific investigations capable of Venus geochemical observations must be completed within hours of landing before the lander will be overcome by the harsh atmosphere. A combined remote Raman - LIBS (Laser Induced Breakdown Spectroscopy) instrument is capable of accomplishing the geochemical science goals without the risks associated with collecting samples and bringing them into the lander. Wiens et al. and Sharma et al. demonstrated that both analytical techniques can be integrated into a single instrument capable of planetary missions. The focus of this paper is to explore the capability to probe geologic samples with Raman - LIBS and demonstrate quantitative analysis under Venus surface conditions. Raman and LIBS are highly complementary analytical techniques capable of detecting both the mineralogical and geochemical composition of Venus surface materials. These techniques have the potential to profoundly increase our knowledge of the Venus surface composition, which is currently limited to geochemical data from Soviet Venera and VEGA landers that collectively suggest a surface composition that is primarily tholeiitic basaltic with some potentially more evolved compositions and, in some locations, K-rich trachyandesite. These landers were not equipped to probe the surface mineralogy as can be accomplished with Raman spectroscopy. Based on the observed compositional differences and recognizing the imprecise nature of the existing data, 15 samples were chosen to constitute a Venus-analog suite for this study, including five basalts, two each of andesites, dacites, and sulfates, and single samples of a foidite, trachyandesite, rhyolite, and basaltic trachyandesite under Venus conditions. LIBS data reduction involved generating a partial least squares (PLS) model with a subset of the rock powder standards to quantitatively determine the major elemental abundance of the remaining samples. PLS analysis suggests that the major element compositions can be determined with root mean square errors ca. 5% (absolute) for SiO{sub 2}, Al{sub 2}O{sub 3}, Fe{sub 2}O{sub 3}(total), MgO, and CaO, and ca. 2% or less for TiO{sub 2}, Cr{sub 2}O{sub 3}, MnO, K{sub 2}O, and Na{sub 2}O. Finally, the Raman experiments have been conducted under supercritical CO{sub 2} involving single-mineral and mixed-mineral samples containing talc, olivine, pyroxenes, feldspars, anhydrite, barite, and siderite. The Raman data have shown that the individual minerals can easily be identified individually or in mixtures.

36 MATERIALS SCIENCE↗

Rapid Determination of Uranium Isotopic Abundance from Cotton Swipes: Direct Extraction via a Planar Surface Reader and Coupling to a Microplasma Ionization Source

The collection of solid particulates and liquids from surfaces by the use of cloth swipes is fairly ubiquitous. In such methods, there is a continuous concern regarding the ability to locate and quantitatively sample the analyte species from the material. In this effort, we demonstrate the initial coupling of an Advion Plate Express plate reader to a liquid sampling–atmospheric pressure glow discharge (LS-APGD) microplasma ionization source with an Orbitrap mass spectrometer to perform uranium isotopic analyses of solution residues on cotton swipes. The Plate Express employs a sampling probe head to engage and seal against the swipe surface. Subsequentially, the analyte residues are desorbed and transported within a 2% HNO 3 electrolyte flow to the ionization source. Quantitative recoveries were observed following a single 30 s extraction step, with the absolute mass sampled per extraction being ~100 ng. While the intrasample variability in the analytical responses for triplicate sampling of the same swipe yield ~30% RSD, this lack of precision is offset by the ability to determine isotope ratios for enriched uranium specimens with a precision of better than 10% RSD. Pooled, intersample precision ( n = 9) was found to be <5%RSD across the various sample compositions. Finally, 235 U/ 238 U determinations (ranging from 0.053 to 1.806) were accurate with errors of <10%, absolute. The 234 U- and 236 U-inclusive ratios were determined with similar accuracy in enriched samples. While the driving force for the effort is in the realm of nuclear nonproliferation efforts, the ubiquitous use of cloth swipes across many application areas could benefit from this convenient approach, including the use of versatile, reduced-format mass spectrometer systems.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Strong-coupling quantum dot microscope

Here, we report the development and fabrication of a novel cryogenic instrument, a scanning quantum dot microscope (SQDM), capable of positioning a quantum dot to within tunneling range of a sample surface. The microscope is strong-coupling in the sense that electron wavefunctions in the quantum dot can directly overlap with electron wavefunctions in the sample, in contrast to probes based on electric-field coupling. The SQDM consists of a sharp glass probe with two asymmetric electrodes leading to an aluminum quantum dot at the apex. One electrode is capacitively coupled to the quantum dot, while the other lead is connected to the dot via a tunneling junction. A charge sensing circuit constructed from a high-electron-mobility transistor is attached to the capacitance lead to measure the charge state of the dot. The last key feature of the design is a tilted-apex geometry. This design feature, in conjunction with the capacitive sensing scheme, results in a robust quantum-dot probe capable of operating within angstrom distances of the sample surface while protecting the single tunnel junction responsible for electron transport onto the quantum dot. We demonstrate that our instrument can detect single-electron tunneling events and can also be operated as a standard scanning tunneling microscope capable of nanometer-scale resolution of the surface topography.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Surface studies on aluminized and thermally oxidized superalloy 690 substrates interacted with simulated nuclear waste and sodium borosilicate melt

Aluminized and thermally oxidized Ni-Cr-Fe based superalloy 690 substrates with Al{sub 2}O{sub 3} layer on top have been exposed in nitrate based environment (simulated high level nuclear liquid waste) at 373 K for 216 hours and sodium borosilicate melt at 1248 K for 192 hours. The surfaces of exposed samples have been characterized by using Electron probe micro-analyzer (EPMA). Elemental X-ray mapping on coated specimen that exposed in simulated nuclear waste solution revealed that the surface is enriched with Ni, Cr and Al. X-ray mapping on surface of the specimen that interacted with sodium borosilicate melt indicated that the surface is composed of Al, Fe, Ni and Cr.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Observation of skyrmion bubbles in multilayer [Pt/Co/Cu] n using spin-polarized STM

Magnetic multilayers are a promising platform for storage and logic devices based on skyrmion spin textures, due to the large materials phase space for tuning properties. Epitaxial superlattice structures of [Pt/Co/Cu]n thin films were grown by molecular beam epitaxy at room temperature. Spin-polarized scanning tunneling microscopy (SP-STM) of these samples was used to probe the connection between surface structure and skyrmion morphology with nanoscale spatial resolution. Irregular-shaped skyrmion bubbles were observed, with effective diameters from 20 to 200 nm that are much larger than the nanoscale grain structure of the surface topography. Nucleation, annihilation, and motion of skyrmion bubbles could be driven using the stray field of the ferromagnetic tip in repeated imaging, and spin-polarized current/voltage pulses. Furthermore, our detailed comparison of STM topography and differential conductance images shows that there are no surface defects or inhomogeneities at length scales that could account for the range in skyrmion bubble size or shape observed in the measurements.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effect of secondary electron emission on the plasma sheath

In this experiment, plasma sheath potential profiles are measured over boron nitride walls in argon plasma and the effect of secondary electron emission is observed. Results are compared to a kinetic model. Plasmas are generated with a number density of 3 × 10{sup 12} m{sup −3} at a pressure of 10{sup −4} Torr-Ar, with a 1%–16% fraction of energetic primary electrons. The sheath potential profile at the surface of each sample is measured with emissive probes. The electron number densities and temperatures are measured in the bulk plasma with a planar Langmuir probe. The plasma is non-Maxwellian, with isotropic and directed energetic electron populations from 50 to 200 eV and hot and cold Maxwellian populations from 3.6 to 6.4 eV and 0.3 to 1.3 eV, respectively. Plasma Debye lengths range from 4 to 7 mm and the ion-neutral mean free path is 0.8 m. Sheath thicknesses range from 20 to 50 mm, with the smaller thickness occurring near the critical secondary electron emission yield of the wall material. Measured floating potentials are within 16% of model predictions. Measured sheath potential profiles agree with model predictions within 5 V (∼1 T{sub e}), and in four out of six cases deviate less than the measurement uncertainty of 1 V.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗