Search NASA⌕ Search

SEARCH · Search NASA

Results for “TEST STAND”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

A harmonized protocol to assess the single-cell performance of proton exchange membrane water electrolyzers

The harmonization of testing protocols for proton exchange membrane (PEM) electrolyzers is essential for ensuring accurate and reliable performance assessments and accelerating the development of hydrogen production technologies. This protocol provides a structured approach to PEM electrolyzer setup and testing, incorporating key considerations for test station design and single-cell characterization techniques. Polarization curves and electrochemical impedance spectroscopy (EIS) are detailed, along with best practices from academic and industry research groups to enhance data accuracy and comparability. By addressing material variability and harmonizing testing methodologies, this framework enables more precise evaluations of membrane electrode assemblies and electrolyzer components. Harmonized protocols not only streamline development efforts but also foster collaboration across institutions, ultimately supporting the commercialization of hydrogen solutions through improved stack efficiency and durability.

08 HYDROGEN↗

Full Submersion Water Testing of SAVY-4000 Nuclear Material Storage Containers

SAVY-4000 (SAVY) containers are the primary container used at Technical Area (TA) TA-55 plutonium facility for the prevention of water ingress to mitigate against a criticality event. The basis for water resistance of these containers has long been attributed to the Polytetrafluoroethylene (PTFE) membrane that is assembled on the outermost surface of the filter assembly. On August 22nd a test of a container used inside of a glovebox was performed that brought into question this long-standing-basis. This test was performed by inverting a SAVY-lid onto a specialized piece of equipment for evaluating the integrity of the PTFE membrane. During the test water was observed passing through the filter indicating that the filter membrane was no longer preventing the ingress of water through the filter. The assumption after making this observation was that alpha-particles were rapidly degrading the membrane creating a leak path through the underlying aluminosilicate media (Fiberfrax®). The apparatus used was designed to only test the lid rather than the entire SAVY assembly. A test plan, PA-PLAN-01921, was developed to investigate whether a fully assembled container with a fully degraded PTFE membrane would be capable of meeting the criteria defined in PA-RD-1009 of not allowing more than 200 ml of water to enter the container with a water column of 6-inches applied over a 2-hour period. This report provides the results of the testing performed against PA-PLAN-01921.

36 MATERIALS SCIENCE↗

Demonstration and performance of an online data selection algorithm for liquid argon time projection chambers using MicroBooNE

The MicroBooNE detector is a liquid argon time projection chamber (LArTPC) that produces three-dimensional images of particle interactions using ionization charge collected by anode wire plane arrays and scintillation light collected by a light detection system. In addition to testing long-standing experimental neutrino anomalies and performing measurements of neutrino interactions with argon nuclei using the Fermilab Booster Neutrino Beam, MicroBooNE aims to develop methodologies for rare beyond the Standard Model and off-beam physics searches. Looking ahead to the upcoming Deep Underground Neutrino Experiment (DUNE), with MicroBooNE serving as a valuable testbed, achieving high sensitivity and livetime for off-beam physics while satisfying data processing and storage constraints will require data-driven, intelligent, and online or real-time data selection techniques. These techniques are essential for reducing data rates and preserving rare signals with high accuracy. In this paper, we describe a fast data selection algorithm suitable for online execution to identify electrons from stopping cosmic ray muons in the MicroBooNE detector utilizing ionization charge information, and present its performance. This represents the first demonstration of online data selection in a LArTPC using real data and charge information exclusively and provides an important proof-of-principle for applying such techniques to other LArTPC experiments such as the Short-Baseline Near Detector and DUNE.

Abratenko, P. [Tufts U. (main)]↗

High-power test of a C-band linear accelerating structure with an RFSoC-based LLRF system

Normal conducting linear particle accelerators consist of multiple rf stations with accelerating structure cavities. Low-level rf (LLRF) systems are employed to set the phase and amplitude of the field in the accelerating structure and to compensate for the pulse-to-pulse fluctuation of the rf field in the accelerating structures with a feedback loop. The LLRF systems are typically implemented with analog rf mixers, heterodyne-based architectures, and discrete data converters. There are multiple rf signals from each of the rf stations, so the number of rf channels required increases rapidly with multiple rf stations. With a large number of rf channels, the footprint, component cost, and system complexity of the LLRF hardware will increase significantly. To meet the design goals of being compact and affordable for future accelerators, we have designed the next-generation LLRF (NG-LLRF) with a higher integration level based on RFSoC technology. The NG-LLRF system samples rf signals directly and performs rf mixing digitally. Further, the NG-LLRF has been characterized in loopback mode to evaluate the performance of the system and has also been tested with a standing-wave accelerating structure, a prototype for the Cool Copper Collider (C 3 ) with a peak rf power level up to 16.45 MW. The loopback test demonstrated amplitude fluctuation below 0.15% and phase fluctuation below 0.15°, which are considerably better than the requirements of C 3 . The rf signals from the different stages of the accelerating structure at different power levels are measured by the NG-LLRF, which will be critical references for the control algorithm designs. The NG-LLRF also offers flexibility in waveform modulation, so we have used rf pulses with various modulation schemes, which could be useful for controlling some of the rf stations in accelerators. In this paper, the high-power test results at different stages of the test setup will be summarized, analyzed, and discussed.

47 OTHER INSTRUMENTATION↗

Testing Capabilities for Superconducting Magnets at Fermilab

This presentation will focus on the current testing capabilities for superconducting magnets at Fermilab, highlighting existing systems, recent upgrades, and future plans. The Vertical Magnet Test Facility (VMTF) remains a cornerstone for testing superconducting magnets in R&D applications, maintaining its established capabilities. Stand 4 continues to support the Hi-Lumi AUP production line of magnets in cryostats and has achieved significant improvements through a redesign of lead connections, resolving issues with liquid helium levels and resistance, culminating in a successful endurance test without interruption. Similarly, Stand 7 underwent commissioning and a lead redesign to reduce heat load, while its core testing capabilities remain unchanged. Looking forward, Stand 3 is undergoing a redesign, with plans to restart and begin commissioning by the end of 2025, introducing new features such as background magnetic field testing and upgraded power supplies. Fermilab is also advancing the High Field Vertical Magnet Test Facility (HFVMTF), designed to support the fusion and magnet R&D program, with commissioning scheduled for 2025 and critical components, including the cryostat and power supplies, being delivered. Enhancing all operations, the newly commissioned IB1 cryoplant now offers automated overnight helium production and efficient transfer to a 10,000-liter dewar, streamlining support across all test stands. This talk will provide a comprehensive overview of testing capabilities, and showcasing how Fermilab is advancing its capabilities to meet the evolving demands of superconducting magnet testing.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Performance Evaluation of a Microgrid System with Grid-Forming and Grid-Following Inverters with Diesel Generators: Insights From Hardware Experiments

This paper presents a comprehensive performance evaluation of a microgrid system integrating grid-forming (GFM) inverters, grid-following (GFL) inverters, and a diesel generator, focusing on their interactions and behavior under various dynamic events. The study is conducted using a pure hardware setup comprising two GFM inverters, one GFL inverter, a diesel generator, load banks, a point of common coupling (PCC), and an emulated main grid. The evaluation specifically examines dynamic scenarios, including voltage jumps, phase jumps, rate of change of frequency (ROCOF), synchronization, and islanding operations, which pose critical challenges to system stability. Among all the tests conducted, the overloading and phase jump tests proved to be the most challenging. The capacity of the DC side is crucial for withstanding overloading and grid disturbance tests; otherwise, GFM inverters frequently trip due to DC undervoltage. Throughout all grid disturbance tests, the diesel generator consistently stands out as the most robust and reliable GFM unit in the system. Overall, insights from these hardware experiments shed light on the response characteristics of different generation types during grid disturbances and identify potential stability concerns in such hybrid microgrid systems.

14 SOLAR ENERGY↗

A renewable double plasma mirror for Petawatt-class lasers

Exceptional pulse contrast can be critical for ultraintense laser experiments, particularly when using solid density targets, and their use is becoming widespread. However, current plasma mirror technology is becoming inadequate for the new generation of high repetition rate, high power lasers now available. We describe a novel double plasma mirror configuration based on renewable, free standing, ultrathin liquid crystal films tested at the BELLA Petawatt Laser Center. Although operating at a repetition rate of several shots per minute, this system can be scaled to a high repetition rate exceeding 1 Hz and represents an important step towards enabling sustained, continuous operation of plasma mirrors. We demonstrate an improvement of two to three orders of magnitude in contrast and a total throughput of 80%. We present the first measurements of a beam reflected from a single or double plasma mirror system using a wavefront sensor, showing a well preserved wavefront and spatial mode. Finally, we introduce a model that predicts the total throughput through this double plasma mirror. This is the first model that accurately predicts the peak reflectivity of a plasma mirror when given the laser temporal profile.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Morphological Degradation of Oxygen Evolution Reaction-Electrocatalyzing Nickel Selenides at Industrially Relevant Current Densities

We investigated electrodeposited nanoparticulate nickel selenide (pre)catalysts that transform into nickel oxides/ oxyhydroxides under oxygen evolution reaction conditions in alkaline solutions. Previous studies of this transformation were conducted at lower current densities than those of industrial relevance (≥1 A cm −2 ). We used ultramicroelectrodes (UMEs) to achieve such current densities, benefiting from their small size, ensuring low absolute currents and low ohmic drop but high current densities. Morphological degradation of the catalyst material was only observed at current densities exceeding 1 A cm −2 but not for smaller ones. Using X-ray absorption, Xray photoemission spectroscopy, and X-ray diffraction, we confirmed that the degradation was accompanied by the literature-known transformation of nanoparticulate Ni 3 Se 2 (bulk)/NiSe (surface) into nickel oxyhydroxide. The transformation of the precatalyst goes along with a significant improvement in the charge transfer kinetics observed by decreasing Tafel slopes with ongoing experimental time extracted from cyclic voltammetry (CV) experiments and electrochemical impedance spectroscopy (EIS) in the high-frequency range. However, these kinetic improvements are accompanied by limitations in mass transport concluded from decreasing current responses at high overpotentials in CVs and increasing impedance in the low-frequency range of the EIS spectra after extended CV cycling. These mass transport limitations originated from morphological degradations at the UME exceeding 1 A cm −2 which we proved by applying identical location scanning electron microscopy. This has not been reported in studies that have been limited to lower current densities before. Our findings showcase how UMEs can be used to study (pre)catalysts (herein nickel selenides) under current densities of industrial relevance in the absence of ohmic drop-related ambiguities, combined with in-depth materials characterization studies, e.g., identical location microscopy and advanced spectroscopic methods. This approach enables direct evaluation and comparison of catalyst materials and thus demonstrates how to overcome long-standing limitations of electrocatalyst design and testing.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The ORNL Moderator Test Station Science Case

Oak Ridge National Laboratory (ORNL) hosts two world-leading slow neutron sources, the Spallation Neutron Source (SNS) and the High Flux Isotope Reactor (HFIR), and is currently developing the technical design for a Second Target Station (STS) for the SNS. Upon completion of the STS project, ORNL will be uniquely positioned to optimize each of its three neutron sources, the SNS First Target Station (FTS), the STS, and HFIR, in a complementary way. Among the essential aspects of a re-imagined FTS and the current STS design are high-brightness parahydrogen moderators—moderators which are optimized for high per-unit-area neutron brightness rather than integrated-across-large-area neutron intensity. The high-brightness moderators proposed for the STS will, for the brightness metric, significantly outperform the coupled moderators currently on the FTS for appropriately optimized neutron beamlines, provided the moderating hydrogen is converted to near-equilibrium levels of parahydrogen (approximately 99.8% at 20 K). The original FTS moderators, by contrast, were conservatively designed to be relatively insensitive to the exact ortho:para ratio, with a consequent loss in performance. As a result, a redesign of the FTS moderators assuming fully converted parahydrogen could result in significant performance improvements on the FTS coupled moderators, and more consistent performance over time for all hydrogen moderators. This “parahydrogen problem” is a long-standing challenge for the effective implementation of hydrogen cold moderators at high-power neutron sources. In addition, the development of new moderator concepts, whether based on previously unused materials, structured heterogeneous arrays, or even simply on changes in overall shape and size is significantly restricted at a large-scale production facility intended to use the resulting neutron beams. Accordingly, moderators for production neutron sources are often designed in a very conservative, low-risk fashion, even though this compromises the absolute neutronic performance. Advanced moderator concepts worthy of study include features that could not be tested without redesigning and redeploying the entire existing reflector, shielding, and neutron beamline installation, making such development efforts far more expensive than building a stand-alone test facility.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Computer Programs For Analysis Of Thermally Reactive Tracer Tests In Geothermal Reservoirs

The Tracer Analysis Toolbox (TAT) is a stand-alone executable software package that focuses on reservoir monitoring, using changes in concentration of thermally degrading tracers between and injection well and a production well to reflect the temperature-time histories along flow paths through the reservoir. By conducting such tests periodically, the thermal evolution of the flow paths connecting injection wells to production wells can be monitored. Because this approach is sensitive to temperature along the whole path, it can detect changes well before they occur at the distal end of the path (i.e., the production well). Thus, the thermally degrading tracer method provides early detection of thermal decline before it impacts that well. The goal of TAT is to simplify planning of a reactive tracer monitoring campaign and interpretation of results by providing: (1) tracer test planning and analysis tools to define the necessary kinetic parameters, injection concentrations, and other tracer parameters that are suitable for the expected reservoir residence time and temperature, (2) identification of tracers with suitable characteristics (defined by (1)) and (3) a suite of analysis programs to analyze tracer test results.

Plummer, MitchellAaron [Idaho National Laboratory ↗

Hyperelastic nature of the Hoek–Brown criterion

In this article, we propose a nonlinear elasto-plastic model, for which a specific class of hyperbolic elasticity arises as a straight consequence of the yield criterion invariance on the plasticity level. We superimpose this nonlinear elastic (or hyperelastic) behavior with plasticity obeying the associated flow rule. Interestingly, we find that a linear yield criterion on the thermodynamical force associated with plasticity results in a quadratic yield criterion in the stress space. This suggests a specific hyperelastic connection between Mohr–Coulomb and Hoek–Brown (or alternatively between Drucker–Prager and Pan–Hudson) yield criteria. We compare the elasto-plastic responses of standard tests for the Drucker–Prager yield criterion using either linear or the suggested hyperbolic elasticity. Notably, the nonlinear case stands out due to dilatancy saturation observed during cyclic loading in the triaxial compression test. We conclude this study with structural finite element simulations that clearly demonstrate the numerical applicability of the proposed model.

97 MATHEMATICS AND COMPUTING↗

Compact cryomodule for mobile stand-alone superconducting industrial accelerators

Superconducting RF (SRF) accelerators have the potential to be more profitable in comparison with normally conducting accelerators, as long they can be made compact, achieve operational simplicity, autonomy, trans- portability, satisfactory energy efficiency, as well as have reasonable costs. The development of SRF technologies such as Nb 3 Sn coating, conductively-cooled resonators, and high-capacity liquid-helium-free cryocoolers made SRF accelerators mobile and energetically and economically efficient at a beam power of tens of kW. One of the key elements of such an accelerator is the cryomodule, which must have minimal thermal losses to enable operation from low power cryoheads and enable conductive cooling of SRF resonator. In this research we present the design and test results of a compact cryomodule for an industrial stand-alone SRF linear accelerator proto- type, based on 650 MHz elliptical resonators, being developed at Fermi National Accelerator Laboratory.

43 PARTICLE ACCELERATORS↗

Standardization and best practices in single-cell testing for liquid alkaline water electrolysis

The increasing demand for efficient and sustainable hydrogen production has driven significant advancements in water electrolysis technologies. Among these, liquid alkaline water electrolysis (LAWE) stands out for its cost-effectiveness and scalability. This manuscript establishes best practices and standardized testing procedures for single-cell LAWE, focusing on the use of nickel foam as both anode and cathode substrates, while incorporating catalysts such as nickel-iron layered double hydroxide (NiFe-LDH) as the anode material and nickel-molybdenum on carbon (NiMo/C) as the cathode material. By providing detailed guidelines on material preparation, cell assembly, and performance evaluation, this work offers a comprehensive framework to improve reproducibility and ensure consistency. The results demonstrate that applying these best practices minimizes variability across different laboratories and experimental setups, laying the groundwork for more robust comparisons and accelerating progress in LAWE research.

08 HYDROGEN↗

Experiments towards a neutron target for measurements in inverse kinematics

Neutron-induced reactions play an important role in fundamental nuclear physics, nuclear astrophysics, and applications. In the case of reactions on rare isotopes, there are limited options for direct experimental measurements. The Neutron Target Demonstrator project at Los Alamos National Laboratory seeks to test the feasibility of moderating spallation neutrons within a 1 m 3 graphite cube to create a standing neutron target for neutron-induced reaction measurements in inverse kinematics. This paper presents the results of experimental neutron flux distribution tests using neutron sources (ranging from 1 keV to 50 MeV) created by accelerators at the University of Notre Dame and Texas A&M University. Measurements were made with both the full graphite cube as well as a ”half cube” setup in which half of the graphite cube was removed. The measured distributions agree with simulated distributions in the case of the full cube moderator, although there remain discrepancies in certain cases for the half cube moderator. The results shown here will provide useful information for an upcoming experimental campaign to test the neutron target proof-of-principle.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Proof-of-Concept for Sensor Modeling in MOOSE for the Design of Autonomous Nuclear Reactor Control

Autonomous operation is essential for the deployment of microreactors and fission batteries, both in terrestrial and space applications. However, prototypes of microreactors and fission batteries do not exist yet, and even the design space has not been narrowed down conclusively, making the instrumentation and control system design difficult. For this reason, there is a need for flexible computational capabilities to create a numerical stand-in of potential microreactor and fission battery designs. The latter can be used to design and test control strategies to support autonomous operations. In this paper, we describe the initial implementation of a pluggable sensor system for the easy implementation of realistic sensor models in the multiphysics object-oriented simulation environment (MOOSE) framework. This new capability will enable MOOSE users to create a numerical stand-in of microreactors and fission batteries, ultimately allowing them to easily test new control algorithms, and instrumentation strategies for advanced systems in the design phase

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Proof-of-Concept for Sensor Modeling in MOOSE for the Design of Autonomous Nuclear Reactor Control

Autonomous operation is essential for the deployment of microreactors and fission batteries, both in terrestrial and space applications. For this reason, recent studies have investigated autonomous control by using adaptive model predictive control and multi-objective optimization for heat pipe–cooled microreactors under normal and heat pipe failure conditions. However, prototypes of microreactors and fission batteries do not exist yet, and even the design space has not been narrowed down conclusively, making the instrumentation and control system design difficult. For this reason, there is a need for flexible computational capabilities to create a numerical stand-in of potential microreactor and fission battery designs. The latter can be used to design and test control strategies to support autonomous operations. In this poster, we describe the initial implementation of a pluggable sensor system for the easy implementation of realistic sensor models in the multiphysics object-oriented simulation environment (MOOSE) framework. This new capability will enable MOOSE users to create a numerical stand-in of microreactors and fission batteries, ultimately allowing them to easily test new control algorithms, and instrumentation strategies for advanced systems in the design phase.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Three-step LES-C models for flows at high Reynolds numbers

Here, we investigate the need for the second correction step in the recently proposed LES-C models for fluid flows at high Reynolds numbers. These models use a predictor-corrector idea to enhance the efficiency of the existing Large Eddy Simulation models. Different three-step(one defect step, two corrections) LES-C models, based on the Leray-α, ADM and NS-ω LES models, are tested in three different situations. The new Leray-α-C2 model (C2 stands for two correction steps) is applied to the Navier–Stokes equations; the ADC2 is applied to the MagnetoHydroDynamic flow; and the NS-ω-C2 is used in the fluid-fluid interaction problem. We evaluate the effectiveness of the second correction step in all these settings, using qualitative and quantitative numerical tests.

97 MATHEMATICS AND COMPUTING↗

Calibration verification for stochastic agent-based disease spread models

Accurate disease spread modeling is crucial for identifying the severity of outbreaks and planning effective mitigation efforts. To be reliable when applied to new outbreaks, model calibration techniques must be robust. However, current methods frequently forgo calibration verification (a stand-alone process evaluating the calibration procedure) and instead use overall model validation (a process comparing calibrated model results to data) to check calibration processes, which may conceal errors in calibration. In this work, we develop a stochastic agent-based disease spread model to act as a testing environment as we test two calibration methods using simulation-based calibration, which is a synthetic data calibration verification method. The first calibration method is a Bayesian inference approach using an empirically-constructed likelihood and Markov chain Monte Carlo (MCMC) sampling, while the second method is a likelihood-free approach using approximate Bayesian computation (ABC). Simulation-based calibration suggests that there are challenges with the empirical likelihood calculation used in the first calibration method in this context. These issues are alleviated in the ABC approach. Despite these challenges, we note that the first calibration method performs well in a synthetic data model validation test similar to those common in disease spread modeling literature. We conclude that stand-alone calibration verification using synthetic data may benefit epidemiological researchers in identifying model calibration challenges that may be difficult to identify with other commonly used model validation techniques.

60 APPLIED LIFE SCIENCES↗