Search NASA⌕ Search

SEARCH · Search NASA

Results for “TEMPERATURE INDICATOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Recrystallization driven softening and heating rate dependencies of FeCrAl nuclear fuel cladding during accident transients

A refined understanding of FeCrAl cladding behavior during rapid transients is critical for its potential deployment in light-water reactors. Current assessments focus on transient burst testing metrics such as balloon geometry, burst temperature, and hoop stress, often used as proxies for simpler conventional tensile properties. However, directly correlating isothermal tensile and creep data with accident transient scenarios remains a challenge, although it is essential for high fidelity model development. Recent modeling based on tensile tests up to 800 °C, conducted with both immediate loading and a 10-minute soak, showed that immediate loading better predicts experimental burst temperatures, indicating a thermal softening effect. Building upon this observation, the current study connects transient performance, microstructural evolution, and high-temperature tensile properties by leveraging results from C26M claddings burst tests performed at heating rates of 1–50 °C/s and hoop stresses from 25 to 100 MPa. At 25 MPa, rupture temperatures varied by only 6 °C, but at 100 MPa, the difference reached 116 °C, with faster heating yielding higher burst temperatures. Microstructural analysis identified recrystallization as the primary cause of heating rate-dependent softening, eliminating prior cold-working. In-situ thermomechanical data linked ballooning onset to localized instabilities, similar to ultimate tensile strength behavior in conventional tensile tests. High heating rates correlated with immediate loading tensile data, while lower rates matched soaked data. Furthermore, by linking burst performance to microstructural evolution and tensile properties, this work provides a foundation for more accurate modeling of FeCrAl claddings and potentially other Fe-based materials under accident conditions.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Thermal transport in phase-stabilized lithium zirconate phosphates

The thermal properties of yttrium-stabilized lithium zirconate phosphate [LZP: Li 1+x+y Y x Zr 2-x (PO 4 ) 3 with x = 0.15, -0.2 ≤ y ≤ 0.4 and with x = 0.0, y = 0.0] are presented over a wide temperature range from 30 to 973 K, elucidating the interplay between structural phase transformations and thermal properties in a solid state superionic conducting material. At room temperature, the thermal conductivity decreases by more than 75% as the stoichiometry is changed from lithium deficient to excess and increases with increasing temperature, indicative of defect-mediated transport in the spark plasma sintered materials. The phase transformations and their stabilities are examined by x-ray diffraction and differential scanning calorimetry and indicate that the Y3 + substitution of Zr 4+ is effective in stabilizing the ionically conductive rhombohedral phase over the entire temperature range measured, the mechanism of which is found through ab initio theoretical calculations. Finally, these insights into thermal transport of LZP superionic conductors are valuable as they may be generally applicable for predicting material stability and thermal management in the ceramic electrolyte of future all-solid-state-battery devices.

36 MATERIALS SCIENCE↗

Cathodoluminescence of InP

Cathodoluminescence studies were carried out on p-type InP having carrier concentrations ranging from 7.2 x 10 to the 16th to 7.4 x 10 to the 18th per cu cm in the temperature range of 80-580 K. It was found that low-temperature spectra exhibited peaks at 1.41 and 1.38 eV. These peaks were attributed to band-to-band and band-acceptor transitions, respectively. The dependence of the band-to-band peak on temperature was used to extend knowledge of the temperature dependence of the energy gap of InP to 550 K. It was shown that the half-width of the cathodoluminescence peak can be used for the determination of carrier concentration and carrier-concentration inhomogeneities in the material. The variations of the cathodoluminescence peak height with temperature indicated the possibility of Auger recombination for high carrier concentrations (7.4 x 10 to the 18th per cu cm) at temperatures above 450 K.

Gatos, C. H.↗

Temperature-Dependent Changes in the Normal Albedo of the Lunar Surface at 1064 nm

Over the extreme temperature variations experienced in a single lunar day (∆T≈300 K), particular minerals common to the lunar surface show spectral changes at near-infrared wavelengths in laboratory settings (Singer and Roush, 1985; Roush and Singer, 1986, 1987). Variations in temperature can cause variations in the size and shape of crystallographic sites, which control the position, shape, and depth of crystal field absorptions. At an observation wavelength of 1064 nm, the Lunar Orbiter Laser Altimeter (LOLA) should be highly sensitive to temperature-dependent changes of orthopyroxene. Here we analyze temperature-dependent spectral changes of the lunar surface as measured from orbit by LOLA. We couple LOLA measurements of normal albedo with measurements of surface temperature from the Diviner Lunar Radiometer Experiment, analyzing the maria and highlands terranes between ±50° in 1°x1° spatial bins. We provide the first evidence of temperature-dependent spectral changes on the lunar surface from orbital observations, finding that the majority of the lunar surface between 50°N and 50°S demonstrates a small, yet measurable, negative change in normal albedo at 1064 nm with temperature (-∆R/∆T). The measurable effect is on the order of a few percent change in reflectance per ~80 K, indicating temperature changes do not have a large effect on measurements of albedo at the sensitivity of the LOLA instrument. Stronger -∆R/∆T values tend to be associated with the maria, and regions with elevated orthopyroxene levels. Our results suggest that single-wavelength lasers may be powerful tools for understanding the distribution of particular minerals on the lunar surface.

Ariel N Deutsch↗

Effect of Mg doping on carrier recombination in GaN

Time-resolved photoluminescence measurements have been performed on Mg-doped GaN for Mg concentrations in the low- to mid-10 19 cm -3 . As-grown and annealed (600–675 °C) samples were studied. In the as-grown samples, the nonradiative carrier lifetime was found to be about 200 ps and nearly independent of the Mg concentration. Upon annealing, the carrier lifetimes shorten to ~150 ps but, again, show little dependence on the annealing temperature. The analysis of possible Shockley–Read–Hall recombination centers and their behavior during doping and annealing suggests that the main nonradiative recombination center is the Mg–nitrogen vacancy complex. The weak dependence of the PL decay times on temperature indicates that carrier capture into this center has a very low potential barrier, and the nonradiative recombination dominates even at low temperatures.

36 MATERIALS SCIENCE↗

Water vapor oxidation behaviors of nuclear graphite IG-110 for a postulated accident scenario in high temperature gas-cooled reactors

Water leakage in accidental conditions of high temperature gas-cooled reactors is one of the most critical problems that can compromise the integrity of different nuclear components. In this study, oxidation behaviors of nuclear graphite IG-110 in water ingress accidental conditions were investigated. Mass loss and oxidation rates were evaluated after oxidation tests at temperatures up to 1400 °C in an Ar-20 vol% H 2 O mixed atmosphere. The activation energy decreased from 318.6 to 148.9 kJ/mol with temperature, indicating two different oxidation regimes. The cross-sections of the oxidized samples were systematically characterized. The corresponding logarithmic porosity profiles showed a temperature dependency. Pore formation moved toward near-surface regions with increasing temperature and preferential binder oxidation, with filler particle degradation. Furthermore, oxidant concentration profiles and oxidation depths were estimated using a theoretical model and compared with the experimental results. This work provides important benchmark data and safety analysis guidance for the accident scenario in high temperature gas-cooled reactors.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Predicting fatal heat and humidity using the heat index model

A unique wet-bulb temperature of 35°C is often used as the threshold for human survivability, but recent experiments have shown that a person’s core temperature starts to rise at a wide range of critical wet-bulb temperatures. Here, it is shown that the model underlying the heat index correctly predicts those critical wet-bulb temperatures, explaining 95% of the variance in the values observed in laboratory heat-stress experiments. This is the first time the heat-index model has been validated against physiological data from laboratory experiments. For light and moderate exertion in an indoor setting, the heat index model predicts that the critical wet-bulb temperature ranges from 20 to 32°C, depending on the relative humidity, consistent with experimental results. Furthermore, for the same setting and exertion, the heat index model predicts fatal wet-bulb temperatures ranging from 24 to 37°C. Recent experiments have identified the critical combinations of heat and humidity, in an indoor setting, above which an individual is unable to maintain a standard core temperature, indicating severe heat stress. It is shown here why this state of severe heat stress cannot be predicted using the wet-bulb temperature. Instead, it is shown that the recently extended heat index model can explain nearly all of the variance in the observed critical combinations of temperature and humidity, and can be used to calculate fatal combinations.

59 BASIC BIOLOGICAL SCIENCES↗

Heat Transfer Experiments in the Internal Cooling Passages of a Cooled Radial Turbine Rotor

An experimental study was conducted (1) to experimentally measure, assess and analyze the heat transfer within the internal cooling configuration of a radial turbine rotor blade and (2) to obtain heat transfer data to evaluate and improve computational fluid dynamics (CFD) procedures and turbulent transport models of internal coolant flows. A 1.15 times scale model of the coolant passages within the NASA LERC High Temperature Radial Turbine was designed, fabricated of Lucite and instrumented for transient beat transfer tests using thin film surface thermocouples and liquid crystals to indicate temperatures. Transient heat transfer tests were conducted for Reynolds numbers of one-fourth, one-half, and equal to the operating Reynolds number for the NASA Turbine. Tests were conducted for stationary and rotating conditions with rotation numbers in the range occurring in the NASA Turbine. Results from the experiments showed the heat transfer characteristics within the coolant passage were affected by rotation. In general, the heat transfer increased and decreased on the sides of the straight radial passages with rotation as previously reported from NASA-HOST-sponsored experiments. The heat transfer in the tri-passage axial flow region adjacent to the blade exit was relatively unaffected by rotation. However, the heat transfer on one surface, in the transitional region between the radial inflow passage and axial, constant radius passages, decreased to approximately 20 percent of the values without rotation. Comparisons with previous 3-D numerical studies indicated regions where the heat transfer characteristics agreed and disagreed with the present experiment.

Johnson, B. V.↗

Gas turbine combustor stabilization by heat recirculation

The feasibility of heat recirculation for stabilization of lean mixtures and emission reduction has been studied in detail for a typical aircraft gas turbine combustor. Thermodynamic calculations have indicated temperature and heat recirculation rates for operation of the combustor over a range of combustion zone equivalence ratios and for varying modes of desired engine operation. Calculations indicate the feasibility of stabilizing the combustion zone at equivalence ratios as low as 0.2 with achievable heat recirculation rates. Detailed chemical kinetic calculations suggest that combustor heat release is maintained with reaction completion substantially before the NO forming reactions, even though CO is rapidly oxidized in this same region.

Ganji, A.↗

Masking of the circadian rhythms of heart rate and core temperature by the rest-activity cycle in man

Experiments were conducted to estimate the magnitude of the masking effect produced in humans by alternate periods of physical activity and rest or sleep on the circadian rhythms of heart rate and core temperature. The heart rate, rectal temperature, and nondominant wrist activity were monitored in 12 male subjects during 6 days of normal routine at home and during 6 days of controlled bed-rest regimen. The comparisons of averaged waveforms for the activity, heart rate, and temperature indicated that about 45 percent of the range of the circadian heart rate rhythm during normal routine and about 14 percent of the range of the circadian temperature rhythm were attributable to the effects of activity. The smaller effect of activity on the temperature rhythm may be partially attributable to the fact that core temperature is being more rigorously conserved than heart rate, at least during moderate exercise.

Gander, Philippa H.↗

Thermocouple Testing in Support of the AGR-5/6/7 Experiment

This report documents thermocouple testing performed in IRC Lab C-15 over a period of seven years. This testing supported selection and characterization of the thermocouple set used in the AGR-5/6/7 experiment. The following summary was taken directly from the report. Temperature measurement is a challenging aspect of very high temperature irradiation experiments because commonly used high-temperature commercial thermocouples such as platinum-rhodium (Types S, R, and B) and tungsten-rhenium (Type C), suffer dramatic drift because of neutron-induced transmutation. As a result, these types of thermocouples, which are used routinely for industrial temperature measurements outside of reactors, are used only in very special circumstances for reactor experiments. Conversely, because of their low neutron cross-sections, Type N thermocouples are affected to only a limited extent by neutron irradiation. However, the use of these nickel-based thermocouples is limited when the temperature exceeds 1050°C due to drift arising from minor alloying elements migrating from the thermocouple's metal sheath to the thermoelements. This change in the composition of the thermo-elements results in significant decalibration of the signal. The issues described above were recognized during the early planning stages of the final AGR experiment (designated AGR-5/6/7), and a thermocouple furnace testing program was performed over a seven-year period (2014-2019, 2021) to first select and then characterize the best thermocouple set for the high temperature regions of the AGR-5/6/7 irradiation experiment. The calculated temperature range of the AGR-5/6/7 experiment was 600–1500°C. For temperatures below 1000°C standard Type N thermocouples were deemed adequate. The furnace testing campaign identified two thermocouple types suitable for measuring temperatures above 1000°C, a Mo/Nb thermocouple developed at INL called HTIR-TC, and a Type N thermocouple developed by Cambridge University (called herein Cambridge Type N), which featured a custom high nickel alloy sheath. One of the original goals of the furnace testing program was to identify a thermocouple capable of low drift operation near the peak temperature expected in AGR-5/6/7, i.e., about 1400°C. The HTIR-TC design appeared promising in this regard, however a manufacturing difficulty proved to be a barrier and instead the furnace testing focused on drift performance at 1250°C. The manufacturing difficulty was that the Nb sheaths of the HTIR-TCs experienced extreme embrittlement when heat treated at 1600°C or greater. Heat treatment is needed to stabilize the emf output of this TC type, and the higher the heat treatment temperature the higher the peak temperature of stable operation. Because of the sheath embrittlement the heat treatment temperature had to be lowered to 1450°C resulting in a stable operating temperature of about 1250°C. One of the successes of the furnace testing program was identification of a shortcoming in the heat treatment procedure that had been traditionally used in the production of HTIR-TCs. The shortcoming was that the entire heated length of the HTIR-TC sensor was not being heat treated, but rather only the part of the sensor expected to experience temperatures above 1000°C. The problem manifested itself when the thermocouples were removed from the heat treat furnace and placed in another furnace with a different geometry, their indicated temperatures would be widely scattered, but mostly in the negative direction. The solution was to heat treat the entire heated length of the sensor. Since the deepest immersion depth in the AGR-5/6/7 experiment was about 40 inches, a heat treatment length of 48 inches was used. After this change was implemented, thermocouples which were moved into a new environment with a different temperature profile (i.e., a different furnace), produced accurate temperature measurements. Although assembly of the AGR-5/6/7 experiment was completed in September of 2017 (and irradiation begun in 2018), furnace testing of thermocouples continued in 2018 and 2019. The main purpose of this testing was to establish very long-term drift characteristics of the HTIR and Cambridge Type N thermocouples installed in the experiment. Representative thermocouples from the same lots as those installed in the AGR-5/6/7 experiment were used. Additionally, thermocouples of different designs, (particularly variations on the HTIR-TC design) were "piggy-backed" on this testing program to provide insights for instrumenting future very high temperature irradiation experiments. This two-year testing program demonstrated that HTIR-TCs and Cambridge Type N TCs could operate at 1250°C for up to 10,000 hrs (and in some cases longer) while experiencing negative drifts on the order of 2-4°C/1000 hrs. This performance was considered acceptable given the extreme operating environment the sensors faced.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermal modifications of mesons and energy-energy correlators from real-time simulations of a 𝑈⁡(1) lattice gauge theory

We investigate thermal properties of a 𝑈⁡(1) lattice gauge theory in 1 + 1 dimensions through real-time simulations. We extract the spectral functions directly coupling to the pseudoscalar and scalar mesons, demonstrating the thermal modifications of these states with increasing temperatures. Introducing the notion of energy-flow operators, we quantify the temporal buildup of correlations in the energy flows across the lattice. We demonstrate that energy-energy correlators fail to factorize to products of energy flows, both in the vacuum and at nonzero temperature, indicating the presence of nontrivial correlations in the quantum states. Our results constitute a first real-time ab initio study of bound-state thermal broadening and finite temperature energy-flow correlations in a gauge theory, providing a benchmark for future studies of hadronic matter under extreme conditions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Protist Predation Influences the Temperature Response of Bacterial Communities

Temperature strongly influences microbial community structure and function, in turn contributing to global carbon cycling that can fuel further warming. Recent studies suggest that biotic interactions among microbes may play an important role in determining the temperature responses of these communities. However, how predation regulates these microbiomes under future climates is still poorly understood. Here, we assess whether predation by a key global bacterial consumer—protists—influences the temperature response of the community structure and function of a freshwater microbiome. To do so, we exposed microbial communities to two cosmopolitan protist species—Tetrahymena thermophila and Colpidium sp.—at two different temperatures, in a month-long microcosm experiment. While microbial biomass and respiration increased with temperature due to community shifts, these responses changed over time and in the presence of protists. Protists influenced microbial biomass and respiration rate through direct and indirect effects on bacterial community structure, and predator presence actually reduced microbial respiration at elevated temperature. Indicator species analyses showed that these predator effects were mostly determined by phylum-specific bacterial responses to protist density and cell size. Our study supports previous findings that temperature is an important driver of microbial communities but also demonstrates that the presence of a large predator can mediate these responses to warming.

59 BASIC BIOLOGICAL SCIENCES↗

Effects of acceleration on thermoregulatory responses of unanesthetized rats

An experimental study was carried out to examine the thermoregulatory responses of rats to step changes in ambient temperature during centrifugation. Attention is focused on the analysis of problems as to whether the ability of rats to regulate body temperature during one hour of cold exposure is altered by increasing the acceleration field to 2G, whether prior environmental conditioning can affect the temperature response to the combined stressors of acceleration and cold, and whether the orientation of the animal in the acceleration field modifies the temperature response. The finding that the decline in colonic temperature is accompanied by parallel changes in hypothalamic and spinal cord temperatures indicates that the decreasing heat production with increasing heat loss is an atypical thermoregulatory response of these animals to cooling. Mechanical forces acting on the brain may underline the temperature decrease when inverting the animal during acceleration.

Fuller, C. A.↗

Fatigue behavior of SiC reinforced Ti/6Al-4V/ at 650 C

Axial, low cycle fatigue properties of 25 and 44 fiber vol pct SiC/Ti(6Al-4V) composites, measured at 650 C, were compared with the fatigue properties of unreinforced Ti(6Al-4V) at the same temperature. A prior study of the fatigue behavior of this composite system at room temperature indicated that the SiC fiber reinforcement did not provide the anticipated improvement of fatigue resistance of this alloy. At 650 C, the composite fatigue properties degraded somewhat from those at room temperature. However, these properties degraded more for the unreinforced matrix at 650 C with the result that the composite fatigue strength was two to three times the fatigue strength of the matrix alloy. The reasons for this reversal are discussed in terms of crack initiation at broken fibers and residual matrix stresses.

Bhatt, R. T.↗

Thermal-oxidative Pretreatment and Evaluation of Poly (hexafluoropropene Oxide) Fluids

Two commercial poly(hexafluoropropene oxide) fluids were thermally pretreated at 343 C in pure oxygen. IR and NMR spectra indicate that this pretreatment was effective in removing hydrogen end-capped impurities. Decrease in the quantity of volatile material produced during thermal oxidative decomposition and increase in the thermal decomposition temperature indicated improvement in the stability of the fluids. However, this pretreatment failed to render the fluids completely stable in oxidizing atmospheres at 316 C in the presence of metal alloys.

Paciorek, K. J. L.↗

Boundary Layer Transition Protuberance Tests at NASA JSC Arc-Jet Facility

A series of arc-jet tests in support of the Shuttle Orbiter Boundary Layer Transition flight experiment was conducted in the Channel Nozzle of the NASA Johnson Space Center Atmospheric Reentry Materials and Structures Facility. The boundary layer trip was a protrusion of a certain height and geometry fabricated as part of a 6"x6" tile insert, a special test article made of the Boeing Rigid Insulation tile material and coated with the Reaction Cured Glass used for the bottom fuselage tiles of the Space Shuttle Orbiter. A total of five such tile inserts were manufactured: four with the 0.25-in. trip height, and one with the 0.35-in. trip height. The tile inserts were interchangeably installed in the center of the 24"x24" variable configuration tile array mounted in the 24"x24" test section of the channel nozzle. The objectives of the test series were to demonstrate that the boundary layer trip can safely withstand the Space Shuttle Orbiter flight-like re-entry environments and provide temperature data on the protrusion surface, surfaces of the nearby tiles upstream and downstream of the trip, as well as the bond line between the tiles and the structure. The targeted test environments were defined for the tip of the protrusion, away from the nominal surface of the tile array. The arc jet test conditions were approximated in order to produce the levels of the free stream total enthalpy at the protrusion height similar to those expected in flight. The test articles were instrumented with surface, sidewall and bond line thermocouples. Additionally, Tempilaq temperature-indicating paint was applied to the nominal tiles of the tile array in locations not interfering with the protrusion trip. Five different grades of paint were used that disintegrate at different temperatures between 1500 and 2000 deg F. The intent of using the paint was to gauge the RCG-coated tile surface temperature, as well as determine its usefulness for a flight experiment. This paper provides an overview of the channel nozzle arc jet, test articles and test conditions, as well as the results of the arc-jet tests including the measured temperature response of the test articles, their pre- and post-test surface scans, condition of the thermal paint, and continents on the protrusion tip heating achieved in tests compared to the computational fluid dynamics predictions.

Larin, M. E.↗

Comparison of theoretical and observed 3.55 cm wavelength brightness temperature maps of the full moon

In the present paper, a map of the moon's 3.33-cm thermal emission, constructed from observation data, is compared with a map calculated from a detailed model for regolith properties. In an 'observed minus predicted' difference map, two distinct anomalies, each approximately 2 K warmer than their surroundings, are detected. The anomalies are smaller in areal extent than the maria in which they are located (Tranquillitatis and Imbrium). A preliminary analysis, based on calculations of the effects of model parameters on observed brightness temperature, indicates that the two 'hotspots' can be explained by postulating that they are regions possessing a 30 to 40 percent higher than moon-average opacity and that their profile of physical temperature with depth is not necessarily anomalous. On a global scale, a pattern of 'maria warmer than highlands' is presented which exhibits a brightness temperature contrast of approximately 5 K.

Keihm, S. J.↗