Search NASA⌕ Search

SEARCH · Search NASA

Results for “TABLE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

A New Method for Generating Probability Tables in the Unresolved Resonance Region

One new method for constructing probability tables in the unresolved resonance region (URR) has been developed. This new methodology is an extensive modification of the single-level Breit-Wigner (SLBW) pseudo-resonance pair sequence method commonly used to generate probability tables in the URR. The new method uses a Monte Carlo process to generate many pseudo-resonance sequences by first sampling the average resonance parameter data in the URR and then converting the sampled resonance parameters to the more robust R-matrix limited (RML) format. Furthermore, for each sampled set of pseudo-resonance sequences, the temperature-dependent cross sections are reconstructed on a small grid around the energy of reference using the Reich-Moore formalism and the Leal-Hwang Doppler broadening methodology. We then use the effective cross sections calculated at the energies of reference to construct probability tables in the URR. The RML cross-section reconstruction algorithm has been rigorously tested for a variety of isotopes, including 16 O, 19 F, 35 Cl, 56 Fe, 63 Cu, and 65 Cu. The new URR method also produced normalized cross-section factor probability tables for 238 U that were found to be in agreement with current standards. The modified 238 U probability tables were shown to produce results in excellent agreement with several standard benchmarks, including the IEU-MET-FAST-007 (BIG TEN), IEU-MET-FAST-003, and IEU-COMP-FAST-004 benchmarks.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Emerging inorganic solar cell efficiency tables (Version 1)

Abstract This paper presents the efficiency tables of materials considered as emerging inorganic absorbers for photovoltaic solar cell technologies. The materials collected in these tables are selected based on their progress in recent years, and their demonstrated potential as future photovoltaic absorbers. The first part of the paper consists of the criteria for the inclusion of the different technologies in this paper, the verification means used by the authors, and recommendation for measurement best practices. The second part details the highest world-class certified solar cell efficiencies, and the highest non-certified cases (some independently confirmed). The third part highlights the new entries including the record efficiencies, as well as new materials included in this version of the tables. The final part is dedicated to review a specific aspect of materials research that the authors consider of high relevance for the scientific community. In this version of the Efficiency tables, we are including an overview of the latest progress in theoretical methods for modeling of new photovoltaic absorber materials expected to be synthesized and confirmed in the near future. We hope that this emerging inorganic Solar Cell Efficiency Tables (Version 1) paper, as well as its future versions, will advance the field of emerging photovoltaic solar cells by summarizing the progress to date and outlining the future promising research directions.

14 SOLAR ENERGY↗

SU-E-J-72: Dosimetric Study of Cone-Beam CT-Based Radiation Treatment Planning Using a Patient-Specific Stepwise CT-Density Table

Purpose: To assess dose calculation accuracy of cone-beam CT (CBCT) based treatment plans using a patient-specific stepwise CT-density conversion table in comparison to conventional CT-based treatment plans. Methods: Unlike CT-based treatment planning which use fixed CT-density table, this study used patient-specific CT-density table to minimize the errors in reconstructed mass densities due to the effects of CBCT Hounsfield unit (HU) uncertainties. The patient-specific CT-density table was a stepwise function which maps HUs to only 6 classes of materials with different mass densities: air (0.00121g/cm3), lung (0.26g/cm3), adipose (0.95g/cm3), tissue (1.05 g/cm3), cartilage/bone (1.6g/cm3), and other (3g/cm3). HU thresholds to define different materials were adjusted for each CBCT via best match with the known tissue types in these images. Dose distributions were compared between CT-based plans and CBCT-based plans (IMRT/VMAT) for four types of treatment sites: head and neck (HN), lung, pancreas, and pelvis. For dosimetric comparison, PTV mean dose in both plans were compared. A gamma analysis was also performed to directly compare dosimetry in the two plans. Results: Compared to CT-based plans, the differences for PTV mean dose were 0.1% for pelvis, 1.1% for pancreas, 1.8% for lung, and −2.5% for HN in CBCT-based plans. The gamma passing rate was 99.8% for pelvis, 99.6% for pancreas, and 99.3% for lung with 3%/3mm criteria, and 80.5% for head and neck with 5%/3mm criteria. Different dosimetry accuracy level was observed: 1% for pelvis, 3% for lung and pancreas, and 5% for head and neck. Conclusion: By converting CBCT data to 6 classes of materials for dose calculation, 3% of dose calculation accuracy can be achieved for anatomical sites studied here, except HN which had a 5% accuracy. CBCT-based treatment planning using a patient-specific stepwise CT-density table can facilitate the evaluation of dosimetry changes resulting from variation in patient anatomy.

60 APPLIED LIFE SCIENCES↗

TU-CD-304-01: FEATURED PRESENTATION and BEST IN PHYSICS (THERAPY): Trajectory Modulated Arc Therapy: Development of Novel Arc Delivery Techniques Integrating Dynamic Table Motion for Extended Volume Treatments

Purpose: Integration of coordinated robotic table motion with inversely-planned arc delivery has the potential to resolve table-top delivery limitations of large-field treatments such as Total Body Irradiation (TBI), Total Lymphoid Irradiation (TLI), and Cranial-Spinal Irradiation (CSI). We formulate the foundation for Trajectory Modulated Arc Therapy (TMAT), and using Varian Developer Mode capabilities, experimentally investigate its practical implementation for such techniques. Methods: A MATLAB algorithm was developed for inverse planning optimization of the table motion, MLC positions, and gantry motion under extended-SSD geometry. To maximize the effective field size, delivery trajectories for TMAT TBI were formed with the table rotated at 270° IEC and dropped vertically to 152.5cm SSD. Preliminary testing of algorithm parameters was done through retrospective planning analysis. Robotic delivery was programmed using custom XML scripting on the TrueBeam Developer Mode platform. Final dose was calculated using the Eclipse AAA algorithm. Initial verification of delivery accuracy was measured using OSLDs on a solid water phantom of varying thickness. Results: A comparison of DVH curves demonstrated that dynamic couch motion irradiation was sufficiently approximated by static control points spaced in intervals of less than 2cm. Optimized MLC motion decreased the average lung dose to 68.5% of the prescription dose. The programmed irradiation integrating coordinated table motion was deliverable on a TrueBeam STx linac in 6.7 min. With the couch translating under an open 10cmx20cm field angled at 10°, OSLD measurements along the midline of a solid water phantom at depths of 3, 5, and 9cm were within 3% of the TPS AAA algorithm with an average deviation of 1.2%. Conclusion: A treatment planning and delivery system for Trajectory Modulated Arc Therapy of extended volumes has been established and experimentally demonstrated for TBI. Extension to other treatment techniques such as TLI and CSI is readily achievable through the developed platform. Grant Funding by Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

SU-F-I-37: How Fat Distribution and Table Height Affect Estimates of Patient Size in CT Scanning: A Phantom Study

Purpose: Localizer projection radiographs acquired prior to CT scans are used to estimate patient size, affecting the function of Automatic Tube Current Modulation (ATCM) and hence CTDIvol and SSDE. Due to geometric effects, the projected patient size varies with scanner table height and with the orientation of the localizer (AP versus PA). This study sought to determine if patient size estimates made from localizer scans is affected by variations in fat distribution, specifically when the widest part of the patient is not at the geometric center of the patient. Methods: Lipid gel bolus material was wrapped around an anthropomorphic phantom to simulate two different body mass distributions. The first represented a patient with fairly rigid fat and had a generally oval shape. The second was bell-shaped, representing corpulent patients more susceptible to gravity’s lustful tug. Each phantom configuration was imaged using an AP localizer and then a PA localizer. This was repeated at various scanner table heights. The width of the phantom was measured from the localizer and diagnostic images using in-house software. Results: 1) The projected phantom width varied up to 39% as table height changed.2) At some table heights, the width of the phantom, designed to represent larger patients, exceeded the localizer field of view, resulting in an underestimation of the phantom width.3) The oval-shaped phantom approached a normalized phantom width of 1 at a table height several centimeters lower (AP localizer) or higher (PA localizer) than did the bell-shaped phantom. Conclusion: Accurate estimation of patient size from localizer scans is dependent on patient positioning with respect to scanner isocenter and is limited in large patients. Further, patient size is more accurately measured on projection images if the widest part of the patient, rather than the geometric center of the patient, is positioned at scanner isocenter.

60 APPLIED LIFE SCIENCES↗

SU-F-T-259: GPR Tables for the Estimation of Mid-Plane Dose Using EPID

Purpose: To develop a simple method for estimating the mid-plane dose (MPD) of a patient using Electronic Portal imaging Device (EPID). Methods: A Varian TrueBeam with aSi100 EPID was used in this study. The EPID images were acquired for a 30 cm × 30 cm homogeneous slab phantom and a 30 cm diameter 20 cm thick cylindrical phantom in the continuous dosimetry mode. The acquired EPID images in XIM format were imported into in-house MATLAB program for the data analysis. First, the dosimetric characteristics of EPID were studied for dose-response linearity, dose-rate dependence, and field size dependence. Next, the average pixels values of the EPID images were correlated with the MPD measured by an ionisation chamber for various thicknesses of the slab phantom (8 cm – 30 cm) and for various square field sizes (3×3 cm{sup 2} – 25×25 cm{sup 2} at the isocenter). Look-up tables called as GPR tables were then generated for both SSD and SAD setup by taking the ratio of MPD measured by the ionisation chamber and the corresponding EPID pixel values. The accuracy of the GPR tables was evaluated by varying the field size, phantom thickness, and wedge angles with the slab and cylindrical phantoms. Results: The dose response of EPID was linear from 20 MU to 300 MU. The EPID response for different dose rates from 40 MU/min to 600 MU/min was within ±1%. The difference in the doses from the GPR tables and the doses measured by the ionization chambers were within 2% for slab phantoms, and 3% for the cylindrical phantom for various field sizes, phantom thickness, and wedge angles. Conclusion: GPR tables are a ready reckoner for in-vivo dosimetry and it can be used to quickly estimate the MPD value from the EPID images with an accuracy of ±3% for common clinical treatment. project work funded by Union for International cancer control(UICC) under ICRETT fellowship.

60 APPLIED LIFE SCIENCES↗

SU-F-T-406: Verification of Total Body Irradiation Commissioned MU Lookup Table Accuracy Using Treatment Planning System for Wide Range of Patient Sizes

Purpose: To verify the accuracy of total body irradiation (TBI) measurement commissioning data using the treatment planning system (TPS) for a wide range of patient separations. Methods: Our institution conducts TBI treatments with an 18MV photon beam at 380cm extended SSD using an AP/PA technique. Currently, the monitor units (MU) per field for patient treatments are determined using a lookup table generated from TMR measurements in a water phantom (75 × 41 × 30.5 cm3). The dose prescribed to an umbilicus midline point at spine level is determined based on patient separation, dose/ field and dose rate/MU. One-dimensional heterogeneous dose calculations from Pinnacle TPS were validated with thermoluminescent dosimeters (TLD) placed in an average adult anthropomorphic phantom and also in-vivo on four patients with large separations. Subsequently, twelve patients with various separations (17–47cm) were retrospectively analyzed. Computed tomography (CT) scans were acquired in the left and right decubitus positions from vertex to knee. A treatment plan for each patient was generated. The ratio of the lookup table MU to the heterogeneous TPS MU was compared. Results: TLD Measurements in the anthropomorphic phantom and large TBI patients agreed with Pinnacle calculated dose within 2.8% and 2%, respectively. The heterogeneous calculation compared to the lookup table agreed within 8.1% (ratio range: 1.014–1.081). A trend of reduced accuracy was observed when patient separation increases. Conclusion: The TPS dose calculation accuracy was confirmed by TLD measurements, showing that Pinnacle can model the extended SSD dose without commissioning a special beam model for the extended SSD geometry. The difference between the lookup table and TPS calculation potentially comes from lack of scatter during commissioning when compared to extreme patient sizes. The observed trend suggests the need for development of a correction factor between the lookup table and TPS dose calculations.

60 APPLIED LIFE SCIENCES↗

SU-G-206-11: The Effect of Table Height On CTDIvol and SSDE in CT Scanning: A Phantom Study

Purpose: Localizer projection radiographs acquired prior to CT scans are used to estimate patient size, affecting the function of Automatic Tube Current Modulation (ATCM) and calculation of the Size Specific Dose Estimate (SSDE). Due to geometric effects, the projected patient size varies with scanner table height and with the orientation of the localizer (AP versus PA). Consequently, variations in scanner table height may affect both CTDIvol and the calculated size-corrected dose index (SSDE). This study sought to characterize these effects. Methods: An anthropomorphic phantom was imaged using an AP localizer, followed by a diagnostic scan using ATCM and our institution’s routine abdomen protocol. This was repeated at various scanner table heights, recording the scanner-reported CTDIvol for each diagnostic scan. The width of the phantom was measured from the localizer and diagnostic images using in-house software. The measured phantom width and scanner-reported CTDIvol were used to calculate SSDE. This was repeated using PA localizers followed by diagnostic scans. Results: 1) The localizer-based phantom width varied by up to 54% of the nominal phantom width between minimum and maximum table heights. 2) Changing the table height caused a variation in scanner-reported CTDIvol of a factor greater than 4.6 when using a PA localizer and almost 2 when using an AP localizer. 3) SSDE, calculated from measured phantom size and scanner-reported CTDIvol, varied by a factor of more than 2.8 when using a PA localizer and almost 1.5 when using an AP localizer. Conclusion: Our study demonstrates that off-center patient positioning affects the efficacy of ATCM, more severely when localizers are acquired in the PA rather than AP projection. Further, patient positioning errors can cause a large variation in the calculated SSDE. This hinders interpretation of SSDE for individual patients and aggregate SSDE data when evaluating CT protocols and clinical practices.

60 APPLIED LIFE SCIENCES↗

Evaluation of Runtime Performance for xRage Equations of State Input Settings and Cropped EOS Tables

Using the xRage hydro code with its intrinsic equations of state (EOS) settings does not produce the most accurate representation of the problem due to xRage's internal alterations to the fundamental EOS data. Utilizing EOSPAC with default settings in the hydro code uses the unaltered EOS SESAME data to produce what is considered the most accurate results. However, this setup for the simulation is very computationally inefficient due to xRage's reliance on pressure and temperature as its look-up variables in combination with EOSPAC's use of a rational function interpolator. This report explores the results and performance of running a simulation with the option, within EOSPAC, to invert the table at setup, using a linear or rational interpolator, and using an EOS table cut down to only the region actually sampled in the problem. Air and Deuterium are used as the test materials for the simulations. While using EOS data directly with EOSPAC, the rational interpolator takes about twice as long as the linear one. Additionally, using a windowed EOS table does not show a large increase in performance. An EOS table that has had more energy grid points interpolated and added in by EOSPAC showed more accurate results, suggesting that a more dense EOS table would be more accurate.

97 MATHEMATICS AND COMPUTING↗

Automatically operable self-leveling load table

A self-leveling load table is described which is automatically maintained level by selectively opening and closing solenoid valves for inserting and removing air from chambers under the table. The table is floated in a fluid by nine air chambers beneath the top of the table. These chambers are open at the bottom and four oppositely located chambers are used for leveling the table by having the air increased or decreased by means of a flexible hose. Air bearing pendulums are used for selectively energizing solenoid valves which either apply pressurized air to the chamber or evacuate air from the chamber by means of a vacuum source.

Burch, J. L.↗

Tables of Transition Probabilities and Branching Ratios for Electric Dipole Transitions Between Arbitrary Levels of Hydrogen-Like Atoms

Branching ratios in hydrogen-like atoms due to electric-dipole transitions are tabulated for the initial principal and angular momentum quantum number n, lambda, and final principal and angular momentum quantum numbers n, lambda. In table 1, transition probabilities are given for transitions n, lambda, yields n, where sums have been made with respect to lambda. In this table, 2 or = n' or = 10, o or = lambda' or = n'-1, and 1 or = n or = n'-1. In addition, averages with respect to lambda' and sums with respect to n, and lifetimes are given. In table 2, branching ratios are given for transitions n' lambda' yields ni, where sums have been made with respect to lambda. In these tables, 2 or = n' or = 10, 0 or = lambda', n'-1, and 1 or = n or = n'-1. Averages with respect to lambda' are also given. In table 3, branching ratios are given for transitions n' lambda' yields in lambda, where 1 or = n or = 5, 0 or = lambda or = n-1, n n' or = 15, and 0 or = lambda' or = n(s), where n(s), is the smaller of the two numbers n'-1 and 6. Averages with respect to lambda' are given.

Omidvar, K.↗

The feasibility of thermal inertia mapping for detection of perched water tables in semi-arid irrigated lands

The thermal inertia mapping remote sensing technique is evaluated as a potential method for delineating areas of shallow perched water tables and related salinization problems on a regional basis. This method for detecting shallow water tables is based on the existence of significant differences in soil thermal properties between wet and dry soil profiles. Ground observations were conducted at two different test sites in California along the flight line, with one site located in a perched water table area and the other site in a well drained area. Measurements were taken hourly during a four day period (two days before and two days after the flight) for variables such as radiometric, meteorologic, soil moisture and temperature profiles, and surface characteristics. Results indicate that it is not feasible using present apparent thermal inertia remote sensing techniques to reliably delineate regional patterns of very shallow water tables due to the complex environmental system. However, some features within specific fields which may be directly related to the local presence of shallow water tables, such as differences in evaporative cooling due to soil moisture effects between and within fields, can be detected using the thermal inertia technique.

Ezra, C. E.↗

Table-driven configuration and formatting of telemetry data in the Deep Space Network

With a restructured software architecture for telemetry system control and data processing, the NASA/Deep Space Network (DSN) has substantially improved its ability to accommodate a wide variety of spacecraft in an era of 'better, faster, cheaper'. In the new architecture, the permanent software implements all capabilities needed by any system user, and text tables specify how these capabilities are to be used for each spacecraft. Most changes can now be made rapidly, outside of the traditional software development cycle. The system can be updated to support a new spacecraft through table changes rather than software changes, reducing the implementation, test, and delivery cycle for such a change from three months to three weeks. The mechanical separation of the text table files from the program software, with tables only loaded into memory when that mission is being supported, dramatically reduces the level of regression testing required. The format of each table is a different compromise between ease of human interpretation, efficiency of computer interpretation, and flexibility.

Manning, Evan↗

Track-Level-Compensation Look-Up Table Improves Antenna Pointing Precision

This article presents the improvement of the beam-waveguide antenna pointing accuracy due to the implementation of the track-level-compensation look-up table. It presents the development of the table, from the measurements of the inclinometer tilts to the processing of the measurement data and the determination of the threeaxis alidade rotations. The table consists of three axis rotations of the alidade as a function of the azimuth position. The article also presents the equations to determine the elevation and cross-elevation errors of the antenna as a function of the alidade rotations and the antenna azimuth and elevation positions. The table performance was verified using radio beam pointing data. The pointing error decreased from 4.5 mdeg to 1.4 mdeg in elevation and from 14.5 mdeg to 3.1 mdeg in cross-elevation. I. Introduction The Deep Space Station 25 (DSS 25) antenna shown in Fig. 1 is one of NASA s Deep Space Network beam-waveguide (BWG) antennas. At 34 GHz (Ka-band) operation, it is necessary to be able to track with a pointing accuracy of 2-mdeg root-mean-square (rms). Repeatable pointing errors of several millidegrees of magnitude have been observed during the BWG antenna calibration measurements. The systematic errors of order 4 and lower are eliminated using the antenna pointing model. However, repeatable pointing errors of higher order are out of reach of the model. The most prominent high-order systematic errors are the ones caused by the uneven azimuth track. The track is shown in Fig. 2. Manufacturing and installation tolerances, as well as gaps between the segments of the track, are the sources of the pointing errors that reach over 14-mdeg peak-to-peak magnitude, as reported in [1,2]. This article presents a continuation of the investigations and measurements of the pointing errors caused by the azimuth-track-level unevenness that were presented in [1] and [2], and it presents the implementation results. Track-level-compensation (TLC) look-up tables were created for the DSS 25, DSS 26, DSS 34, and DSS 55 antennas. To date, the most complete and detailed results were obtained for the DSS 25 and DSS 55 antennas. In this article, for brevity of presentation, we present the DSS 25 antenna results only. 1 Communications Ground Systems Section. The research described in this publication was carried out by the Jet Propulsion Laboratory, California Institute of Technology, under a contract with the National Aeronautics and Space Administration.

Gawronski, W.↗

Track Level Compensation Look-up Table Improves Antenna Pointing Precision

The pointing accuracy of the NASA Deep Space Network antennas is significantly impacted by the unevenness of the antenna azimuth track. The track unevenness causes repeatable antenna rotations, and repeatable pointing errors. The paper presents the improvement of the pointing accuracy of the antennas by implementing the track-level-compensation look-up table. The table consists of three axis rotations of the alidade as a function of the azimuth position. The paper presents the development of the table, based on the measurements of the inclinometer tilts, processing the measurement data, and determination of the three-axis alidade rotations from the tilt data. It also presents the determination of the elevation and cross-elevation errors of the antenna as a function of the alidade rotations. The pointing accuracy of the antenna with and without a table was measured using various radio beam pointing techniques. The pointing error decreased when the table was used, from 1.5 mdeg to 1.2 mdeg in elevation, and from 20.4 mdeg to 2.2 mdeg in cross-elevation.

Rotation↗

MIL-HDBK-338-Environmental Conversion Table Correction

In reliability analysis for space launch vehicles, limited data is frequently a challenge due to the pure number of launches. A common solution is to use surrogate historical data of similar components from other industries (military data). The operating environment of the common data may be different from that of the necessary target analysis. The military electronic design handbook (MIL-HDBK-338) has a table for converting Mean Time Between Failure (MTBF) data from one environment to another. However, the table has some discrepancies and rounding of complementary conversions; namely going from environment A to B does not given the same result as going from B to A. This presentation will show the discrepancies in the original conversation table, the greater than expected magnitude, the problem with the updated published table and a suggested corrected table to reference when doing MTBF data environment conversion.

Hark, Frank↗

OPER: Optimality-Guided Embedding Table Parallelization for Large-scale Recommendation Model

With the sharp increasing volume of user data, Deep Learning Recommendation Model (DLRM) becomes an indispensable infrastructure in large technology companies. However, large-scale DLRM on the multi-GPU platform is still inefficient due to unbalanced workload partitioning and intensive inter-GPU communication. To this end, we propose OPER, an OPtimality guided Embedding table placement for large-scale Recommendation model training and inference. OPER explores the potential of mitigating remote memory access latency in DLRM through fine-grained embedding table placement. Specifically, OPER proposes a theoretical modeling that builds up the relationship between EMT placement and the embedding communication latency in both training and inference. OPER proves the NP hardness of finding the optimal embedding table placement and proposes a heuristic algorithm that yields near optimal placement. OPER implements a SHMEM-based embedding table training system and a unified embedding index mapping to support fine-grained embedding table sharding and placement. Comprehensive experiments reveal that OPER achieves on average 3.4× and 5.1× speedup on training and inference respectively over state-of-the-art DLRM frameworks.

Wang, Zheng↗

The AME 2020 atomic mass evaluation (II). Tables, graphs and references*

Abstract This is the second part of the new evaluation of atomic masses, AME2020. Using least-squares adjustments to all evaluated and accepted experimental data, described in Part I, we derived tables with numerical values and graphs which supersede those given in AME2016. The first table presents the recommended atomic mass values and their uncertainties. It is followed by a table of the influences of data on primary nuclides, a table of various reaction and decay energies, and finally, a series of graphs of separation and decay energies. The last section of this paper provides all input data references that were used in the AME2020 and the NUBASE2020 evaluations.

74 ATOMIC AND MOLECULAR PHYSICS↗