Search NASA⌕ Search

SEARCH · Search NASA

Results for “Synchronous machines”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Unintentional Islanding Detection Performance with Mixed DER Types

Most inverters for use in distribution-connected distributed energy resource applications (distributed generation and energy storage) are tested and certified to detect and cease to energize unintentional islands on the electric grid. The requirements for the performance of islanding detection methods are specified in IEEE 1547-2018, and specified conditions for certification- type testing of islanding detection are defined in IEEE 1547.1. Such certification-type testing is designed to ensure a minimum level of confidence that these inverters will not island in field applications. However, individual inverter certification tests do not address interactions between dissimilar inverters or between inverter and synchronous machines that may occur in the field. This work investigates the performance of different inverter island detection methods for these two circumstances that are not addressed by the type testing: 1) combinations of different inverters using different types of islanding detection methods, and 2) combinations of inverters and synchronous generators. The analysis took into consideration voltage and frequency ride- through requirements as specified in IEEE 1547-2018, but did not consider grid support functionality such as voltage or frequency response. While the risk of islanding is low even in these cases, it is often difficult to deal with these scenarios in a simplified interconnection screening process. This type of analysis could provide a basis to establish a practical anti- islanding screening methodology for these complex scenarios, with the goal of reducing the number of required detailed studies. Eight generic Groups of islanding detection behavior are defined, and examples of each are used in the simulations. The results indicate that islanding detection methods lose effectiveness at significantly different rates as the composition of the distributed energy resources (DERs) varies, with some methods remaining highly effective over a wide range of conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Multi-Model Adaptive Kalman Filtering Approach to Power System Dynamic State Estimation

Accurate information about dynamic states (such as rotor angle and speed of a synchronous machine) is important for monitoring and controlling power system rotor-angle stability. In this paper, a multi-model adaptive Kalman filtering (MMAKF) approach is proposed to accurately and robustly estimate power system dynamic states. This approach consists of three major steps: (i) multiple Kalman filtering approaches, i.e., the extended Kalman filter (EKF), unscented Kalman filter (UKF), ensemble Kalman filter (EnKF), and cubature Kalman filter (CKF), are run concurrently in parallel to estimate the dynamic states of a synchronous generator using phasor measurement unit data; (ii) probability indexes, which quantify the likelihood of each estimation model, are determined at each time step using hypothesis testing based on the measurement innovation; (iii) the a posteriori estimate of states is obtained using the best-fix approach. The two-area four-machine system is used to evaluate the effectiveness of the proposed MMAKF approach. It is shown through the Monte-Carlo method that the estimation accuracy and robustness of the proposed approach is better than those from any individual filtering algorithm.

multi-model adaptive Kalman Filtering, Power Syste↗

Grid-Following Inverters and Synchronous Condensers: A Grid-Forming Pair?: Preprint

As power systems across the globe continue to achieve higher instantaneous penetrations of power electronic converterinterfaced renewable sources, the stability of these power systems is challenged because of the removal of synchronous machines, from which stability is traditionally derived. Although technological solutions to these stability challenges are on the horizon, such as the use of grid-forming inverters, they are not yet widely applied to larger power systems, which presents operational challenges for power systems achieving these high instantaneous penetrations today. An interim solution using existing technologies is to pair synchronous condensers with grid-following inverters, which might prolong the stability of an operating power system while synchronous generators are turned off during periods of high renewable energy availability. This work examines the transient stability of such a solution using PSCAD simulations of a two-bus system coupled to a variedlength transmission line, with a synchronous condenser at one bus and a grid-following inverter with grid-support functionality at the other. The system is exposed to load step, balanced fault, and unbalanced fault perturbations. It was found that this simple system returned to a steady state for transmission line lengths up to 125 km after 10% load steps, or a variety of fault types.

14 SOLAR ENERGY↗

Grid-Following Inverters and Synchronous Condensers: A Grid-Forming Pair?

As power systems across the globe continue to achieve higher instantaneous penetrations of power electronic converter-interfaced renewable sources, the stability of these power systems is challenged because of the removal of synchronous machines, from which stability is traditionally derived. Although technological solutions to these stability challenges are on the horizon, such as the use of grid-forming inverters, they are not yet widely applied to larger power systems, which presents operational challenges for power systems achieving these high instantaneous penetrations today. A potential interim solution using existing technologies is to pair synchronous condensers with grid-following inverters, which might prolong the stability of an operating power system while synchronous generators are turned off during periods of high renewable energy availability. This work examines the transient stability of such a solution using PSCAD simulations of a two-bus system coupled to a varied-length transmission line, with a synchronous condenser at one bus and a grid-following inverter with grid-support functionality at the other. The system is exposed to load step, balanced fault, and unbalanced fault perturbations. It was found that this simple system returned to a steady state for transmission line lengths up to 125 km after 10% load steps, or a variety of fault types.

grid-following inverters↗

Eddy Current Loss Model Unifying the Effects of Reaction Field and Non-Homogeneous 3-D Magnetic Field

In this article, a new analytical method is proposed to estimate eddy currents inside linear conductive materials. The novel closed-form formulation takes into account the effects of both conductor reaction field that dominates at high frequencies as well as the spatially non-homogeneous nature of the magnetic field penetrating the material. Although the model is suitable for most kinds of permanent magnet machines, it is particularly useful for Surface-mounted Permanent Magnet (SPM) machines where both of these phenomena are prominent. The numerical implementation of the proposed model, which consists of a combination of the method of images and 4-D Fourier transform, is presented. The model is then validated against 2-D and 3-D finite element models (FEMs) for a simple magnetic circuit, showing good agreement. Finally, the eddy current magnet loss in an SPM synchronous machine is evaluated and results are discussed.

Sahu, Raj↗

A Generic Primary-Control Model for Grid-Forming Inverters: Towards Interoperable Operation & Control

This paper outlines an architectural vision centered around the notion of interoperability to integrate grid-forming inverter-based resources in large-scale grids. With the underlying principle of interoperability guiding developments, we focus on modeling the characteristics of droop, virtual synchronous machine, and virtual oscillator controls. Emphasis is placed on these three controllers since they are leading grid-forming control candidates and are likely to be commonplace as primary-control schemes in future systems. We show that these controllers can each be considered as instantiations of a more generic model and that all these controllers exhibit similar droop-like relations between pertinent terminal variables in steady state. This commonality between controllers gives interoperability among them such that automatic synchronization, power sharing, and voltage regulation can be achieved. Simulation results validate the models and demonstrate how the steady-state droop characteristics of these control methods can be aligned with the aid of the developed modeling paradigm.

control↗

Multi-Core Microcontroller Hardware In the Loop System for Electric Machine Control

Hardware in the Loop (HIL) is a simulation technique used to reduce the software development cycle and test control systems in a non-destructive environment. This work describes a cost effective HIL simulator on a dual core microcontroller in which one core acts as a controller and the other emulates the system under control. The emulator runs one step per Pulse Width Modulation (PWM) period in real time. To handle the computational burden and prioritize execution of simulation and control tasks, an interrupt-based software architecture with task prioritization has been developed. As a demonstration, the HIL has been implemented on a Texas Instruments TMS320F28379D dual core microcontroller, which emulates a Permanent Magnet Synchronous Machine (PMSM) with resolver feedback. Hardware peripherals are developed and tested concurrently with the control system, providing higher confidence in the software. By using the peripherals in the HIL development, the controller exercises either the HIL emulation or a pin compatible PMSM testbench. To quantify performance and validate the processor based emulator, the HIL results are compared to the preexisting testbench for accuracy benchmarking at no-load and under load for a range of operating points.

33 ADVANCED PROPULSION SYSTEMS↗

Grid-forming Control of Single- and Two-Stage Solar PV Systems with Mode Transition

Legacy power systems once dominated by con-ventional synchronous machines are transitioning into systems driven by fast-acting power-electronic converters that integrate renewable resources. The majority of integrated renewables such as PV and wind bring down system inertia and can cause stability issues due to their volatile nature. The state-of-the-art grid-forming (GFM) control is proven to enhance system inertia and stability in low-inertia systems. However, most of the existing GFM inverters are applied for battery systems, which are much more expensive than PV. Motivated by this, in this paper we propose a holistic grid-forming (GFM) control strategy for PV systems without the need of energy storage. The proposed strategy is developed on the secondary level of the grid-forming control that enables the PV inverter to operate smoothly among islanded, synchronization, GFM, and limited grid-forming (LGF) modes. The practical criteria for determining the operation modes are established and implemented based on the grid operation scenarios. Here, the proposed design is successfully validated by case studies with a laboratory prototype using Siemens Software Defined Inverters.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Bulk Power System Dynamics with Varying Levels of Synchronous Generators and Grid-Forming Power Inverters

Inverters using phase-locked loops for control depend on voltages generated by synchronous machines to operate. This might be problematic if much of the conventional generation fleet is displaced by inverters. To solve this problem, grid-forming control for inverters has been proposed as being capable of autonomously regulating grid voltages and frequency. Presently, the performance of bulk power systems with massive penetration of grid-forming inverters has not been thoroughly studied as to elucidate benefits. Hence, this paper presents inverter models with two grid-forming strategies: virtual oscillator control and droop control. The two models are specifically developed to be used in positive-sequence simulation packages and have been implemented in PSLF. The implementations are used to study the performance of bulk power grids incorporating inverters with gridforming capability. Specifically, simulations are conducted on a modified IEEE 39-bus test system and the microWECC test system with varying levels of synchronous and inverter-based generation. The dynamic performance of the tested systems with gridforming inverters during contingency events is better than cases with only synchronous generation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Bulk Power System Dynamics with Varying Levels of Synchronous Generators and Grid-Forming Power Inverters: Preprint

Inverters using phase-locked loops for control depend on voltages generated by synchronous machines to operate. This might be problematic if much of the conventional generation fleet is displaced by inverters. To solve this problem, grid-forming control for inverters has been proposed as being capable of autonomously regulating grid voltages and frequency. Presently, the performance of bulk power systems with massive penetrations of grid-forming inverters has not been thoroughly studied to elucidate benefits. Hence, this paper presents inverter models with two grid-forming strategies: virtual oscillator control and droop control. The two models are specifically developed to be used in positive-sequence simulation packages and have been implemented in PSLF. The implementations are used to study the performance of bulk power grids incorporating inverters with grid-forming capability. Specifically, simulations are conducted on a modified IEEE 39-bus test system and the micro-WECC test system with varying levels of synchronous and inverter-based generation. The dynamic performance of the tested systems with grid-forming inverters during contingency events is better than cases with only synchronous generation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Propulsion Electric Grid Simulator (PEGS) for Future Turboelectric Distributed Propulsion Aircraft

NASA Glenn Research Center, in collaboration with the aerospace industry and academia, has begun the development of technology for a future hybrid-wing body electric airplane with a turboelectric distributed propulsion (TeDP) system. It is essential to design a subscale system to emulate the TeDP power grid, which would enable rapid analysis and demonstration of the proof-of-concept of the TeDP electrical system. This paper describes how small electrical machines with their controllers can emulate all the components in a TeDP power train. The whole system model in Matlab/Simulink was first developed and tested in simulation, and the simulation results showed that system dynamic characteristics could be implemented by using the closed-loop control of the electric motor drive systems. Then we designed a subscale experimental system to emulate the entire power system from the turbine engine to the propulsive fans. Firstly, we built a system to emulate a gas turbine engine driving a generator, consisting of two permanent magnet (PM) motors with brushless motor drives, coupled by a shaft. We programmed the first motor and its drive to mimic the speed-torque characteristic of the gas turbine engine, while the second motor and drive act as a generator and produce a torque load on the first motor. Secondly, we built another system of two PM motors and drives to emulate a motor driving a propulsive fan. We programmed the first motor and drive to emulate a wound-rotor synchronous motor. The propulsive fan was emulated by implementing fan maps and flight conditions into the fourth motor and drive, which produce a torque load on the driving motor. The stator of each PM motor is designed to travel axially to change the coupling between rotor and stator. This feature allows the PM motor to more closely emulate a wound-rotor synchronous machine. These techniques can convert the plain motor system into a unique TeDP power grid emulator that enables real-time simulation performance using hardware-in-the-loop (HIL).

electric power grid emulator↗

A Hybrid-Learning Algorithm for Online Dynamic State Estimation in Multimachine Power Systems

With the increasing penetration of distributed generators in the smart grids, having knowledge of rapid real-time electromechanical dynamic states has become crucial to system stability control. Conventional Supervisory Control and Data Acquisition (SCADA)-based dynamic state estimation (DSE) techniques are limited by the slow sampling rates, while the emerging phasor measurement units (PMUs) technology enables rapid real-time measurements at network nodes. Using generator bus terminal voltages, we propose a hybrid-learning DSE (HL-DSE) algorithm to estimate the synchronous machine rotor angle and speed in real time. The HL-DSE takes the power system model into account and trains neuroestimators with real-time data in an online manner. Compared with traditional DSE methods, the HL-DSE overcomes limitations by using a data-driven approach in conjunction with the physical power system model. The time efficiency, accuracy, convergence, and robustness of the proposed algorithm are tested under noises and fault conditions in both small- and large-scale test systems. Simulation results show that the proposed HL-DSE is much more computationally efficient than widely used Kalman filter (KF)-based methods while maintaining comparable accuracy and robustness. In particular, HL-DSE is over 100 times faster than square-root unscented KF (SR-UKF) and 80 times faster than extended KF (EKF). The advantages and challenges of the HL-DSE are also discussed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

System Modeling and Robust Stability Region Analysis for Multi-inverters Based on VSG

As the number of inverter-interfaced distributed generators (IIDGs) increases, the decrease in the inertia of the microgrid affects the stability of microgrid voltage and current. The virtual synchronous generator (VSG) control method simulates the output characteristics of the synchronous machine to improve the inertia and damping of the microgrid. However, low-frequency oscillations can occur in systems with multi-VSGs connected in parallel, primarily when operating in island mode. Therefore, this article develops the small-signal state-space model for multi-inverters based on VSG and analyses the robust stability region (RSR) of the control parameters. Firstly, an extensible small-signal state-space model is established and simplified in the dq axis, which is a necessary preprocessing for the subsequent stability analysis. Secondly, the guardian map method based on bialternate product operation is constructed, and the RSR is established through translation mapping and rotation mapping. Therefore, the solution of RSR is transformed into the problem of identifying the Hurwitz matrix. Finally, the simulations and experiments verify that the calculated region can ensure stable operation during startup and meet the requirement to suppress low-frequency oscillations. In conclusion, the method of solving RSR proposed in this paper provides a basis for selecting controller parameters in practical engineering.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Parameterization of generic positive sequence models to represent behavior of inverter based resources in low short circuit scenarios

The connection of large inverter based resources (IBR) in transmission systems is often located geographically and electrically far away from load centers. This, coupled with the displacement of synchronous machine plants, results in a reduction of the network short circuit strength at the point of connection. Under these conditions, state-of-the-art positive sequence simulation platforms and models can have difficulties maintaining numerical stability and/or providing an accurate representation of IBR plant dynamic behavior. As a result, computationally heavy time domain electromagnetic transient (EMT) simulations may be required to evaluate these systems. In this paper, a recently developed improved generic positive sequence model is parameterized to provide a representation of IBR behavior in low short circuit networks. Further, comparisons against generic and detailed EMT models demonstrate the suitability of the improved positive sequence model to study practical stability issues experienced with presently in-service plants. Such a model can provide some of the accuracy of an EMT representation with a much lower computational burden. The performance of the positive sequence model is validated against the behavior shown by both open white box and closed black box EMT domain models from around the world.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analytical small-signal stability analysis of low-inertia power system frequency response considering secondary frequency regulation

Modern power systems are increasingly vulnerable to frequency instability as inverter-based resources (IBRs) replace synchronous machines and reduce system rotational inertia. Existing small-signal frequency stability assessment methods are either computationally intensive, relying on simulation-driven approaches, or lack analytical stability regions that explicitly account for secondary frequency response (SFR). This paper introduces new analytical frameworks that enable evaluation small-signal frequency stability while explicitly incorporating tunable IBR and SFR parameters. Using Kharitonov’s theorem with an overbounding approach, explicit small-signal stability criteria are derived. In addition, based on Białas’ criterion and Hurwitz matrix, analytical stability regions are established to reveal feasible design spaces for SFR and IBR parameters tuning. Extensive Matlab/Simulink-based simulations validate the accuracy and computational efficiency of the proposed methods, demonstrating that coordinated tuning of SFR and IBR parameters can substantially enhance system resilience. By bridging analytical rigor with practical tunability, this work provides an analytical framework for assessing small-signal frequency stability in low-inertia grids, supporting the real-time, scalable, and resilient operation of sustainable power systems.

14 SOLAR ENERGY↗

Validation of Phasor-Domain Transmission and Distribution Co-simulation Against Electromagnetic Transient Simulation

The rapid deployment of renewable energy resources has led to the widespread use of power electronics in modern power systems. As these systems transition from being dominated by large synchronous machines to increasingly incorporating inverter-based resources (IBRs), traditional methods are becoming inadequate. Addressing this challenge, this paper introduces a scalable phasor-domain T\&D co-simulation framework based on open-source software. It focuses on the framework's validation against the PSCAD Electromagnetic Transient (EMT) analysis tool. The validation results demonstrate the framework's high-fidelity and a computational time speed-up of 60 to 100 times, marking a pioneering validation effort in T\&D co-simulation research.

Inverter-based resources, co-simulation, Electroma↗

Dynamic security assessment of systems powered only by grid-forming power plants with uncertain dispatch using polynomial vectors

A modern challenge in power engineering is to perform the dynamic security assessment (DSA) of grids that are 100% powered by inverter-based resources (IBRs). Addressing this challenge is difficult because: (i) the dispatch of IBRs can be uncertain as a result of the variability of renewable resources and (ii) they have hard current control limits that cannot be neglected, contrasting synchronous machines. To address this problem, this paper sets forth a framework to conduct DSA of bulk power systems that are 100% powered by grid-forming IBRs. Furthermore, the framework considers that IBR operational conditions are unknown but bounded by a zonotope which is also expressed as a polynomial vector for uncertainty propagation via Dormand–Prince integration. The framework is applied to modified versions of the WSCC 9-bus and IEEE 39-bus grids.

14 SOLAR ENERGY↗