Metabolic and thermal responses of the rat to a helium-oxygen environment.
Rats metabolic and thermal responses to helium- oxygen environment at ambient temperatures indicate little adaptive response
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Rats metabolic and thermal responses to helium- oxygen environment at ambient temperatures indicate little adaptive response
Circulation and temperature fields indices used for studying tropospheric-stratospheric interactions during stratospheric warming at constant pressure levels
Lattice parameter and thermal expansion of AlAs as function of temperature, indicating lattice match at 900 C with GaAs
Mercury planet average dark side temperature indicating top surface layer similarity with moon
Thermode composed of two thin-walled stainless steel hypodermic needles and cooper-constantan thermocouple or small thermistor to indicate temperature at point of perfusion is used to measure brain temperature in animals. Because of relatively small size of thermode, structural damage to brain is minimized.
Molybdenum disulfide in the form of natural crystals or powder has been intercalated at -65 to -70 C with sodium and potassium using the liquid ammonia technique. All intercalated samples were found to show a superconducting transition. A plot of the percent of diamagnetic throw versus temperature indicates the possible existence of two phases in the potassium intercalated molybdenum disulfide. The onset of superconductivity in potassium and sodium intercalated molybdenite powder was found to be approximately 6.2 and approximately 4.5 K, respectively. The observed superconductivity is believed to be due to an increase in electron density as a result of intercalation.
The feasibility of automatically reducing a form of pictorial aerodynamic heating data is discussed. The imagery, depicting the melting history of a thin coat of fusible temperature indicator painted on an aerodynamically heated model, was previously reduced by manual methods. Careful examination of various lighting theories and approaches led to an experimentally verified illumination concept capable of yielding high-quality imagery. Both digital and video image processing techniques were applied to reduction of the data, and it was demonstrated that either method can be used to develop superimposed contours. Mathematical techniques were developed to find the model-to-image and the inverse image-to-model transformation using six conjugate points, and methods were developed using these transformations to determine heating rates on the model surface. A video system was designed which is able to reduce the imagery rapidly, economically and accurately. Costs for this system were estimated. A study plan was outlined whereby the mathematical transformation techniques developed to produce model coordinate heating data could be applied to operational software, and methods were discussed and costs estimated for obtaining the digital information necessary for this software.
The results are presented of a wind tunnel test program to determine aerodynamic heat transfer distributions on delta body and straight body transition models of the space shuttle. Heat transfer rates were determined by the phase-change paint technique on Stycast and RTV models using Tempilag as the surface temperature indicator. The nominal test conditions were: Mach 8, length Reynolds numbers of 5 million and 7.4 million, and angles of attack of 20, 40, and 60 deg. Model details, test conditions, and reduced heat transfer data are included. Data reduction of the phase-change paint photographs was performed by utilizing a new technique.
The results of a wind tunnel test program to determine aerodynamic heat transfer distributions on an orbiter configuration are presented. Heat-transfer rates were determined by the phase change paint technique on 0.013-scale Stycast models using Tempilaq as the surface temperature indicator. The nominal test conditions were; Mach 8, length Reynolds numbers of 6.0 x 1 million and 8.9 x 1 million, and angles of attack from 10 to 50 deg in 10-deg increments. At the higher Reynolds number, data were obtained with and without boundary layer trips. Model details, test conditions, and reduced heat-transfer data are presented. Data reduction of the phase-change paint photographs was performed by utilizing a new technique which is described in the data presentation section.
The results of a wind tunnel test program to determine aerodynamic heat transfer distributions on the McDonnell Douglas Booster configuration are presented. Heat-transfer rates were determined by the phase-change paint technique on 0.009-scale Stycast models using Tempilaq as the surface temperature indicator. The nominal test conditions were; Mach 8, length Reynolds numbers 5 million and 7.3 million, and angles of attack of 40, 50, and 60 deg. At the higher Reynolds number, data were obtained with and without boundary layer trips. Model details, test conditions, and reduced heat-transfer data are presented. Data reduction of the phase-change paint photographs was performed by utilizing a new technique which is described.
A wind tunnel test program to determine aerodynamic heat transfer distributions on the McDonnell-Douglas configurations is reported. The tests were conducted at the Arnold Engineering Development Center (AEDC) in Tunnel B of the von Karman Gas Dynamics Facility (VKF). Heat-transfer rates were determined by the phase-change paint technique on 0.011-scale Stycast models using Tempilaq as the surface temperature indicator. The nominal test conditions were; Mach 8, freestream unit Reynolds numbers of 0.8 x one million, 2.5 x one million, and 3.7 x one million, and angles of attack of -5 deg, 0 deg, +5deg. Model details, test conditions, phase-change paint photographs and reduced heat-transfer coefficients are presented.
A wind tunnel test program to determine aerodynamic interference heating on the North American Rockwell orbiter mated with the General Dynamics Convair booster is discussed. The tests were conducted at the Arnold Engineering Development Center (AEDC) in Tunnel B of the von Karman Gas Dynamics Facility (VKF). The test period was June 1971. Heat-transfer rates were determined by the phase-change paint technique on 0.013-scale Stycast models using Tempilaq as the surface temperature indicator. The nominal test conditions were: Mach 8, free-stream unit length Reynolds numbers of 1.25 x one million and 2.55 x one million angles of attack of -5, 0, +5 deg. Model details, test conditions, phase-change paint photographs and reduced heat-transfer coefficients are presented.
The technique is discussed of the symmetric double-probe which readily lends itself to the in situ measurement of plasma temperature in the ionospheric D-region because it can lead to meaningful results under relatively high collision frequencies where the Langmuir probe has been observed to fail. It is shown that the modification to the original collision-free double-probe theory of Johnson and Malter for the determination of electron temperature is never greater than + or - 12%, with a value of (8 + or - 2)% nominally applicable in the case of D-region diagnostics. This technique was successfully operated on a Nike-Cajun payload flown at mid-day from White Sands, New Mexico to an apogee of 78.5 km. The associated electronics and deployed double-probe configuration are presented, and a current-voltage characteristic collected in the ascent stage at 73.7 km is briefly discussed. The values of electron temperature indicated by the sampled data are approximately 30% higher than those predicted by theory for the anticipated state of thermal equilibrium with the ambient neutrals.
The results of testing an on-line quadrupole gas analyzer system are reported. Gas samples were drawn from the exhaust of a hydrogen-oxygen-nitrogen rocket which simulated the flow composition and dynamics at the combustor exit of a supersonic combustion ramjet engine. System response time of less than 50 milliseconds was demonstrated, with analytical accuracy estimated to be + or - 5 percent. For more complex chemical systems with interfering atom patterns, analysis would be more difficult. A cooled-gas pyrometer probe was evaluated as a total temperature indicator and as the primary mass flow measuring element for the total sample flow rate.
Homogeneous plane-parallel model atmospheres for solar flares have been constructed to approximately simulate observations of flares. The wings of the Ca II lines have been used to derive flare upper photosphere models, which indicate temperature increases of about 100 K over the temperature distribution in the pre-existing facula at a height of 300 km. In the case of flares covering sunspots the temperature rise seems to occur much higher in the atmosphere. We find that with increasing flare importance the heights of the upper chromosphere and transition region occur lower in the solar atmosphere, accounting for the factor of 60-600 increase in pressure in these regions relative to the quiet sun. The Ca II line profiles agree with observations only by assuming a macrovelocity distribution that increases with height. Also, the chromospheric parts of flares appear to be highly inhomogeneous. We show that shock and particle heated flare models do not agree with the observations and propose a thermal response model for flares. In particular, it appears that heating in the photosphere is an essential aspect of flares.
Flexural stress relaxation (FSR) and flexural internal friction (FIF) techniques were employed to measure the time-dependent deformation of boron fibers from -190 to 800 C. The principal specimens were 203 micrometers diameter fibers commercially produced by chemical vapor deposition (CVD) on a 13 micrometer tungsten substrate. The observation of complete creep strain recovery with time and temperature indicated that CVD boron fibers deform flexurally as anelastic solids with no plastic component.
A premixing-prevaporizing fuel system for a gas turbine catalytic combustor has been developed and evaluated. Spatial fuel distribution and degree of vaporization were measured at inlet temperatures up to 800 K and fuel-air ratios of 0.01 and 0.025. The test pressure was 0.5 MPa; velocity was 20 m/sec. Both a multiple-jet cross-stream injector and a splash-groove injector with a 30 deg air swirler exhibited a uniform fuel distribution and a high degree of vaporization with little total pressure drop. Fuel oxidation reactions were observed at the 800 K inlet air temperature, indicating that a different design concept is necessary for application with an automotive gas turbine.
Analytical investigations were conducted to determine preliminary design and operating characteristics of flowing uranium hexafluoride (UF6) gaseous nuclear reactor experiments in which a hybrid core configuration comprised of UF6 gas and a region of solid fuel will be employed. The investigations are part of a planned program to perform a series of experiments of increasing performance, culminating in an approximately 5 MW fissioning uranium plasma experiment. A preliminary design is described for an argon buffer gas confined, UF6 flow loop system for future use in flowing critical experiments. Initial calculations to estimate the operating characteristics of the gaseous fissioning UF6 in a confined flow test at a pressure of 4 atm, indicate temperature increases of approximately 100 and 1000 K in the UF6 may be obtained for total test power levels of 100 kW and 1 MW for test times of 320 and 32 sec, respectively.