Search NASA⌕ Search

SEARCH · Search NASA

Results for “TES, detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Comparing complex impedance and bias step measurements of Simons Observatory transition edge sensors

The Simons Observatory (SO) will perform ground-based observations of the cosmic microwave background (CMB) with several small and large aperture telescopes, each outfitted with thousands to tens of thousands of superconducting aluminum manganese (AlMn) transition-edge sensor bolometers (TESs). In-situ characterization of TES responsivities and effective time constants will be required multiple times each observing-day for calibrating time-streams during CMB map-making. Effective time constants are typically estimated in the field by briefly applying small amplitude square-waves on top of the TES DC biases, and fitting exponential decays in the bolometer response. These so-called “bias step” measurements can be rapidly implemented across entire arrays and therefore are attractive because they take up little observing time. However, individual detector complex impedance measurements, while too slow to implement during observations, can provide a fuller picture of the TES model and a better understanding of its temporal response. Here, we present the results of dark TES characterization of many prototype SO bolometers and compare the effective thermal time constants measured via bias steps to those derived from complex impedance data.

Nicholas F. Cothard↗

Extension of the energy range accessible with a TES using bath temperature variations

The energy range of transition-edge sensor (TES) X-ray microcalorimeters with a multiplexed readout depends upon the width and shape of the TES superconducting transition, and also on the dynamic range of the readout. In many detector systems, the multiplexed readout slew rate capability will be the limiting factor for the energy range. In these cases, if we are willing to accept some energy resolution degradation, we can significantly extend the energy range by increasing the bath temperature of operation, essentially creating a second “extended energy range” mode of operation. For example, if we require the very highest energy resolution up to 7 keV, and wish to optimize the design up to this energy, for some measurements it could be very beneficial to have a mode where we can extend the energy range to 15–20 keV even if some energy resolution is sacrificed. In this paper, we explore the trade-off between dynamic range and energy resolution from changing the bath temperature of the TES. We present measurements of TES resolution and slew rate as a function of bath temperature and compare to numerical simulations.

S Beaumont↗

Optimal Energy Measurement in Nonlinear Systems: An Application of Differential Geometry

Design of TES microcalorimeters requires a tradeoff between resolution and dynamic range. Often, experimenters will require linearity for the highest energy signals, which requires additional heat capacity be added to the detector. This results in a reduction of low energy resolution in the detector. We derive and demonstrate an algorithm that allows operation far into the nonlinear regime with little loss in spectral resolution. We use a least squares optimal filter that varies with photon energy to accommodate the nonlinearity of the detector and the non-stationarity of the noise. The fitting process we use can be seen as an application of differential geometry. This recognition provides a set of well-developed tools to extend our work to more complex situations. The proper calibration of a nonlinear microcalorimeter requires a source with densely spaced narrow lines. A pulsed laser multi-photon source is used here, and is seen to be a powerful tool for allowing us to develop practical systems with significant detector nonlinearity. The combination of our analysis techniques and the multi-photon laser source create a powerful tool for increasing the performance of future TES microcalorimeters.

Nonlinear response↗

Progress Towards Improved Analysis of TES X-ray Data Using Principal Component Analysis

The traditional method of applying a digital optimal filter to measure X-ray pulses from transition-edge sensor (TES) devices does not achieve the best energy resolution when the signals have a highly non-linear response to energy, or the noise is non-stationary during the pulse. We present an implementation of a method to analyze X-ray data from TESs, which is based upon principal component analysis (PCA). Our method separates the X-ray signal pulse into orthogonal components that have the largest variance. We typically recover pulse height, arrival time, differences in pulse shape, and the variation of pulse height with detector temperature. These components can then be combined to form a representation of pulse energy. An added value of this method is that by reporting information on more descriptive parameters (as opposed to a single number representing energy), we generate a much more complete picture of the pulse received. Here we report on progress in developing this technique for future implementation on X-ray telescopes. We used an 55Fe source to characterize Mo/Au TESs. On the same dataset, the PCA method recovers a spectral resolution that is better by a factor of two than achievable with digital optimal filters.

Low-temperature detectors A[center dot] Transition↗

Multi-Absorber Transition-Edge Sensors for X-Ray Astronomy Applications

We are developing multi-absorber Transition-Edge Sensors (TESs) for applications in x-ray astronomy. These position-sensitive devices consist of multiple x-ray absorbers each with a different thermal coupling to a single readout TES. Heat diffusion between the absorbers and the TES gives rise to a characteristic pulse shape corresponding to each absorber element and enables position discrimination. The development of these detectors is motivated by a desire to maximize focal plane arrays with the fewest number of readout channels. In this contribution we report on the first results from devices consisting of nine) 65 X 65 sq. microns Au x-ray absorbers) 5 microns thick. These are coupled to a single 35 X 35 sq. microns Mo/Au bilayer TES. These devices have demonstrated full-width-half-maximum (FWHM) energy resolution of 2.1 eV at 1.5 keV) 2.5 eV at 5.9 keV and 3.3 eV at 8 keV. This is coupled with position discrimination from pulse shape over the same energy range. We use a finite-element model to reproduce the measured pulse shapes and investigate the detector non-linearity with energy) which impacts on the devices position sensitivity and energy resolution.

Smith, S. J.↗

The X-ray Microcalorimeter Spectrometer (XMS): A Reference Cryogenic Instrument Design for Constellation-X

Constellation-X, a mission now belonging to the Beyond Einstein initiative, is being planned to inherit the x-ray sky from Chandra, XMM-Newton and Astro-E. The first two of four observatories in the constellation will be launched together in 2013 and followed a year later by the launch of the remaining two. The four will independently orbit the Sun-Earth Lagrange point L2. An instrument compliment resides in the Focal Plane Module (FPM) of each observatory 10 m from the Optics Module and consists of three Hard X-ray Telescope (HXT) detectors, a Reflection Grating Spectrometer (RGS) focal plane CCD camera and an X-ray Microcalorimeter Spectrometer (XMS). Instrument awards are scheduled for early 2006. The reference detector for XMS is a 32 x 32 array of microcalorimetric superconducting Transition Edge Sensors (TES). Each pixel casts a variable resistance in a SQUID based multiplexed readout circuit which is coupled to series SQUID arrays for amplification and finally read out by external electronics. A multi-stage continuous ADR will provide the stable 50 mK desired for the TES array and a stable 1 K for the series SQUID arrays while also lifting thermal parasitic and inefficiency loads to a 6 K cryocooler interface. The 6 K cryocooler is expected to emerge from the joint-project Advanced Cryocooler Technology Development Program (ACTDP) in which Constellation-X is an active participant. Project Pre-Formulation activities are marked by extensive technology development necessitating early, but realistic, thermal and cooling load requirements for ADR and ACTDP-cryocooler design points. Such requirements are driven by the encompassing XMS cryostat and ultimately by the thermal environment imposed by the FPM. It is further desired that the XMS instrument be able to operate on its side in the laboratory, with a warm vacuum shell, during an extensive calibration regime. It is that reference system design of the XMS instrument (microcalorimeter, ADR, cryocooler and cryostat) which is the subject of this paper.

Whitehouse, Paul L.↗

Advances in Small Pixel TES-Based X-Ray Microcalorimeter Arrays for Solar Physics and Astrophysics

We are developing small-pixel transition-edge-sensor (TES) for solar physics and astrophysics applications. These large format close-packed arrays are fabricated on solid silicon substrates and are designed to accommodate count-rates of up to a few hundred counts/pixel/second at a FWHM energy resolution approximately 2 eV at 6 keV. We have fabricated versions that utilize narrow-line planar and stripline wiring. We present measurements of the performance and uniformity of kilo-pixel arrays, incorporating TESs with single 65-micron absorbers on a 7s-micron pitch, as well as versions with more than one absorber attached to the TES, 4-absorber and 9-absorber "Hydras". We have also fabricated a version of this detector optimized for lower energies and lower count-rate applications. These devices have a lower superconducting transition temperature and are operated just above the 40mK heat sink temperature. This results in a lower heat capacity and low thermal conductance to the heat sink. With individual single pixels of this type we have achieved a FWHM energy resolution of 0.9 eV with 1.5 keV Al K x-rays, to our knowledge the first x-ray microcalorimeter with sub-eV energy resolution. The 4-absorber and 9-absorber versions of this type achieved FWHM energy resolutions of 1.4 eV and 2.1 eV at 1.5 keV respectively. We will discuss the application of these devices for new astrophysics mission concepts.

Bandler, S. R.↗

The Simons Observatory Microwave SQUID Multiplexing Detector Module Design

Advances in cosmic microwave background(CMB)science depend on increasing the number of sensitive detectorsobserving the sky. New instruments deploy large arrays of superconducting transition-edge sensor(TES)bolometers tileddensely into ever larger focal planes. High multiplexing factors reduce the thermal loading on the cryogenic receivers andsimplify their design. We present the design of focal-plane modules with an order of magnitude higher multiplexingfactor than has previously been achieved with TES bolometers. We focus on the novel cold readout component, whichemploys microwave SQUID multiplexing(μmux). Simons Observatory will use 49 modules containing 70,000bolometers to make exquisitely sensitive measurements of the CMB. We validate the focal-plane module design,presenting measurements of the readout component with and without a prototype detector array of 1728 polarization-sensitive bolometers coupled to feedhorns. The readout component achieves a 95% yield and a 910 multiplexing factor.The median white noise of each readout channel is 65pA Hz. This impacts the projected SO mapping speed by<8%,which is less than is assumed in the sensitivity projections. The results validate the full functionality of the module. Wediscuss the measured performance in the context of SO science requirements, which are exceeded.

Heather McCarrick↗

Feedhorn-Coupled Transition-Edge Superconducting Bolometer Arrays for Cosmic Microwave Background Polarimetry

NIST produces large-format, dual-polarization-sensitive detector arrays for a broad range of frequencies (30-1400 GHz). Such arrays enable a host of astrophysical measurements. Detectors optimized for cosmic microwave background observations are monolithic, polarization-sensitive arrays based on feedhorn and planar Nb antenna-coupled transition-edge superconducting (TES) bolometers. Recent designs achieve multiband, polarimetric sensing within each spatial pixel. In this proceeding, we describe our multichroic, feedhorn-coupled design; demonstrate performance at 70-380 GHz; and comment on current developments for implementation of these detector arrays in the advanced Atacama Cosmology Telescope receiver

multichroic↗

Fabrication of an Antenna-Coupled Bolometer for Cosmic Microwave Background Polarimetry

We describe the development of a detector for precise measurements of the cosmic microwave background polarization. The detector employs a waveguide to couple light between a pair of Mo/Au superconducting transition edge sensors (TES) and a feedhorn. Incorporation of an on-chip ortho-mode transducer (OMT) results in high isolation. The OMT is micromachined and bonded to the microstrip and TES circuits in a low temperature wafer bonding process. The wafer bonding process incorporates a buried superconducting niobium layer with a single crystal silicon layer which serves as the leg isolated TES membrane and as the microstrip dielectric. We describe the micromachining and wafer bonding process and report measurement results of the microwave circuitry operating in the 29-43GHz band along with Johnson noise measurements of the TES membrane structures and development of Mo/Au TES operating under '00mK.

Denis, K.L.↗

AC Read-Out Circuits for Single Pixel Characterization of TES Microcalorimeters and Bolometers

SRON is developing Frequency Domain Multiplexing (FDM) for the read-out of transition edge sensor (TES) soft x-ray microcalorimeters for the XMS instrument of the International X-ray Observatory and far-infrared bolometers for the SAFARI instrument on the Japanese mission SPICA. In FDM the TESs are AC voltage biased at frequencies from 0.5 to 6 MHz in a superconducting LC resonant circuit and the signal is read-out by low noise and high dynamic range SQUIDs amplifiers. The TES works as an amplitude modulator. We report on several AC bias experiments performed on different detectors. In particular, we discuss the results on the characterization of Goddard Space Flight Center x-ray pixels and SRON bolometers. The paper focuses on the analysis of different read-out configurations developed to optimize the noise and the impedance matching between the detectors and the SQUID amplifier. A novel feedback network electronics has been developed to keep the SQUID in flux locked loop, when coupled to superconducting high Q circuits, and to optimally tune the resonant bias circuit. The achieved detector performances are discussed in view of the instrument requirement for the two space missions.

Gottardi, L.↗

Optical Efficiency and R(T,I) Measurements of ACTPol TESes Using Time Domain Multiplexing Electronics

We present new data on feedhorn-coupled transition-edge sensor devices fabricated for the second-generation receiver (ACTPol) for the Atacama cosmology telescope (ACT). First, we describe optical efficiency measurements of the latest ACTPol detector wafer, which has a 86±15% average optical efficiency. Next, we discuss measurements of the TES resistance as a function of temperature and bias current ( R(T,I) ) using the ACTPol time-domain multiplexing electronics. Qualitative agreement between R(T,I) data at low bias current and the two-fluid model prediction is shown. Using the two-fluid model and low bias current R(T,I) data, α and β at our operating bias current are calculated.

Atacama cosmology telescope (ACT)↗

Fabrication of X-ray Microcalorimeter Focal Planes Composed of Two Distinct Pixel Types

We develop superconducting transition-edge sensor (TES) microcalorimeter focal planes for versatility in meeting the specifications of X-ray imaging spectrometers, including high count rate, high energy resolution, and large field of view. In particular, a focal plane composed of two subarrays: one of fine pitch, high count-rate devices and the other of slower, larger pixels with similar energy resolution, offers promise for the next generation of astrophysics instruments, such as the X-ray Integral Field Unit Instrument on the European Space Agencys ATHENA mission. We have based the subarrays of our current design on successful pixel designs that have been demonstrated separately. Pixels with an all-gold X-ray absorber on 50 and 75 micron pitch, where the Mo/Au TES sits atop a thick metal heatsinking layer, have shown high resolution and can accommodate high count rates. The demonstrated larger pixels use a silicon nitride membrane for thermal isolation, thinner Au, and an added bismuth layer in a 250-sq micron absorber. To tune the parameters of each subarray requires merging the fabrication processes of the two detector types. We present the fabrication process for dual production of different X-ray absorbers on the same substrate, thick Au on the small pixels and thinner Au with a Bi capping layer on the larger pixels to tune their heat capacities. The process requires multiple electroplating and etching steps, but the absorbers are defined in a single-ion milling step. We demonstrate methods for integrating the heatsinking of the two types of pixel into the same focal plane consistent with the requirements for each subarray, including the limiting of thermal crosstalk. We also discuss fabrication process modifications for tuning the intrinsic transition temperature (T(sub c)) of the bilayers for the different device types through variation of the bilayer thicknesses. The latest results on these 'hybrid' arrays will be presented.

Terms—Arrays↗

X-Ray Missions Based on LTD Technologies

Microcalorimeter arrays used as imaging spectrometers will enable ground-breaking science in X-ray astrophysics. Their development has been one of the driving applications of the low temperature detector community since the early 1980s. While their application in space remains in relative infancy, we are on the verge of an era in which microcalorimeter spectrometers are likely to dominate instrumentation for high-energy astrophysics missions. NASA sounding rocket experiments such as the X-ray Quantum Calorimeter (XQC) and Micro-X have now paved the way for orbital observatories. JAXA’s Astro-H gave us a glimpse of this fantastic new capability before its unfortunate demise. The launch of XRISM later this year should finally demonstrate the sort of large suite of observations that X-ray microcalorimeter arrays will make major contributions to. In the mid-2030s, we will see the launch of ESA’s flagship Athena mission, that will further advance the imaging and spectroscopic capabilities for the high-energy X-ray community enormously. Numerous other potential new mission concepts using X-ray microcalorimeters have been studied in detail such as NASA’s Lynx and the Light Element Mapper (LEM), JAXA’s Super-DIOS, and China’s Hot Universe Baryon Surveyor (HUBS). In the first half of this presentation, I will review the development and desired requirements of the X-ray microcalorimeter missions and concepts, and describe the current progress and status missions being implemented and proposed. In the second half of this presentation, I will focus on The Line Emission Mapper (LEM) which is a probe-class mission concept under study by NASA that is designed to provide unprecedented insight into the physics of galaxy formation, including stellar and black-hole feedback and flows of baryonic matter into and out of galaxies. LEM incorporates a light-weight X-ray optic with 10” angular resolution and a large-format microcalorimeter array with a 15” pixel pitch over a 29’ field of view (FOV). The main microcalorimeter array and readout design takes advantage of mature technology that has been developed for Athena X-IFU. The central 7’ region of the array consists of ~ 800 transition-edge sensors (TESs), optimized for a bandpass of 0.3-2 keV and with an energy resolution of 1.2 eV at 1 keV. The rest of the FOV is covered by 4-pixel TES hydras with 2.5 eV energy resolution at 1 keV. Hydras are position-sensitive (‘thermally multiplexed’) detectors that enable extremely large numbers of effective pixels in an array, without a commensurate increase in the number of wires, bias circuit, and readout components. In total the array will have ~ 4k TESs with ~ 14k imaging elements on a 290 micron-pitch. The array will be read out with state-of-the-art time-division multiplexing (TDM), implement with 59 pixels (and 1 dark pixel) in each of the 69 TDM columns. Here we present a detailed overview of the baseline microcalorimeter detector design and present first results from both single pixel TESs and 4-pixel hydras. Our prototype LEM pixels utilize 15um x 50um Mo/Au TESs with a transition temperature of around 58 mK. These pixels incorporate high-fill-factor Au absorbers of thickness 0.54um. We have demonstrated an energy resolution of 0.90+/-0.02 eV and 1.90 +/-0.02 eV at 1.5 keV for single pixel and 4-pixel hydras, respectively, meeting the performance requirements of LEM. We show how the position discrimination in the hydra pixels can be achieved, down to energies of a few 100 eV, using the measured pulse rise-times. Finally, we will show that the properties of the LEM pixels are well optimized for the proposed TDM read out architecture.

Simon Richard Bandler↗

Calibration and Testing of Small High-Resolution Transition Edge Sensor Microcalorimeters With Optical Photons

Pulses of narrow line-width optical photons can be used to calibrate and test sub-2 eV full-width at half-maximum (FWHM) energy resolution transition-edge sensor (TES) microcalorimeters at low energies (<1 keV),where it is very challenging to obtain X-ray calibration lines comparable to (or narrower than) the detector resolution. This scheme depends on the ability to resolve the number of 3 eV photons in each pulse, which we have recently demonstrated up to photon numbers of about 300. AtLTD-18 we showed preliminary results obtained with this technique on a 0.25 eV baseline resolution TES microcalorimeter designed for the ultra-high-resolution sub-array of the Lynx mission. The line-shape was well described by a simple Gaussian. However, the difficulty of delivering photons to the small 46 μm square absorbers resulted in a large thermal crosstalk signal, whose random nature is expected to rapidly degrade the observed energy resolution towards higher photon numbers/energies. We have since improved the coupling between the optical fiber and the TES absorber and report here our current results.

Felix T Jaeckel↗

Transition-Edge Hot-Electron Microbolometers for Millimeter and Submillimeter Astrophysics

The millimeter and the submillimeter wavelengths of the electromagnetic spectrum hold a wealth of information about the evolution of the universe. In particular, cosmic microwave background (CMB) radiation and its polarization carry the oldest information in the universe, and provide the best test of the inflationary paradigm available to astronomy today. Detecting gravity waves through their imprint on the CMB polarization would have extraordinary repercussions for cosmology and physics. A transition-edge hot-electron micro - bolometer (THM) consists of a superconducting bilayer transition-edge sensor (TES) with a thin-film absorber. Unlike traditional monolithic bolometers that make use of micromachined structures, the THM em ploys the decoupling between electrons and phonons at millikelvin temperatures to provide thermal isolation. The devices are fabricated photolithographically and are easily integrated with antennas via microstrip transmission lines, and with SQUID (superconducting quantum interference device) readouts. The small volume of the absorber and TES produces a short thermal time constant that facilitates rapid sky scanning. The THM consists of a thin-film metal absorber overlapping a superconducting TES. The absorber forms the termination of a superconducting microstripline that carries RF power from an antenna. The purpose of forming a separate absorber and TES is to allow flexibility in the optimization of the two components. In particular, the absorbing film's impedance can be chosen to match the antenna, while the TES impedance can be chosen to match to the readout SQUID amplifier. This scheme combines the advantages of the TES with the advantages of planar millimeter-wave transmission line circuits. Antenna-coupling to the detectors via planar transmission lines allows the detector dimensions to be much smaller than a wavelength, so the technique can be extended across the entire microwave, millimeter, and submillimeter wavelength ranges. The circuits are fabricated using standard microlithographic techniques and are compatible with uniform, large array formats. Unlike traditional monolithic bolometers that make use of micromachined structures, the THM employs the decoupling between electrons and phonons at millikelvin temperatures to provide thermal isolation. There is no fragile membrane in the structure for thermal isolation, which improves the fabrication yield.

Hsieh, Wen-Ting↗

Unexpected Nonlinear Effects in Superconducting Transition-Edge Sensors

When a normal metal transitions into the superconducting state the DC resistance drops from a finite value to zero over some finite transition width in temperature, current, and magnetic field. Superconducting transition-edge sensors (TESs) operate within this transition region and uses resistive changes to measure deposited thermal energy. This resistive transition is not perfectly smooth and a wide range of TES designs and materials show sub-structure in the resistive transition (as seen in smooth nonmonotonic behavior, jump discontinuities, and hysteresis in the devices current-voltage relation and derivatives of the resistance with respect to temperature, bias current, and magnetic field). TES technology has advanced to the point where for many applications this structure is the limiting factor in performance and optimization consists of finding operating points away from these structures. For example, operating at or near this structure can lead to nonlinearity in the detectors response and gain scale, limit the spectral range of the detector by limiting the usable resistive range, and degrade energy resolution. The origin of much of this substructure is unknown. This presentation investigates a number of possible sources in turn. First we model the TES as a superconducting weak-link and solve for the characteristic differential equations current and voltage time dependence. We find:(1) measured DC biased current-voltage relationship is the time-average of a much higher frequency limit cycle solution.(2) We calculate the fundamental frequency and estimate the power radiated from the TES treating the bias leads as an antennae.(3) The solution for a set of circuit parameters becomes multivalued leading to current transitions between levels.(4)The circuit parameters can change the measure resistance and mask the true critical current. As a consequence the TES resistance surface is not just a function of temperature, current, and magnetic field but is also a function of the circuit elements (such as shunt resistor, SQUID inductance, and capacitor values). In other words, same device measured in different electrical circuits will have a different resistive surface in temperature, current, and magnetic field. Next we consider that at the transition temperature of a superconductor both the magnetic penetration depth and coherence length are divergent. As a consequence these important characteristic length scales are changing with operating point. We present measurements on devices showing commensurate behavior between these characteristic lengths and the length scale of added normal metal structures. Reordering of proximity vortices leads to discontinuities and irreversibility of the current-voltage curves. Last we consider a weak-link TES including both thermal activated resistance effects and the effect of the magnetic penetration depth being a function of temperature and magnetic field. We derive its impact on the resistive transition surface and the important device parameters a and b.

Superconducting Detectors↗

Toward Large FOV High-Resolution X-Ray Imaging Spectrometer: Microwave Multiplexed Readout of 32 TES Microcalorimeters

We performed a small-scale demonstration at GSFC of high-resolution x-ray TES microcalorimeters read out using a microwave SQUID multiplexer. This work is part of our effort to develop detector and readout technologies for future space based x-ray instruments such as the microcalorimeter spectrometer envisaged for Lynx, a large mission concept under development for the Astro 2020 Decadal Survey. In this paper we describe our experiment, including details of a recently designed, microwave-optimized low-temperature setup that is thermally anchored to the 50 mK stage of our laboratory ADR. Using a ROACH2 FPGA at room temperature, we simultaneously read out 32 pixels of a GSFC-built detector array via a NIST-built multiplexer chip with Nb coplanar waveguide resonators coupled to RF SQUIDs. The resonators are spaced 6 MHz apart (at approx. 5.9 GHz) and have quality factors of approximately 15,000. Using flux-ramp modulation frequencies of 160 kHz we have achieved spectral resolutions of 3 eV FWHM on each pixel at 6 keV. We will present the measured system-level noise and maximum slew rates, and briefly describe the implications for future detector and readout design.

Yoon, Wonsik↗