Search NASA⌕ Search

SEARCH · Search NASA

Results for “THERMAL COMFORT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Energy and Comfort Impacts of High Performance Facades in Office Buildings

Building facades have a major effect on energy use, occupant comfort, and well-being. Yet adoption of high-performance facades is often slowed by limited data and unclear cost benefits. To address this gap, Oak Ridge National Laboratory, in collaboration with the Facade Tectonics Institute, conducted whole-building energy simulations to evaluate fenestration technologies for small and medium office buildings across three weather locations: hot (Tampa, Florida, weather zone 2A), mixed (New York, New York, weather zone 4A), and cold (Rochester, Minnesota, weather zone 6A). The simulations included parametric variations in window-to-wall ratio (30%–70%), U-values (0.1–1 Btu/h∙ft 2 ∙°F), solar heat gain coefficients (0.2–0.8), and solar control strategies and devices (e.g., interior shades and switchable glazing). Performance metrics included annual cooling, heating, and total heating, ventilation and air-conditioning (HVAC) energy use intensity, as well as nonenergy factors such as useful daylight illuminance, glare frequency, and thermal comfort during typical office hours (8 a.m.–6 p.m.). Results indicate that cooling energy consumption is most sensitive to solar heat gain coefficient (SHGC) in hot weather, whereas heating energy consumption is strongly influenced by U-value in cold weather. Total HVAC reflects these trade-offs, showing up to 60% difference for a window in total HVAC energy use intensity between different combinations of U-value and SHGC. Daylight dimming generally reduces cooling loads but can increase heating demands in colder locations. Interior solar shades improve useful daylight and reduce discomfort glare, whereas switchable glazing delivers the largest cooling reductions in hot weather but may increase heating loads in winter by limiting passive solar gains. Thermal comfort improves with lower window-to-wall ratios and lower SHGC in hot locations and with lower U-values in cold locations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Space Suit Portable Life Support System (PLSS) 2.0 Human-in-the-Loop (HITL) Testing

The space suit Portable Life Support System (PLSS) 2.0 represents the second integrated prototype developed and tested to mature a design that uses advanced technologies to reduce consumables, improve robustness, and provide additional capabilities over the current state of the art. PLSS 2.0 was developed in 2012, with extensive functional evaluations and system performance testing through mid-2014. In late 2014, PLSS 2.0 was integrated with the Mark III space suit in an ambient laboratory environment to facilitate manned testing, designated PLSS 2.0 Human-in-the-Loop (HITL) testing, in which the PLSS prototype performed the primary life support functions, including suit pressure regulation, ventilation, carbon dioxide control, and cooling of the test subject and PLSS avionics. The intent of this testing was to obtain subjective test subject feedback regarding qualitative aspects of PLSS 2.0 performance such as thermal comfort, sounds, smells, and suit pressure fluctuations due to the cycling carbon dioxide removal system, as well as to collect PLSS performance data over a range of human metabolic rates from 500-3000 Btu/hr. Between October 27 and December 18, 2014, nineteen two-hour simulated EVA test points were conducted in which suited test subjects walked on a treadmill to achieve a target metabolic rate. Six test subjects simulated nominal and emergency EVA conditions with varied test parameters including metabolic rate profile, carbon dioxide removal control mode, cooling water temperature, and Liquid Cooling and Ventilation Garment (state of the art or prototype). The nineteen test points achieved more than 60 hours of test time, with 36 hours accounting for simulated EVA time. The PLSS 2.0 test article performed nominally throughout the test series, confirming design intentions for the advanced PLSS. Test subjects' subjective feedback provided valuable insight into thermal comfort and perceptions of suit pressure fluctuations that will influence future advanced PLSS design and testing strategies.

Watts, Carly↗

Space Suit Portable Life Support System (PLSS) 2.0 Human-in-the-Loop (HITL) Testing

The space suit Portable Life Support System (PLSS) 2.0 represents the second integrated prototype developed and tested to mature a design that uses advanced technologies to reduce consumables, improve robustness, and provide additional capabilities over the current state of the art. PLSS 2.0 was developed in 2012, with extensive functional evaluations and system performance testing through mid-2014. In late 2014, PLSS 2.0 was integrated with the Mark III space suit in an ambient laboratory environment to facilitate manned testing, designated PLSS 2.0 Human-in-the-Loop (HITL) testing, in which the PLSS prototype performed the primary life support functions, including suit pressure regulation, ventilation, carbon dioxide control, and cooling of the test subject and PLSS avionics. The intent of this testing was to obtain subjective test subject feedback regarding qualitative aspects of PLSS 2.0 performance such as thermal comfort, sounds, smells, and suit pressure fluctuations due to the cycling carbon dioxide removal system, as well as to collect PLSS performance data over a range of human metabolic rates from 500-3000 Btu/hr. Between October 27 and December 18, 2014, nineteen two-hour simulated EVA test points were conducted in which suited test subjects walked on a treadmill to achieve a target metabolic rate. Six test subjects simulated nominal and emergency EVA conditions with varied test parameters including metabolic rate profile, carbon dioxide removal control mode, cooling water temperature, and Liquid Cooling and Ventilation Garment (state of the art or prototype). The nineteen test points achieved more than 60 hours of test time, with 36 hours accounting for simulated EVA time. The PLSS 2.0 test article performed nominally throughout the test series, confirming design intentions for the advanced PLSS. Test subjects' subjective feedback provided valuable insight into thermal comfort and perceptions of suit pressure fluctuations that will influence future advanced PLSS design and testing strategies.

Watts, Carly↗

An Open-Source Virtual Testbed for a Real Net-Zero Energy Community

Net zero energy communities (NZECs) are critical to ensure sustainability and resilience of modernized power systems. System modeling helps overcome technical challenges in designing and operating NZECs. In this paper, we present the modeling work based on a real NZEC. Two sets of models are developed: higher-fidelity physics-based models considering the interaction between subsystems of the studied NZEC and capturing fast-dynamics; and lower-fidelity data-driven models requiring less resource to establish and/or run. All models are validated against measurements from this real NZEC. In addition, we create a simulation framework which streamlines the processes for simulation and thus allows using developed models to form a virtual testbed. To demonstrate the usage of the virtual testbed, a case study is conducted where a building-to-grid integration control is evaluated via simulation. The evaluation results suggest that the tested control significantly smooths the power draw of the studied community and doesn’t sacrifice the thermal comfort to a great extent.

Huang, Sen↗

Cloud-based implementation of white-box model predictive control for a GEOTABS office building: A field test demonstration

Model predictive control (MPC) has been proven in simulations and pilot case studies to be a superior control strategy for large buildings. MPC can utilize the weather and occupancy schedule forecasts, together with the system model, to predict the future thermal behavior of the building and minimize the overall energy use and maximize thermal comfort. However, these advantages come with the cost of increased modeling effort, computational demands, communication infrastructure, and commissioning efforts. Thus a typical approach is to, often rapidly, simplify the building modeling and MPC optimization problem while paying a price of not reaching the full performance potential. It has been shown that by employing accurate physics-based models, MPC performance can be notably increased closer to its theoretical performance bound. However, implementation of such high-fidelity MPC in real buildings remains a challenge, resulting in a lack of successful field test studies. This work presents the methodology and field test demonstration of a computationally efficient implementation of the white-box MPC in an office building in Belgium. The detailed model of the building is based on first-principle physical equations. The deployment and supervision of MPC operation in a practical setting are supported by an automated cloud-based communication infrastructure. The motivating factor behind the cloud-based architecture is its compatibility with a commercially appealing control as a service concept. The building is equipped with a ground source heat pump (GSHP) and thermally activated building structures (TABS), where the combination of both is also known as GEOTABS. From a control perspective, GEOTABS buildings are particularly challenging systems due to large scale, complex heating, ventilation and air conditioning (HVAC) system, and slow dynamics with time delays. On the other hand, there is an increased potential for energy savings due to the high thermal mass, which acts as thermal storage. The MPC operation is demonstrated during the challenging transient seasons (switching between heating and cooling), and its performance is compared to a traditional rule-based controller (RBC). We provide a proof of concept of real MPC operation for the most difficult seasons with notable GSHP energy use savings equal to 53.5% and thermal comfort improvement by 36.9%. Other MPC applications found in the literature describe tests for only cooling or only heating, and up to now only for a black-box or a grey-box approach.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hierarchical Model-Free Transactional Control of Building Loads to Support Grid Services

A transition from generation on demand to consumption on demand is one of the solutions to overcome the many limitations associated with the higher penetration of renewable energy sources. Such a transition, however, requires a considerable amount of load flexibility in the demand side. Demand response (DR) programs can reveal and utilize this demand flexibility by enabling the participation of a large number of grid-interactive efficient buildings (GEB). Existing approaches on DR require significant modelling or training efforts, are computationally expensive, and do not guarantee the satisfaction of end users. To address the aforementioned limitations, this software code considers a scalable hierarchical model-free transactional control approach that incorporates elements of virtual battery, game theory, and model-free control (MFC) mechanisms. The developed approach separates the control mechanism into upper and lower levels. The MFC modulates the flexible GEB in the lower level with guaranteed thermal comfort of end users in response to the optimal pricing and power signals determined in the upper layer using a Stackelberg game integrated with aggregate virtual battery constraints. Additionally, the usage of MFC necessitates less burdensome computational and communication requirements, thus, it is easily deployable even on small, embedded devices. This software code enables the use of residential and small-size commercial buildings to offer a potentially substantial source of ancillary grid services that are currently underutilized. A hierarchical, model-free transactive building control provides a smooth interface between the grid service requests of utilities and the reliable control required by participating buildings. Model-free control, which supports distributed control architecture, will be a more scalable solution that can be deployed in neighborhood-size systems as well as individual buildings. The proposed approach contributes to the body of knowledge on two main aspects. First, it couples the MFC with the game-theoretic control and proposes a scalable model-free transactive control approach. MFC does not require any modeling effort or model training for the various building loads. This is very beneficial since deriving an accurate model for every single unit participating in DR programs and obtaining all the parameters about the units (e.g., thermal coefficients, standby losses) are infeasible. Also, MFC is computationally efficient, easily deployable even on small, embedded devices, and can be implemented in real time. Second, it integrates the concept of virtual battery into DR via the Stackelberg game. The concept of virtual battery enables efficient coordination and aggregation of a large number of flexible GEB with guaranteed thermal comfort of end users.

Olama, Mohammed [Oak Ridge National Lab. (ORNL), O↗

A Flexible and Generic Functional Mock-up Unit Based Threat Injection Framework for Grid-interactive Efficient Buildings: A Case Study in Modelica

Grid-interactive efficient buildings (GEBs) have been considered as an important asset to support the power grid reliability by utilizing the demand flexibility offered by GEBs. GEBs are enabled by advances in sensors and controls, and the communication between building equipment, whole buildings, and the grid. The integration of different building technologies and network-based communication system makes GEBs vulnerable to passive threats such as equipment failure and active threats such as cyber-attacks. Modeling and simulation is an effective way to evaluate the impact of threats on the system performance. This paper proposes a generic and flexible threat injection framework for commonly-used building energy simulators such as EnergyPlus and Modelica to support threat modeling and evaluation. This framework leverages functional mock-up unit (FMU) to develop a general modeling interface for threat injection and simulation. A numerical case study using Modelica as a building energy simulator is conducted to demonstrate the capability of the framework for supporting single/multiple-order threat modeling and simulation of a GEB. Four threats and their combinations are injected on a Modelica-based threat-free building energy and control system, including operating supply fan at its full speed, remotely cycling the chiller on and off, blocking the chiller from receiving the chilled water supply temperature setpoints, and hijacking the global zone air temperature setpoint. Simulation results show that the cyber-attack that leads to short-term signal blocking has small effects on the system operation due to the "self-healing" feature of the heating, ventilation, and air-conditioning (HVAC) interactive control system. The threat that takes control of resetting the global zone air temperature setpoints has the most adverse impact on the system energy use, peak power demand, thermal comfort and the provision of demand flexibility. The combination of four threats have aggregative effects on the system but the effects are less than the additive effects of the individual threat.

Fu, Yanyang↗

Wood template-supported phase change material composites for durable and form-stable thermal energy storage in buildings

Here, to reduce and shift peak energy loads in buildings, phase change materials (PCMs) with high transition enthalpies and transition temperatures near human thermal comfort are desirable for thermal energy storage (TES). Traditional solid/liquid PCMs suffer from leakage during thermal cycling, requiring encapsulation that lowers heat storage capacity. Wood templates (WTs), with porous and hierarchical structures, provide natural encapsulation scaffolds for PCM containment. Polyethylene glycol (PEG) is a compatible PCM with WTs, but when infiltrated alone, ~30 wt% of PEG binds to wood with no detectable phase change, limiting TES efficiency. To address this, we developed a method to (1) improve the form stability of balsa and pine-based composites (BWT + PCMs and PWT + PCMs) and (2) reduce inactive PCM within the composites to ~10 wt%. BWT + PCMs exhibit transition properties upwards of 114.2 J/g at 25.4 degrees C, with no degradation after 1000 thermal cycles, and similar stiffness compared to raw balsa. Meanwhile, PWT + PCMs exhibit 25 % higher storage efficiency with the addition of poly(ethylene glycol) diacrylate compared to solely PEG-infiltrated PWT. PWT + PCM retains 84 % of raw pine's mechanical stiffness, sufficient for light-duty construction. Our shape-stabilized WT + PCM composites enrich the functionality of wood materials as both ideal TES material candidates and light-duty building construction applications.

25 ENERGY STORAGE↗

Unitary Thermal Energy Management for Propulsion Range Augmentation (UTEMPRA) (CRADA Final Report)

NREL will work with Delphi to develop technology that integrates the thermal management of electric drive vehicle sub-systems into a unified thermal system that reduces auxiliary loads and increases vehicle range. The ultimate goal is to create a cost-effective system which improves climate control efficiency through heat pump operation and waste heat recovery, while maintaining occupant thermal comfort and meeting powertrain thermal requirements. The technology will also aim to reduce the number of independent cooling systems required in electric drive vehicles.

33 ADVANCED PROPULSION SYSTEMS↗

Envelope-driven comfort risk in residential demand response

Residential demand response (DR) is a valuable resource for grid reliability, but remains challenging because the highly heterogeneous residential building stock leads to widely varying and hard-to-predict load and comfort responses during DR events. Although prior research has estimated the technical potential of DR-capable technologies for achieving energy demand savings, little is known about how they affect thermal comfort. In particular, it remains unclear how indoor thermal conditions due to DR depend on the thermal envelope characteristics of the housing stock. To address this gap, this study provides a systematic, location-specific assessment of indoor thermal performance during DR-events across the US housing stock using both typical DR weather data and detailed building metadata. We evaluate how envelope characteristics influence indoor temperatures during realistic simulated summer and winter DR events across 37 US locations, applying both temperature threshold and rate of temperature change criteria to estimate region-level probabilities of discomfort. Additionally, we show the impact of distinct weather patterns that intensify or abate thermal stress on comfort outcomes. Results show a near-universal overheating risk in summer DR events, where comfort outcomes are strongly influenced by rapid risk of comfort violations. In contrast, overall winter DR discomfort risk is lower, risk escalation is more gradual and shows greater sensitivity to event duration. These findings offer a data-driven quantification of comfort risk across diverse climates and building envelopes, demonstrating the need for region-specific DR scheduling and discomfort mitigation strategies tailored to local weather patterns and the performance of existing residential buildings.

Demand response↗

An Approach to High-Performance Affordable Housing Using Point-Source Space Conditioning

This project explored the use of minisplit ductless heat pumps in combination with small through-wall transfer fans to provide space conditioning in small single-story homes, including manufactured homes and homes built by Habitat for Humanity. The objectives were to reduce space-conditioning energy consumption by 50% compared to the 2009 International Energy Conservation Code (ICC 2009) while maintaining home affordability and thermal comfort. The strategy to achieve this goal also included a highly efficient thermal envelope to reduce space-conditioning loads.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Human-in-the-loop Sensing and Control for Commercial Building Energy Efficiency and Occupant Comfort

Most of the existing heating, ventilation and air conditioning (HVAC) systems in commercial buildings operate in a conservative manner by assuming maximum occupancy in each room during pre-specified periods of the week, leading to significant energy being wasted as rooms are over-conditioned compared to the actual requirements of the occupants. Though critical, our understanding of occupancy patterns and thermal comfort needs of the occupants in commercial buildings is lacking and it is well known that both of these quantities are stochastic and time-varying, thus requiring sensing solutions to estimate them. This project had the goal of designing, implementing and evaluating a hardware and software solution to ameliorate this challenge. In particular, a depth camera (one whose pixels reveal distance from the camera as opposed to color values) placed on doorways is used to detect entrance and exit events from thermal zones in the building, and thereby estimate their occupancy levels. This information is then fed to a novel control algorithm that can, through interactions with the HVAC system, learn how to provide control inputs that maximize comfort and minimize energy waste. The resulting system represents a significant improvement over existing controllers for commercial HVAC systems and allowed us to improve our understanding of the design of future human-in-the-loop control solutions. For this solution to be feasible, the project had target metrics for its performance and cost. In particular, entrance and exit events for occupants moving about the building would need to be detected with an accuracy higher than 97%; and the resulting control inputs derived from this information would need to lead to approximately 10% energy savings compared to a schedule-based controller. Furthermore, regarding the final hardware design, the project had a target bill of materials (BOM) cost for the sensing solution of less than US$200 per unit while using less than 25W of power on average. All of these target metrics were met or exceeded by our final proposed solution. We performed evaluations by deploying the system in over 20 rooms of different types across 6 commercial buildings in Pittsburgh, PA over the course of three years, and performing targeted controlled experiments to test its performance along the different metrics. The human-in-the-loop control solutions (both hardware and software) developed through this project are expected to lead to significant improvements in the comfort and energy efficiency of HVAC systems used in commercial buildings. The insights we developed through the project pave the way to HVAC systems that can condition interior spaces according to their real-time utilization and the thermal comfort needs of the occupants, thereby reducing energy use. They also open up a new learning-based way of configuring HVAC controllers without having to manually fine-tune them for each building. These innovations can significantly increase the adoption of novel control solutions by the industry and thereby save resources and reduce costs of operation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

WRF-Comfort: simulating microscale variability in outdoor heat stress at the city scale with a mesoscale model

Abstract. Urban overheating and its ongoing exacerbation due to global warming and urban development lead to increased exposure to urban heat and increased thermal discomfort and heat stress. To quantify thermal stress, specific indices have been proposed that depend on air temperature, mean radiant temperature (MRT), wind speed, and relative humidity. While temperature and humidity vary on scales of hundreds of meters, MRT and wind speed are strongly affected by individual buildings and trees and vary on the meter scale. Therefore, most numerical thermal comfort studies apply microscale models to limited spatial domains (commonly representing urban neighborhoods with building blocks) with resolutions on the order of 1 m and a few hours of simulation. This prevents the analysis of the impact of city-scale adaptation and/or mitigation strategies on thermal stress and comfort. To solve this problem, we develop a methodology to estimate thermal stress indicators and their subgrid variability in mesoscale models – here applied to the multilayer urban canopy parameterization BEP-BEM within the Weather Research and Forecasting (WRF) model. The new scheme (consisting of three main steps) can readily assess intra-neighborhood-scale heat stress distributions across whole cities and for timescales of minutes to years. The first key component of the approach is the estimation of MRT in several locations within streets for different street orientations. Second, mean wind speed and its subgrid variability are downscaled as a function of the local urban morphology based on relations derived from a set of microscale LES and RANS simulations across a wide range of realistic and idealized urban morphologies. Lastly, we compute the distributions of two thermal stress indices for each grid square, combining all the subgrid values of MRT, wind speed, air temperature, and absolute humidity. From these distributions, we quantify the high and low tails of the heat stress distribution in each grid square across the city, representing the thermal diversity experienced in street canyons. In this contribution, we present the core methodology as well as simulation results for Madrid (Spain), which illustrate strong differences between heat stress indices and common heat metrics like air or surface temperature both across the city and over the diurnal cycle.

Geology↗

Multi-criteria thermal resilience certification scheme for indoor built environments during heat waves

With climate change, the indoor built environment is expected to significantly influence the occupant's safety and well-being. A novel multi-criteria thermal resilience certification scheme for indoor built environments during extreme heat events is proposed in this paper. The certification scheme considers overheating, thermal comfort, heat stress, and hygrothermal discomfort in built environments. These criteria are quantified using key performance indicators like indoor overheating degree, hours of exceedance, wet-bulb globe temperature, and heat index, respectively. This scheme is developed based on existing best practices like standards, rating systems, and literature. The scheme is implemented on a benchmark building energy performance model for detached post-World War II dwellings in Belgium as a case study using weather data measured from the City of Brussels. The indoor overheating in the reference dwelling is assessed with a static threshold of 27 °C for the bedrooms and adaptive thresholds for other areas. The analysis found that the building performance is within the defined threshold levels throughout the heat wave duration for all criteria. Therefore, the reference dwelling got a maximum attainable score of four points and is rated five-star for thermal resilience during heat waves. The proposed certification scheme is intended as a standardized framework and highlights the need for further revisions in building performance policies and guidelines.

Climate change↗

National energy savings potential of cellular shades: A measurement and simulation study

Windows are major contributors to energy demand in residential homes because of their inferior thermal resistance compared with the opaque envelope, and sometimes from unwanted solar heat gain. Window attachments can help mitigate the energy demand by controlling the solar heat gains and enhancing window thermal resistance. Cellular shades have the potential of superior thermal performance compared with generic shades because of its honeycomb structure. Here, in this study, the team analyzed the energy savings potential of cellular shades in residential homes via experimental testing for two heating seasons and energy simulations. Five shading devices—three single-cell and two double cellular/cell-in-cell shades—were used to compare the performance with generic horizontal venetian blinds using two nearly identical side-by-side rooms in a residential home. The experimental testing showed daily heating energy savings in the range of 17%–36% compared with the case without shades. The experimental testing data also exhibited improvements in thermal comfort when using cellular shades. Additionally, energy simulations were performed to evaluate the energy savings potential of the cellular shades using a residential prototype home, which demonstrated energy savings up to 9 kWh/m2/year in cold climates. The total site energy savings for heating and cooling from cellular shades was up to ~9% for the home with a heat pump and up to ~15% for a home with a gas furnace compared with cases without any shading devices. The energy savings at a national scale were up to 14.6 TWh assuming a 20% penetration rate in residential homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Effectiveness of street trees in reducing air temperature and outdoor heat exposure in Las Vegas

Urban greening and especially tree planting strategies are being widely planned and implemented to mitigate urban overheating and thermal stress in many urban areas. However, the effectiveness of these strategies depends on multiple factors, including urban morphology, environmental conditions, and tree characteristics. This study investigates the effects of street tree planting strategies on air temperature and outdoor heat exposure in Las Vegas by combining an urbanized mesoscale climate model coupled to a multi-layer street tree model (Weather Research and Forecasting-BEP-Tree; Δ x = 900 m) with a microscale pedestrian heat exposure model (Temperatures of Urban Facets for Pedestrian; Δ x = 1 m). A series of simulations are conducted for July and August 2022. Large city-wide increases of a drought tolerant tree species cool air temperature mainly during the nighttime (up to 1.5 °C), with daytime effects being limited due to leaves shedding sensible instead of latent heat as stomata close in response to high vapor pressure deficits. Increased evaporative cooling is achieved with a different tree species (double at night, and reaching 0.4 °C during the day), but water requirements increase threefold. Despite their relatively small effect on air temperature during the day, trees provide significant shade by intercepting solar radiation, reducing mean radiant temperature (up to 16 °C) and enhancing outdoor thermal comfort, a major benefit of street trees in hot arid climates. The nighttime cooling of trees and the daytime reduction of radiant loading show potential to reduce the heat-related health impacts. Our results highlight the need to evaluate the effects of street trees on a case-by-case basis.

54 ENVIRONMENTAL SCIENCES↗

An Approach to High-Performance Affordable Housing Using Point-Source Space Conditioning

In cooperation with the Building America Program, The Levy Partnership explored a variety of options to reduce space-conditioning energy consumption, working with partners to design, manu- facture, and build test homes in three states. The Levy Partnership tested the use of minisplit ductless heat pumps in combi- nation with small through-wall transfer fans to provide space conditioning in small single-story homes, including manufactured homes and homes built by Habitat for Humanity. The team set out to achieve 50% less energy consumption, compared to the 2009 International Energy Conservation Code, while maintaining home afford- ability and thermal comfort. The strategy also included a highly efficient thermal envelope to reduce space-conditioning loads.

30 DIRECT ENERGY CONVERSION↗