Search NASA⌕ Search

SEARCH · Search NASA

Results for “Surgical Instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

74 records · Page 5

Design and testing of ultrasound probe adapters for a robotic imaging platform

Medical imaging-based triage is a critical tool for emergency medicine in both civilian and military settings. Ultrasound imaging can be used to rapidly identify free fluid in abdominal and thoracic cavities which could necessitate immediate surgical intervention. However, proper ultrasound image capture requires a skilled ultrasonography technician who is likely unavailable at the point of injury where resources are limited. Instead, robotics and computer vision technology can simplify image acquisition. As a first step towards this larger goal, here, we focus on the development of prototypes for ultrasound probe securement using a robotics platform. The ability of four probe adapter technologies to precisely capture images at anatomical locations, repeatedly, and with different ultrasound transducer types were evaluated across more than five scoring criteria. Testing demonstrated two of the adapters outperformed the traditional robot gripper and manual image capture, with a compact, rotating design compatible with wireless imaging technology being most suitable for use at the point of injury. Next steps will integrate the robotic platform with computer vision and deep learning image interpretation models to automate image capture and diagnosis. This will lower the skill threshold needed for medical imaging-based triage, enabling this procedure to be available at or near the point of injury.

47 OTHER INSTRUMENTATION↗

Piezoelectric transducer design for a miniaturized injectable acoustic transmitter

Acoustic telemetry has been an important tool in the last 20 years for studying fish survival and migration behaviors during and after dam passage. This technology uses implantable acoustic transmitters as tags to three-dimensionally track the movement of fish. However, the relatively large weights and sizes of commercially available transmitters limit the populations of fish that could be studied. The surgical implantation procedures required may also injure fish and also incur a significant amount of labor. Therefore, a smaller, lighter, and injectable tag was needed, and similar or better acoustic performance and service life over that provided by existing commercial tags was desired. To develop such a small transmitter, a number of technical challenges, including design optimization of the piezoelectric transducer, needed to be overcome. The goal of our efforts to optimize the transducer focused on improving the average source level in the 180° range in which the transmitter was facing the receiving hydrophone, so as to increase the transmitter’s detection probability. This paper reports the techniques that were explored and developed to achieve this goal. We found that a novel off-center tube transducer improved the average source level of the front half of the transducer by 1.5 dB. An acoustic reflector attached to the back of the transducer also improved the source level by 3 dB when the transducer was pointed toward the receiving hydrophone, although the source level on the sides of the transducer was reduced. We found that too small a gap between the transducer and the component placed behind it resulted in distortion of the beam pattern. To overcome that issue, we connected a tuning inductor in series with the transducer to help optimize the source level. Furthermore, the findings and techniques developed in this work contributed to the successful development and implementation of a new injectable transmitter.

42 ENGINEERING↗