Search NASA⌕ Search

SEARCH · Search NASA

Results for “THERMAL EMISSION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

On-Orbit Calibration and Performance Assessments of Terra and Aqua Modis Thermal Emissive Bands

Terra and Aqua MODIS have successfully operated for more than 20 and 18 years, respectively, and far exceeded their designed lifetimes of 6 years. MODIS has 36 spectral bands, among which 16 are the thermal emissive bands (TEB) covering a wavelength range from 3.75 to 14.24 μm. Observations from the MODIS TEB have been used to generate a number of data products, such as surface/cloud/atmospheric temperatures, cloud top altitude, and water vapor properties. To a large extent, the quality of the MODIS L1B radiance product has been maintained through the entirety of each mission via extensive on-orbit calibration and validation efforts. MODIS TEB calibration uses a quadratic algorithm and is referenced to an on-board blackbody with its temperature measurements traceable to the NIST standard. We provide an overview of the MODIS instrument operations, key TEB calibration activities, and algorithms used in the latest L1B data Collection 6.1 (C6.1) and describe the TEB on-orbit performance for both Terra and Aqua MODIS. The TEB gain trends have been stable to within 5% over the Terra mission after 2003 under the same electronic configuration, except for bands 27 to 30, and within 3% over the Aqua mission. The Terra MODIS optical crosstalk correction implemented right after launch has been very effective in removing the ghost images in its photoconductive detector bands 32 to 36. Starting from C6.1, an electronic crosstalk correction algorithm has also been applied to the Terra MODIS photovoltaic detector long-wave infrared bands 27 to 30. The noise characterization performance remains stable with most TEB detectors continuously meeting their design requirements. A gradual loss of the Aqua MODIS radiative cooler margin reached its maximum in 2013 and has been slowly recovering since then. On-orbit changes in TEB response versus scan angle are extremely small based on pitch maneuver observations and assessments using vicarious approaches. The remaining challenges in TEB calibration and proposed improvements for the upcoming data collection with L1B data production and reprocessing are discussed.

Terra↗

Martian Global Surface Mineralogy from the Thermal Emission Spectrometer: Surface Emissivity, Mineral Map, and Spectral Endmember Data Products

One of the primary goals of the Thermal Emission Spectrometer experiment on the Mars Global Surveyor is to determine the mineralogy of the Martian surface. This information has been used to place constraints on the range of igneous processes present. The extent of water related processes on Mars has been significantly constrained by the TES experiment. The mineralogy of the Martian dust has also been refined using TES data. These mineralogical results have made a significant contribution towards determining the development of Mars, complimenting other datasets and existing information. Mineralogical determination requires the isolation of surface emissivity from the measured radiance and a variety of techniques have been developed for this purpose. Additionally, deconvolution techniques have been developed and extensively tested to separate the individual mineral contributions to the surface emissivity. These methods and techniques have produced a variety of data products that are currently available through http://tes.asu.edu/

J L Bandfield↗

Determination of the ozone profile from the outgoing thermal emission

Problems of the information content of measuring the spectral and angular distribution of the outgoing thermal emission of the atmosphere-earth system in the 9.6 mm ozone absorption band are discussed. Two methods (nadir and limb) of remote measurement are considered. Information data obtained are evaluated according to three systems. Effectiveness of the regression interpretation method using the data of nadir and limb measurements is shown.

Borisenkov, Y. P.↗

NOAA-20 VIIRS Thermal Emissive Bands On-Orbit Performance

The VIIRS (Visible Infrared Imaging Radiometer Suite) instrument onboard the NOAA-20 satellite (launched on November 18, 2017) started to collect Earth-view data after its nadir door opened on December 13, 2017. Seven of the VIIRS bands, I4-5 and M12-16 are thermal emissive bands (TEBs), covering a spectral range from 3.6 to 12.5 meters. They began collecting valid data after the cold focal plane assembly (CFPA) cooled down to its nominal operating temperature on January 6, 2018. This paper will present the performance of each TEB, including calibration coefficients, noise equivalent differential temperature (NEdT), on-orbit calibration coefficient estimates from scheduled onboard blackbody warm-up and cool-down (WUCD) data, as well as related telemetry temperatures. Several methods are tested and compared in the WUCD data analysis for estimating the calibration coefficients. Based on the preliminary results, the NEdT of each band is well below the design specification and very close to that of the VIIRS onboard the Suomi National Polar-orbiting Partnership (SNPP) satellite. The detector gains appear stable for bands on the short- and mid-wave infrared CFPA, whereas the detector gains have larger than expected degradation for bands on the long-wave infrared CFPA during the early mission. All TEB-related telemetry temperatures are stable. The on-orbit performance of NOAA-20 VIIRS TEB is compared with VIIRS onboard the SNPP.

Thermal Emissive Bands (TEB)↗

The thermal emission spectrum of Io and a determination of the heat flux from its hot spots

Observations of thermal emission from Io in the near infrared made during an eclipse were combined with unpublished 8- to 13-micron intermediate band photometry and a 16- to 22-micron spectrum to specify Io's emission spectrum from 2.2 to 22 microns. Models were calculated having 'hot spots' at several different temperatures superposed on a surface, the major part of which is assumed to be at the solar equilibrium temperature. It was possible to fit the entire composite spectrum with this model. It is argued that the total emission from the hot spots can be equated to the nonsolar energy input into Io. The disk-averaged heat radiated by the hot spots is found to be 180 + or 60 microwatts/sq cm = 43 + or - 14 microcalories/sq cm-sec. A possible bimodal temperature distribution of the hot spots is discussed.

Sinton, W. M.↗

Thermal emission spectra of Mars (5.4-10.5 microns) - Evidence for sulfates, carbonates, and hydrates

Spectra of the Martian thermal emission in the 5.4-10.5 micron region are reported. Emission features at 7.8 and 9.7 microns are attributed to surface silicates, and an emission feature at 6.1 micron is attributed to a molecular water component of the surface material. An absorption band at 8.7 micron and a possible one at 9.8 microns is attributed to sulfate or bisulfate anions probably located at a distorted crystalline site, and an absorption band at 6.7 microns is attributed to carbonate or bicarbonate anions located in a distorted crystalline site. Spectral simulations indicate that the sulfate- and carbonate-bearing minerals are contained in the same particles of airborne dust as the dominant silicate minerals, that the dust optical depth is about 0.6 at a reference wavelength of 0.3 micron over the area of the observed spots, and that sulfates and carbonates constitute 10-15 percent and 1-3 percent by volume of the airborne dust, respectively.

Pollack, James B.↗

The NuSTAR View of the Non-Thermal Emission from PSR J0437-4715

We present a hard X-ray Nuclear Spectroscopic Telescope Array (NuSTAR) observation of PSR J0437-4715, the nearest millisecond pulsar. The known pulsations at the apparent pulse period approximately 5.76 ms are observed with a significance of 3.7sigma, at energies up to 20 keV above which the NuSTAR background dominates. We measure a photon index gamma = 1.50 +/- 0.25(90 per cent confidence) for the power-law fit to the non-thermal emission. It had been shown that spectral models with two or three thermal components fit the XMM-Newton spectrum of PSR J0437-4715, depending on the slope of the power-law component, and the amount of absorption of soft X-rays. The new constraint on the high-energy emission provided by NuSTAR removes ambiguities regarding the thermal components of the emission below 3 keV. We performed a simultaneous spectral analysis of the XMM-Newton and NuSTAR data to confirm that three thermal components and a power law are required to fit the 0.3-20 keV emission of PSR J0437-4715. Adding a ROSAT-PSPC spectrum further confirmed this result and allowed us to better constrain the temperatures of the three thermal components. A phase resolved analysis of the NuSTAR data revealed no significant change in the photon index of the high-energy emission. This NuSTAR observation provides further impetus for future observations with the NICER mission (Neutron Star Interior Composition Explorer) whose sensitivity will provide much stricter constraints on the equation of state of nuclear matter by combining model fits to the pulsars phase-folded light curve with the pulsars well-defined mass and distance from radio timing observations.

stars; neutro↗

A description of the correlated k distributed method for modeling nongray gaseous absorption, thermal emission, and multiple scattering in vertically inhomogeneous atmospheres

A radiative transfer method for treating nongray gaseous absorption and thermal emission in vertically inhomogeneous multiple scattering atmospheres is described. Probability density distributions of absorption coefficient strength are derived from line-by-line calculations to construct line-by-line and band model based k distributions. The monotonic ordering of absorption coefficient strengths in these k distributions implicitly preserves the monochromatic structure of the atmosphere at different pressure levels, thus simulating monochromatic spectral integration at a fraction of the line-by-line computing cost. The k distribution approach also permits accurate modeling of overlapping absorption by different atmospheric gases and accurate treatment of nongray absorption in multiple scattering media. It is shown that the correlated k distribution method is capable of achieving numerical accuracy to within 1 percent of cooling rates obtained with line-by-line calculations throughout the troposphere and most of the stratosphere.

Lacis, Andrew A.↗

Comparison of the MODIS and VIIRS Thermal Emissive Band Radiometric Calibration

Moderate Resolution Imaging Spectroradiometer (MODIS) and Visible Infrared Imaging Radiometer Suite (VIIRS) are major instruments for Earth science observations.Nearly 40 MODIS scientific products and a wide range of VIIRS environmental data records are produced using their global observations. The consistency of the MODIS and VIIRS calibrated data is important for the study of Earth science. This article assesses the calibration consistency of the Aqua MODIS and VIIRS thermal emissive band (TEB) data. To remove the impact of the mismatched relative spectral response (RSR) on the comparisons, the simultaneous nadir observation data from the cross-track infrared sounder (CrIS) and the infrared atmospheric sounding interferometer (IASI) are used as references in two different methods to independently verify the consistency. The comparisons of the MODIS and VIIRS TEB calibrated data show that the brightness temperature (BT) differences for comparable bands between MODIS and VIIRS are in general within 0.2 K for BT larger than 230 K. The differences of all comparable MODIS and VIIRS TEBs are consistent over time. MODIS measurements agree better with N20 VIIRS than with Suomi National Polar-orbiting Partnership (S-NPP) VIIRS. The S-NPP VIIRS measurements are higher than N20 VIIRS, within 0.1 Kfor long-wave infrared (LWIR) bands and 0.3 K for band M13.

Calibration↗

Early Calibration and Performance Assessments of NOAA-20 VIIRS Thermal Emissive Bands

The Visible Infrared Imaging Radiometer Suite (VIIRS) sensor aboard the NOAA-20 (previously JPSS-1) spacecraft has successfully operated since its launch in November, 2017. Similar to the first VIIRS instrument on the Suomi-NPP spacecraft, data is collected in 22 spectral bands that are calibrated by a set of onboard calibrators. This paper provides an overview of the NOAA-20 VIIRS on-orbit operation and calibration, with a particular focus on the thermal emissive bands (TEBs). Results presented in this paper include the on-orbit changes in the TEB spectral band responses, detector noise characterization, and key calibration parameters, such as the non-linear coefficients derived from the blackbody warm-up cool-down cycle. Other issues, such as the early mission long-wave infrared (LWIR) response degradation due to icing on the dewar window, and their impact on sensor calibration are also discussed. Since launch, the VIIRS instrument temperature has been stable to within ± 0.8K and the cold focal plane temperatures are well controlled with variations less than 40 mK. With the exception of the early degradation observed in the LWIR bands, the TEB gains have been stable to within 0.04% (except I5 at 0.07%). Based on the current performance, VIIRS is expected to meet its calibration requirements throughout its design lifetime.

NEdT↗